xref: /linux/drivers/thermal/Kconfig (revision d1c8b0410b77f1e43f97cd22bc7e0a71a5305840)
1203d3d4aSZhang Rui#
2203d3d4aSZhang Rui# Generic thermal sysfs drivers configuration
3203d3d4aSZhang Rui#
4203d3d4aSZhang Rui
5203d3d4aSZhang Ruimenuconfig THERMAL
663c4ec90SZhang Rui	tristate "Generic Thermal sysfs driver"
7203d3d4aSZhang Rui	help
8203d3d4aSZhang Rui	  Generic Thermal Sysfs driver offers a generic mechanism for
9203d3d4aSZhang Rui	  thermal management. Usually it's made up of one or more thermal
10203d3d4aSZhang Rui	  zone and cooling device.
11543a9561SLen Brown	  Each thermal zone contains its own temperature, trip points,
12203d3d4aSZhang Rui	  cooling devices.
13203d3d4aSZhang Rui	  All platforms with ACPI thermal support can use this driver.
1463c4ec90SZhang Rui	  If you want this support, you should say Y or M here.
1516d75239SRene Herman
1672e19897SZhang Ruiif THERMAL
1772e19897SZhang Rui
1816d75239SRene Hermanconfig THERMAL_HWMON
19ab92402aSJean Delvare	bool
200dd88793SEduardo Valentin	prompt "Expose thermal sensors as hwmon device"
2116d75239SRene Herman	depends on HWMON=y || HWMON=THERMAL
22ab92402aSJean Delvare	default y
230dd88793SEduardo Valentin	help
240dd88793SEduardo Valentin	  In case a sensor is registered with the thermal
250dd88793SEduardo Valentin	  framework, this option will also register it
260dd88793SEduardo Valentin	  as a hwmon. The sensor will then have the common
270dd88793SEduardo Valentin	  hwmon sysfs interface.
280dd88793SEduardo Valentin
290dd88793SEduardo Valentin	  Say 'Y' here if you want all thermal sensors to
300dd88793SEduardo Valentin	  have hwmon sysfs interface too.
316a92c366SVincenzo Frascino
324e5e4705SEduardo Valentinconfig THERMAL_OF
334e5e4705SEduardo Valentin	bool
344e5e4705SEduardo Valentin	prompt "APIs to parse thermal data out of device tree"
354e5e4705SEduardo Valentin	depends on OF
364e5e4705SEduardo Valentin	default y
374e5e4705SEduardo Valentin	help
384e5e4705SEduardo Valentin	  This options provides helpers to add the support to
394e5e4705SEduardo Valentin	  read and parse thermal data definitions out of the
404e5e4705SEduardo Valentin	  device tree blob.
414e5e4705SEduardo Valentin
424e5e4705SEduardo Valentin	  Say 'Y' here if you need to build thermal infrastructure
434e5e4705SEduardo Valentin	  based on device tree.
444e5e4705SEduardo Valentin
45a56757afSDurgadoss Rchoice
46a56757afSDurgadoss R	prompt "Default Thermal governor"
47a56757afSDurgadoss R	default THERMAL_DEFAULT_GOV_STEP_WISE
48a56757afSDurgadoss R	help
49a56757afSDurgadoss R	  This option sets which thermal governor shall be loaded at
50a56757afSDurgadoss R	  startup. If in doubt, select 'step_wise'.
51a56757afSDurgadoss R
52a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_STEP_WISE
53a56757afSDurgadoss R	bool "step_wise"
549d185d04SZhang Rui	select THERMAL_GOV_STEP_WISE
55a56757afSDurgadoss R	help
56a56757afSDurgadoss R	  Use the step_wise governor as default. This throttles the
57a56757afSDurgadoss R	  devices one step at a time.
58a56757afSDurgadoss R
59a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_FAIR_SHARE
60a56757afSDurgadoss R	bool "fair_share"
619d185d04SZhang Rui	select THERMAL_GOV_FAIR_SHARE
62a56757afSDurgadoss R	help
63a56757afSDurgadoss R	  Use the fair_share governor as default. This throttles the
64a56757afSDurgadoss R	  devices based on their 'contribution' to a zone. The
65a56757afSDurgadoss R	  contribution should be provided through platform data.
66a56757afSDurgadoss R
67a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_USER_SPACE
68a56757afSDurgadoss R	bool "user_space"
699d185d04SZhang Rui	select THERMAL_GOV_USER_SPACE
70a56757afSDurgadoss R	help
71a56757afSDurgadoss R	  Select this if you want to let the user space manage the
72ece238feSRegid Ichira	  platform thermals.
7372e19897SZhang Rui
74a56757afSDurgadoss Rendchoice
7572e19897SZhang Rui
769d185d04SZhang Ruiconfig THERMAL_GOV_FAIR_SHARE
7772e19897SZhang Rui	bool "Fair-share thermal governor"
7872e19897SZhang Rui	help
7972e19897SZhang Rui	  Enable this to manage platform thermals using fair-share governor.
8072e19897SZhang Rui
819d185d04SZhang Ruiconfig THERMAL_GOV_STEP_WISE
8272e19897SZhang Rui	bool "Step_wise thermal governor"
8372e19897SZhang Rui	help
8472e19897SZhang Rui	  Enable this to manage platform thermals using a simple linear
85a8227948SLuka Perkov	  governor.
8672e19897SZhang Rui
879d185d04SZhang Ruiconfig THERMAL_GOV_USER_SPACE
8872e19897SZhang Rui	bool "User_space thermal governor"
8972e19897SZhang Rui	help
9072e19897SZhang Rui	  Enable this to let the user space manage the platform thermals.
9172e19897SZhang Rui
9272e19897SZhang Ruiconfig CPU_THERMAL
93bbf7fc88SZhang Rui	bool "generic cpu cooling support"
9472e19897SZhang Rui	depends on CPU_FREQ
9539d99cffSEduardo Valentin	depends on THERMAL_OF
9672e19897SZhang Rui	help
9772e19897SZhang Rui	  This implements the generic cpu cooling mechanism through frequency
98f7188b3dSEduardo Valentin	  reduction. An ACPI version of this already exists
99f7188b3dSEduardo Valentin	  (drivers/acpi/processor_thermal.c).
10072e19897SZhang Rui	  This will be useful for platforms using the generic thermal interface
10172e19897SZhang Rui	  and not the ACPI interface.
102f7188b3dSEduardo Valentin
10372e19897SZhang Rui	  If you want this support, you should say Y here.
10472e19897SZhang Rui
105e6e238c3SAmit Daniel Kachhapconfig THERMAL_EMULATION
106e6e238c3SAmit Daniel Kachhap	bool "Thermal emulation mode support"
107e6e238c3SAmit Daniel Kachhap	help
108e6e238c3SAmit Daniel Kachhap	  Enable this option to make a emul_temp sysfs node in thermal zone
109e6e238c3SAmit Daniel Kachhap	  directory to support temperature emulation. With emulation sysfs node,
110e6e238c3SAmit Daniel Kachhap	  user can manually input temperature and test the different trip
111e6e238c3SAmit Daniel Kachhap	  threshold behaviour for simulation purpose.
112e6e238c3SAmit Daniel Kachhap
1138837295aSEduardo Valentin	  WARNING: Be careful while enabling this option on production systems,
1148837295aSEduardo Valentin	  because userland can easily disable the thermal policy by simply
1158837295aSEduardo Valentin	  flooding this sysfs node with low temperature values.
1168837295aSEduardo Valentin
117ca3de46bSShawn Guoconfig IMX_THERMAL
118ca3de46bSShawn Guo	tristate "Temperature sensor driver for Freescale i.MX SoCs"
119ca3de46bSShawn Guo	depends on CPU_THERMAL
120ca3de46bSShawn Guo	depends on MFD_SYSCON
121ca3de46bSShawn Guo	depends on OF
122ca3de46bSShawn Guo	help
123ca3de46bSShawn Guo	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
124ca3de46bSShawn Guo	  It supports one critical trip point and one passive trip point.  The
125ca3de46bSShawn Guo	  cpufreq is used as the cooling device to throttle CPUs when the
126ca3de46bSShawn Guo	  passive trip is crossed.
127ca3de46bSShawn Guo
12872e19897SZhang Ruiconfig SPEAR_THERMAL
12972e19897SZhang Rui	bool "SPEAr thermal sensor driver"
13072e19897SZhang Rui	depends on PLAT_SPEAR
13172e19897SZhang Rui	depends on OF
13272e19897SZhang Rui	help
13372e19897SZhang Rui	  Enable this to plug the SPEAr thermal sensor driver into the Linux
134a8227948SLuka Perkov	  thermal framework.
13572e19897SZhang Rui
13672e19897SZhang Ruiconfig RCAR_THERMAL
13772e19897SZhang Rui	tristate "Renesas R-Car thermal driver"
138beeb5a1eSLaurent Pinchart	depends on ARCH_SHMOBILE || COMPILE_TEST
139*d1c8b041SRichard Weinberger	depends on HAS_IOMEM
14072e19897SZhang Rui	help
14172e19897SZhang Rui	  Enable this to plug the R-Car thermal sensor driver into the Linux
142a8227948SLuka Perkov	  thermal framework.
14372e19897SZhang Rui
1447060aa36SNobuhiro Iwamatsuconfig KIRKWOOD_THERMAL
1457060aa36SNobuhiro Iwamatsu	tristate "Temperature sensor on Marvell Kirkwood SoCs"
1467060aa36SNobuhiro Iwamatsu	depends on ARCH_KIRKWOOD
1477060aa36SNobuhiro Iwamatsu	depends on OF
1487060aa36SNobuhiro Iwamatsu	help
1497060aa36SNobuhiro Iwamatsu	  Support for the Kirkwood thermal sensor driver into the Linux thermal
1507060aa36SNobuhiro Iwamatsu	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
1517060aa36SNobuhiro Iwamatsu
15274ffa64cSAndrew Lunnconfig DOVE_THERMAL
15374ffa64cSAndrew Lunn	tristate "Temperature sensor on Marvell Dove SoCs"
15474ffa64cSAndrew Lunn	depends on ARCH_DOVE
15574ffa64cSAndrew Lunn	depends on OF
15674ffa64cSAndrew Lunn	help
15774ffa64cSAndrew Lunn	  Support for the Dove thermal sensor driver in the Linux thermal
15874ffa64cSAndrew Lunn	  framework.
15974ffa64cSAndrew Lunn
160aa1acb04Shongbo.zhangconfig DB8500_THERMAL
161aa1acb04Shongbo.zhang	bool "DB8500 thermal management"
162aa1acb04Shongbo.zhang	depends on ARCH_U8500
163aa1acb04Shongbo.zhang	default y
164aa1acb04Shongbo.zhang	help
165aa1acb04Shongbo.zhang	  Adds DB8500 thermal management implementation according to the thermal
166aa1acb04Shongbo.zhang	  management framework. A thermal zone with several trip points will be
167aa1acb04Shongbo.zhang	  created. Cooling devices can be bound to the trip points to cool this
168aa1acb04Shongbo.zhang	  thermal zone if trip points reached.
169aa1acb04Shongbo.zhang
170fa0d654cSEzequiel Garciaconfig ARMADA_THERMAL
171fa0d654cSEzequiel Garcia	tristate "Armada 370/XP thermal management"
172fa0d654cSEzequiel Garcia	depends on ARCH_MVEBU
173fa0d654cSEzequiel Garcia	depends on OF
174fa0d654cSEzequiel Garcia	help
175fa0d654cSEzequiel Garcia	  Enable this option if you want to have support for thermal management
176fa0d654cSEzequiel Garcia	  controller present in Armada 370 and Armada XP SoC.
177fa0d654cSEzequiel Garcia
178aa1acb04Shongbo.zhangconfig DB8500_CPUFREQ_COOLING
179aa1acb04Shongbo.zhang	tristate "DB8500 cpufreq cooling"
180aa1acb04Shongbo.zhang	depends on ARCH_U8500
181aa1acb04Shongbo.zhang	depends on CPU_THERMAL
182aa1acb04Shongbo.zhang	default y
183aa1acb04Shongbo.zhang	help
184aa1acb04Shongbo.zhang	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
185aa1acb04Shongbo.zhang	  bound to thermal zone trip points. When a trip point reached, the
186aa1acb04Shongbo.zhang	  bound cpufreq cooling device turns active to set CPU frequency low to
187aa1acb04Shongbo.zhang	  cool down the CPU.
18872e19897SZhang Rui
189d6d71ee4SJacob Panconfig INTEL_POWERCLAMP
190d6d71ee4SJacob Pan	tristate "Intel PowerClamp idle injection driver"
191d6d71ee4SJacob Pan	depends on THERMAL
192d6d71ee4SJacob Pan	depends on X86
193d6d71ee4SJacob Pan	depends on CPU_SUP_INTEL
194d6d71ee4SJacob Pan	help
195d6d71ee4SJacob Pan	  Enable this to enable Intel PowerClamp idle injection driver. This
196d6d71ee4SJacob Pan	  enforce idle time which results in more package C-state residency. The
197d6d71ee4SJacob Pan	  user interface is exposed via generic thermal framework.
198d6d71ee4SJacob Pan
199f1a18a10SSrinivas Pandruvadaconfig X86_PKG_TEMP_THERMAL
200f1a18a10SSrinivas Pandruvada	tristate "X86 package temperature thermal driver"
201b3ba0206SRandy Dunlap	depends on X86_THERMAL_VECTOR
202f1a18a10SSrinivas Pandruvada	select THERMAL_GOV_USER_SPACE
203f1a18a10SSrinivas Pandruvada	default m
204f1a18a10SSrinivas Pandruvada	help
205f1a18a10SSrinivas Pandruvada	  Enable this to register CPU digital sensor for package temperature as
206f1a18a10SSrinivas Pandruvada	  thermal zone. Each package will have its own thermal zone. There are
207f1a18a10SSrinivas Pandruvada	  two trip points which can be set by user to get notifications via thermal
208f1a18a10SSrinivas Pandruvada	  notification methods.
209f1a18a10SSrinivas Pandruvada
210925c36bbSSrinivas Pandruvadaconfig ACPI_INT3403_THERMAL
211925c36bbSSrinivas Pandruvada	tristate "ACPI INT3403 thermal driver"
212925c36bbSSrinivas Pandruvada	depends on X86 && ACPI
213925c36bbSSrinivas Pandruvada	help
21437d6a82bSZhang Rui	  Newer laptops and tablets that use ACPI may have thermal sensors
21537d6a82bSZhang Rui	  outside the core CPU/SOC for thermal safety reasons. These
21637d6a82bSZhang Rui	  temperature sensors are also exposed for the OS to use via the so
21737d6a82bSZhang Rui	  called INT3403 ACPI object. This driver will, on devices that have
21837d6a82bSZhang Rui	  such sensors, expose the temperature information from these sensors
21937d6a82bSZhang Rui	  to userspace via the normal thermal framework. This means that a wide
22037d6a82bSZhang Rui	  range of applications and GUI widgets can show this information to
22137d6a82bSZhang Rui	  the user or use this information for making decisions. For example,
22237d6a82bSZhang Rui	  the Intel Thermal Daemon can use this information to allow the user
22337d6a82bSZhang Rui	  to select his laptop to run without turning on the fans.
224925c36bbSSrinivas Pandruvada
225eb982001SEduardo Valentinmenu "Texas Instruments thermal drivers"
226eb982001SEduardo Valentinsource "drivers/thermal/ti-soc-thermal/Kconfig"
227eb982001SEduardo Valentinendmenu
228f157f596SZhang Rui
229c6821378SAmit Daniel Kachhapmenu "Samsung thermal drivers"
230c6821378SAmit Daniel Kachhapdepends on PLAT_SAMSUNG
231c6821378SAmit Daniel Kachhapsource "drivers/thermal/samsung/Kconfig"
232c6821378SAmit Daniel Kachhapendmenu
233c6821378SAmit Daniel Kachhap
23472e19897SZhang Ruiendif
235