#
2a1fd0ff |
| 28-Jan-2019 |
Peter Tribble <peter.tribble@gmail.com> |
10318 Remove starfire support Reviewed by: Andy Stormont <astormont@racktopsystems.com> Reviewed by: Andy Fiddaman <af@citrus-it.net> Approved by: Dan McDonald <danmcd@joyent.com>
|
#
6a634c9d |
| 19-Aug-2010 |
Richard Lowe <richlowe@richlowe.net> |
merge with onnv_147 Reviewed by: garrett@nexenta.com Approved by: garrett@nexenta.com
|
#
f9e0b1dc |
| 10-Jul-2010 |
Alexandre Chartre <Alexandre.Chartre@oracle.com> |
6961910 active guest flag becomes '-t----' if a cpu is added after cpu0 was removed
|
#
183ef8a1 |
| 26-Mar-2010 |
Haik Aftandilian <Haik.Aftandilian@Sun.COM> |
6908683 cooperative guest migration panic in cmt_balance
|
#
2f0fcb93 |
| 27-Sep-2008 |
Jason Beloro <Jason.Beloro@Sun.COM> |
PSARC/2007/003 Solaris Support for the Rock Processor 6368478 Solaris needs to support the Rock processor 6440653 stores to sun4v error queue head registers are missing a membar #Sync 6639717 FLUSH i
PSARC/2007/003 Solaris Support for the Rock Processor 6368478 Solaris needs to support the Rock processor 6440653 stores to sun4v error queue head registers are missing a membar #Sync 6639717 FLUSH instruction used more than necessary in sun4v
show more ...
|
#
924db11b |
| 13-Nov-2007 |
jc25722 <none@none> |
6626392 MPO software will sometimes place DR'd vcpu's in the wrong lgroup, sometimes causing a Panic
|
#
1a7b528f |
| 05-Sep-2007 |
jc25722 <none@none> |
6598310 Basic CPU DR sequence trips over an assert in pg_cmt_cpu_init()
|
#
68afbec1 |
| 17-Aug-2007 |
mh27603 <none@none> |
6587576 cpu_info kstat is returning garbage in supported_frequencies_Hz
|
#
22e19ac1 |
| 02-Aug-2007 |
jm22469 <none@none> |
6527622 Attempt to store boot command variable during a reboot can time out 6501039 rebooting multiple guests continuously causes a reboot thread to hang
|
#
cf74e62b |
| 24-Jul-2007 |
mh27603 <none@none> |
6584239 CPU power management additions to processor_info_t potentially break processor_info() consumers.
|
#
ad8d2eb8 |
| 17-Jul-2007 |
zx151605 <none@none> |
6473224 ncpunode unused in sun4v kernel
|
#
5cff7825 |
| 16-Jul-2007 |
mh27603 <none@none> |
PSARC/2004/826 Opteron Athlon64 Frequency Management 6358066 PSARC/2004/826 Opteron Athlon64 Frequency Management 6512756 Solaris should support Intel's Enhanced Speedstep 6335616 AMD64 CPU PwrMgmt n
PSARC/2004/826 Opteron Athlon64 Frequency Management 6358066 PSARC/2004/826 Opteron Athlon64 Frequency Management 6512756 Solaris should support Intel's Enhanced Speedstep 6335616 AMD64 CPU PwrMgmt needs Notify/_PPC for changes in P-states
--HG-- rename : usr/src/uts/sun4u/io/us_drv.c => usr/src/uts/common/io/cpudrv.c rename : usr/src/uts/sun4u/io/ppm/ppm.c => usr/src/uts/common/io/ppm/ppm.c rename : usr/src/uts/sun4u/io/ppm/ppm_subr.c => usr/src/uts/common/io/ppm/ppm_subr.c rename : usr/src/uts/sun4u/sys/us_drv.h => usr/src/uts/common/sys/cpudrv.h rename : usr/src/uts/sun4u/sys/ppmvar.h => usr/src/uts/common/sys/ppmvar.h rename : usr/src/uts/sun4u/io/ppm.c => usr/src/uts/sun4u/io/ppm_xgsubr.c
show more ...
|
#
459190a5 |
| 11-May-2007 |
rsmaeda <none@none> |
6552083 pg_cmt_cpu_init() assert failed during CPU DR on Huron
|
#
982b9107 |
| 17-Apr-2007 |
jb145095 <none@none> |
6479998 CPU DR should not panic the system on memory allocation failure
|
#
3b890a5b |
| 17-Dec-2006 |
jb145095 <none@none> |
FWARC/2006/473 sun4v guest state API update FWARC/2006/542 Guest State Supported CIF 6383225 Solaris does not send guest state to alom
|
#
f273041f |
| 21-Oct-2006 |
jm22469 <none@none> |
FWARC 2006/545 max-vcpu and mondo-latency MD properties 6469894 xcall timeouts should be derived from the machine description
|
#
1ae08745 |
| 17-May-2006 |
heppo <none@none> |
FWARC 2005/633 Project Q Logial Domaining Umbrella FWARC 2005/739 sun4v channels FWARC 2006/055 Domain Services FWARC 2006/072 sun4v virtual devices machine description data FWARC 2006/074 sun4v inte
FWARC 2005/633 Project Q Logial Domaining Umbrella FWARC 2005/739 sun4v channels FWARC 2006/055 Domain Services FWARC 2006/072 sun4v virtual devices machine description data FWARC 2006/074 sun4v interrupt cookies FWARC 2006/075 Channel devices, Virtual Disk client and server bindings FWARC 2006/076 Virtual Network Client and switch Bindings FWARC 2006/081 Virtual Logical Domain Channel (vldc) Bindings FWARC 2006/086 LDOM variables FWARC 2006/105 LDOM support for NCP FWARC 2006/110 Domain Services MD node and other misc properties FWARC 2006/117 Virtual Console Concentrator Bindings FWARC 2006/135 sun4v channel console packets FWARC 2006/140 sun4v channels transport protocol FWARC 2006/141 FMA Domain Services FWARC 2006/174 NCS HV Update FWARC 2006/184 sun4v channels shared memory FWARC 2006/195 Virtual IO Communication Protocol PSARC 2006/152 Logical Domain Channels Transport API 6272074 Need interface to determine execution unit sharing. 6354556 Add machine description kernel framework support 6391870 LDoms v1.0 Solaris Changes
show more ...
|
#
7c478bd9 |
| 14-Jun-2005 |
stevel@tonic-gate <none@none> |
OpenSolaris Launch
|