Lines Matching refs:e_dbg

116 	e_dbg("Programming MAC Address into RAR[0]\n");  in e1000e_init_rx_addrs()
121 e_dbg("Clearing RAR[1-%u]\n", rar_count - 1); in e1000e_init_rx_addrs()
156 e_dbg("NVM Read Error\n"); in e1000_check_alt_mac_addr_generic()
171 e_dbg("NVM Read Error\n"); in e1000_check_alt_mac_addr_generic()
181 e_dbg("Ignoring Alternate Mac Address with MC bit set\n"); in e1000_check_alt_mac_addr_generic()
454 e_dbg("Error configuring flow control\n"); in e1000e_check_for_copper_link()
496 e_dbg("NOT Rx'ing /C/, disable AutoNeg and force link.\n"); in e1000e_check_for_fiber_link()
509 e_dbg("Error configuring flow control\n"); in e1000e_check_for_fiber_link()
518 e_dbg("Rx'ing /C/, enable AutoNeg and stop forcing link.\n"); in e1000e_check_for_fiber_link()
559 e_dbg("NOT Rx'ing /C/, disable AutoNeg and force link.\n"); in e1000e_check_for_serdes_link()
572 e_dbg("Error configuring flow control\n"); in e1000e_check_for_serdes_link()
581 e_dbg("Rx'ing /C/, enable AutoNeg and stop forcing link.\n"); in e1000e_check_for_serdes_link()
597 e_dbg("SERDES: Link up - forced.\n"); in e1000e_check_for_serdes_link()
601 e_dbg("SERDES: Link down - force failed.\n"); in e1000e_check_for_serdes_link()
614 e_dbg("SERDES: Link up - autoneg completed successfully.\n"); in e1000e_check_for_serdes_link()
617 e_dbg("SERDES: Link down - invalid codewords detected in autoneg.\n"); in e1000e_check_for_serdes_link()
621 e_dbg("SERDES: Link down - no sync.\n"); in e1000e_check_for_serdes_link()
625 e_dbg("SERDES: Link down - autoneg failed\n"); in e1000e_check_for_serdes_link()
655 e_dbg("NVM Read Error\n"); in e1000_set_default_fc_generic()
703 e_dbg("After fix-ups FlowControl is now = %x\n", hw->fc.current_mode); in e1000e_setup_link_generic()
715 e_dbg("Initializing the Flow Control address, type and timer regs\n"); in e1000e_setup_link_generic()
781 e_dbg("Flow control param set incorrectly\n"); in e1000_commit_fc_settings_generic()
817 e_dbg("Never got a valid link from auto-neg!!!\n"); in e1000_poll_fiber_serdes_link_generic()
826 e_dbg("Error while checking for link\n"); in e1000_poll_fiber_serdes_link_generic()
832 e_dbg("Valid Link Found\n"); in e1000_poll_fiber_serdes_link_generic()
867 e_dbg("Auto-negotiation enabled\n"); in e1000e_setup_fiber_serdes_link()
881 e_dbg("No signal detected\n"); in e1000e_setup_fiber_serdes_link()
975 e_dbg("hw->fc.current_mode = %u\n", hw->fc.current_mode); in e1000e_force_mac_fc()
993 e_dbg("Flow control param set incorrectly\n"); in e1000e_force_mac_fc()
1034 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1056 e_dbg("Copper PHY and Auto Neg has not completed.\n"); in e1000e_config_fc_after_link_up()
1116 e_dbg("Flow Control = FULL.\n"); in e1000e_config_fc_after_link_up()
1119 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1134 e_dbg("Flow Control = Tx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1148 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1154 e_dbg("Flow Control = NONE.\n"); in e1000e_config_fc_after_link_up()
1163 e_dbg("Error getting link speed and duplex\n"); in e1000e_config_fc_after_link_up()
1175 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1193 e_dbg("PCS Auto Neg has not completed.\n"); in e1000e_config_fc_after_link_up()
1249 e_dbg("Flow Control = FULL.\n"); in e1000e_config_fc_after_link_up()
1252 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1267 e_dbg("Flow Control = Tx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1281 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1287 e_dbg("Flow Control = NONE.\n"); in e1000e_config_fc_after_link_up()
1299 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1334 e_dbg("%u Mbps, %s Duplex\n", in e1000e_get_speed_and_duplex_copper()
1382 e_dbg("Driver can't access device - SMBI bit is set.\n"); in e1000e_get_hw_semaphore()
1401 e_dbg("Driver can't access the NVM\n"); in e1000e_get_hw_semaphore()
1441 e_dbg("Auto read by HW from NVM has not completed.\n"); in e1000e_get_auto_rd_done()
1462 e_dbg("NVM Read Error\n"); in e1000e_valid_led_default()
1725 e_dbg("Master requests are pending.\n"); in e1000e_disable_pcie_master()
1743 e_dbg("Not in Adaptive IFS mode!\n"); in e1000e_reset_adaptive()
1769 e_dbg("Not in Adaptive IFS mode!\n"); in e1000e_update_adaptive()