xref: /linux/drivers/thermal/Kconfig (revision 6dfafbd0299a60bfb5d5e277fdf100037c7ded07)
1# SPDX-License-Identifier: GPL-2.0-only
2#
3# Generic thermal drivers configuration
4#
5
6menuconfig THERMAL
7	bool "Thermal drivers"
8	help
9	  Thermal drivers offer a generic mechanism for
10	  thermal management. Usually it's made up of one or more thermal
11	  zones and cooling devices.
12	  Each thermal zone contains its own temperature, trip points,
13	  and cooling devices.
14	  All platforms with ACPI or Open Firmware thermal support can use
15	  this driver.
16	  If you want this support, you should say Y here.
17
18if THERMAL
19
20config THERMAL_NETLINK
21	bool "Thermal netlink management"
22	depends on NET
23	help
24	  The thermal framework has a netlink interface to do thermal
25	  zones discovery, temperature readings and events such as
26	  trip point crossed, cooling device update or governor
27	  change. It is recommended to enable the feature.
28
29config THERMAL_STATISTICS
30	bool "Thermal state transition statistics"
31	help
32	  Export thermal state transition statistics information through sysfs.
33
34	  If in doubt, say N.
35
36config THERMAL_DEBUGFS
37	bool "Thermal subsystem debug support"
38	depends on DEBUG_FS
39	help
40	  Say Y to allow the thermal subsystem to collect diagnostic
41	  information that can be accessed via debugfs.
42
43config THERMAL_CORE_TESTING
44	tristate "Thermal core testing facility"
45	depends on DEBUG_FS
46	help
47	  Say Y to add a debugfs-based thermal core testing facility.
48	  It allows test thermal zones to be created and populated
49	  with trip points in order to exercise the thermal core
50	  functionality in a controlled way.
51
52config THERMAL_EMERGENCY_POWEROFF_DELAY_MS
53	int "Emergency poweroff delay in milli-seconds"
54	default 0
55	help
56	  Thermal subsystem will issue a graceful shutdown when
57	  critical temperatures are reached using orderly_poweroff(). In
58	  case of failure of an orderly_poweroff(), the thermal emergency
59	  poweroff kicks in after a delay has elapsed and shuts down the system.
60	  This config is number of milliseconds to delay before emergency
61	  poweroff kicks in. Similarly to the critical trip point,
62	  the delay should be carefully profiled so as to give adequate
63	  time for orderly_poweroff() to finish on regular execution.
64	  If set to 0 emergency poweroff will not be supported.
65
66	  In doubt, leave as 0.
67
68config THERMAL_HWMON
69	bool
70	prompt "Expose thermal sensors as hwmon device"
71	depends on HWMON=y || HWMON=THERMAL
72	default y
73	help
74	  In case a sensor is registered with the thermal
75	  framework, this option will also register it
76	  as a hwmon. The sensor will then have the common
77	  hwmon sysfs interface.
78
79	  Say 'Y' here if you want all thermal sensors to
80	  have hwmon sysfs interface too.
81
82config THERMAL_OF
83	bool
84	prompt "APIs to parse thermal data out of device tree"
85	depends on OF
86	default y
87	help
88	  This options provides helpers to add the support to
89	  read and parse thermal data definitions out of the
90	  device tree blob.
91
92	  Say 'Y' here if you need to build thermal infrastructure
93	  based on device tree.
94
95choice
96	prompt "Default Thermal governor"
97	default THERMAL_DEFAULT_GOV_STEP_WISE
98	help
99	  This option sets which thermal governor shall be loaded at
100	  startup. If in doubt, select 'step_wise'.
101
102config THERMAL_DEFAULT_GOV_STEP_WISE
103	bool "step_wise"
104	select THERMAL_GOV_STEP_WISE
105	help
106	  Use the step_wise governor as default. This throttles the
107	  devices one step at a time.
108
109config THERMAL_DEFAULT_GOV_FAIR_SHARE
110	bool "fair_share"
111	select THERMAL_GOV_FAIR_SHARE
112	help
113	  Use the fair_share governor as default. This throttles the
114	  devices based on their 'contribution' to a zone. The
115	  contribution should be provided through platform data.
116
117config THERMAL_DEFAULT_GOV_USER_SPACE
118	bool "user_space"
119	select THERMAL_GOV_USER_SPACE
120	help
121	  The Userspace governor allows to get trip point crossed
122	  notification from the kernel via uevents. It is recommended
123	  to use the netlink interface instead which gives richer
124	  information about the thermal framework events.
125
126config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
127	bool "power_allocator"
128	depends on THERMAL_GOV_POWER_ALLOCATOR
129	help
130	  Select this if you want to control temperature based on
131	  system and device power allocation. This governor can only
132	  operate on cooling devices that implement the power API.
133
134config THERMAL_DEFAULT_GOV_BANG_BANG
135	bool "bang_bang"
136	depends on THERMAL_GOV_BANG_BANG
137	help
138	  Use the bang_bang governor as default. This throttles the
139	  devices one step at the time, taking into account the trip
140	  point hysteresis.
141
142endchoice
143
144config THERMAL_GOV_FAIR_SHARE
145	bool "Fair-share thermal governor"
146	help
147	  Enable this to manage platform thermals using fair-share governor.
148
149config THERMAL_GOV_STEP_WISE
150	bool "Step_wise thermal governor"
151	help
152	  Enable this to manage platform thermals using a simple linear
153	  governor.
154
155config THERMAL_GOV_BANG_BANG
156	bool "Bang Bang thermal governor"
157	default n
158	help
159	  Enable this to manage platform thermals using bang bang governor.
160
161	  Say 'Y' here if you want to use two point temperature regulation
162	  used for fans without throttling.  Some fan drivers depend on this
163	  governor to be enabled (e.g. acerhdf).
164
165config THERMAL_GOV_USER_SPACE
166	bool "User_space thermal governor"
167	help
168	  Enable this to let the user space manage the platform thermals.
169
170config THERMAL_GOV_POWER_ALLOCATOR
171	bool "Power allocator thermal governor"
172	depends on ENERGY_MODEL
173	help
174	  Enable this to manage platform thermals by dynamically
175	  allocating and limiting power to devices.
176
177config CPU_THERMAL
178	bool "Generic cpu cooling support"
179	depends on THERMAL_OF
180	help
181	  Enable the CPU cooling features. If the system has no active
182	  cooling device available, this option allows to use the CPU
183	  as a cooling device.
184
185if CPU_THERMAL
186
187config CPU_FREQ_THERMAL
188	bool "CPU frequency cooling device"
189	depends on CPU_FREQ
190	default y
191	help
192	  This implements the generic cpu cooling mechanism through frequency
193	  reduction. An ACPI version of this already exists
194	  (drivers/acpi/processor_thermal.c).
195	  This will be useful for platforms using the generic thermal interface
196	  and not the ACPI interface.
197
198config CPU_IDLE_THERMAL
199	bool "CPU idle cooling device"
200	depends on IDLE_INJECT
201	help
202	  This implements the CPU cooling mechanism through
203	  idle injection. This will throttle the CPU by injecting
204	  idle cycle.
205endif
206
207config DEVFREQ_THERMAL
208	bool "Generic device cooling support"
209	depends on PM_DEVFREQ
210	depends on PM_OPP
211	help
212	  This implements the generic devfreq cooling mechanism through
213	  frequency reduction for devices using devfreq.
214
215	  This will throttle the device by limiting the maximum allowed DVFS
216	  frequency corresponding to the cooling level.
217
218	  In order to use the power extensions of the cooling device,
219	  devfreq should use the simple_ondemand governor.
220
221	  If you want this support, you should say Y here.
222
223config PCIE_THERMAL
224	bool "PCIe cooling support"
225	depends on PCIEPORTBUS
226	help
227	  This implements PCIe cooling mechanism through bandwidth reduction
228	  for PCIe devices.
229
230	  If you want this support, you should say Y here.
231
232config THERMAL_EMULATION
233	bool "Thermal emulation mode support"
234	help
235	  Enable this option to make a emul_temp sysfs node in thermal zone
236	  directory to support temperature emulation. With emulation sysfs node,
237	  user can manually input temperature and test the different trip
238	  threshold behaviour for simulation purpose.
239
240	  WARNING: Be careful while enabling this option on production systems,
241	  because userland can easily disable the thermal policy by simply
242	  flooding this sysfs node with low temperature values.
243
244config THERMAL_MMIO
245	tristate "Generic Thermal MMIO driver"
246	depends on OF
247	depends on HAS_IOMEM
248	help
249	  This option enables the generic thermal MMIO driver that will use
250	  memory-mapped reads to get the temperature.  Any HW/System that
251	  allows temperature reading by a single memory-mapped reading, be it
252	  register or shared memory, is a potential candidate to work with this
253	  driver.
254
255config HISI_THERMAL
256	tristate "Hisilicon thermal driver"
257	depends on ARCH_HISI || COMPILE_TEST
258	depends on HAS_IOMEM
259	depends on OF
260	default ARCH_HISI
261	help
262	  Enable this to plug hisilicon's thermal sensor driver into the Linux
263	  thermal framework. cpufreq is used as the cooling device to throttle
264	  CPUs when the passive trip is crossed.
265
266config IMX_THERMAL
267	tristate "Temperature sensor driver for Freescale i.MX SoCs"
268	depends on ARCH_MXC || COMPILE_TEST
269	depends on NVMEM || !NVMEM
270	depends on MFD_SYSCON
271	depends on OF
272	help
273	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
274	  It supports one critical trip point and one passive trip point.  The
275	  cpufreq is used as the cooling device to throttle CPUs when the
276	  passive trip is crossed.
277
278config IMX_SC_THERMAL
279	tristate "Temperature sensor driver for NXP i.MX SoCs with System Controller"
280	depends on IMX_SCU
281	depends on OF
282	help
283	  Support for Temperature Monitor (TEMPMON) found on NXP i.MX SoCs with
284	  system controller inside, Linux kernel has to communicate with system
285	  controller via MU (message unit) IPC to get temperature from thermal
286	  sensor. It supports one critical trip point and one
287	  passive trip point for each thermal sensor.
288
289config IMX8MM_THERMAL
290	tristate "Temperature sensor driver for Freescale i.MX8MM SoC"
291	depends on ARCH_MXC || COMPILE_TEST
292	depends on OF
293	help
294	  Support for Thermal Monitoring Unit (TMU) found on Freescale i.MX8MM SoC.
295	  It supports one critical trip point and one passive trip point. The
296	  cpufreq is used as the cooling device to throttle CPUs when the passive
297	  trip is crossed.
298
299config IMX91_THERMAL
300	tristate "Temperature sensor driver for NXP i.MX91 SoC"
301	depends on ARCH_MXC || COMPILE_TEST
302	depends on OF
303	help
304	  Include one sensor and six comparators. Each of them compares the
305	  temperature value (from the sensor) against the programmable
306	  threshold values. The direction of the comparison is configurable
307	  (greater / lesser than).
308
309config K3_THERMAL
310	tristate "Texas Instruments K3 thermal support"
311	depends on ARCH_K3 || COMPILE_TEST
312	help
313	  If you say yes here you get thermal support for the Texas Instruments
314	  K3 SoC family. The current chip supported is:
315	  - AM654
316
317	  This includes temperature reading functionality.
318
319config MAX77620_THERMAL
320	tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
321	depends on MFD_MAX77620
322	depends on OF
323	help
324	  Support for die junction temperature warning alarm for Maxim
325	  Semiconductor PMIC MAX77620 device. Device generates two alarm
326	  interrupts when PMIC die temperature cross the threshold of
327	  120 degC and 140 degC.
328
329config QORIQ_THERMAL
330	tristate "QorIQ Thermal Monitoring Unit"
331	depends on THERMAL_OF && HAS_IOMEM
332	depends on PPC_E500MC || SOC_LS1021A || ARCH_LAYERSCAPE || (ARCH_MXC && ARM64) || COMPILE_TEST
333	select REGMAP_MMIO
334	help
335	  Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
336	  It supports one critical trip point and one passive trip point. The
337	  cpufreq is used as the cooling device to throttle CPUs when the
338	  passive trip is crossed.
339
340config AIROHA_THERMAL
341	tristate "Airoha thermal sensor driver"
342	depends on ARCH_AIROHA || COMPILE_TEST
343	depends on MFD_SYSCON
344	depends on OF
345	help
346	  Enable this to plug the Airoha thermal sensor driver into the Linux
347	  thermal framework.
348
349config SPEAR_THERMAL
350	tristate "SPEAr thermal sensor driver"
351	depends on PLAT_SPEAR || COMPILE_TEST
352	depends on HAS_IOMEM
353	depends on OF
354	help
355	  Enable this to plug the SPEAr thermal sensor driver into the Linux
356	  thermal framework.
357
358config SUN8I_THERMAL
359	tristate "Allwinner sun8i thermal driver"
360	depends on ARCH_SUNXI || COMPILE_TEST
361	depends on HAS_IOMEM
362	depends on NVMEM
363	depends on OF
364	depends on RESET_CONTROLLER
365	help
366	  Support for the sun8i thermal sensor driver into the Linux thermal
367	  framework.
368
369	  To compile this driver as a module, choose M here: the
370	  module will be called sun8i-thermal.
371
372config ROCKCHIP_THERMAL
373	tristate "Rockchip thermal driver"
374	depends on ARCH_ROCKCHIP || COMPILE_TEST
375	depends on RESET_CONTROLLER
376	depends on HAS_IOMEM
377	help
378	  Rockchip thermal driver provides support for Temperature sensor
379	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
380	  trip point. Cpufreq is used as the cooling device and will throttle
381	  CPUs when the Temperature crosses the passive trip point.
382
383config KIRKWOOD_THERMAL
384	tristate "Temperature sensor on Marvell Kirkwood SoCs"
385	depends on MACH_KIRKWOOD || COMPILE_TEST
386	depends on HAS_IOMEM
387	depends on OF
388	help
389	  Support for the Kirkwood thermal sensor driver into the Linux thermal
390	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
391
392config DOVE_THERMAL
393	tristate "Temperature sensor on Marvell Dove SoCs"
394	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
395	depends on HAS_IOMEM
396	depends on OF
397	help
398	  Support for the Dove thermal sensor driver in the Linux thermal
399	  framework.
400
401config DB8500_THERMAL
402	tristate "DB8500 thermal management"
403	depends on MFD_DB8500_PRCMU && OF
404	default y
405	help
406	  Adds DB8500 thermal management implementation according to the thermal
407	  management framework. A thermal zone with several trip points will be
408	  created. Cooling devices can be bound to the trip points to cool this
409	  thermal zone if trip points reached.
410
411config ARMADA_THERMAL
412	tristate "Marvell EBU Armada SoCs thermal management"
413	depends on ARCH_MVEBU || COMPILE_TEST
414	depends on HAS_IOMEM
415	depends on OF
416	help
417	  Enable this option if you want to have support for thermal management
418	  controller present in Marvell EBU Armada SoCs (370,375,XP,38x,7K,8K).
419
420config DA9062_THERMAL
421	tristate "DA9062/DA9061 Dialog Semiconductor thermal driver"
422	depends on MFD_DA9062 || COMPILE_TEST
423	depends on OF
424	help
425	  Enable this for the Dialog Semiconductor thermal sensor driver.
426	  This will report PMIC junction over-temperature for one thermal trip
427	  zone.
428	  Compatible with the DA9062 and DA9061 PMICs.
429
430menu "Mediatek thermal drivers"
431depends on ARCH_MEDIATEK || COMPILE_TEST
432source "drivers/thermal/mediatek/Kconfig"
433endmenu
434
435config AMLOGIC_THERMAL
436	tristate "Amlogic Thermal Support"
437	default ARCH_MESON
438	depends on OF && ARCH_MESON
439	help
440	  If you say yes here you get support for Amlogic Thermal
441	  for G12 SoC Family.
442
443	  This driver can also be built as a module. If so, the module will
444	  be called amlogic_thermal.
445
446menu "Intel thermal drivers"
447depends on X86 || X86_INTEL_QUARK || COMPILE_TEST
448source "drivers/thermal/intel/Kconfig"
449endmenu
450
451menu "Broadcom thermal drivers"
452depends on ARCH_BCM || ARCH_BRCMSTB || ARCH_BCM2835 || ARCH_BCM_IPROC || \
453		COMPILE_TEST
454source "drivers/thermal/broadcom/Kconfig"
455endmenu
456
457menu "Texas Instruments thermal drivers"
458depends on ARCH_HAS_BANDGAP || COMPILE_TEST
459depends on HAS_IOMEM
460source "drivers/thermal/ti-soc-thermal/Kconfig"
461endmenu
462
463menu "Samsung thermal drivers"
464depends on ARCH_EXYNOS || COMPILE_TEST
465source "drivers/thermal/samsung/Kconfig"
466endmenu
467
468menu "STMicroelectronics thermal drivers"
469depends on (ARCH_STI || ARCH_STM32) && THERMAL_OF
470source "drivers/thermal/st/Kconfig"
471endmenu
472
473source "drivers/thermal/renesas/Kconfig"
474
475source "drivers/thermal/tegra/Kconfig"
476
477config GENERIC_ADC_THERMAL
478	tristate "Generic ADC based thermal sensor"
479	depends on IIO
480	help
481	  This enabled a thermal sysfs driver for the temperature sensor
482	  which is connected to the General Purpose ADC. The ADC channel
483	  is read via IIO framework and the channel information is provided
484	  to this driver. This driver reports the temperature by reading ADC
485	  channel and converts it to temperature based on lookup table.
486
487menu "Qualcomm thermal drivers"
488depends on (ARCH_QCOM && OF) || COMPILE_TEST
489source "drivers/thermal/qcom/Kconfig"
490endmenu
491
492config UNIPHIER_THERMAL
493	tristate "Socionext UniPhier thermal driver"
494	depends on ARCH_UNIPHIER || COMPILE_TEST
495	depends on THERMAL_OF && MFD_SYSCON
496	help
497	  Enable this to plug in UniPhier on-chip PVT thermal driver into the
498	  thermal framework. The driver supports CPU thermal zone temperature
499	  reporting and a couple of trip points.
500
501config SPRD_THERMAL
502	tristate "Temperature sensor on Spreadtrum SoCs"
503	depends on ARCH_SPRD || COMPILE_TEST
504	help
505	  Support for the Spreadtrum thermal sensor driver in the Linux thermal
506	  framework.
507
508config KHADAS_MCU_FAN_THERMAL
509	tristate "Khadas MCU controller FAN cooling support"
510	depends on OF
511	depends on MFD_KHADAS_MCU
512	select MFD_CORE
513	select REGMAP
514	help
515	  If you say yes here you get support for the FAN controlled
516	  by the Microcontroller found on the Khadas VIM boards.
517
518config LOONGSON2_THERMAL
519	tristate "Loongson-2 SoC series thermal driver"
520	depends on LOONGARCH || COMPILE_TEST
521	depends on OF
522	help
523	  Support for Thermal driver found on Loongson-2 SoC series platforms.
524	  The thermal driver realizes get_temp and set_trips function, which
525	  are used to obtain the temperature of the current node and set the
526	  temperature range to trigger the interrupt. When the input temperature
527	  is higher than the high temperature threshold or lower than the low
528	  temperature threshold, the interrupt will occur.
529
530endif