xref: /linux/drivers/thermal/Kconfig (revision bd628c1bed7902ec1f24ba0fe70758949146abbe)
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
6	tristate "Generic Thermal sysfs driver"
7	help
8	  Generic Thermal Sysfs driver offers a generic mechanism for
9	  thermal management. Usually it's made up of one or more thermal
10	  zone and cooling device.
11	  Each thermal zone contains its own temperature, trip points,
12	  cooling devices.
13	  All platforms with ACPI thermal support can use this driver.
14	  If you want this support, you should say Y or M here.
15
16if THERMAL
17
18config THERMAL_STATISTICS
19	bool "Thermal state transition statistics"
20	help
21	  Export thermal state transition statistics information through sysfs.
22
23	  If in doubt, say N.
24
25config THERMAL_EMERGENCY_POWEROFF_DELAY_MS
26	int "Emergency poweroff delay in milli-seconds"
27	depends on THERMAL
28	default 0
29	help
30	  Thermal subsystem will issue a graceful shutdown when
31	  critical temperatures are reached using orderly_poweroff(). In
32	  case of failure of an orderly_poweroff(), the thermal emergency
33	  poweroff kicks in after a delay has elapsed and shuts down the system.
34	  This config is number of milliseconds to delay before emergency
35	  poweroff kicks in. Similarly to the critical trip point,
36	  the delay should be carefully profiled so as to give adequate
37	  time for orderly_poweroff() to finish on regular execution.
38	  If set to 0 emergency poweroff will not be supported.
39
40	  In doubt, leave as 0.
41
42config THERMAL_HWMON
43	bool
44	prompt "Expose thermal sensors as hwmon device"
45	depends on HWMON=y || HWMON=THERMAL
46	default y
47	help
48	  In case a sensor is registered with the thermal
49	  framework, this option will also register it
50	  as a hwmon. The sensor will then have the common
51	  hwmon sysfs interface.
52
53	  Say 'Y' here if you want all thermal sensors to
54	  have hwmon sysfs interface too.
55
56config THERMAL_OF
57	bool
58	prompt "APIs to parse thermal data out of device tree"
59	depends on OF
60	default y
61	help
62	  This options provides helpers to add the support to
63	  read and parse thermal data definitions out of the
64	  device tree blob.
65
66	  Say 'Y' here if you need to build thermal infrastructure
67	  based on device tree.
68
69config THERMAL_WRITABLE_TRIPS
70	bool "Enable writable trip points"
71	help
72	  This option allows the system integrator to choose whether
73	  trip temperatures can be changed from userspace. The
74	  writable trips need to be specified when setting up the
75	  thermal zone but the choice here takes precedence.
76
77	  Say 'Y' here if you would like to allow userspace tools to
78	  change trip temperatures.
79
80choice
81	prompt "Default Thermal governor"
82	default THERMAL_DEFAULT_GOV_STEP_WISE
83	help
84	  This option sets which thermal governor shall be loaded at
85	  startup. If in doubt, select 'step_wise'.
86
87config THERMAL_DEFAULT_GOV_STEP_WISE
88	bool "step_wise"
89	select THERMAL_GOV_STEP_WISE
90	help
91	  Use the step_wise governor as default. This throttles the
92	  devices one step at a time.
93
94config THERMAL_DEFAULT_GOV_FAIR_SHARE
95	bool "fair_share"
96	select THERMAL_GOV_FAIR_SHARE
97	help
98	  Use the fair_share governor as default. This throttles the
99	  devices based on their 'contribution' to a zone. The
100	  contribution should be provided through platform data.
101
102config THERMAL_DEFAULT_GOV_USER_SPACE
103	bool "user_space"
104	select THERMAL_GOV_USER_SPACE
105	help
106	  Select this if you want to let the user space manage the
107	  platform thermals.
108
109config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
110	bool "power_allocator"
111	select THERMAL_GOV_POWER_ALLOCATOR
112	help
113	  Select this if you want to control temperature based on
114	  system and device power allocation. This governor can only
115	  operate on cooling devices that implement the power API.
116
117endchoice
118
119config THERMAL_GOV_FAIR_SHARE
120	bool "Fair-share thermal governor"
121	help
122	  Enable this to manage platform thermals using fair-share governor.
123
124config THERMAL_GOV_STEP_WISE
125	bool "Step_wise thermal governor"
126	help
127	  Enable this to manage platform thermals using a simple linear
128	  governor.
129
130config THERMAL_GOV_BANG_BANG
131	bool "Bang Bang thermal governor"
132	default n
133	help
134	  Enable this to manage platform thermals using bang bang governor.
135
136	  Say 'Y' here if you want to use two point temperature regulation
137	  used for fans without throttling.  Some fan drivers depend on this
138	  governor to be enabled (e.g. acerhdf).
139
140config THERMAL_GOV_USER_SPACE
141	bool "User_space thermal governor"
142	help
143	  Enable this to let the user space manage the platform thermals.
144
145config THERMAL_GOV_POWER_ALLOCATOR
146	bool "Power allocator thermal governor"
147	help
148	  Enable this to manage platform thermals by dynamically
149	  allocating and limiting power to devices.
150
151config CPU_THERMAL
152	bool "generic cpu cooling support"
153	depends on CPU_FREQ
154	depends on THERMAL_OF
155	help
156	  This implements the generic cpu cooling mechanism through frequency
157	  reduction. An ACPI version of this already exists
158	  (drivers/acpi/processor_thermal.c).
159	  This will be useful for platforms using the generic thermal interface
160	  and not the ACPI interface.
161
162	  If you want this support, you should say Y here.
163
164config CLOCK_THERMAL
165	bool "Generic clock cooling support"
166	depends on COMMON_CLK
167	depends on PM_OPP
168	help
169	  This entry implements the generic clock cooling mechanism through
170	  frequency clipping. Typically used to cool off co-processors. The
171	  device that is configured to use this cooling mechanism will be
172	  controlled to reduce clock frequency whenever temperature is high.
173
174config DEVFREQ_THERMAL
175	bool "Generic device cooling support"
176	depends on PM_DEVFREQ
177	depends on PM_OPP
178	help
179	  This implements the generic devfreq cooling mechanism through
180	  frequency reduction for devices using devfreq.
181
182	  This will throttle the device by limiting the maximum allowed DVFS
183	  frequency corresponding to the cooling level.
184
185	  In order to use the power extensions of the cooling device,
186	  devfreq should use the simple_ondemand governor.
187
188	  If you want this support, you should say Y here.
189
190config THERMAL_EMULATION
191	bool "Thermal emulation mode support"
192	help
193	  Enable this option to make a emul_temp sysfs node in thermal zone
194	  directory to support temperature emulation. With emulation sysfs node,
195	  user can manually input temperature and test the different trip
196	  threshold behaviour for simulation purpose.
197
198	  WARNING: Be careful while enabling this option on production systems,
199	  because userland can easily disable the thermal policy by simply
200	  flooding this sysfs node with low temperature values.
201
202config HISI_THERMAL
203	tristate "Hisilicon thermal driver"
204	depends on ARCH_HISI || COMPILE_TEST
205	depends on HAS_IOMEM
206	depends on OF
207	default y
208	help
209	  Enable this to plug hisilicon's thermal sensor driver into the Linux
210	  thermal framework. cpufreq is used as the cooling device to throttle
211	  CPUs when the passive trip is crossed.
212
213config IMX_THERMAL
214	tristate "Temperature sensor driver for Freescale i.MX SoCs"
215	depends on ARCH_MXC || COMPILE_TEST
216	depends on NVMEM || !NVMEM
217	depends on MFD_SYSCON
218	depends on OF
219	help
220	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
221	  It supports one critical trip point and one passive trip point.  The
222	  cpufreq is used as the cooling device to throttle CPUs when the
223	  passive trip is crossed.
224
225config MAX77620_THERMAL
226	tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
227	depends on MFD_MAX77620
228	depends on OF
229	help
230	  Support for die junction temperature warning alarm for Maxim
231	  Semiconductor PMIC MAX77620 device. Device generates two alarm
232	  interrupts when PMIC die temperature cross the threshold of
233	  120 degC and 140 degC.
234
235config QORIQ_THERMAL
236	tristate "QorIQ Thermal Monitoring Unit"
237	depends on THERMAL_OF
238	depends on HAS_IOMEM
239	help
240	  Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
241	  It supports one critical trip point and one passive trip point. The
242	  cpufreq is used as the cooling device to throttle CPUs when the
243	  passive trip is crossed.
244
245config SPEAR_THERMAL
246	tristate "SPEAr thermal sensor driver"
247	depends on PLAT_SPEAR || COMPILE_TEST
248	depends on HAS_IOMEM
249	depends on OF
250	help
251	  Enable this to plug the SPEAr thermal sensor driver into the Linux
252	  thermal framework.
253
254config ROCKCHIP_THERMAL
255	tristate "Rockchip thermal driver"
256	depends on ARCH_ROCKCHIP || COMPILE_TEST
257	depends on RESET_CONTROLLER
258	depends on HAS_IOMEM
259	help
260	  Rockchip thermal driver provides support for Temperature sensor
261	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
262	  trip point. Cpufreq is used as the cooling device and will throttle
263	  CPUs when the Temperature crosses the passive trip point.
264
265config RCAR_THERMAL
266	tristate "Renesas R-Car thermal driver"
267	depends on ARCH_RENESAS || COMPILE_TEST
268	depends on HAS_IOMEM
269	help
270	  Enable this to plug the R-Car thermal sensor driver into the Linux
271	  thermal framework.
272
273config RCAR_GEN3_THERMAL
274	tristate "Renesas R-Car Gen3 thermal driver"
275	depends on ARCH_RENESAS || COMPILE_TEST
276	depends on HAS_IOMEM
277	depends on OF
278	help
279	  Enable this to plug the R-Car Gen3 thermal sensor driver into the Linux
280	  thermal framework.
281
282config KIRKWOOD_THERMAL
283	tristate "Temperature sensor on Marvell Kirkwood SoCs"
284	depends on MACH_KIRKWOOD || COMPILE_TEST
285	depends on HAS_IOMEM
286	depends on OF
287	help
288	  Support for the Kirkwood thermal sensor driver into the Linux thermal
289	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
290
291config DOVE_THERMAL
292	tristate "Temperature sensor on Marvell Dove SoCs"
293	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
294	depends on HAS_IOMEM
295	depends on OF
296	help
297	  Support for the Dove thermal sensor driver in the Linux thermal
298	  framework.
299
300config DB8500_THERMAL
301	tristate "DB8500 thermal management"
302	depends on MFD_DB8500_PRCMU
303	default y
304	help
305	  Adds DB8500 thermal management implementation according to the thermal
306	  management framework. A thermal zone with several trip points will be
307	  created. Cooling devices can be bound to the trip points to cool this
308	  thermal zone if trip points reached.
309
310config ARMADA_THERMAL
311	tristate "Marvell EBU Armada SoCs thermal management"
312	depends on ARCH_MVEBU || COMPILE_TEST
313	depends on HAS_IOMEM
314	depends on OF
315	help
316	  Enable this option if you want to have support for thermal management
317	  controller present in Marvell EBU Armada SoCs (370,375,XP,38x,7K,8K).
318
319config DA9062_THERMAL
320	tristate "DA9062/DA9061 Dialog Semiconductor thermal driver"
321	depends on MFD_DA9062 || COMPILE_TEST
322	depends on OF
323	help
324	  Enable this for the Dialog Semiconductor thermal sensor driver.
325	  This will report PMIC junction over-temperature for one thermal trip
326	  zone.
327	  Compatible with the DA9062 and DA9061 PMICs.
328
329config MTK_THERMAL
330	tristate "Temperature sensor driver for mediatek SoCs"
331	depends on ARCH_MEDIATEK || COMPILE_TEST
332	depends on HAS_IOMEM
333	depends on NVMEM || NVMEM=n
334	depends on RESET_CONTROLLER
335	default y
336	help
337	  Enable this option if you want to have support for thermal management
338	  controller present in Mediatek SoCs
339
340menu "Intel thermal drivers"
341depends on X86 || X86_INTEL_QUARK || COMPILE_TEST
342source "drivers/thermal/intel/Kconfig"
343endmenu
344
345menu "Broadcom thermal drivers"
346depends on ARCH_BCM || ARCH_BRCMSTB || ARCH_BCM2835 || COMPILE_TEST
347source "drivers/thermal/broadcom/Kconfig"
348endmenu
349
350menu "Texas Instruments thermal drivers"
351depends on ARCH_HAS_BANDGAP || COMPILE_TEST
352depends on HAS_IOMEM
353source "drivers/thermal/ti-soc-thermal/Kconfig"
354endmenu
355
356menu "Samsung thermal drivers"
357depends on ARCH_EXYNOS || COMPILE_TEST
358source "drivers/thermal/samsung/Kconfig"
359endmenu
360
361menu "STMicroelectronics thermal drivers"
362depends on (ARCH_STI || ARCH_STM32) && OF
363source "drivers/thermal/st/Kconfig"
364endmenu
365
366config TANGO_THERMAL
367	tristate "Tango thermal management"
368	depends on ARCH_TANGO || COMPILE_TEST
369	help
370	  Enable the Tango thermal driver, which supports the primitive
371	  temperature sensor embedded in Tango chips since the SMP8758.
372	  This sensor only generates a 1-bit signal to indicate whether
373	  the die temperature exceeds a programmable threshold.
374
375source "drivers/thermal/tegra/Kconfig"
376
377config GENERIC_ADC_THERMAL
378	tristate "Generic ADC based thermal sensor"
379	depends on IIO
380	help
381	  This enabled a thermal sysfs driver for the temperature sensor
382	  which is connected to the General Purpose ADC. The ADC channel
383	  is read via IIO framework and the channel information is provided
384	  to this driver. This driver reports the temperature by reading ADC
385	  channel and converts it to temperature based on lookup table.
386
387menu "Qualcomm thermal drivers"
388depends on (ARCH_QCOM && OF) || COMPILE_TEST
389source "drivers/thermal/qcom/Kconfig"
390endmenu
391
392config ZX2967_THERMAL
393	tristate "Thermal sensors on zx2967 SoC"
394	depends on ARCH_ZX || COMPILE_TEST
395	help
396	  Enable the zx2967 thermal sensors driver, which supports
397	  the primitive temperature sensor embedded in zx2967 SoCs.
398	  This sensor generates the real time die temperature.
399
400config UNIPHIER_THERMAL
401	tristate "Socionext UniPhier thermal driver"
402	depends on ARCH_UNIPHIER || COMPILE_TEST
403	depends on THERMAL_OF && MFD_SYSCON
404	help
405	  Enable this to plug in UniPhier on-chip PVT thermal driver into the
406	  thermal framework. The driver supports CPU thermal zone temperature
407	  reporting and a couple of trip points.
408endif