xref: /titanic_53/usr/src/cmd/picl/plugins/sun4u/snowbird/conf/SUNW,Netra-CP2300.conf (revision 7c478bd95313f5f23a4c958a745db2134aa03244)
1#
2# CDDL HEADER START
3#
4# The contents of this file are subject to the terms of the
5# Common Development and Distribution License, Version 1.0 only
6# (the "License").  You may not use this file except in compliance
7# with the License.
8#
9# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
10# or http://www.opensolaris.org/os/licensing.
11# See the License for the specific language governing permissions
12# and limitations under the License.
13#
14# When distributing Covered Code, include this CDDL HEADER in each
15# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
16# If applicable, add the following below this CDDL HEADER, with the
17# fields enclosed by brackets "[]" replaced with your own identifying
18# information: Portions Copyright [yyyy] [name of copyright owner]
19#
20# CDDL HEADER END
21#
22#
23# Copyright 2004 Sun Microsystems, Inc.  All rights reserved.
24# Use is subject to license terms.
25#
26#pragma ident	"%Z%%M%	%I%	%E% SMI"
27VERSION 1.0
28
29NODE CPU location
30	PROP State string r 0 "connected"
31	PROP SlotType string r 0 "pci"
32	PROP Label string r 0 "CPU"
33	PROP bus-addr string r 0 "1,1"
34	PROP devfs-path string r 0 "/pci@1f,0"
35	PROP PdevProbePath string r 0 "/pci@1f,0"
36	NODE CPU fru
37		PROP FRUType string r 0 "bridge/fhs"
38		PROP State string r 0 "configured"
39		PROP Condition string r 0 "unknown"
40		PROP AdminLock string rw 0 "disabled"
41		NODE PMC-1 location
42			PROP SlotType string r 0 "pci"
43			PROP Label string r 0 "PMC-A"
44			PROP bus-addr string r 0 "0x1"
45			PROP GeoAddr uint r 1 1
46			PROP devfs-path string r 0 "/pci@1f,0/pci@1"
47		ENDNODE
48		NODE PMC-2 location
49			PROP SlotType string r 0 "pci"
50			PROP Label string r 0 "PMC-B"
51			PROP bus-addr string r 0 "0x2"
52			PROP GeoAddr uint r 1 2
53			PROP devfs-path string r 0 "/pci@1f,0/pci@1"
54		ENDNODE
55		NODE su0 port
56			PROP Label string r 0 "COM"
57			PROP bus-addr string r 0 "0,3f8"
58			PROP GeoAddr uint r 1 1
59			PROP PortType string r 0 "serial"
60			PROP devfs-path string r 0 "/pci@1f,0/pci@1,1/isa@7"
61		ENDNODE
62		NODE dmfe0 port
63			PROP Label string r 0 "ETHERNET A"
64			PROP bus-addr string r 0 "1"
65			PROP GeoAddr uint r 1 1
66			PROP PortType string r 0 "network"
67			PROP devfs-path string r 0 "/pci@1f,0/pci@1,1"
68		ENDNODE
69
70		NODE dmfe1 port
71			PROP Label string r 0 "ETHERNET B"
72			PROP bus-addr string r 0 "2"
73			PROP GeoAddr uint r 1 2
74			PROP PortType string r 0 "network"
75			PROP devfs-path string r 0 "/pci@1f,0/pci@1,1"
76		ENDNODE
77	ENDNODE
78ENDNODE
79NODE RTM location
80	PROP Label string r 0 "RTM"
81	PROP State string r 0 "empty"
82	PROP SlotType string r 0 "rtm"
83ENDNODE
84