1.. SPDX-License-Identifier: GFDL-1.1-no-invariants-or-later 2.. c:namespace:: V4L 3 4.. _VIDIOC_G_SLICED_VBI_CAP: 5 6***************************** 7ioctl VIDIOC_G_SLICED_VBI_CAP 8***************************** 9 10Name 11==== 12 13VIDIOC_G_SLICED_VBI_CAP - Query sliced VBI capabilities 14 15Synopsis 16======== 17 18.. c:macro:: VIDIOC_G_SLICED_VBI_CAP 19 20``int ioctl(int fd, VIDIOC_G_SLICED_VBI_CAP, struct v4l2_sliced_vbi_cap *argp)`` 21 22Arguments 23========= 24 25``fd`` 26 File descriptor returned by :c:func:`open()`. 27 28``argp`` 29 Pointer to struct :c:type:`v4l2_sliced_vbi_cap`. 30 31Description 32=========== 33 34To find out which data services are supported by a sliced VBI capture or 35output device, applications initialize the ``type`` field of a struct 36:c:type:`v4l2_sliced_vbi_cap`, clear the 37``reserved`` array and call the :ref:`VIDIOC_G_SLICED_VBI_CAP <VIDIOC_G_SLICED_VBI_CAP>` ioctl. The 38driver fills in the remaining fields or returns an ``EINVAL`` error code if 39the sliced VBI API is unsupported or ``type`` is invalid. 40 41.. note:: 42 43 The ``type`` field was added, and the ioctl changed from read-only 44 to write-read, in Linux 2.6.19. 45 46.. c:type:: v4l2_sliced_vbi_cap 47 48.. tabularcolumns:: |p{1.2cm}|p{4.2cm}|p{4.1cm}|p{4.0cm}|p{4.0cm}| 49 50.. flat-table:: struct v4l2_sliced_vbi_cap 51 :header-rows: 0 52 :stub-columns: 0 53 :widths: 3 3 2 2 2 54 55 * - __u16 56 - ``service_set`` 57 - :cspan:`2` A set of all data services supported by the driver. 58 59 Equal to the union of all elements of the ``service_lines`` array. 60 * - __u16 61 - ``service_lines``\ [2][24] 62 - :cspan:`2` Each element of this array contains a set of data 63 services the hardware can look for or insert into a particular 64 scan line. Data services are defined in :ref:`vbi-services`. 65 Array indices map to ITU-R line numbers\ [#f1]_ as follows: 66 * - 67 - 68 - Element 69 - 525 line systems 70 - 625 line systems 71 * - 72 - 73 - ``service_lines``\ [0][1] 74 - 1 75 - 1 76 * - 77 - 78 - ``service_lines``\ [0][23] 79 - 23 80 - 23 81 * - 82 - 83 - ``service_lines``\ [1][1] 84 - 264 85 - 314 86 * - 87 - 88 - ``service_lines``\ [1][23] 89 - 286 90 - 336 91 * - 92 * - 93 - 94 - :cspan:`2` The number of VBI lines the hardware can capture or 95 output per frame, or the number of services it can identify on a 96 given line may be limited. For example on PAL line 16 the hardware 97 may be able to look for a VPS or Teletext signal, but not both at 98 the same time. Applications can learn about these limits using the 99 :ref:`VIDIOC_S_FMT <VIDIOC_G_FMT>` ioctl as described in 100 :ref:`sliced`. 101 * - 102 * - 103 - 104 - :cspan:`2` Drivers must set ``service_lines`` [0][0] and 105 ``service_lines``\ [1][0] to zero. 106 * - __u32 107 - ``type`` 108 - Type of the data stream, see :c:type:`v4l2_buf_type`. Should be 109 ``V4L2_BUF_TYPE_SLICED_VBI_CAPTURE`` or 110 ``V4L2_BUF_TYPE_SLICED_VBI_OUTPUT``. 111 * - __u32 112 - ``reserved``\ [3] 113 - :cspan:`2` This array is reserved for future extensions. 114 115 Applications and drivers must set it to zero. 116 117.. [#f1] 118 119 See also :ref:`vbi-525` and :ref:`vbi-625`. 120 121.. raw:: latex 122 123 \scriptsize 124 125.. tabularcolumns:: |p{3.5cm}|p{1.0cm}|p{2.0cm}|p{2.0cm}|p{8.0cm}| 126 127.. _vbi-services: 128 129.. flat-table:: Sliced VBI services 130 :header-rows: 1 131 :stub-columns: 0 132 :widths: 2 1 1 2 2 133 134 * - Symbol 135 - Value 136 - Reference 137 - Lines, usually 138 - Payload 139 * - ``V4L2_SLICED_TELETEXT_B`` (Teletext System B) 140 - 0x0001 141 - :ref:`ets300706`, 142 143 :ref:`itu653` 144 - PAL/SECAM line 7-22, 320-335 (second field 7-22) 145 - Last 42 of the 45 byte Teletext packet, that is without clock 146 run-in and framing code, lsb first transmitted. 147 * - ``V4L2_SLICED_VPS`` 148 - 0x0400 149 - :ref:`ets300231` 150 - PAL line 16 151 - Byte number 3 to 15 according to Figure 9 of ETS 300 231, lsb 152 first transmitted. 153 * - ``V4L2_SLICED_CAPTION_525`` 154 - 0x1000 155 - :ref:`cea608` 156 - NTSC line 21, 284 (second field 21) 157 - Two bytes in transmission order, including parity bit, lsb first 158 transmitted. 159 * - ``V4L2_SLICED_WSS_625`` 160 - 0x4000 161 - :ref:`en300294`, 162 163 :ref:`itu1119` 164 - PAL/SECAM line 23 165 - 166 167 :: 168 169 Byte 0 1 170 msb lsb msb lsb 171 Bit 7 6 5 4 3 2 1 0 x x 13 12 11 10 9 172 * - ``V4L2_SLICED_VBI_525`` 173 - 0x1000 174 - :cspan:`2` Set of services applicable to 525 line systems. 175 * - ``V4L2_SLICED_VBI_625`` 176 - 0x4401 177 - :cspan:`2` Set of services applicable to 625 line systems. 178 179.. raw:: latex 180 181 \normalsize 182 183Return Value 184============ 185 186On success 0 is returned, on error -1 and the ``errno`` variable is set 187appropriately. The generic error codes are described at the 188:ref:`Generic Error Codes <gen-errors>` chapter. 189 190EINVAL 191 The value in the ``type`` field is wrong. 192