xref: /linux/drivers/thermal/Kconfig (revision beeb5a1e0ef774d0a3e18c5a0e78c39e3e1a5389)
1203d3d4aSZhang Rui#
2203d3d4aSZhang Rui# Generic thermal sysfs drivers configuration
3203d3d4aSZhang Rui#
4203d3d4aSZhang Rui
5203d3d4aSZhang Ruimenuconfig THERMAL
663c4ec90SZhang Rui	tristate "Generic Thermal sysfs driver"
7203d3d4aSZhang Rui	help
8203d3d4aSZhang Rui	  Generic Thermal Sysfs driver offers a generic mechanism for
9203d3d4aSZhang Rui	  thermal management. Usually it's made up of one or more thermal
10203d3d4aSZhang Rui	  zone and cooling device.
11543a9561SLen Brown	  Each thermal zone contains its own temperature, trip points,
12203d3d4aSZhang Rui	  cooling devices.
13203d3d4aSZhang Rui	  All platforms with ACPI thermal support can use this driver.
1463c4ec90SZhang Rui	  If you want this support, you should say Y or M here.
1516d75239SRene Herman
1672e19897SZhang Ruiif THERMAL
1772e19897SZhang Rui
1816d75239SRene Hermanconfig THERMAL_HWMON
19ab92402aSJean Delvare	bool
200dd88793SEduardo Valentin	prompt "Expose thermal sensors as hwmon device"
2116d75239SRene Herman	depends on HWMON=y || HWMON=THERMAL
22ab92402aSJean Delvare	default y
230dd88793SEduardo Valentin	help
240dd88793SEduardo Valentin	  In case a sensor is registered with the thermal
250dd88793SEduardo Valentin	  framework, this option will also register it
260dd88793SEduardo Valentin	  as a hwmon. The sensor will then have the common
270dd88793SEduardo Valentin	  hwmon sysfs interface.
280dd88793SEduardo Valentin
290dd88793SEduardo Valentin	  Say 'Y' here if you want all thermal sensors to
300dd88793SEduardo Valentin	  have hwmon sysfs interface too.
316a92c366SVincenzo Frascino
32a56757afSDurgadoss Rchoice
33a56757afSDurgadoss R	prompt "Default Thermal governor"
34a56757afSDurgadoss R	default THERMAL_DEFAULT_GOV_STEP_WISE
35a56757afSDurgadoss R	help
36a56757afSDurgadoss R	  This option sets which thermal governor shall be loaded at
37a56757afSDurgadoss R	  startup. If in doubt, select 'step_wise'.
38a56757afSDurgadoss R
39a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_STEP_WISE
40a56757afSDurgadoss R	bool "step_wise"
419d185d04SZhang Rui	select THERMAL_GOV_STEP_WISE
42a56757afSDurgadoss R	help
43a56757afSDurgadoss R	  Use the step_wise governor as default. This throttles the
44a56757afSDurgadoss R	  devices one step at a time.
45a56757afSDurgadoss R
46a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_FAIR_SHARE
47a56757afSDurgadoss R	bool "fair_share"
489d185d04SZhang Rui	select THERMAL_GOV_FAIR_SHARE
49a56757afSDurgadoss R	help
50a56757afSDurgadoss R	  Use the fair_share governor as default. This throttles the
51a56757afSDurgadoss R	  devices based on their 'contribution' to a zone. The
52a56757afSDurgadoss R	  contribution should be provided through platform data.
53a56757afSDurgadoss R
54a56757afSDurgadoss Rconfig THERMAL_DEFAULT_GOV_USER_SPACE
55a56757afSDurgadoss R	bool "user_space"
569d185d04SZhang Rui	select THERMAL_GOV_USER_SPACE
57a56757afSDurgadoss R	help
58a56757afSDurgadoss R	  Select this if you want to let the user space manage the
59ece238feSRegid Ichira	  platform thermals.
6072e19897SZhang Rui
61a56757afSDurgadoss Rendchoice
6272e19897SZhang Rui
639d185d04SZhang Ruiconfig THERMAL_GOV_FAIR_SHARE
6472e19897SZhang Rui	bool "Fair-share thermal governor"
6572e19897SZhang Rui	help
6672e19897SZhang Rui	  Enable this to manage platform thermals using fair-share governor.
6772e19897SZhang Rui
689d185d04SZhang Ruiconfig THERMAL_GOV_STEP_WISE
6972e19897SZhang Rui	bool "Step_wise thermal governor"
7072e19897SZhang Rui	help
7172e19897SZhang Rui	  Enable this to manage platform thermals using a simple linear
72a8227948SLuka Perkov	  governor.
7372e19897SZhang Rui
749d185d04SZhang Ruiconfig THERMAL_GOV_USER_SPACE
7572e19897SZhang Rui	bool "User_space thermal governor"
7672e19897SZhang Rui	help
7772e19897SZhang Rui	  Enable this to let the user space manage the platform thermals.
7872e19897SZhang Rui
7972e19897SZhang Ruiconfig CPU_THERMAL
80bbf7fc88SZhang Rui	bool "generic cpu cooling support"
8172e19897SZhang Rui	depends on CPU_FREQ
8272e19897SZhang Rui	help
8372e19897SZhang Rui	  This implements the generic cpu cooling mechanism through frequency
84f7188b3dSEduardo Valentin	  reduction. An ACPI version of this already exists
85f7188b3dSEduardo Valentin	  (drivers/acpi/processor_thermal.c).
8672e19897SZhang Rui	  This will be useful for platforms using the generic thermal interface
8772e19897SZhang Rui	  and not the ACPI interface.
88f7188b3dSEduardo Valentin
8972e19897SZhang Rui	  If you want this support, you should say Y here.
9072e19897SZhang Rui
91e6e238c3SAmit Daniel Kachhapconfig THERMAL_EMULATION
92e6e238c3SAmit Daniel Kachhap	bool "Thermal emulation mode support"
93e6e238c3SAmit Daniel Kachhap	help
94e6e238c3SAmit Daniel Kachhap	  Enable this option to make a emul_temp sysfs node in thermal zone
95e6e238c3SAmit Daniel Kachhap	  directory to support temperature emulation. With emulation sysfs node,
96e6e238c3SAmit Daniel Kachhap	  user can manually input temperature and test the different trip
97e6e238c3SAmit Daniel Kachhap	  threshold behaviour for simulation purpose.
98e6e238c3SAmit Daniel Kachhap
998837295aSEduardo Valentin	  WARNING: Be careful while enabling this option on production systems,
1008837295aSEduardo Valentin	  because userland can easily disable the thermal policy by simply
1018837295aSEduardo Valentin	  flooding this sysfs node with low temperature values.
1028837295aSEduardo Valentin
103ca3de46bSShawn Guoconfig IMX_THERMAL
104ca3de46bSShawn Guo	tristate "Temperature sensor driver for Freescale i.MX SoCs"
105ca3de46bSShawn Guo	depends on CPU_THERMAL
106ca3de46bSShawn Guo	depends on MFD_SYSCON
107ca3de46bSShawn Guo	depends on OF
108ca3de46bSShawn Guo	help
109ca3de46bSShawn Guo	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
110ca3de46bSShawn Guo	  It supports one critical trip point and one passive trip point.  The
111ca3de46bSShawn Guo	  cpufreq is used as the cooling device to throttle CPUs when the
112ca3de46bSShawn Guo	  passive trip is crossed.
113ca3de46bSShawn Guo
11472e19897SZhang Ruiconfig SPEAR_THERMAL
11572e19897SZhang Rui	bool "SPEAr thermal sensor driver"
11672e19897SZhang Rui	depends on PLAT_SPEAR
11772e19897SZhang Rui	depends on OF
11872e19897SZhang Rui	help
11972e19897SZhang Rui	  Enable this to plug the SPEAr thermal sensor driver into the Linux
120a8227948SLuka Perkov	  thermal framework.
12172e19897SZhang Rui
12272e19897SZhang Ruiconfig RCAR_THERMAL
12372e19897SZhang Rui	tristate "Renesas R-Car thermal driver"
124*beeb5a1eSLaurent Pinchart	depends on ARCH_SHMOBILE || COMPILE_TEST
12572e19897SZhang Rui	help
12672e19897SZhang Rui	  Enable this to plug the R-Car thermal sensor driver into the Linux
127a8227948SLuka Perkov	  thermal framework.
12872e19897SZhang Rui
1297060aa36SNobuhiro Iwamatsuconfig KIRKWOOD_THERMAL
1307060aa36SNobuhiro Iwamatsu	tristate "Temperature sensor on Marvell Kirkwood SoCs"
1317060aa36SNobuhiro Iwamatsu	depends on ARCH_KIRKWOOD
1327060aa36SNobuhiro Iwamatsu	depends on OF
1337060aa36SNobuhiro Iwamatsu	help
1347060aa36SNobuhiro Iwamatsu	  Support for the Kirkwood thermal sensor driver into the Linux thermal
1357060aa36SNobuhiro Iwamatsu	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
1367060aa36SNobuhiro Iwamatsu
13774ffa64cSAndrew Lunnconfig DOVE_THERMAL
13874ffa64cSAndrew Lunn	tristate "Temperature sensor on Marvell Dove SoCs"
13974ffa64cSAndrew Lunn	depends on ARCH_DOVE
14074ffa64cSAndrew Lunn	depends on OF
14174ffa64cSAndrew Lunn	help
14274ffa64cSAndrew Lunn	  Support for the Dove thermal sensor driver in the Linux thermal
14374ffa64cSAndrew Lunn	  framework.
14474ffa64cSAndrew Lunn
145aa1acb04Shongbo.zhangconfig DB8500_THERMAL
146aa1acb04Shongbo.zhang	bool "DB8500 thermal management"
147aa1acb04Shongbo.zhang	depends on ARCH_U8500
148aa1acb04Shongbo.zhang	default y
149aa1acb04Shongbo.zhang	help
150aa1acb04Shongbo.zhang	  Adds DB8500 thermal management implementation according to the thermal
151aa1acb04Shongbo.zhang	  management framework. A thermal zone with several trip points will be
152aa1acb04Shongbo.zhang	  created. Cooling devices can be bound to the trip points to cool this
153aa1acb04Shongbo.zhang	  thermal zone if trip points reached.
154aa1acb04Shongbo.zhang
155fa0d654cSEzequiel Garciaconfig ARMADA_THERMAL
156fa0d654cSEzequiel Garcia	tristate "Armada 370/XP thermal management"
157fa0d654cSEzequiel Garcia	depends on ARCH_MVEBU
158fa0d654cSEzequiel Garcia	depends on OF
159fa0d654cSEzequiel Garcia	help
160fa0d654cSEzequiel Garcia	  Enable this option if you want to have support for thermal management
161fa0d654cSEzequiel Garcia	  controller present in Armada 370 and Armada XP SoC.
162fa0d654cSEzequiel Garcia
163aa1acb04Shongbo.zhangconfig DB8500_CPUFREQ_COOLING
164aa1acb04Shongbo.zhang	tristate "DB8500 cpufreq cooling"
165aa1acb04Shongbo.zhang	depends on ARCH_U8500
166aa1acb04Shongbo.zhang	depends on CPU_THERMAL
167aa1acb04Shongbo.zhang	default y
168aa1acb04Shongbo.zhang	help
169aa1acb04Shongbo.zhang	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
170aa1acb04Shongbo.zhang	  bound to thermal zone trip points. When a trip point reached, the
171aa1acb04Shongbo.zhang	  bound cpufreq cooling device turns active to set CPU frequency low to
172aa1acb04Shongbo.zhang	  cool down the CPU.
17372e19897SZhang Rui
174d6d71ee4SJacob Panconfig INTEL_POWERCLAMP
175d6d71ee4SJacob Pan	tristate "Intel PowerClamp idle injection driver"
176d6d71ee4SJacob Pan	depends on THERMAL
177d6d71ee4SJacob Pan	depends on X86
178d6d71ee4SJacob Pan	depends on CPU_SUP_INTEL
179d6d71ee4SJacob Pan	help
180d6d71ee4SJacob Pan	  Enable this to enable Intel PowerClamp idle injection driver. This
181d6d71ee4SJacob Pan	  enforce idle time which results in more package C-state residency. The
182d6d71ee4SJacob Pan	  user interface is exposed via generic thermal framework.
183d6d71ee4SJacob Pan
184f1a18a10SSrinivas Pandruvadaconfig X86_PKG_TEMP_THERMAL
185f1a18a10SSrinivas Pandruvada	tristate "X86 package temperature thermal driver"
186b3ba0206SRandy Dunlap	depends on X86_THERMAL_VECTOR
187f1a18a10SSrinivas Pandruvada	select THERMAL_GOV_USER_SPACE
188f1a18a10SSrinivas Pandruvada	default m
189f1a18a10SSrinivas Pandruvada	help
190f1a18a10SSrinivas Pandruvada	  Enable this to register CPU digital sensor for package temperature as
191f1a18a10SSrinivas Pandruvada	  thermal zone. Each package will have its own thermal zone. There are
192f1a18a10SSrinivas Pandruvada	  two trip points which can be set by user to get notifications via thermal
193f1a18a10SSrinivas Pandruvada	  notification methods.
194f1a18a10SSrinivas Pandruvada
195eb982001SEduardo Valentinmenu "Texas Instruments thermal drivers"
196eb982001SEduardo Valentinsource "drivers/thermal/ti-soc-thermal/Kconfig"
197eb982001SEduardo Valentinendmenu
198f157f596SZhang Rui
199c6821378SAmit Daniel Kachhapmenu "Samsung thermal drivers"
200c6821378SAmit Daniel Kachhapdepends on PLAT_SAMSUNG
201c6821378SAmit Daniel Kachhapsource "drivers/thermal/samsung/Kconfig"
202c6821378SAmit Daniel Kachhapendmenu
203c6821378SAmit Daniel Kachhap
20472e19897SZhang Ruiendif
205