1[ 2 { 3 "EventCode": "0x100FE", 4 "EventName": "PM_INST_CMPL", 5 "BriefDescription": "PowerPC instruction completed." 6 }, 7 { 8 "EventCode": "0x1000A", 9 "EventName": "PM_PMC3_REWIND", 10 "BriefDescription": "The speculative event selected for PMC3 rewinds and the counter for PMC3 is not charged." 11 }, 12 { 13 "EventCode": "0x10010", 14 "EventName": "PM_PMC4_OVERFLOW", 15 "BriefDescription": "The event selected for PMC4 caused the event counter to overflow." 16 }, 17 { 18 "EventCode": "0x1001C", 19 "EventName": "PM_ULTRAVISOR_INST_CMPL", 20 "BriefDescription": "PowerPC instruction completed while the thread was in ultravisor state." 21 }, 22 { 23 "EventCode": "0x100F0", 24 "EventName": "PM_CYC", 25 "BriefDescription": "Processor cycles." 26 }, 27 { 28 "EventCode": "0x10020", 29 "EventName": "PM_PMC4_REWIND", 30 "BriefDescription": "The speculative event selected for PMC4 rewinds and the counter for PMC4 is not charged." 31 }, 32 { 33 "EventCode": "0x10022", 34 "EventName": "PM_PMC2_SAVED", 35 "BriefDescription": "The conditions for the speculative event selected for PMC2 are met and PMC2 is charged." 36 }, 37 { 38 "EventCode": "0x10024", 39 "EventName": "PM_PMC5_OVERFLOW", 40 "BriefDescription": "The event selected for PMC5 caused the event counter to overflow." 41 }, 42 { 43 "EventCode": "0x1002A", 44 "EventName": "PM_PMC3_HELD_CYC", 45 "BriefDescription": "Cycles when the speculative counter for PMC3 is frozen." 46 }, 47 { 48 "EventCode": "0x1F15E", 49 "EventName": "PM_MRK_START_PROBE_NOP_CMPL", 50 "BriefDescription": "Marked Start probe nop (AND R0,R0,R0) completed." 51 }, 52 { 53 "EventCode": "0x1006C", 54 "EventName": "PM_RUN_CYC_ST_MODE", 55 "BriefDescription": "Cycles when the run latch is set and the core is in ST mode." 56 }, 57 { 58 "EventCode": "0x101E8", 59 "EventName": "PM_THRESH_EXC_256", 60 "BriefDescription": "Threshold counter exceeded a count of 256." 61 }, 62 { 63 "EventCode": "0x101EC", 64 "EventName": "PM_THRESH_MET", 65 "BriefDescription": "Threshold exceeded." 66 }, 67 { 68 "EventCode": "0x100FA", 69 "EventName": "PM_RUN_LATCH_ANY_THREAD_CYC", 70 "BriefDescription": "Cycles when at least one thread has the run latch set." 71 }, 72 { 73 "EventCode": "0x2000A", 74 "EventName": "PM_HYPERVISOR_CYC", 75 "BriefDescription": "Cycles when the thread is in Hypervisor state. MSR[S HV PR]=010." 76 }, 77 { 78 "EventCode": "0x2000C", 79 "EventName": "PM_RUN_LATCH_ALL_THREADS_CYC", 80 "BriefDescription": "Cycles when the run latch is set for all threads." 81 }, 82 { 83 "EventCode": "0x20010", 84 "EventName": "PM_PMC1_OVERFLOW", 85 "BriefDescription": "The event selected for PMC1 caused the event counter to overflow." 86 }, 87 { 88 "EventCode": "0x2006C", 89 "EventName": "PM_RUN_CYC_SMT4_MODE", 90 "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT4 mode." 91 }, 92 { 93 "EventCode": "0x201E6", 94 "EventName": "PM_THRESH_EXC_32", 95 "BriefDescription": "Threshold counter exceeded a value of 32." 96 }, 97 { 98 "EventCode": "0x201E8", 99 "EventName": "PM_THRESH_EXC_512", 100 "BriefDescription": "Threshold counter exceeded a value of 512." 101 }, 102 { 103 "EventCode": "0x200F4", 104 "EventName": "PM_RUN_CYC", 105 "BriefDescription": "Processor cycles gated by the run latch." 106 }, 107 { 108 "EventCode": "0x200F8", 109 "EventName": "PM_EXT_INT", 110 "BriefDescription": "Cycles an external interrupt was active." 111 }, 112 { 113 "EventCode": "0x30010", 114 "EventName": "PM_PMC2_OVERFLOW", 115 "BriefDescription": "The event selected for PMC2 caused the event counter to overflow." 116 }, 117 { 118 "EventCode": "0x30020", 119 "EventName": "PM_PMC2_REWIND", 120 "BriefDescription": "The speculative event selected for PMC2 rewinds and the counter for PMC2 is not charged." 121 }, 122 { 123 "EventCode": "0x30022", 124 "EventName": "PM_PMC4_SAVED", 125 "BriefDescription": "The conditions for the speculative event selected for PMC4 are met and PMC4 is charged." 126 }, 127 { 128 "EventCode": "0x30024", 129 "EventName": "PM_PMC6_OVERFLOW", 130 "BriefDescription": "The event selected for PMC6 caused the event counter to overflow." 131 }, 132 { 133 "EventCode": "0x3405A", 134 "EventName": "PM_PRIVILEGED_INST_CMPL", 135 "BriefDescription": "PowerPC instruction completed while the thread was in Privileged state." 136 }, 137 { 138 "EventCode": "0x3006C", 139 "EventName": "PM_RUN_CYC_SMT2_MODE", 140 "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT2 mode." 141 }, 142 { 143 "EventCode": "0x301E8", 144 "EventName": "PM_THRESH_EXC_64", 145 "BriefDescription": "Threshold counter exceeded a value of 64." 146 }, 147 { 148 "EventCode": "0x301EA", 149 "EventName": "PM_THRESH_EXC_1024", 150 "BriefDescription": "Threshold counter exceeded a value of 1024." 151 }, 152 { 153 "EventCode": "0x40010", 154 "EventName": "PM_PMC3_OVERFLOW", 155 "BriefDescription": "The event selected for PMC3 caused the event counter to overflow." 156 }, 157 { 158 "EventCode": "0x40114", 159 "EventName": "PM_MRK_START_PROBE_NOP_DISP", 160 "BriefDescription": "Marked Start probe nop dispatched. Instruction AND R0,R0,R0." 161 }, 162 { 163 "EventCode": "0x4D010", 164 "EventName": "PM_PMC1_SAVED", 165 "BriefDescription": "The conditions for the speculative event selected for PMC1 are met and PMC1 is charged." 166 }, 167 { 168 "EventCode": "0x4D012", 169 "EventName": "PM_PMC3_SAVED", 170 "BriefDescription": "The conditions for the speculative event selected for PMC3 are met and PMC3 is charged." 171 }, 172 { 173 "EventCode": "0x4D022", 174 "EventName": "PM_HYPERVISOR_INST_CMPL", 175 "BriefDescription": "PowerPC instruction completed while the thread was in hypervisor state." 176 }, 177 { 178 "EventCode": "0x4D026", 179 "EventName": "PM_ULTRAVISOR_CYC", 180 "BriefDescription": "Cycles when the thread is in Ultravisor state. MSR[S HV PR]=110." 181 }, 182 { 183 "EventCode": "0x4D028", 184 "EventName": "PM_PRIVILEGED_CYC", 185 "BriefDescription": "Cycles when the thread is in Privileged state. MSR[S HV PR]=x00." 186 }, 187 { 188 "EventCode": "0x4D02C", 189 "EventName": "PM_PMC1_REWIND", 190 "BriefDescription": "The speculative event selected for PMC1 rewinds and the counter for PMC1 is not charged." 191 }, 192 { 193 "EventCode": "0x40030", 194 "EventName": "PM_INST_FIN", 195 "BriefDescription": "Instruction finished." 196 }, 197 { 198 "EventCode": "0x40134", 199 "EventName": "PM_MRK_INST_TIMEO", 200 "BriefDescription": "Marked instruction finish timeout (instruction was lost)." 201 }, 202 { 203 "EventCode": "0x401EA", 204 "EventName": "PM_THRESH_EXC_128", 205 "BriefDescription": "Threshold counter exceeded a value of 128." 206 }, 207 { 208 "EventCode": "0x500FA", 209 "EventName": "PM_RUN_INST_CMPL", 210 "BriefDescription": "PowerPC instruction completed while the run latch is set." 211 } 212] 213