xref: /linux/drivers/thermal/intel/Kconfig (revision 6e7fd890f1d6ac83805409e9c346240de2705584)
1# SPDX-License-Identifier: GPL-2.0-only
2config INTEL_POWERCLAMP
3	tristate "Intel PowerClamp idle injection driver"
4	depends on X86
5	depends on CPU_SUP_INTEL
6	depends on CPU_IDLE
7	select POWERCAP
8	select IDLE_INJECT
9	help
10	  Enable this to enable Intel PowerClamp idle injection driver. This
11	  enforce idle time which results in more package C-state residency. The
12	  user interface is exposed via generic thermal framework.
13
14config X86_THERMAL_VECTOR
15	def_bool y
16	depends on X86 && CPU_SUP_INTEL && X86_LOCAL_APIC
17
18config INTEL_TCC
19	bool
20	depends on X86
21
22config X86_PKG_TEMP_THERMAL
23	tristate "X86 package temperature thermal driver"
24	depends on X86_THERMAL_VECTOR
25	select THERMAL_GOV_USER_SPACE
26	select INTEL_TCC
27	default m
28	help
29	  Enable this to register CPU digital sensor for package temperature as
30	  thermal zone. Each package will have its own thermal zone. There are
31	  two trip points which can be set by user to get notifications via thermal
32	  notification methods.
33
34config INTEL_SOC_DTS_IOSF_CORE
35	tristate
36	depends on X86 && PCI
37	select IOSF_MBI
38	select INTEL_TCC
39	help
40	  This is becoming a common feature for Intel SoCs to expose the additional
41	  digital temperature sensors (DTSs) using side band interface (IOSF). This
42	  implements the common set of helper functions to register, get temperature
43	  and get/set thresholds on DTSs.
44
45config INTEL_SOC_DTS_THERMAL
46	tristate "Intel SoCs DTS thermal driver"
47	depends on X86 && PCI && ACPI
48	select INTEL_SOC_DTS_IOSF_CORE
49	help
50	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
51	  temperature sensor (DTS). These SoCs have two additional DTSs in
52	  addition to DTSs on CPU cores. Each DTS will be registered as a
53	  thermal zone. There are two trip points. One of the trip point can
54	  be set by user mode programs to get notifications via Linux thermal
55	  notification methods.The other trip is a critical trip point, which
56	  was set by the driver based on the TJ MAX temperature.
57
58config INTEL_QUARK_DTS_THERMAL
59	tristate "Intel Quark DTS thermal driver"
60	depends on X86_INTEL_QUARK
61	help
62	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
63	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
64	  The DTS will be registered as a thermal zone. There are two trip points:
65	  hot & critical. The critical trip point default value is set by
66	  underlying BIOS/Firmware.
67
68menu "ACPI INT340X thermal drivers"
69source "drivers/thermal/intel/int340x_thermal/Kconfig"
70endmenu
71
72config INTEL_BXT_PMIC_THERMAL
73	tristate "Intel Broxton PMIC thermal driver"
74	depends on X86 && INTEL_SOC_PMIC_BXTWC
75	select REGMAP
76	help
77	  Select this driver for Intel Broxton PMIC with ADC channels monitoring
78	  system temperature measurements and alerts.
79	  This driver is used for monitoring the ADC channels of PMIC and handles
80	  the alert trip point interrupts and notifies the thermal framework with
81	  the trip point and temperature details of the zone.
82
83config INTEL_PCH_THERMAL
84	tristate "Intel PCH Thermal Reporting Driver"
85	depends on X86 && PCI
86	select ACPI_THERMAL_LIB if ACPI
87	help
88	  Enable this to support thermal reporting on certain intel PCHs.
89	  Thermal reporting device will provide temperature reading,
90	  programmable trip points and other information.
91
92config INTEL_TCC_COOLING
93	tristate "Intel TCC offset cooling Driver"
94	depends on X86
95	select INTEL_TCC
96	help
97	  Enable this to support system cooling by adjusting the effective TCC
98	  activation temperature via the TCC Offset register, which is widely
99	  supported on modern Intel platforms.
100	  Note that, on different platforms, the behavior might be different
101	  on how fast the setting takes effect, and how much the CPU frequency
102	  is reduced.
103
104config INTEL_HFI_THERMAL
105	bool "Intel Hardware Feedback Interface"
106	depends on NET
107	depends on CPU_SUP_INTEL
108	depends on X86_THERMAL_VECTOR
109	select THERMAL_NETLINK
110	help
111	  Select this option to enable the Hardware Feedback Interface. If
112	  selected, hardware provides guidance to the operating system on
113	  the performance and energy efficiency capabilities of each CPU.
114	  These capabilities may change as a result of changes in the operating
115	  conditions of the system such power and thermal limits. If selected,
116	  the kernel relays updates in CPUs' capabilities to userspace.
117