1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * A power allocator to manage temperature
4  *
5  * Copyright (C) 2014 ARM Ltd.
6  *
7  */
8 
9 #define pr_fmt(fmt) "Power allocator: " fmt
10 
11 #include <linux/rculist.h>
12 #include <linux/slab.h>
13 #include <linux/thermal.h>
14 
15 #define CREATE_TRACE_POINTS
16 #include <trace/events/thermal_power_allocator.h>
17 
18 #include "thermal_core.h"
19 
20 #define INVALID_TRIP -1
21 
22 #define FRAC_BITS 10
23 #define int_to_frac(x) ((x) << FRAC_BITS)
24 #define frac_to_int(x) ((x) >> FRAC_BITS)
25 
26 /**
27  * mul_frac() - multiply two fixed-point numbers
28  * @x:	first multiplicand
29  * @y:	second multiplicand
30  *
31  * Return: the result of multiplying two fixed-point numbers.  The
32  * result is also a fixed-point number.
33  */
34 static inline s64 mul_frac(s64 x, s64 y)
35 {
36 	return (x * y) >> FRAC_BITS;
37 }
38 
39 /**
40  * div_frac() - divide two fixed-point numbers
41  * @x:	the dividend
42  * @y:	the divisor
43  *
44  * Return: the result of dividing two fixed-point numbers.  The
45  * result is also a fixed-point number.
46  */
47 static inline s64 div_frac(s64 x, s64 y)
48 {
49 	return div_s64(x << FRAC_BITS, y);
50 }
51 
52 /**
53  * struct power_allocator_params - parameters for the power allocator governor
54  * @allocated_tzp:	whether we have allocated tzp for this thermal zone and
55  *			it needs to be freed on unbind
56  * @err_integral:	accumulated error in the PID controller.
57  * @prev_err:	error in the previous iteration of the PID controller.
58  *		Used to calculate the derivative term.
59  * @trip_switch_on:	first passive trip point of the thermal zone.  The
60  *			governor switches on when this trip point is crossed.
61  *			If the thermal zone only has one passive trip point,
62  *			@trip_switch_on should be INVALID_TRIP.
63  * @trip_max_desired_temperature:	last passive trip point of the thermal
64  *					zone.  The temperature we are
65  *					controlling for.
66  * @sustainable_power:	Sustainable power (heat) that this thermal zone can
67  *			dissipate
68  */
69 struct power_allocator_params {
70 	bool allocated_tzp;
71 	s64 err_integral;
72 	s32 prev_err;
73 	int trip_switch_on;
74 	int trip_max_desired_temperature;
75 	u32 sustainable_power;
76 };
77 
78 /**
79  * estimate_sustainable_power() - Estimate the sustainable power of a thermal zone
80  * @tz: thermal zone we are operating in
81  *
82  * For thermal zones that don't provide a sustainable_power in their
83  * thermal_zone_params, estimate one.  Calculate it using the minimum
84  * power of all the cooling devices as that gives a valid value that
85  * can give some degree of functionality.  For optimal performance of
86  * this governor, provide a sustainable_power in the thermal zone's
87  * thermal_zone_params.
88  */
89 static u32 estimate_sustainable_power(struct thermal_zone_device *tz)
90 {
91 	u32 sustainable_power = 0;
92 	struct thermal_instance *instance;
93 	struct power_allocator_params *params = tz->governor_data;
94 
95 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
96 		struct thermal_cooling_device *cdev = instance->cdev;
97 		u32 min_power;
98 
99 		if (instance->trip != params->trip_max_desired_temperature)
100 			continue;
101 
102 		if (!cdev_is_power_actor(cdev))
103 			continue;
104 
105 		if (cdev->ops->state2power(cdev, instance->upper, &min_power))
106 			continue;
107 
108 		sustainable_power += min_power;
109 	}
110 
111 	return sustainable_power;
112 }
113 
114 /**
115  * estimate_pid_constants() - Estimate the constants for the PID controller
116  * @tz:		thermal zone for which to estimate the constants
117  * @sustainable_power:	sustainable power for the thermal zone
118  * @trip_switch_on:	trip point number for the switch on temperature
119  * @control_temp:	target temperature for the power allocator governor
120  *
121  * This function is used to update the estimation of the PID
122  * controller constants in struct thermal_zone_parameters.
123  */
124 static void estimate_pid_constants(struct thermal_zone_device *tz,
125 				   u32 sustainable_power, int trip_switch_on,
126 				   int control_temp)
127 {
128 	int ret;
129 	int switch_on_temp;
130 	u32 temperature_threshold;
131 	s32 k_i;
132 
133 	ret = tz->ops->get_trip_temp(tz, trip_switch_on, &switch_on_temp);
134 	if (ret)
135 		switch_on_temp = 0;
136 
137 	temperature_threshold = control_temp - switch_on_temp;
138 	/*
139 	 * estimate_pid_constants() tries to find appropriate default
140 	 * values for thermal zones that don't provide them. If a
141 	 * system integrator has configured a thermal zone with two
142 	 * passive trip points at the same temperature, that person
143 	 * hasn't put any effort to set up the thermal zone properly
144 	 * so just give up.
145 	 */
146 	if (!temperature_threshold)
147 		return;
148 
149 	tz->tzp->k_po = int_to_frac(sustainable_power) /
150 		temperature_threshold;
151 
152 	tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
153 		temperature_threshold;
154 
155 	k_i = tz->tzp->k_pu / 10;
156 	tz->tzp->k_i = k_i > 0 ? k_i : 1;
157 
158 	/*
159 	 * The default for k_d and integral_cutoff is 0, so we can
160 	 * leave them as they are.
161 	 */
162 }
163 
164 /**
165  * get_sustainable_power() - Get the right sustainable power
166  * @tz:		thermal zone for which to estimate the constants
167  * @params:	parameters for the power allocator governor
168  * @control_temp:	target temperature for the power allocator governor
169  *
170  * This function is used for getting the proper sustainable power value based
171  * on variables which might be updated by the user sysfs interface. If that
172  * happen the new value is going to be estimated and updated. It is also used
173  * after thermal zone binding, where the initial values where set to 0.
174  */
175 static u32 get_sustainable_power(struct thermal_zone_device *tz,
176 				 struct power_allocator_params *params,
177 				 int control_temp)
178 {
179 	u32 sustainable_power;
180 
181 	if (!tz->tzp->sustainable_power)
182 		sustainable_power = estimate_sustainable_power(tz);
183 	else
184 		sustainable_power = tz->tzp->sustainable_power;
185 
186 	/* Check if it's init value 0 or there was update via sysfs */
187 	if (sustainable_power != params->sustainable_power) {
188 		estimate_pid_constants(tz, sustainable_power,
189 				       params->trip_switch_on, control_temp);
190 
191 		/* Do the estimation only once and make available in sysfs */
192 		tz->tzp->sustainable_power = sustainable_power;
193 		params->sustainable_power = sustainable_power;
194 	}
195 
196 	return sustainable_power;
197 }
198 
199 /**
200  * pid_controller() - PID controller
201  * @tz:	thermal zone we are operating in
202  * @control_temp:	the target temperature in millicelsius
203  * @max_allocatable_power:	maximum allocatable power for this thermal zone
204  *
205  * This PID controller increases the available power budget so that the
206  * temperature of the thermal zone gets as close as possible to
207  * @control_temp and limits the power if it exceeds it.  k_po is the
208  * proportional term when we are overshooting, k_pu is the
209  * proportional term when we are undershooting.  integral_cutoff is a
210  * threshold below which we stop accumulating the error.  The
211  * accumulated error is only valid if the requested power will make
212  * the system warmer.  If the system is mostly idle, there's no point
213  * in accumulating positive error.
214  *
215  * Return: The power budget for the next period.
216  */
217 static u32 pid_controller(struct thermal_zone_device *tz,
218 			  int control_temp,
219 			  u32 max_allocatable_power)
220 {
221 	s64 p, i, d, power_range;
222 	s32 err, max_power_frac;
223 	u32 sustainable_power;
224 	struct power_allocator_params *params = tz->governor_data;
225 
226 	max_power_frac = int_to_frac(max_allocatable_power);
227 
228 	sustainable_power = get_sustainable_power(tz, params, control_temp);
229 
230 	err = control_temp - tz->temperature;
231 	err = int_to_frac(err);
232 
233 	/* Calculate the proportional term */
234 	p = mul_frac(err < 0 ? tz->tzp->k_po : tz->tzp->k_pu, err);
235 
236 	/*
237 	 * Calculate the integral term
238 	 *
239 	 * if the error is less than cut off allow integration (but
240 	 * the integral is limited to max power)
241 	 */
242 	i = mul_frac(tz->tzp->k_i, params->err_integral);
243 
244 	if (err < int_to_frac(tz->tzp->integral_cutoff)) {
245 		s64 i_next = i + mul_frac(tz->tzp->k_i, err);
246 
247 		if (abs(i_next) < max_power_frac) {
248 			i = i_next;
249 			params->err_integral += err;
250 		}
251 	}
252 
253 	/*
254 	 * Calculate the derivative term
255 	 *
256 	 * We do err - prev_err, so with a positive k_d, a decreasing
257 	 * error (i.e. driving closer to the line) results in less
258 	 * power being applied, slowing down the controller)
259 	 */
260 	d = mul_frac(tz->tzp->k_d, err - params->prev_err);
261 	d = div_frac(d, jiffies_to_msecs(tz->passive_delay_jiffies));
262 	params->prev_err = err;
263 
264 	power_range = p + i + d;
265 
266 	/* feed-forward the known sustainable dissipatable power */
267 	power_range = sustainable_power + frac_to_int(power_range);
268 
269 	power_range = clamp(power_range, (s64)0, (s64)max_allocatable_power);
270 
271 	trace_thermal_power_allocator_pid(tz, frac_to_int(err),
272 					  frac_to_int(params->err_integral),
273 					  frac_to_int(p), frac_to_int(i),
274 					  frac_to_int(d), power_range);
275 
276 	return power_range;
277 }
278 
279 /**
280  * power_actor_set_power() - limit the maximum power a cooling device consumes
281  * @cdev:	pointer to &thermal_cooling_device
282  * @instance:	thermal instance to update
283  * @power:	the power in milliwatts
284  *
285  * Set the cooling device to consume at most @power milliwatts. The limit is
286  * expected to be a cap at the maximum power consumption.
287  *
288  * Return: 0 on success, -EINVAL if the cooling device does not
289  * implement the power actor API or -E* for other failures.
290  */
291 static int
292 power_actor_set_power(struct thermal_cooling_device *cdev,
293 		      struct thermal_instance *instance, u32 power)
294 {
295 	unsigned long state;
296 	int ret;
297 
298 	ret = cdev->ops->power2state(cdev, power, &state);
299 	if (ret)
300 		return ret;
301 
302 	instance->target = clamp_val(state, instance->lower, instance->upper);
303 	mutex_lock(&cdev->lock);
304 	cdev->updated = false;
305 	mutex_unlock(&cdev->lock);
306 	thermal_cdev_update(cdev);
307 
308 	return 0;
309 }
310 
311 /**
312  * divvy_up_power() - divvy the allocated power between the actors
313  * @req_power:	each actor's requested power
314  * @max_power:	each actor's maximum available power
315  * @num_actors:	size of the @req_power, @max_power and @granted_power's array
316  * @total_req_power: sum of @req_power
317  * @power_range:	total allocated power
318  * @granted_power:	output array: each actor's granted power
319  * @extra_actor_power:	an appropriately sized array to be used in the
320  *			function as temporary storage of the extra power given
321  *			to the actors
322  *
323  * This function divides the total allocated power (@power_range)
324  * fairly between the actors.  It first tries to give each actor a
325  * share of the @power_range according to how much power it requested
326  * compared to the rest of the actors.  For example, if only one actor
327  * requests power, then it receives all the @power_range.  If
328  * three actors each requests 1mW, each receives a third of the
329  * @power_range.
330  *
331  * If any actor received more than their maximum power, then that
332  * surplus is re-divvied among the actors based on how far they are
333  * from their respective maximums.
334  *
335  * Granted power for each actor is written to @granted_power, which
336  * should've been allocated by the calling function.
337  */
338 static void divvy_up_power(u32 *req_power, u32 *max_power, int num_actors,
339 			   u32 total_req_power, u32 power_range,
340 			   u32 *granted_power, u32 *extra_actor_power)
341 {
342 	u32 extra_power, capped_extra_power;
343 	int i;
344 
345 	/*
346 	 * Prevent division by 0 if none of the actors request power.
347 	 */
348 	if (!total_req_power)
349 		total_req_power = 1;
350 
351 	capped_extra_power = 0;
352 	extra_power = 0;
353 	for (i = 0; i < num_actors; i++) {
354 		u64 req_range = (u64)req_power[i] * power_range;
355 
356 		granted_power[i] = DIV_ROUND_CLOSEST_ULL(req_range,
357 							 total_req_power);
358 
359 		if (granted_power[i] > max_power[i]) {
360 			extra_power += granted_power[i] - max_power[i];
361 			granted_power[i] = max_power[i];
362 		}
363 
364 		extra_actor_power[i] = max_power[i] - granted_power[i];
365 		capped_extra_power += extra_actor_power[i];
366 	}
367 
368 	if (!extra_power)
369 		return;
370 
371 	/*
372 	 * Re-divvy the reclaimed extra among actors based on
373 	 * how far they are from the max
374 	 */
375 	extra_power = min(extra_power, capped_extra_power);
376 	if (capped_extra_power > 0)
377 		for (i = 0; i < num_actors; i++) {
378 			u64 extra_range = (u64)extra_actor_power[i] * extra_power;
379 			granted_power[i] += DIV_ROUND_CLOSEST_ULL(extra_range,
380 							 capped_extra_power);
381 		}
382 }
383 
384 static int allocate_power(struct thermal_zone_device *tz,
385 			  int control_temp)
386 {
387 	struct thermal_instance *instance;
388 	struct power_allocator_params *params = tz->governor_data;
389 	u32 *req_power, *max_power, *granted_power, *extra_actor_power;
390 	u32 *weighted_req_power;
391 	u32 total_req_power, max_allocatable_power, total_weighted_req_power;
392 	u32 total_granted_power, power_range;
393 	int i, num_actors, total_weight, ret = 0;
394 	int trip_max_desired_temperature = params->trip_max_desired_temperature;
395 
396 	mutex_lock(&tz->lock);
397 
398 	num_actors = 0;
399 	total_weight = 0;
400 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
401 		if ((instance->trip == trip_max_desired_temperature) &&
402 		    cdev_is_power_actor(instance->cdev)) {
403 			num_actors++;
404 			total_weight += instance->weight;
405 		}
406 	}
407 
408 	if (!num_actors) {
409 		ret = -ENODEV;
410 		goto unlock;
411 	}
412 
413 	/*
414 	 * We need to allocate five arrays of the same size:
415 	 * req_power, max_power, granted_power, extra_actor_power and
416 	 * weighted_req_power.  They are going to be needed until this
417 	 * function returns.  Allocate them all in one go to simplify
418 	 * the allocation and deallocation logic.
419 	 */
420 	BUILD_BUG_ON(sizeof(*req_power) != sizeof(*max_power));
421 	BUILD_BUG_ON(sizeof(*req_power) != sizeof(*granted_power));
422 	BUILD_BUG_ON(sizeof(*req_power) != sizeof(*extra_actor_power));
423 	BUILD_BUG_ON(sizeof(*req_power) != sizeof(*weighted_req_power));
424 	req_power = kcalloc(num_actors * 5, sizeof(*req_power), GFP_KERNEL);
425 	if (!req_power) {
426 		ret = -ENOMEM;
427 		goto unlock;
428 	}
429 
430 	max_power = &req_power[num_actors];
431 	granted_power = &req_power[2 * num_actors];
432 	extra_actor_power = &req_power[3 * num_actors];
433 	weighted_req_power = &req_power[4 * num_actors];
434 
435 	i = 0;
436 	total_weighted_req_power = 0;
437 	total_req_power = 0;
438 	max_allocatable_power = 0;
439 
440 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
441 		int weight;
442 		struct thermal_cooling_device *cdev = instance->cdev;
443 
444 		if (instance->trip != trip_max_desired_temperature)
445 			continue;
446 
447 		if (!cdev_is_power_actor(cdev))
448 			continue;
449 
450 		if (cdev->ops->get_requested_power(cdev, &req_power[i]))
451 			continue;
452 
453 		if (!total_weight)
454 			weight = 1 << FRAC_BITS;
455 		else
456 			weight = instance->weight;
457 
458 		weighted_req_power[i] = frac_to_int(weight * req_power[i]);
459 
460 		if (cdev->ops->state2power(cdev, instance->lower,
461 					   &max_power[i]))
462 			continue;
463 
464 		total_req_power += req_power[i];
465 		max_allocatable_power += max_power[i];
466 		total_weighted_req_power += weighted_req_power[i];
467 
468 		i++;
469 	}
470 
471 	power_range = pid_controller(tz, control_temp, max_allocatable_power);
472 
473 	divvy_up_power(weighted_req_power, max_power, num_actors,
474 		       total_weighted_req_power, power_range, granted_power,
475 		       extra_actor_power);
476 
477 	total_granted_power = 0;
478 	i = 0;
479 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
480 		if (instance->trip != trip_max_desired_temperature)
481 			continue;
482 
483 		if (!cdev_is_power_actor(instance->cdev))
484 			continue;
485 
486 		power_actor_set_power(instance->cdev, instance,
487 				      granted_power[i]);
488 		total_granted_power += granted_power[i];
489 
490 		i++;
491 	}
492 
493 	trace_thermal_power_allocator(tz, req_power, total_req_power,
494 				      granted_power, total_granted_power,
495 				      num_actors, power_range,
496 				      max_allocatable_power, tz->temperature,
497 				      control_temp - tz->temperature);
498 
499 	kfree(req_power);
500 unlock:
501 	mutex_unlock(&tz->lock);
502 
503 	return ret;
504 }
505 
506 /**
507  * get_governor_trips() - get the number of the two trip points that are key for this governor
508  * @tz:	thermal zone to operate on
509  * @params:	pointer to private data for this governor
510  *
511  * The power allocator governor works optimally with two trips points:
512  * a "switch on" trip point and a "maximum desired temperature".  These
513  * are defined as the first and last passive trip points.
514  *
515  * If there is only one trip point, then that's considered to be the
516  * "maximum desired temperature" trip point and the governor is always
517  * on.  If there are no passive or active trip points, then the
518  * governor won't do anything.  In fact, its throttle function
519  * won't be called at all.
520  */
521 static void get_governor_trips(struct thermal_zone_device *tz,
522 			       struct power_allocator_params *params)
523 {
524 	int i, last_active, last_passive;
525 	bool found_first_passive;
526 
527 	found_first_passive = false;
528 	last_active = INVALID_TRIP;
529 	last_passive = INVALID_TRIP;
530 
531 	for (i = 0; i < tz->trips; i++) {
532 		enum thermal_trip_type type;
533 		int ret;
534 
535 		ret = tz->ops->get_trip_type(tz, i, &type);
536 		if (ret) {
537 			dev_warn(&tz->device,
538 				 "Failed to get trip point %d type: %d\n", i,
539 				 ret);
540 			continue;
541 		}
542 
543 		if (type == THERMAL_TRIP_PASSIVE) {
544 			if (!found_first_passive) {
545 				params->trip_switch_on = i;
546 				found_first_passive = true;
547 			} else  {
548 				last_passive = i;
549 			}
550 		} else if (type == THERMAL_TRIP_ACTIVE) {
551 			last_active = i;
552 		} else {
553 			break;
554 		}
555 	}
556 
557 	if (last_passive != INVALID_TRIP) {
558 		params->trip_max_desired_temperature = last_passive;
559 	} else if (found_first_passive) {
560 		params->trip_max_desired_temperature = params->trip_switch_on;
561 		params->trip_switch_on = INVALID_TRIP;
562 	} else {
563 		params->trip_switch_on = INVALID_TRIP;
564 		params->trip_max_desired_temperature = last_active;
565 	}
566 }
567 
568 static void reset_pid_controller(struct power_allocator_params *params)
569 {
570 	params->err_integral = 0;
571 	params->prev_err = 0;
572 }
573 
574 static void allow_maximum_power(struct thermal_zone_device *tz)
575 {
576 	struct thermal_instance *instance;
577 	struct power_allocator_params *params = tz->governor_data;
578 
579 	mutex_lock(&tz->lock);
580 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
581 		if ((instance->trip != params->trip_max_desired_temperature) ||
582 		    (!cdev_is_power_actor(instance->cdev)))
583 			continue;
584 
585 		instance->target = 0;
586 		mutex_lock(&instance->cdev->lock);
587 		instance->cdev->updated = false;
588 		mutex_unlock(&instance->cdev->lock);
589 		thermal_cdev_update(instance->cdev);
590 	}
591 	mutex_unlock(&tz->lock);
592 }
593 
594 /**
595  * check_power_actors() - Check all cooling devices and warn when they are
596  *			not power actors
597  * @tz:		thermal zone to operate on
598  *
599  * Check all cooling devices in the @tz and warn every time they are missing
600  * power actor API. The warning should help to investigate the issue, which
601  * could be e.g. lack of Energy Model for a given device.
602  *
603  * Return: 0 on success, -EINVAL if any cooling device does not implement
604  * the power actor API.
605  */
606 static int check_power_actors(struct thermal_zone_device *tz)
607 {
608 	struct thermal_instance *instance;
609 	int ret = 0;
610 
611 	list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
612 		if (!cdev_is_power_actor(instance->cdev)) {
613 			dev_warn(&tz->device, "power_allocator: %s is not a power actor\n",
614 				 instance->cdev->type);
615 			ret = -EINVAL;
616 		}
617 	}
618 
619 	return ret;
620 }
621 
622 /**
623  * power_allocator_bind() - bind the power_allocator governor to a thermal zone
624  * @tz:	thermal zone to bind it to
625  *
626  * Initialize the PID controller parameters and bind it to the thermal
627  * zone.
628  *
629  * Return: 0 on success, or -ENOMEM if we ran out of memory, or -EINVAL
630  * when there are unsupported cooling devices in the @tz.
631  */
632 static int power_allocator_bind(struct thermal_zone_device *tz)
633 {
634 	int ret;
635 	struct power_allocator_params *params;
636 	int control_temp;
637 
638 	ret = check_power_actors(tz);
639 	if (ret)
640 		return ret;
641 
642 	params = kzalloc(sizeof(*params), GFP_KERNEL);
643 	if (!params)
644 		return -ENOMEM;
645 
646 	if (!tz->tzp) {
647 		tz->tzp = kzalloc(sizeof(*tz->tzp), GFP_KERNEL);
648 		if (!tz->tzp) {
649 			ret = -ENOMEM;
650 			goto free_params;
651 		}
652 
653 		params->allocated_tzp = true;
654 	}
655 
656 	if (!tz->tzp->sustainable_power)
657 		dev_warn(&tz->device, "power_allocator: sustainable_power will be estimated\n");
658 
659 	get_governor_trips(tz, params);
660 
661 	if (tz->trips > 0) {
662 		ret = tz->ops->get_trip_temp(tz,
663 					params->trip_max_desired_temperature,
664 					&control_temp);
665 		if (!ret)
666 			estimate_pid_constants(tz, tz->tzp->sustainable_power,
667 					       params->trip_switch_on,
668 					       control_temp);
669 	}
670 
671 	reset_pid_controller(params);
672 
673 	tz->governor_data = params;
674 
675 	return 0;
676 
677 free_params:
678 	kfree(params);
679 
680 	return ret;
681 }
682 
683 static void power_allocator_unbind(struct thermal_zone_device *tz)
684 {
685 	struct power_allocator_params *params = tz->governor_data;
686 
687 	dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id);
688 
689 	if (params->allocated_tzp) {
690 		kfree(tz->tzp);
691 		tz->tzp = NULL;
692 	}
693 
694 	kfree(tz->governor_data);
695 	tz->governor_data = NULL;
696 }
697 
698 static int power_allocator_throttle(struct thermal_zone_device *tz, int trip)
699 {
700 	int ret;
701 	int switch_on_temp, control_temp;
702 	struct power_allocator_params *params = tz->governor_data;
703 
704 	/*
705 	 * We get called for every trip point but we only need to do
706 	 * our calculations once
707 	 */
708 	if (trip != params->trip_max_desired_temperature)
709 		return 0;
710 
711 	ret = tz->ops->get_trip_temp(tz, params->trip_switch_on,
712 				     &switch_on_temp);
713 	if (!ret && (tz->temperature < switch_on_temp)) {
714 		tz->passive = 0;
715 		reset_pid_controller(params);
716 		allow_maximum_power(tz);
717 		return 0;
718 	}
719 
720 	tz->passive = 1;
721 
722 	ret = tz->ops->get_trip_temp(tz, params->trip_max_desired_temperature,
723 				&control_temp);
724 	if (ret) {
725 		dev_warn(&tz->device,
726 			 "Failed to get the maximum desired temperature: %d\n",
727 			 ret);
728 		return ret;
729 	}
730 
731 	return allocate_power(tz, control_temp);
732 }
733 
734 static struct thermal_governor thermal_gov_power_allocator = {
735 	.name		= "power_allocator",
736 	.bind_to_tz	= power_allocator_bind,
737 	.unbind_from_tz	= power_allocator_unbind,
738 	.throttle	= power_allocator_throttle,
739 };
740 THERMAL_GOVERNOR_DECLARE(thermal_gov_power_allocator);
741