2933 compiler warning gags need better granularityReviewed by: Eric Schrock <eric.schrock@delphix.com>Approved by: Garrett D'Amore <garrett@damore.org>
PSARC/2008/336 Extended VTOC6708609 Support booting on disks > 1TB (phase 1)6672960 cmlb: default minor nodes for disks > 1TB is not EFI/GPT style6727240 When a fat32 partition created in the part
PSARC/2008/336 Extended VTOC6708609 Support booting on disks > 1TB (phase 1)6672960 cmlb: default minor nodes for disks > 1TB is not EFI/GPT style6727240 When a fat32 partition created in the part of the disk after 1TB, block I/O and umount fail
show more ...
6528974 Usage of DKIOCGETEFI has changed and impacts vdisks using zfs volumes6558966 Virtual disks created from files do not support EFI labels
6470037 remove global disable of some potentially useful lint warnings from the kernel lint build
6419154 libpcp pcp_init routine should accept service names6428416 CPUs greater than NCPU are stopped too early in boot6436930 qcn drv needs to handle EWOULDBLOCK returned by hv_cnputchar6437727 v
6419154 libpcp pcp_init routine should accept service names6428416 CPUs greater than NCPU are stopped too early in boot6436930 qcn drv needs to handle EWOULDBLOCK returned by hv_cnputchar6437727 vDisk should support EFI labels6437738 vDisk should support devid6441930 fillsysinfo should cap max sun4v queue size to kernel limits6441933 The broken MD detection code should be improved6445825 domaining_enabled variable does not tell the whole story6449959 vDisk DKIOCSETWCE/DKIOCGETWCE ioctls are not correctly implemented6451118 Elevate libpcp from a platform lib to a sun4v lib6451490 ldc_chkq incorrectly returns queue empty when data is available on streaming mode channel6456875 VIO drivers should use LDC shared memory for better performance6456880 LDC link layer fails to clear interrupt state properly6456928 drd service is not enabled if installed through an upgrade6457162 vswitch needs to cope with dropped pkts when talking to obp6457166 vswitch calculating bounded range of descriptors incorrectly
FWARC 2005/633 Project Q Logial Domaining UmbrellaFWARC 2005/739 sun4v channelsFWARC 2006/055 Domain ServicesFWARC 2006/072 sun4v virtual devices machine description dataFWARC 2006/074 sun4v inte
FWARC 2005/633 Project Q Logial Domaining UmbrellaFWARC 2005/739 sun4v channelsFWARC 2006/055 Domain ServicesFWARC 2006/072 sun4v virtual devices machine description dataFWARC 2006/074 sun4v interrupt cookiesFWARC 2006/075 Channel devices, Virtual Disk client and server bindingsFWARC 2006/076 Virtual Network Client and switch BindingsFWARC 2006/081 Virtual Logical Domain Channel (vldc) BindingsFWARC 2006/086 LDOM variablesFWARC 2006/105 LDOM support for NCPFWARC 2006/110 Domain Services MD node and other misc propertiesFWARC 2006/117 Virtual Console Concentrator BindingsFWARC 2006/135 sun4v channel console packetsFWARC 2006/140 sun4v channels transport protocolFWARC 2006/141 FMA Domain ServicesFWARC 2006/174 NCS HV UpdateFWARC 2006/184 sun4v channels shared memoryFWARC 2006/195 Virtual IO Communication ProtocolPSARC 2006/152 Logical Domain Channels Transport API6272074 Need interface to determine execution unit sharing.6354556 Add machine description kernel framework support6391870 LDoms v1.0 Solaris Changes