xref: /linux/Documentation/hwmon/ltc4282.rst (revision ef9226cd56b718c79184a3466d32984a51cb449c)
1.. SPDX-License-Identifier: GPL-2.0-only
2
3Kernel drivers ltc4282
4==========================================
5
6Supported chips:
7
8  * Analog Devices LTC4282
9
10    Prefix: 'ltc4282'
11
12    Addresses scanned: - I2C 0x40 - 0x5A (7-bit)
13    Addresses scanned: - I2C 0x80 - 0xB4 with a step of 2 (8-bit)
14
15    Datasheet:
16
17        https://www.analog.com/media/en/technical-documentation/data-sheets/ltc4282.pdf
18
19Author: Nuno Sá <nuno.sa@analog.com>
20
21Description
22___________
23
24The LTC4282 hot swap controller allows a board to be safely inserted and removed
25from a live backplane. Using one or more external N-channel pass transistors,
26board supply voltage and inrush current are ramped up at an adjustable rate. An
27I2C interface and onboard ADC allows for monitoring of board current, voltage,
28power, energy and fault status. The device features analog foldback current
29limiting and supply monitoring for applications from 2.9V to 33V. Dual 12V gate
30drive allows high power applications to either share safe operating area across
31parallel MOSFETs or support a 2-stage start-up that first charges the load
32capacitance followed by enabling a low on-resistance path to the load. The
33LTC4282 is well suited to high power applications because the precise monitoring
34capability and accurate current limiting reduce the extremes in which both loads
35and power supplies must safely operate. Non-volatile configuration allows for
36flexibility in the autonomous generation of alerts and response to faults.
37
38Sysfs entries
39_____________
40
41The following attributes are supported. Limits are read-write and all the other
42attributes are read-only. Note that in0 and in1 are mutually exclusive. Enabling
43one disables the other and disabling one enables the other.
44
45======================= ==========================================
46in0_input		Output voltage (mV).
47in0_min			Undervoltage threshold
48in0_max                 Overvoltage threshold
49in0_lowest		Lowest measured voltage
50in0_highest		Highest measured voltage
51in0_reset_history	Write 1 to reset in0 history.
52			Also clears fet bad and short fault logs.
53in0_min_alarm		Undervoltage alarm
54in0_max_alarm           Overvoltage alarm
55in0_enable		Enable/Disable VSOURCE monitoring
56in0_fault		Failure in the MOSFETs. Either bad or shorted FET.
57in0_label		Channel label (VSOURCE)
58
59in1_input		Input voltage (mV).
60in1_min			Undervoltage threshold
61in1_max                 Overvoltage threshold
62in1_lowest		Lowest measured voltage
63in1_highest		Highest measured voltage
64in1_reset_history	Write 1 to reset in1 history.
65			Also clears over/undervoltage fault logs.
66in1_min_alarm		Undervoltage alarm
67in1_max_alarm           Overvoltage alarm
68in1_lcrit_alarm         Critical Undervoltage alarm
69in1_crit_alarm          Critical Overvoltage alarm
70in1_enable		Enable/Disable VDD monitoring
71in1_label		Channel label (VDD)
72
73in2_input		GPIO voltage (mV)
74in2_min			Undervoltage threshold
75in2_max			Overvoltage threshold
76in2_lowest		Lowest measured voltage
77in2_highest		Highest measured voltage
78in2_reset_history	Write 1 to reset in2 history
79in2_min_alarm		Undervoltage alarm
80in2_max_alarm		Overvoltage alarm
81in2_label		Channel label (VGPIO)
82
83curr1_input		Sense current (mA)
84curr1_min		Undercurrent threshold
85curr1_max		Overcurrent threshold
86curr1_lowest		Lowest measured current
87curr1_highest		Highest measured current
88curr1_reset_history	Write 1 to reset curr1 history.
89			Also clears overcurrent fault logs.
90curr1_min_alarm		Undercurrent alarm
91curr1_max_alarm		Overcurrent alarm
92curr1_crit_alarm        Critical Overcurrent alarm
93curr1_label		Channel label (ISENSE)
94
95power1_input		Power (in uW)
96power1_min		Low power threshold
97power1_max		High power threshold
98power1_input_lowest	Historical minimum power use
99power1_input_highest	Historical maximum power use
100power1_reset_history	Write 1 to reset power1 history.
101			Also clears power bad fault logs.
102power1_min_alarm	Low power alarm
103power1_max_alarm	High power alarm
104power1_label		Channel label (Power)
105
106energy1_input		Measured energy over time (in microJoule)
107energy1_enable		Enable/Disable Energy accumulation
108======================= ==========================================
109
110DebugFs entries
111_______________
112
113The chip also has a fault log register where failures can be logged. Hence,
114as these are logging events, we give access to them in debugfs. Note that
115even if some failure is detected in these logs, it does necessarily mean
116that the failure is still present. As mentioned in the proper Sysfs entries,
117these logs can be cleared by writing in the proper reset_history attribute.
118
119.. warning:: The debugfs interface is subject to change without notice
120             and is only available when the kernel is compiled with
121             ``CONFIG_DEBUG_FS`` defined.
122
123``/sys/kernel/debug/ltc4282-hwmon[X]/``
124contains the following attributes:
125
126=======================  ==========================================
127power1_bad_fault_log     Set to 1 by a power1 bad fault occurring.
128in0_fet_short_fault_log	 Set to 1 when the ADC detects a FET-short fault.
129in0_fet_bad_fault_log    Set to 1 when a FET-BAD fault occurs.
130in1_crit_fault_log       Set to 1 by a VDD overvoltage fault occurring.
131in1_lcrit_fault_log      Set to 1 by a VDD undervoltage fault occurring.
132curr1_crit_fault_log	 Set to 1 by an overcurrent fault occurring.
133=======================  ==========================================