xref: /linux/arch/sparc/include/asm/mman.h (revision 249ebf3f65f8530beb2cbfb91bff1d83ba88d23c)
1 /* SPDX-License-Identifier: GPL-2.0 */
2 #ifndef __SPARC_MMAN_H__
3 #define __SPARC_MMAN_H__
4 
5 #include <uapi/asm/mman.h>
6 
7 #ifndef __ASSEMBLY__
8 #define arch_mmap_check(addr,len,flags)	sparc_mmap_check(addr,len)
9 int sparc_mmap_check(unsigned long addr, unsigned long len);
10 
11 #ifdef CONFIG_SPARC64
12 #include <asm/adi_64.h>
13 
14 static inline void ipi_set_tstate_mcde(void *arg)
15 {
16 	struct mm_struct *mm = arg;
17 
18 	/* Set TSTATE_MCDE for the task using address map that ADI has been
19 	 * enabled on if the task is running. If not, it will be set
20 	 * automatically at the next context switch
21 	 */
22 	if (current->mm == mm) {
23 		struct pt_regs *regs;
24 
25 		regs = task_pt_regs(current);
26 		regs->tstate |= TSTATE_MCDE;
27 	}
28 }
29 
30 #define arch_calc_vm_prot_bits(prot, pkey) sparc_calc_vm_prot_bits(prot)
31 static inline unsigned long sparc_calc_vm_prot_bits(unsigned long prot)
32 {
33 	if (adi_capable() && (prot & PROT_ADI)) {
34 		struct pt_regs *regs;
35 
36 		if (!current->mm->context.adi) {
37 			regs = task_pt_regs(current);
38 			regs->tstate |= TSTATE_MCDE;
39 			current->mm->context.adi = true;
40 			on_each_cpu_mask(mm_cpumask(current->mm),
41 					 ipi_set_tstate_mcde, current->mm, 0);
42 		}
43 		return VM_SPARC_ADI;
44 	} else {
45 		return 0;
46 	}
47 }
48 
49 #define arch_validate_prot(prot, addr) sparc_validate_prot(prot, addr)
50 static inline int sparc_validate_prot(unsigned long prot, unsigned long addr)
51 {
52 	if (prot & ~(PROT_READ | PROT_WRITE | PROT_EXEC | PROT_SEM | PROT_ADI))
53 		return 0;
54 	return 1;
55 }
56 
57 #define arch_validate_flags(vm_flags) arch_validate_flags(vm_flags)
58 /* arch_validate_flags() - Ensure combination of flags is valid for a
59  *	VMA.
60  */
61 static inline bool arch_validate_flags(unsigned long vm_flags)
62 {
63 	/* If ADI is being enabled on this VMA, check for ADI
64 	 * capability on the platform and ensure VMA is suitable
65 	 * for ADI
66 	 */
67 	if (vm_flags & VM_SPARC_ADI) {
68 		if (!adi_capable())
69 			return false;
70 
71 		/* ADI can not be enabled on PFN mapped pages */
72 		if (vm_flags & (VM_PFNMAP | VM_MIXEDMAP))
73 			return false;
74 
75 		/* Mergeable pages can become unmergeable
76 		 * if ADI is enabled on them even if they
77 		 * have identical data on them. This can be
78 		 * because ADI enabled pages with identical
79 		 * data may still not have identical ADI
80 		 * tags on them. Disallow ADI on mergeable
81 		 * pages.
82 		 */
83 		if (vm_flags & VM_MERGEABLE)
84 			return false;
85 	}
86 	return true;
87 }
88 #endif /* CONFIG_SPARC64 */
89 
90 #endif /* __ASSEMBLY__ */
91 #endif /* __SPARC_MMAN_H__ */
92