11
12description: |
13  Devices work at voltage-current-frequency combinations and some implementations
14  have the liberty of choosing these. These combinations are called Operating
15  Performance Points aka OPPs. This document defines bindings for these OPPs
16  applicable across wide range of devices. For illustration purpose, this document
17  uses CPU as a device.
18
19  This describes the OPPs belonging to a device.
20
21select: false
22
23properties:
24  $nodename:
25    pattern: '^opp-table(-[a-z0-9]+)?$'
26
27  opp-shared:
28    description:
29      Indicates that device nodes using this OPP Table Node's phandle switch
30      their DVFS state together, i.e. they share clock/voltage/current lines.
31      Missing property means devices have independent clock/voltage/current
32      lines, but they share OPP tables.
33    type: boolean
34
35patternProperties:
36  '^opp(-?[0-9]+)*$':
37    type: object
38    description:
39      One or more OPP nodes describing voltage-current-frequency combinations.
40      Their name isn't significant but their phandle can be used to reference an
41      OPP. These are mandatory except for the case where the OPP table is
42      present only to indicate dependency between devices using the opp-shared
43      property.
44
45    properties:
46      opp-hz:
47        description:
48          Frequency in Hz, expressed as a 64-bit big-endian integer. This is a
49          required property for all device nodes, unless another "required"
50          property to uniquely identify the OPP nodes exists. Devices like power
51          domains must have another (implementation dependent) property.
52
53          Entries for multiple clocks shall be provided in the same field, as
54          array of frequencies.  The OPP binding doesn't provide any provisions
55          to relate the values to their clocks or the order in which the clocks
56          need to be configured and that is left for the implementation
57          specific binding.
58        minItems: 1
59        maxItems: 32
60
61      opp-microvolt:
62        description: |
63          Voltage for the OPP
64
65          A single regulator's voltage is specified with an array of size one or three.
66          Single entry is for target voltage and three entries are for <target min max>
67          voltages.
68
69          Entries for multiple regulators shall be provided in the same field separated
70          by angular brackets <>. The OPP binding doesn't provide any provisions to
71          relate the values to their power supplies or the order in which the supplies
72          need to be configured and that is left for the implementation specific
73          binding.
74
75          Entries for all regulators shall be of the same size, i.e. either all use a
76          single value or triplets.
77        minItems: 1
78        maxItems: 8   # Should be enough regulators
79        items:
80          minItems: 1
81          maxItems: 3
82
83      opp-microamp:
84        description: |
85          The maximum current drawn by the device in microamperes considering
86          system specific parameters (such as transients, process, aging,
87          maximum operating temperature range etc.) as necessary. This may be
88          used to set the most efficient regulator operating mode.
89
90          Should only be set if opp-microvolt or opp-microvolt-<name> is set for
91          the OPP.
92
93          Entries for multiple regulators shall be provided in the same field
94          separated by angular brackets <>. If current values aren't required
95          for a regulator, then it shall be filled with 0. If current values
96          aren't required for any of the regulators, then this field is not
97          required. The OPP binding doesn't provide any provisions to relate the
98          values to their power supplies or the order in which the supplies need
99          to be configured and that is left for the implementation specific
100          binding.
101        minItems: 1
102        maxItems: 8   # Should be enough regulators
103
104      opp-microwatt:
105        description: |
106          The power for the OPP in micro-Watts.
107
108          Entries for multiple regulators shall be provided in the same field
109          separated by angular brackets <>. If power values aren't required
110          for a regulator, then it shall be filled with 0. If power values
111          aren't required for any of the regulators, then this field is not
112          required. The OPP binding doesn't provide any provisions to relate the
113          values to their power supplies or the order in which the supplies need
114          to be configured and that is left for the implementation specific
115          binding.
116        minItems: 1
117        maxItems: 8   # Should be enough regulators
118
119      opp-level:
120        description:
121          A value representing the performance level of the device.
122        $ref: /schemas/types.yaml#/definitions/uint32
123
124      opp-peak-kBps:
125        description:
126          Peak bandwidth in kilobytes per second, expressed as an array of
127          32-bit big-endian integers. Each element of the array represents the
128          peak bandwidth value of each interconnect path. The number of elements
129          should match the number of interconnect paths.
130        minItems: 1
131        maxItems: 32  # Should be enough
132
133      opp-avg-kBps:
134        description:
135          Average bandwidth in kilobytes per second, expressed as an array
136          of 32-bit big-endian integers. Each element of the array represents the
137          average bandwidth value of each interconnect path. The number of elements
138          should match the number of interconnect paths. This property is only
139          meaningful in OPP tables where opp-peak-kBps is present.
140        minItems: 1
141        maxItems: 32  # Should be enough
142
143      clock-latency-ns:
144        description:
145          Specifies the maximum possible transition latency (in nanoseconds) for
146          switching to this OPP from any other OPP.
147
148      turbo-mode:
149        description:
150          Marks the OPP to be used only for turbo modes. Turbo mode is available
151          on some platforms, where the device can run over its operating
152          frequency for a short duration of time limited by the device's power,
153          current and thermal limits.
154        type: boolean
155
156      opp-suspend:
157        description:
158          Marks the OPP to be used during device suspend. If multiple OPPs in
159          the table have this, the OPP with highest opp-hz will be used.
160        type: boolean
161
162      opp-supported-hw:
163        description: |
164          This property allows a platform to enable only a subset of the OPPs
165          from the larger set present in the OPP table, based on the current
166          version of the hardware (already known to the operating system).
167
168          Each block present in the array of blocks in this property, represents
169          a sub-group of hardware versions supported by the OPP. i.e. <sub-group
170          A>, <sub-group B>, etc. The OPP will be enabled if _any_ of these
171          sub-groups match the hardware's version.
172
173          Each sub-group is a platform defined array representing the hierarchy
174          of hardware versions supported by the platform. For a platform with
175          three hierarchical levels of version (X.Y.Z), this field shall look
176          like
177
178          opp-supported-hw = <X1 Y1 Z1>, <X2 Y2 Z2>, <X3 Y3 Z3>.
179
180          Each level (eg. X1) in version hierarchy is represented by a 32 bit
181          value, one bit per version and so there can be maximum 32 versions per
182          level. Logical AND (&) operation is performed for each level with the
183          hardware's level version and a non-zero output for _all_ the levels in
184          a sub-group means the OPP is supported by hardware. A value of
185          0xFFFFFFFF for each level in the sub-group will enable the OPP for all
186          versions for the hardware.
187        $ref: /schemas/types.yaml#/definitions/uint32-matrix
188        maxItems: 32
189        items:
190          minItems: 1
191          maxItems: 4
192
193      required-opps:
194        description:
195          This contains phandle to an OPP node in another device's OPP table. It
196          may contain an array of phandles, where each phandle points to an OPP
197          of a different device. It should not contain multiple phandles to the
198          OPP nodes in the same OPP table. This specifies the minimum required
199          OPP of the device(s), whose OPP's phandle is present in this property,
200          for the functioning of the current device at the current OPP (where
201          this property is present).
202        $ref: /schemas/types.yaml#/definitions/phandle-array
203        items:
204          maxItems: 1
205
206    patternProperties:
207      '^opp-microvolt-':
208        description:
209          Named opp-microvolt property. This is exactly similar to the above
210          opp-microvolt property, but allows multiple voltage ranges to be
211          provided for the same OPP. At runtime, the platform can pick a <name>
212          and matching opp-microvolt-<name> property will be enabled for all
213          OPPs. If the platform doesn't pick a specific <name> or the <name>
214          doesn't match with any opp-microvolt-<name> properties, then
215          opp-microvolt property shall be used, if present.
216        $ref: /schemas/types.yaml#/definitions/uint32-matrix
217        minItems: 1
218        maxItems: 8   # Should be enough regulators
219        items:
220          minItems: 1
221          maxItems: 3
222
223      '^opp-microamp-':
224        description:
225          Named opp-microamp property. Similar to opp-microvolt-<name> property,
226          but for microamp instead.
227        $ref: /schemas/types.yaml#/definitions/uint32-array
228        minItems: 1
229        maxItems: 8   # Should be enough regulators
230
231      '^opp-microwatt-':
232        description:
233          Named opp-microwatt property. Similar to opp-microamp-<name> property,
234          but for microwatt instead.
235        $ref: /schemas/types.yaml#/definitions/uint32-array
236        minItems: 1
237        maxItems: 8   # Should be enough regulators
238
239    dependencies:
240      opp-avg-kBps: [ opp-peak-kBps ]
241
242required:
243  - compatible
244
245additionalProperties: true
246