xref: /linux/Documentation/usb/mtouchusb.rst (revision c532de5a67a70f8533d495f8f2aaa9a0491c3ad0)
1================
2mtouchusb driver
3================
4
5Changes
6=======
7
8- 0.3 - Created based off of scanner & INSTALL from the original touchscreen
9  driver on freecode (http://freecode.com/projects/3mtouchscreendriver)
10- Amended for linux-2.4.18, then 2.4.19
11
12- 0.5 - Complete rewrite using Linux Input in 2.6.3
13  Unfortunately no calibration support at this time
14
15- 1.4 - Multiple changes to support the EXII 5000UC and house cleaning
16  Changed reset from standard USB dev reset to vendor reset
17  Changed data sent to host from compensated to raw coordinates
18  Eliminated vendor/product module params
19  Performed multiple successful tests with an EXII-5010UC
20
21Supported Hardware
22==================
23
24::
25
26        All controllers have the Vendor: 0x0596 & Product: 0x0001
27
28
29        Controller Description          Part Number
30        ------------------------------------------------------
31
32        USB Capacitive - Pearl Case     14-205  (Discontinued)
33        USB Capacitive - Black Case     14-124  (Discontinued)
34        USB Capacitive - No Case        14-206  (Discontinued)
35
36        USB Capacitive - Pearl Case     EXII-5010UC
37        USB Capacitive - Black Case     EXII-5030UC
38        USB Capacitive - No Case        EXII-5050UC
39
40Driver Notes
41============
42
43Installation is simple, you only need to add Linux Input, Linux USB, and the
44driver to the kernel.  The driver can also be optionally built as a module.
45
46This driver appears to be one of possible 2 Linux USB Input Touchscreen
47drivers.  Although 3M produces a binary only driver available for
48download, I persist in updating this driver since I would like to use the
49touchscreen for embedded apps using QTEmbedded, DirectFB, etc. So I feel the
50logical choice is to use Linux Input.
51
52Currently there is no way to calibrate the device via this driver.  Even if
53the device could be calibrated, the driver pulls to raw coordinate data from
54the controller.  This means calibration must be performed within the
55userspace.
56
57The controller screen resolution is now 0 to 16384 for both X and Y reporting
58the raw touch data.  This is the same for the old and new capacitive USB
59controllers.
60
61Perhaps at some point an abstract function will be placed into evdev so
62generic functions like calibrations, resets, and vendor information can be
63requested from the userspace (And the drivers would handle the vendor specific
64tasks).
65
66TODO
67====
68
69Implement a control urb again to handle requests to and from the device
70such as calibration, etc once/if it becomes available.
71
72Disclaimer
73==========
74
75I am not a MicroTouch/3M employee, nor have I ever been.  3M does not support
76this driver!  If you want touch drivers only supported within X, please go to:
77
78http://www.3m.com/3MTouchSystems/
79
80Thanks
81======
82
83A huge thank you to 3M Touch Systems for the EXII-5010UC controllers for
84testing!