xref: /linux/net/mac80211/agg-tx.c (revision e6a901a00822659181c93c86d8bbc2a17779fddc)
1 // SPDX-License-Identifier: GPL-2.0-only
2 /*
3  * HT handling
4  *
5  * Copyright 2003, Jouni Malinen <jkmaline@cc.hut.fi>
6  * Copyright 2002-2005, Instant802 Networks, Inc.
7  * Copyright 2005-2006, Devicescape Software, Inc.
8  * Copyright 2006-2007	Jiri Benc <jbenc@suse.cz>
9  * Copyright 2007, Michael Wu <flamingice@sourmilk.net>
10  * Copyright 2007-2010, Intel Corporation
11  * Copyright(c) 2015-2017 Intel Deutschland GmbH
12  * Copyright (C) 2018 - 2023 Intel Corporation
13  */
14 
15 #include <linux/ieee80211.h>
16 #include <linux/slab.h>
17 #include <linux/export.h>
18 #include <net/mac80211.h>
19 #include "ieee80211_i.h"
20 #include "driver-ops.h"
21 #include "wme.h"
22 
23 /**
24  * DOC: TX A-MPDU aggregation
25  *
26  * Aggregation on the TX side requires setting the hardware flag
27  * %IEEE80211_HW_AMPDU_AGGREGATION. The driver will then be handed
28  * packets with a flag indicating A-MPDU aggregation. The driver
29  * or device is responsible for actually aggregating the frames,
30  * as well as deciding how many and which to aggregate.
31  *
32  * When TX aggregation is started by some subsystem (usually the rate
33  * control algorithm would be appropriate) by calling the
34  * ieee80211_start_tx_ba_session() function, the driver will be
35  * notified via its @ampdu_action function, with the
36  * %IEEE80211_AMPDU_TX_START action.
37  *
38  * In response to that, the driver is later required to call the
39  * ieee80211_start_tx_ba_cb_irqsafe() function, which will really
40  * start the aggregation session after the peer has also responded.
41  * If the peer responds negatively, the session will be stopped
42  * again right away. Note that it is possible for the aggregation
43  * session to be stopped before the driver has indicated that it
44  * is done setting it up, in which case it must not indicate the
45  * setup completion.
46  *
47  * Also note that, since we also need to wait for a response from
48  * the peer, the driver is notified of the completion of the
49  * handshake by the %IEEE80211_AMPDU_TX_OPERATIONAL action to the
50  * @ampdu_action callback.
51  *
52  * Similarly, when the aggregation session is stopped by the peer
53  * or something calling ieee80211_stop_tx_ba_session(), the driver's
54  * @ampdu_action function will be called with the action
55  * %IEEE80211_AMPDU_TX_STOP. In this case, the call must not fail,
56  * and the driver must later call ieee80211_stop_tx_ba_cb_irqsafe().
57  * Note that the sta can get destroyed before the BA tear down is
58  * complete.
59  */
60 
61 static void ieee80211_send_addba_request(struct ieee80211_sub_if_data *sdata,
62 					 const u8 *da, u16 tid,
63 					 u8 dialog_token, u16 start_seq_num,
64 					 u16 agg_size, u16 timeout)
65 {
66 	struct ieee80211_local *local = sdata->local;
67 	struct sk_buff *skb;
68 	struct ieee80211_mgmt *mgmt;
69 	u16 capab;
70 
71 	skb = dev_alloc_skb(sizeof(*mgmt) + local->hw.extra_tx_headroom);
72 
73 	if (!skb)
74 		return;
75 
76 	skb_reserve(skb, local->hw.extra_tx_headroom);
77 	mgmt = skb_put_zero(skb, 24);
78 	memcpy(mgmt->da, da, ETH_ALEN);
79 	memcpy(mgmt->sa, sdata->vif.addr, ETH_ALEN);
80 	if (sdata->vif.type == NL80211_IFTYPE_AP ||
81 	    sdata->vif.type == NL80211_IFTYPE_AP_VLAN ||
82 	    sdata->vif.type == NL80211_IFTYPE_MESH_POINT)
83 		memcpy(mgmt->bssid, sdata->vif.addr, ETH_ALEN);
84 	else if (sdata->vif.type == NL80211_IFTYPE_STATION)
85 		memcpy(mgmt->bssid, sdata->vif.cfg.ap_addr, ETH_ALEN);
86 	else if (sdata->vif.type == NL80211_IFTYPE_ADHOC)
87 		memcpy(mgmt->bssid, sdata->u.ibss.bssid, ETH_ALEN);
88 
89 	mgmt->frame_control = cpu_to_le16(IEEE80211_FTYPE_MGMT |
90 					  IEEE80211_STYPE_ACTION);
91 
92 	skb_put(skb, 1 + sizeof(mgmt->u.action.u.addba_req));
93 
94 	mgmt->u.action.category = WLAN_CATEGORY_BACK;
95 	mgmt->u.action.u.addba_req.action_code = WLAN_ACTION_ADDBA_REQ;
96 
97 	mgmt->u.action.u.addba_req.dialog_token = dialog_token;
98 	capab = IEEE80211_ADDBA_PARAM_AMSDU_MASK;
99 	capab |= IEEE80211_ADDBA_PARAM_POLICY_MASK;
100 	capab |= u16_encode_bits(tid, IEEE80211_ADDBA_PARAM_TID_MASK);
101 	capab |= u16_encode_bits(agg_size, IEEE80211_ADDBA_PARAM_BUF_SIZE_MASK);
102 
103 	mgmt->u.action.u.addba_req.capab = cpu_to_le16(capab);
104 
105 	mgmt->u.action.u.addba_req.timeout = cpu_to_le16(timeout);
106 	mgmt->u.action.u.addba_req.start_seq_num =
107 					cpu_to_le16(start_seq_num << 4);
108 
109 	ieee80211_tx_skb_tid(sdata, skb, tid, -1);
110 }
111 
112 void ieee80211_send_bar(struct ieee80211_vif *vif, u8 *ra, u16 tid, u16 ssn)
113 {
114 	struct ieee80211_sub_if_data *sdata = vif_to_sdata(vif);
115 	struct ieee80211_local *local = sdata->local;
116 	struct sk_buff *skb;
117 	struct ieee80211_bar *bar;
118 	u16 bar_control = 0;
119 
120 	skb = dev_alloc_skb(sizeof(*bar) + local->hw.extra_tx_headroom);
121 	if (!skb)
122 		return;
123 
124 	skb_reserve(skb, local->hw.extra_tx_headroom);
125 	bar = skb_put_zero(skb, sizeof(*bar));
126 	bar->frame_control = cpu_to_le16(IEEE80211_FTYPE_CTL |
127 					 IEEE80211_STYPE_BACK_REQ);
128 	memcpy(bar->ra, ra, ETH_ALEN);
129 	memcpy(bar->ta, sdata->vif.addr, ETH_ALEN);
130 	bar_control |= (u16)IEEE80211_BAR_CTRL_ACK_POLICY_NORMAL;
131 	bar_control |= (u16)IEEE80211_BAR_CTRL_CBMTID_COMPRESSED_BA;
132 	bar_control |= (u16)(tid << IEEE80211_BAR_CTRL_TID_INFO_SHIFT);
133 	bar->control = cpu_to_le16(bar_control);
134 	bar->start_seq_num = cpu_to_le16(ssn);
135 
136 	IEEE80211_SKB_CB(skb)->flags |= IEEE80211_TX_INTFL_DONT_ENCRYPT |
137 					IEEE80211_TX_CTL_REQ_TX_STATUS;
138 	ieee80211_tx_skb_tid(sdata, skb, tid, -1);
139 }
140 EXPORT_SYMBOL(ieee80211_send_bar);
141 
142 void ieee80211_assign_tid_tx(struct sta_info *sta, int tid,
143 			     struct tid_ampdu_tx *tid_tx)
144 {
145 	lockdep_assert_wiphy(sta->local->hw.wiphy);
146 	lockdep_assert_held(&sta->lock);
147 	rcu_assign_pointer(sta->ampdu_mlme.tid_tx[tid], tid_tx);
148 }
149 
150 /*
151  * When multiple aggregation sessions on multiple stations
152  * are being created/destroyed simultaneously, we need to
153  * refcount the global queue stop caused by that in order
154  * to not get into a situation where one of the aggregation
155  * setup or teardown re-enables queues before the other is
156  * ready to handle that.
157  *
158  * These two functions take care of this issue by keeping
159  * a global "agg_queue_stop" refcount.
160  */
161 static void __acquires(agg_queue)
162 ieee80211_stop_queue_agg(struct ieee80211_sub_if_data *sdata, int tid)
163 {
164 	int queue = sdata->vif.hw_queue[ieee80211_ac_from_tid(tid)];
165 
166 	/* we do refcounting here, so don't use the queue reason refcounting */
167 
168 	if (atomic_inc_return(&sdata->local->agg_queue_stop[queue]) == 1)
169 		ieee80211_stop_queue_by_reason(
170 			&sdata->local->hw, queue,
171 			IEEE80211_QUEUE_STOP_REASON_AGGREGATION,
172 			false);
173 	__acquire(agg_queue);
174 }
175 
176 static void __releases(agg_queue)
177 ieee80211_wake_queue_agg(struct ieee80211_sub_if_data *sdata, int tid)
178 {
179 	int queue = sdata->vif.hw_queue[ieee80211_ac_from_tid(tid)];
180 
181 	if (atomic_dec_return(&sdata->local->agg_queue_stop[queue]) == 0)
182 		ieee80211_wake_queue_by_reason(
183 			&sdata->local->hw, queue,
184 			IEEE80211_QUEUE_STOP_REASON_AGGREGATION,
185 			false);
186 	__release(agg_queue);
187 }
188 
189 static void
190 ieee80211_agg_stop_txq(struct sta_info *sta, int tid)
191 {
192 	struct ieee80211_txq *txq = sta->sta.txq[tid];
193 	struct ieee80211_sub_if_data *sdata;
194 	struct fq *fq;
195 	struct txq_info *txqi;
196 
197 	if (!txq)
198 		return;
199 
200 	txqi = to_txq_info(txq);
201 	sdata = vif_to_sdata(txq->vif);
202 	fq = &sdata->local->fq;
203 
204 	/* Lock here to protect against further seqno updates on dequeue */
205 	spin_lock_bh(&fq->lock);
206 	set_bit(IEEE80211_TXQ_STOP, &txqi->flags);
207 	spin_unlock_bh(&fq->lock);
208 }
209 
210 static void
211 ieee80211_agg_start_txq(struct sta_info *sta, int tid, bool enable)
212 {
213 	struct ieee80211_txq *txq = sta->sta.txq[tid];
214 	struct txq_info *txqi;
215 
216 	lockdep_assert_wiphy(sta->local->hw.wiphy);
217 
218 	if (!txq)
219 		return;
220 
221 	txqi = to_txq_info(txq);
222 
223 	if (enable)
224 		set_bit(IEEE80211_TXQ_AMPDU, &txqi->flags);
225 	else
226 		clear_bit(IEEE80211_TXQ_AMPDU, &txqi->flags);
227 
228 	clear_bit(IEEE80211_TXQ_STOP, &txqi->flags);
229 	local_bh_disable();
230 	rcu_read_lock();
231 	schedule_and_wake_txq(sta->sdata->local, txqi);
232 	rcu_read_unlock();
233 	local_bh_enable();
234 }
235 
236 /*
237  * splice packets from the STA's pending to the local pending,
238  * requires a call to ieee80211_agg_splice_finish later
239  */
240 static void __acquires(agg_queue)
241 ieee80211_agg_splice_packets(struct ieee80211_sub_if_data *sdata,
242 			     struct tid_ampdu_tx *tid_tx, u16 tid)
243 {
244 	struct ieee80211_local *local = sdata->local;
245 	int queue = sdata->vif.hw_queue[ieee80211_ac_from_tid(tid)];
246 	unsigned long flags;
247 
248 	ieee80211_stop_queue_agg(sdata, tid);
249 
250 	if (WARN(!tid_tx,
251 		 "TID %d gone but expected when splicing aggregates from the pending queue\n",
252 		 tid))
253 		return;
254 
255 	if (!skb_queue_empty(&tid_tx->pending)) {
256 		spin_lock_irqsave(&local->queue_stop_reason_lock, flags);
257 		/* copy over remaining packets */
258 		skb_queue_splice_tail_init(&tid_tx->pending,
259 					   &local->pending[queue]);
260 		spin_unlock_irqrestore(&local->queue_stop_reason_lock, flags);
261 	}
262 }
263 
264 static void __releases(agg_queue)
265 ieee80211_agg_splice_finish(struct ieee80211_sub_if_data *sdata, u16 tid)
266 {
267 	ieee80211_wake_queue_agg(sdata, tid);
268 }
269 
270 static void ieee80211_remove_tid_tx(struct sta_info *sta, int tid)
271 {
272 	struct tid_ampdu_tx *tid_tx;
273 
274 	lockdep_assert_wiphy(sta->local->hw.wiphy);
275 	lockdep_assert_held(&sta->lock);
276 
277 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
278 
279 	/*
280 	 * When we get here, the TX path will not be lockless any more wrt.
281 	 * aggregation, since the OPERATIONAL bit has long been cleared.
282 	 * Thus it will block on getting the lock, if it occurs. So if we
283 	 * stop the queue now, we will not get any more packets, and any
284 	 * that might be being processed will wait for us here, thereby
285 	 * guaranteeing that no packets go to the tid_tx pending queue any
286 	 * more.
287 	 */
288 
289 	ieee80211_agg_splice_packets(sta->sdata, tid_tx, tid);
290 
291 	/* future packets must not find the tid_tx struct any more */
292 	ieee80211_assign_tid_tx(sta, tid, NULL);
293 
294 	ieee80211_agg_splice_finish(sta->sdata, tid);
295 
296 	kfree_rcu(tid_tx, rcu_head);
297 }
298 
299 int __ieee80211_stop_tx_ba_session(struct sta_info *sta, u16 tid,
300 				   enum ieee80211_agg_stop_reason reason)
301 {
302 	struct ieee80211_local *local = sta->local;
303 	struct tid_ampdu_tx *tid_tx;
304 	struct ieee80211_ampdu_params params = {
305 		.sta = &sta->sta,
306 		.tid = tid,
307 		.buf_size = 0,
308 		.amsdu = false,
309 		.timeout = 0,
310 		.ssn = 0,
311 	};
312 	int ret;
313 
314 	lockdep_assert_wiphy(sta->local->hw.wiphy);
315 
316 	switch (reason) {
317 	case AGG_STOP_DECLINED:
318 	case AGG_STOP_LOCAL_REQUEST:
319 	case AGG_STOP_PEER_REQUEST:
320 		params.action = IEEE80211_AMPDU_TX_STOP_CONT;
321 		break;
322 	case AGG_STOP_DESTROY_STA:
323 		params.action = IEEE80211_AMPDU_TX_STOP_FLUSH;
324 		break;
325 	default:
326 		WARN_ON_ONCE(1);
327 		return -EINVAL;
328 	}
329 
330 	spin_lock_bh(&sta->lock);
331 
332 	/* free struct pending for start, if present */
333 	tid_tx = sta->ampdu_mlme.tid_start_tx[tid];
334 	kfree(tid_tx);
335 	sta->ampdu_mlme.tid_start_tx[tid] = NULL;
336 
337 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
338 	if (!tid_tx) {
339 		spin_unlock_bh(&sta->lock);
340 		return -ENOENT;
341 	}
342 
343 	/*
344 	 * if we're already stopping ignore any new requests to stop
345 	 * unless we're destroying it in which case notify the driver
346 	 */
347 	if (test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state)) {
348 		spin_unlock_bh(&sta->lock);
349 		if (reason != AGG_STOP_DESTROY_STA)
350 			return -EALREADY;
351 		params.action = IEEE80211_AMPDU_TX_STOP_FLUSH_CONT;
352 		ret = drv_ampdu_action(local, sta->sdata, &params);
353 		WARN_ON_ONCE(ret);
354 		return 0;
355 	}
356 
357 	if (test_bit(HT_AGG_STATE_WANT_START, &tid_tx->state)) {
358 		/* not even started yet! */
359 		ieee80211_assign_tid_tx(sta, tid, NULL);
360 		spin_unlock_bh(&sta->lock);
361 		kfree_rcu(tid_tx, rcu_head);
362 		return 0;
363 	}
364 
365 	set_bit(HT_AGG_STATE_STOPPING, &tid_tx->state);
366 
367 	ieee80211_agg_stop_txq(sta, tid);
368 
369 	spin_unlock_bh(&sta->lock);
370 
371 	ht_dbg(sta->sdata, "Tx BA session stop requested for %pM tid %u\n",
372 	       sta->sta.addr, tid);
373 
374 	del_timer_sync(&tid_tx->addba_resp_timer);
375 	del_timer_sync(&tid_tx->session_timer);
376 
377 	/*
378 	 * After this packets are no longer handed right through
379 	 * to the driver but are put onto tid_tx->pending instead,
380 	 * with locking to ensure proper access.
381 	 */
382 	clear_bit(HT_AGG_STATE_OPERATIONAL, &tid_tx->state);
383 
384 	/*
385 	 * There might be a few packets being processed right now (on
386 	 * another CPU) that have already gotten past the aggregation
387 	 * check when it was still OPERATIONAL and consequently have
388 	 * IEEE80211_TX_CTL_AMPDU set. In that case, this code might
389 	 * call into the driver at the same time or even before the
390 	 * TX paths calls into it, which could confuse the driver.
391 	 *
392 	 * Wait for all currently running TX paths to finish before
393 	 * telling the driver. New packets will not go through since
394 	 * the aggregation session is no longer OPERATIONAL.
395 	 */
396 	if (!local->in_reconfig)
397 		synchronize_net();
398 
399 	tid_tx->stop_initiator = reason == AGG_STOP_PEER_REQUEST ?
400 					WLAN_BACK_RECIPIENT :
401 					WLAN_BACK_INITIATOR;
402 	tid_tx->tx_stop = reason == AGG_STOP_LOCAL_REQUEST;
403 
404 	ret = drv_ampdu_action(local, sta->sdata, &params);
405 
406 	/* HW shall not deny going back to legacy */
407 	if (WARN_ON(ret)) {
408 		/*
409 		 * We may have pending packets get stuck in this case...
410 		 * Not bothering with a workaround for now.
411 		 */
412 	}
413 
414 	/*
415 	 * In the case of AGG_STOP_DESTROY_STA, the driver won't
416 	 * necessarily call ieee80211_stop_tx_ba_cb(), so this may
417 	 * seem like we can leave the tid_tx data pending forever.
418 	 * This is true, in a way, but "forever" is only until the
419 	 * station struct is actually destroyed. In the meantime,
420 	 * leaving it around ensures that we don't transmit packets
421 	 * to the driver on this TID which might confuse it.
422 	 */
423 
424 	return 0;
425 }
426 
427 /*
428  * After sending add Block Ack request we activated a timer until
429  * add Block Ack response will arrive from the recipient.
430  * If this timer expires sta_addba_resp_timer_expired will be executed.
431  */
432 static void sta_addba_resp_timer_expired(struct timer_list *t)
433 {
434 	struct tid_ampdu_tx *tid_tx = from_timer(tid_tx, t, addba_resp_timer);
435 	struct sta_info *sta = tid_tx->sta;
436 	u8 tid = tid_tx->tid;
437 
438 	/* check if the TID waits for addBA response */
439 	if (test_bit(HT_AGG_STATE_RESPONSE_RECEIVED, &tid_tx->state)) {
440 		ht_dbg(sta->sdata,
441 		       "timer expired on %pM tid %d not expecting addBA response\n",
442 		       sta->sta.addr, tid);
443 		return;
444 	}
445 
446 	ht_dbg(sta->sdata, "addBA response timer expired on %pM tid %d\n",
447 	       sta->sta.addr, tid);
448 
449 	ieee80211_stop_tx_ba_session(&sta->sta, tid);
450 }
451 
452 static void ieee80211_send_addba_with_timeout(struct sta_info *sta,
453 					      struct tid_ampdu_tx *tid_tx)
454 {
455 	struct ieee80211_sub_if_data *sdata = sta->sdata;
456 	struct ieee80211_local *local = sta->local;
457 	u8 tid = tid_tx->tid;
458 	u16 buf_size;
459 
460 	if (WARN_ON_ONCE(test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state) ||
461 			 test_bit(HT_AGG_STATE_WANT_STOP, &tid_tx->state)))
462 		return;
463 
464 	lockdep_assert_wiphy(sta->local->hw.wiphy);
465 
466 	/* activate the timer for the recipient's addBA response */
467 	mod_timer(&tid_tx->addba_resp_timer, jiffies + ADDBA_RESP_INTERVAL);
468 	ht_dbg(sdata, "activated addBA response timer on %pM tid %d\n",
469 	       sta->sta.addr, tid);
470 
471 	spin_lock_bh(&sta->lock);
472 	sta->ampdu_mlme.last_addba_req_time[tid] = jiffies;
473 	sta->ampdu_mlme.addba_req_num[tid]++;
474 	spin_unlock_bh(&sta->lock);
475 
476 	if (sta->sta.deflink.he_cap.has_he) {
477 		buf_size = local->hw.max_tx_aggregation_subframes;
478 	} else {
479 		/*
480 		 * We really should use what the driver told us it will
481 		 * transmit as the maximum, but certain APs (e.g. the
482 		 * LinkSys WRT120N with FW v1.0.07 build 002 Jun 18 2012)
483 		 * will crash when we use a lower number.
484 		 */
485 		buf_size = IEEE80211_MAX_AMPDU_BUF_HT;
486 	}
487 
488 	/* send AddBA request */
489 	ieee80211_send_addba_request(sdata, sta->sta.addr, tid,
490 				     tid_tx->dialog_token, tid_tx->ssn,
491 				     buf_size, tid_tx->timeout);
492 
493 	WARN_ON(test_and_set_bit(HT_AGG_STATE_SENT_ADDBA, &tid_tx->state));
494 }
495 
496 void ieee80211_tx_ba_session_handle_start(struct sta_info *sta, int tid)
497 {
498 	struct tid_ampdu_tx *tid_tx;
499 	struct ieee80211_local *local = sta->local;
500 	struct ieee80211_sub_if_data *sdata = sta->sdata;
501 	struct ieee80211_ampdu_params params = {
502 		.sta = &sta->sta,
503 		.action = IEEE80211_AMPDU_TX_START,
504 		.tid = tid,
505 		.buf_size = 0,
506 		.amsdu = false,
507 		.timeout = 0,
508 	};
509 	int ret;
510 
511 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
512 
513 	/*
514 	 * Start queuing up packets for this aggregation session.
515 	 * We're going to release them once the driver is OK with
516 	 * that.
517 	 */
518 	clear_bit(HT_AGG_STATE_WANT_START, &tid_tx->state);
519 
520 	/*
521 	 * Make sure no packets are being processed. This ensures that
522 	 * we have a valid starting sequence number and that in-flight
523 	 * packets have been flushed out and no packets for this TID
524 	 * will go into the driver during the ampdu_action call.
525 	 */
526 	synchronize_net();
527 
528 	params.ssn = sta->tid_seq[tid] >> 4;
529 	ret = drv_ampdu_action(local, sdata, &params);
530 	tid_tx->ssn = params.ssn;
531 	if (ret == IEEE80211_AMPDU_TX_START_DELAY_ADDBA) {
532 		return;
533 	} else if (ret == IEEE80211_AMPDU_TX_START_IMMEDIATE) {
534 		/*
535 		 * We didn't send the request yet, so don't need to check
536 		 * here if we already got a response, just mark as driver
537 		 * ready immediately.
538 		 */
539 		set_bit(HT_AGG_STATE_DRV_READY, &tid_tx->state);
540 	} else if (ret) {
541 		ht_dbg(sdata,
542 		       "BA request denied - HW unavailable for %pM tid %d\n",
543 		       sta->sta.addr, tid);
544 		spin_lock_bh(&sta->lock);
545 		ieee80211_agg_splice_packets(sdata, tid_tx, tid);
546 		ieee80211_assign_tid_tx(sta, tid, NULL);
547 		ieee80211_agg_splice_finish(sdata, tid);
548 		spin_unlock_bh(&sta->lock);
549 
550 		ieee80211_agg_start_txq(sta, tid, false);
551 
552 		kfree_rcu(tid_tx, rcu_head);
553 		return;
554 	}
555 
556 	ieee80211_send_addba_with_timeout(sta, tid_tx);
557 }
558 
559 void ieee80211_refresh_tx_agg_session_timer(struct ieee80211_sta *pubsta,
560 					    u16 tid)
561 {
562 	struct sta_info *sta = container_of(pubsta, struct sta_info, sta);
563 	struct tid_ampdu_tx *tid_tx;
564 
565 	if (WARN_ON_ONCE(tid >= IEEE80211_NUM_TIDS))
566 		return;
567 
568 	tid_tx = rcu_dereference(sta->ampdu_mlme.tid_tx[tid]);
569 	if (!tid_tx)
570 		return;
571 
572 	tid_tx->last_tx = jiffies;
573 }
574 EXPORT_SYMBOL(ieee80211_refresh_tx_agg_session_timer);
575 
576 /*
577  * After accepting the AddBA Response we activated a timer,
578  * resetting it after each frame that we send.
579  */
580 static void sta_tx_agg_session_timer_expired(struct timer_list *t)
581 {
582 	struct tid_ampdu_tx *tid_tx = from_timer(tid_tx, t, session_timer);
583 	struct sta_info *sta = tid_tx->sta;
584 	u8 tid = tid_tx->tid;
585 	unsigned long timeout;
586 
587 	if (test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state)) {
588 		return;
589 	}
590 
591 	timeout = tid_tx->last_tx + TU_TO_JIFFIES(tid_tx->timeout);
592 	if (time_is_after_jiffies(timeout)) {
593 		mod_timer(&tid_tx->session_timer, timeout);
594 		return;
595 	}
596 
597 	ht_dbg(sta->sdata, "tx session timer expired on %pM tid %d\n",
598 	       sta->sta.addr, tid);
599 
600 	ieee80211_stop_tx_ba_session(&sta->sta, tid);
601 }
602 
603 int ieee80211_start_tx_ba_session(struct ieee80211_sta *pubsta, u16 tid,
604 				  u16 timeout)
605 {
606 	struct sta_info *sta = container_of(pubsta, struct sta_info, sta);
607 	struct ieee80211_sub_if_data *sdata = sta->sdata;
608 	struct ieee80211_local *local = sdata->local;
609 	struct tid_ampdu_tx *tid_tx;
610 	int ret = 0;
611 
612 	trace_api_start_tx_ba_session(pubsta, tid);
613 
614 	if (WARN(sta->reserved_tid == tid,
615 		 "Requested to start BA session on reserved tid=%d", tid))
616 		return -EINVAL;
617 
618 	if (!pubsta->deflink.ht_cap.ht_supported &&
619 	    sta->sdata->vif.bss_conf.chanreq.oper.chan->band != NL80211_BAND_6GHZ)
620 		return -EINVAL;
621 
622 	if (WARN_ON_ONCE(!local->ops->ampdu_action))
623 		return -EINVAL;
624 
625 	if ((tid >= IEEE80211_NUM_TIDS) ||
626 	    !ieee80211_hw_check(&local->hw, AMPDU_AGGREGATION) ||
627 	    ieee80211_hw_check(&local->hw, TX_AMPDU_SETUP_IN_HW))
628 		return -EINVAL;
629 
630 	if (WARN_ON(tid >= IEEE80211_FIRST_TSPEC_TSID))
631 		return -EINVAL;
632 
633 	ht_dbg(sdata, "Open BA session requested for %pM tid %u\n",
634 	       pubsta->addr, tid);
635 
636 	if (sdata->vif.type != NL80211_IFTYPE_STATION &&
637 	    sdata->vif.type != NL80211_IFTYPE_MESH_POINT &&
638 	    sdata->vif.type != NL80211_IFTYPE_AP_VLAN &&
639 	    sdata->vif.type != NL80211_IFTYPE_AP &&
640 	    sdata->vif.type != NL80211_IFTYPE_ADHOC)
641 		return -EINVAL;
642 
643 	if (test_sta_flag(sta, WLAN_STA_BLOCK_BA)) {
644 		ht_dbg(sdata,
645 		       "BA sessions blocked - Denying BA session request %pM tid %d\n",
646 		       sta->sta.addr, tid);
647 		return -EINVAL;
648 	}
649 
650 	if (test_sta_flag(sta, WLAN_STA_MFP) &&
651 	    !test_sta_flag(sta, WLAN_STA_AUTHORIZED)) {
652 		ht_dbg(sdata,
653 		       "MFP STA not authorized - deny BA session request %pM tid %d\n",
654 		       sta->sta.addr, tid);
655 		return -EINVAL;
656 	}
657 
658 	/*
659 	 * 802.11n-2009 11.5.1.1: If the initiating STA is an HT STA, is a
660 	 * member of an IBSS, and has no other existing Block Ack agreement
661 	 * with the recipient STA, then the initiating STA shall transmit a
662 	 * Probe Request frame to the recipient STA and shall not transmit an
663 	 * ADDBA Request frame unless it receives a Probe Response frame
664 	 * from the recipient within dot11ADDBAFailureTimeout.
665 	 *
666 	 * The probe request mechanism for ADDBA is currently not implemented,
667 	 * but we only build up Block Ack session with HT STAs. This information
668 	 * is set when we receive a bss info from a probe response or a beacon.
669 	 */
670 	if (sta->sdata->vif.type == NL80211_IFTYPE_ADHOC &&
671 	    !sta->sta.deflink.ht_cap.ht_supported) {
672 		ht_dbg(sdata,
673 		       "BA request denied - IBSS STA %pM does not advertise HT support\n",
674 		       pubsta->addr);
675 		return -EINVAL;
676 	}
677 
678 	spin_lock_bh(&sta->lock);
679 
680 	/* we have tried too many times, receiver does not want A-MPDU */
681 	if (sta->ampdu_mlme.addba_req_num[tid] > HT_AGG_MAX_RETRIES) {
682 		ret = -EBUSY;
683 		goto err_unlock_sta;
684 	}
685 
686 	/*
687 	 * if we have tried more than HT_AGG_BURST_RETRIES times we
688 	 * will spread our requests in time to avoid stalling connection
689 	 * for too long
690 	 */
691 	if (sta->ampdu_mlme.addba_req_num[tid] > HT_AGG_BURST_RETRIES &&
692 	    time_before(jiffies, sta->ampdu_mlme.last_addba_req_time[tid] +
693 			HT_AGG_RETRIES_PERIOD)) {
694 		ht_dbg(sdata,
695 		       "BA request denied - %d failed requests on %pM tid %u\n",
696 		       sta->ampdu_mlme.addba_req_num[tid], sta->sta.addr, tid);
697 		ret = -EBUSY;
698 		goto err_unlock_sta;
699 	}
700 
701 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
702 	/* check if the TID is not in aggregation flow already */
703 	if (tid_tx || sta->ampdu_mlme.tid_start_tx[tid]) {
704 		ht_dbg(sdata,
705 		       "BA request denied - session is not idle on %pM tid %u\n",
706 		       sta->sta.addr, tid);
707 		ret = -EAGAIN;
708 		goto err_unlock_sta;
709 	}
710 
711 	/* prepare A-MPDU MLME for Tx aggregation */
712 	tid_tx = kzalloc(sizeof(struct tid_ampdu_tx), GFP_ATOMIC);
713 	if (!tid_tx) {
714 		ret = -ENOMEM;
715 		goto err_unlock_sta;
716 	}
717 
718 	skb_queue_head_init(&tid_tx->pending);
719 	__set_bit(HT_AGG_STATE_WANT_START, &tid_tx->state);
720 
721 	tid_tx->timeout = timeout;
722 	tid_tx->sta = sta;
723 	tid_tx->tid = tid;
724 
725 	/* response timer */
726 	timer_setup(&tid_tx->addba_resp_timer, sta_addba_resp_timer_expired, 0);
727 
728 	/* tx timer */
729 	timer_setup(&tid_tx->session_timer,
730 		    sta_tx_agg_session_timer_expired, TIMER_DEFERRABLE);
731 
732 	/* assign a dialog token */
733 	sta->ampdu_mlme.dialog_token_allocator++;
734 	tid_tx->dialog_token = sta->ampdu_mlme.dialog_token_allocator;
735 
736 	/*
737 	 * Finally, assign it to the start array; the work item will
738 	 * collect it and move it to the normal array.
739 	 */
740 	sta->ampdu_mlme.tid_start_tx[tid] = tid_tx;
741 
742 	wiphy_work_queue(local->hw.wiphy, &sta->ampdu_mlme.work);
743 
744 	/* this flow continues off the work */
745  err_unlock_sta:
746 	spin_unlock_bh(&sta->lock);
747 	return ret;
748 }
749 EXPORT_SYMBOL(ieee80211_start_tx_ba_session);
750 
751 static void ieee80211_agg_tx_operational(struct ieee80211_local *local,
752 					 struct sta_info *sta, u16 tid)
753 {
754 	struct tid_ampdu_tx *tid_tx;
755 	struct ieee80211_ampdu_params params = {
756 		.sta = &sta->sta,
757 		.action = IEEE80211_AMPDU_TX_OPERATIONAL,
758 		.tid = tid,
759 		.timeout = 0,
760 		.ssn = 0,
761 	};
762 
763 	lockdep_assert_wiphy(sta->local->hw.wiphy);
764 
765 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
766 	params.buf_size = tid_tx->buf_size;
767 	params.amsdu = tid_tx->amsdu;
768 
769 	ht_dbg(sta->sdata, "Aggregation is on for %pM tid %d\n",
770 	       sta->sta.addr, tid);
771 
772 	drv_ampdu_action(local, sta->sdata, &params);
773 
774 	/*
775 	 * synchronize with TX path, while splicing the TX path
776 	 * should block so it won't put more packets onto pending.
777 	 */
778 	spin_lock_bh(&sta->lock);
779 
780 	ieee80211_agg_splice_packets(sta->sdata, tid_tx, tid);
781 	/*
782 	 * Now mark as operational. This will be visible
783 	 * in the TX path, and lets it go lock-free in
784 	 * the common case.
785 	 */
786 	set_bit(HT_AGG_STATE_OPERATIONAL, &tid_tx->state);
787 	ieee80211_agg_splice_finish(sta->sdata, tid);
788 
789 	spin_unlock_bh(&sta->lock);
790 
791 	ieee80211_agg_start_txq(sta, tid, true);
792 }
793 
794 void ieee80211_start_tx_ba_cb(struct sta_info *sta, int tid,
795 			      struct tid_ampdu_tx *tid_tx)
796 {
797 	struct ieee80211_sub_if_data *sdata = sta->sdata;
798 	struct ieee80211_local *local = sdata->local;
799 
800 	lockdep_assert_wiphy(sta->local->hw.wiphy);
801 
802 	if (WARN_ON(test_and_set_bit(HT_AGG_STATE_DRV_READY, &tid_tx->state)))
803 		return;
804 
805 	if (test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state) ||
806 	    test_bit(HT_AGG_STATE_WANT_STOP, &tid_tx->state))
807 		return;
808 
809 	if (!test_bit(HT_AGG_STATE_SENT_ADDBA, &tid_tx->state)) {
810 		ieee80211_send_addba_with_timeout(sta, tid_tx);
811 		/* RESPONSE_RECEIVED state whould trigger the flow again */
812 		return;
813 	}
814 
815 	if (test_bit(HT_AGG_STATE_RESPONSE_RECEIVED, &tid_tx->state))
816 		ieee80211_agg_tx_operational(local, sta, tid);
817 }
818 
819 static struct tid_ampdu_tx *
820 ieee80211_lookup_tid_tx(struct ieee80211_sub_if_data *sdata,
821 			const u8 *ra, u16 tid, struct sta_info **sta)
822 {
823 	struct tid_ampdu_tx *tid_tx;
824 
825 	if (tid >= IEEE80211_NUM_TIDS) {
826 		ht_dbg(sdata, "Bad TID value: tid = %d (>= %d)\n",
827 		       tid, IEEE80211_NUM_TIDS);
828 		return NULL;
829 	}
830 
831 	*sta = sta_info_get_bss(sdata, ra);
832 	if (!*sta) {
833 		ht_dbg(sdata, "Could not find station: %pM\n", ra);
834 		return NULL;
835 	}
836 
837 	tid_tx = rcu_dereference((*sta)->ampdu_mlme.tid_tx[tid]);
838 
839 	if (WARN_ON(!tid_tx))
840 		ht_dbg(sdata, "addBA was not requested!\n");
841 
842 	return tid_tx;
843 }
844 
845 void ieee80211_start_tx_ba_cb_irqsafe(struct ieee80211_vif *vif,
846 				      const u8 *ra, u16 tid)
847 {
848 	struct ieee80211_sub_if_data *sdata = vif_to_sdata(vif);
849 	struct ieee80211_local *local = sdata->local;
850 	struct sta_info *sta;
851 	struct tid_ampdu_tx *tid_tx;
852 
853 	trace_api_start_tx_ba_cb(sdata, ra, tid);
854 
855 	rcu_read_lock();
856 	tid_tx = ieee80211_lookup_tid_tx(sdata, ra, tid, &sta);
857 	if (!tid_tx)
858 		goto out;
859 
860 	set_bit(HT_AGG_STATE_START_CB, &tid_tx->state);
861 	wiphy_work_queue(local->hw.wiphy, &sta->ampdu_mlme.work);
862  out:
863 	rcu_read_unlock();
864 }
865 EXPORT_SYMBOL(ieee80211_start_tx_ba_cb_irqsafe);
866 
867 int ieee80211_stop_tx_ba_session(struct ieee80211_sta *pubsta, u16 tid)
868 {
869 	struct sta_info *sta = container_of(pubsta, struct sta_info, sta);
870 	struct ieee80211_sub_if_data *sdata = sta->sdata;
871 	struct ieee80211_local *local = sdata->local;
872 	struct tid_ampdu_tx *tid_tx;
873 	int ret = 0;
874 
875 	trace_api_stop_tx_ba_session(pubsta, tid);
876 
877 	if (!local->ops->ampdu_action)
878 		return -EINVAL;
879 
880 	if (tid >= IEEE80211_NUM_TIDS)
881 		return -EINVAL;
882 
883 	spin_lock_bh(&sta->lock);
884 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
885 
886 	if (!tid_tx) {
887 		ret = -ENOENT;
888 		goto unlock;
889 	}
890 
891 	WARN(sta->reserved_tid == tid,
892 	     "Requested to stop BA session on reserved tid=%d", tid);
893 
894 	if (test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state)) {
895 		/* already in progress stopping it */
896 		ret = 0;
897 		goto unlock;
898 	}
899 
900 	set_bit(HT_AGG_STATE_WANT_STOP, &tid_tx->state);
901 	wiphy_work_queue(local->hw.wiphy, &sta->ampdu_mlme.work);
902 
903  unlock:
904 	spin_unlock_bh(&sta->lock);
905 	return ret;
906 }
907 EXPORT_SYMBOL(ieee80211_stop_tx_ba_session);
908 
909 void ieee80211_stop_tx_ba_cb(struct sta_info *sta, int tid,
910 			     struct tid_ampdu_tx *tid_tx)
911 {
912 	struct ieee80211_sub_if_data *sdata = sta->sdata;
913 	bool send_delba = false;
914 	bool start_txq = false;
915 
916 	ht_dbg(sdata, "Stopping Tx BA session for %pM tid %d\n",
917 	       sta->sta.addr, tid);
918 
919 	spin_lock_bh(&sta->lock);
920 
921 	if (!test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state)) {
922 		ht_dbg(sdata,
923 		       "unexpected callback to A-MPDU stop for %pM tid %d\n",
924 		       sta->sta.addr, tid);
925 		goto unlock_sta;
926 	}
927 
928 	if (tid_tx->stop_initiator == WLAN_BACK_INITIATOR && tid_tx->tx_stop)
929 		send_delba = true;
930 
931 	ieee80211_remove_tid_tx(sta, tid);
932 	start_txq = true;
933 
934  unlock_sta:
935 	spin_unlock_bh(&sta->lock);
936 
937 	if (start_txq)
938 		ieee80211_agg_start_txq(sta, tid, false);
939 
940 	if (send_delba)
941 		ieee80211_send_delba(sdata, sta->sta.addr, tid,
942 			WLAN_BACK_INITIATOR, WLAN_REASON_QSTA_NOT_USE);
943 }
944 
945 void ieee80211_stop_tx_ba_cb_irqsafe(struct ieee80211_vif *vif,
946 				     const u8 *ra, u16 tid)
947 {
948 	struct ieee80211_sub_if_data *sdata = vif_to_sdata(vif);
949 	struct ieee80211_local *local = sdata->local;
950 	struct sta_info *sta;
951 	struct tid_ampdu_tx *tid_tx;
952 
953 	trace_api_stop_tx_ba_cb(sdata, ra, tid);
954 
955 	rcu_read_lock();
956 	tid_tx = ieee80211_lookup_tid_tx(sdata, ra, tid, &sta);
957 	if (!tid_tx)
958 		goto out;
959 
960 	set_bit(HT_AGG_STATE_STOP_CB, &tid_tx->state);
961 	wiphy_work_queue(local->hw.wiphy, &sta->ampdu_mlme.work);
962  out:
963 	rcu_read_unlock();
964 }
965 EXPORT_SYMBOL(ieee80211_stop_tx_ba_cb_irqsafe);
966 
967 
968 void ieee80211_process_addba_resp(struct ieee80211_local *local,
969 				  struct sta_info *sta,
970 				  struct ieee80211_mgmt *mgmt,
971 				  size_t len)
972 {
973 	struct tid_ampdu_tx *tid_tx;
974 	struct ieee80211_txq *txq;
975 	u16 capab, tid, buf_size;
976 	bool amsdu;
977 
978 	lockdep_assert_wiphy(sta->local->hw.wiphy);
979 
980 	capab = le16_to_cpu(mgmt->u.action.u.addba_resp.capab);
981 	amsdu = capab & IEEE80211_ADDBA_PARAM_AMSDU_MASK;
982 	tid = u16_get_bits(capab, IEEE80211_ADDBA_PARAM_TID_MASK);
983 	buf_size = u16_get_bits(capab, IEEE80211_ADDBA_PARAM_BUF_SIZE_MASK);
984 	buf_size = min(buf_size, local->hw.max_tx_aggregation_subframes);
985 
986 	txq = sta->sta.txq[tid];
987 	if (!amsdu && txq)
988 		set_bit(IEEE80211_TXQ_NO_AMSDU, &to_txq_info(txq)->flags);
989 
990 	tid_tx = rcu_dereference_protected_tid_tx(sta, tid);
991 	if (!tid_tx)
992 		return;
993 
994 	if (mgmt->u.action.u.addba_resp.dialog_token != tid_tx->dialog_token) {
995 		ht_dbg(sta->sdata, "wrong addBA response token, %pM tid %d\n",
996 		       sta->sta.addr, tid);
997 		return;
998 	}
999 
1000 	del_timer_sync(&tid_tx->addba_resp_timer);
1001 
1002 	ht_dbg(sta->sdata, "switched off addBA timer for %pM tid %d\n",
1003 	       sta->sta.addr, tid);
1004 
1005 	/*
1006 	 * addba_resp_timer may have fired before we got here, and
1007 	 * caused WANT_STOP to be set. If the stop then was already
1008 	 * processed further, STOPPING might be set.
1009 	 */
1010 	if (test_bit(HT_AGG_STATE_WANT_STOP, &tid_tx->state) ||
1011 	    test_bit(HT_AGG_STATE_STOPPING, &tid_tx->state)) {
1012 		ht_dbg(sta->sdata,
1013 		       "got addBA resp for %pM tid %d but we already gave up\n",
1014 		       sta->sta.addr, tid);
1015 		return;
1016 	}
1017 
1018 	/*
1019 	 * IEEE 802.11-2007 7.3.1.14:
1020 	 * In an ADDBA Response frame, when the Status Code field
1021 	 * is set to 0, the Buffer Size subfield is set to a value
1022 	 * of at least 1.
1023 	 */
1024 	if (le16_to_cpu(mgmt->u.action.u.addba_resp.status)
1025 			== WLAN_STATUS_SUCCESS && buf_size) {
1026 		if (test_and_set_bit(HT_AGG_STATE_RESPONSE_RECEIVED,
1027 				     &tid_tx->state)) {
1028 			/* ignore duplicate response */
1029 			return;
1030 		}
1031 
1032 		tid_tx->buf_size = buf_size;
1033 		tid_tx->amsdu = amsdu;
1034 
1035 		if (test_bit(HT_AGG_STATE_DRV_READY, &tid_tx->state))
1036 			ieee80211_agg_tx_operational(local, sta, tid);
1037 
1038 		sta->ampdu_mlme.addba_req_num[tid] = 0;
1039 
1040 		tid_tx->timeout =
1041 			le16_to_cpu(mgmt->u.action.u.addba_resp.timeout);
1042 
1043 		if (tid_tx->timeout) {
1044 			mod_timer(&tid_tx->session_timer,
1045 				  TU_TO_EXP_TIME(tid_tx->timeout));
1046 			tid_tx->last_tx = jiffies;
1047 		}
1048 
1049 	} else {
1050 		__ieee80211_stop_tx_ba_session(sta, tid, AGG_STOP_DECLINED);
1051 	}
1052 }
1053