1What:		/sys/class/scsi_host/hostX/isci_id
2Date:		June 2011
3Contact:	Dave Jiang <dave.jiang@intel.com>
4Description:
5		This file contains the enumerated host ID for the Intel
6		SCU controller. The Intel(R) C600 Series Chipset SATA/SAS
7		Storage Control Unit embeds up to two 4-port controllers in
8		a single PCI device.  The controllers are enumerated in order
9		which usually means the lowest number scsi_host corresponds
10		with the first controller, but this association is not
11		guaranteed.  The 'isci_id' attribute unambiguously identifies
12		the controller index: '0' for the first controller,
13		'1' for the second.
14
15What:		/sys/class/scsi_host/hostX/acciopath_status
16Date:		November 2013
17Contact:	Stephen M. Cameron <scameron@beardog.cce.hp.com>
18Description:	This file contains the current status of the "SSD Smart Path"
19		feature of HP Smart Array RAID controllers using the hpsa
20		driver.  SSD Smart Path, when enabled permits the driver to
21		send i/o requests directly to physical devices that are part
22		of a logical drive, bypassing the controllers firmware RAID
23		stack for a performance advantage when possible.  A value of
24		'1' indicates the feature is enabled, and the controller may
25		use the direct i/o path to physical devices.  A value of zero
26		means the feature is disabled and the controller may not use
27		the direct i/o path to physical devices.  This setting is
28		controller wide, affecting all configured logical drives on the
29		controller.  This file is readable and writable.
30
31What:		/sys/class/scsi_host/hostX/link_power_management_policy
32Date:		Oct, 2007
33KernelVersion:	v2.6.24
34Contact:	linux-ide@vger.kernel.org
35Description:
36		(RW) This parameter allows the user to read and set the link
37		(interface) power management.
38
39		There are four possible options:
40
41		min_power: Tell the controller to try to make the link use the
42		least possible power when possible. This may sacrifice some
43		performance due to increased latency when coming out of lower
44		power states.
45
46		max_performance: Generally, this means no power management.
47		Tell the controller to have performance be a priority over power
48		management.
49
50		medium_power: Tell the controller to enter a lower power state
51		when possible, but do not enter the lowest power state, thus
52		improving latency over min_power setting.
53
54		med_power_with_dipm: Identical to the existing medium_power
55		setting except that it enables dipm (device initiated power
56		management) on top, which makes it match the Windows IRST (Intel
57		Rapid Storage Technology) driver settings. This setting is also
58		close to min_power, except that:
59
60		a) It does not use host-initiated slumber mode, but it does
61		   allow device-initiated slumber
62		b) It does not enable low power device sleep mode (DevSlp).
63
64What:		/sys/class/scsi_host/hostX/em_message
65What:		/sys/class/scsi_host/hostX/em_message_type
66Date:		Jun, 2008
67KernelVersion:	v2.6.27
68Contact:	linux-ide@vger.kernel.org
69Description:
70		em_message: (RW) Enclosure management support. For the LED
71		protocol, writes and reads correspond to the LED message format
72		as defined in the AHCI spec.
73
74		The user must turn sw_activity (under `/sys/block/*/device/`)
75		OFF it they wish to control the activity LED via the em_message
76		file.
77
78		em_message_type: (RO) Displays the current enclosure management
79		protocol that is being used by the driver (for eg. LED, SAF-TE,
80		SES-2, SGPIO etc).
81
82What:		/sys/class/scsi_host/hostX/ahci_port_cmd
83What:		/sys/class/scsi_host/hostX/ahci_host_caps
84What:		/sys/class/scsi_host/hostX/ahci_host_cap2
85Date:		Mar, 2010
86KernelVersion:	v2.6.35
87Contact:	linux-ide@vger.kernel.org
88Description:
89		[to be documented]
90
91What:		/sys/class/scsi_host/hostX/ahci_host_version
92Date:		Mar, 2010
93KernelVersion:	v2.6.35
94Contact:	linux-ide@vger.kernel.org
95Description:
96		(RO) Display the version of the AHCI spec implemented by the
97		host.
98
99What:		/sys/class/scsi_host/hostX/em_buffer
100Date:		Apr, 2010
101KernelVersion:	v2.6.35
102Contact:	linux-ide@vger.kernel.org
103Description:
104		(RW) Allows access to AHCI EM (enclosure management) buffer
105		directly if the host supports EM.
106
107		For eg. the AHCI driver supports SGPIO EM messages but the
108		SATA/AHCI specs do not define the SGPIO message format of the EM
109		buffer. Different hardware(HW) vendors may have different
110		definitions. With the em_buffer attribute, this issue can be
111		solved by allowing HW vendors to provide userland drivers and
112		tools for their SGPIO initiators.
113
114What:		/sys/class/scsi_host/hostX/em_message_supported
115Date:		Oct, 2009
116KernelVersion:	v2.6.39
117Contact:	linux-ide@vger.kernel.org
118Description:
119		(RO) Displays supported enclosure management message types.