1.. SPDX-License-Identifier: GPL-2.0-or-later 2 3Kernel driver e50sn12051 4======================== 5 6Supported chips: 7 8 * Delta E50SN12051 9 10 Prefix: 'e50sn12051' 11 12 Addresses scanned: - 13 14 Datasheet: 15 16 Provided by Delta upon request and NDA 17 18Description 19----------- 20 21E50SN12051 is a 600W non-isolated 1/8th brick DC-DC power module. 22 23This driver supports the E50SN12051 PMBus compliant monitor device. 24 25The device provides measurements for: 26 27* Input voltage 28* Output current 29* Output voltage 30* Temperature 31 32The driver is based on the PMBus core and exposes standard hwmon 33sysfs attributes. 34 35Sysfs attributes 36---------------- 37 38======================= ======================================================= 39curr1_label "iout1" 40curr1_crit Critical maximum current. 41 From IOUT_OC_FAULT_LIMIT register. 42curr1_crit_alarm Current critical high alarm. 43 From IOUT_OC_FAULT status. 44curr1_input Measured current. 45 From READ_IOUT register. 46curr1_max Maximum current. 47 From IOUT_OC_WARN_LIMIT register. 48curr1_max_alarm Current high alarm. 49 From IOUT_OC_WARN_LIMIT status. 50 51in1_label "vin" 52in1_alarm Input voltage alarm. 53in1_input Measured voltage. 54 From READ_VIN register. 55 56in2_label "vout1" 57in2_crit Critical maximum voltage. 58 From VOUT_OV_FAULT_LIMIT register. 59in2_crit_alarm Voltage critical high alarm. 60 From VOLTAGE_OV_FAULT status. 61in2_input Measured voltage. 62 From READ_VOUT register. 63in2_max Maximum voltage. 64 From VOUT_OV_WARN_LIMIT register. 65in2_max_alarm Voltage high alarm. 66 From VOLTAGE_OV_WARNING status. 67 68temp1_crit Critical high temperature. 69 From OT_FAULT_LIMIT register. 70temp1_crit_alarm Module temperature critical high alarm. 71 Set by comparing READ_TEMPERATURE_1 with OT_FAULT_LIMIT 72 if TEMP_OT_FAULT status is set. 73temp1_input Measured module's hot spot temperature. 74 From READ_TEMPERATURE_1 register. 75temp1_max Maximum temperature. 76 From OT_WARN_LIMIT register. 77temp1_max_alarm Module temperature high alarm. 78 Set by comparing READ_TEMPERATURE_1 with OT_WARN_LIMIT if 79 TEMP_OT_WARNING status is set. 80======================= ======================================================= 81 82