xref: /linux/Documentation/ABI/testing/sysfs-class-power-ltc4162l (revision 9dbbc3b9d09d6deba9f3b9e1d5b355032ed46a75)
1What:		/sys/class/power_supply/ltc4162-l/charge_status
2Date:		Januari 2021
3KernelVersion:	5.11
4Description:
5		Detailed charge status information as reported by the chip.
6
7		Access: Read
8
9		Valid values:
10			ilim_reg_active
11			thermal_reg_active
12			vin_uvcl_active
13			iin_limit_active
14			constant_current
15			constant_voltage
16			charger_off
17
18What:		/sys/class/power_supply/ltc4162-l/ibat
19Date:		Januari 2021
20KernelVersion:	5.11
21Description:
22		Battery input current as measured by the charger. Negative value
23		means that the battery is discharging.
24
25		Access: Read
26
27		Valid values: Signed value in microamps
28
29What:		/sys/class/power_supply/ltc4162-l/vbat
30Date:		Januari 2021
31KernelVersion:	5.11
32Description:
33		Battery voltage as measured by the charger.
34
35		Access: Read
36
37		Valid values: In microvolts
38
39What:		/sys/class/power_supply/ltc4162-l/vbat_avg
40Date:		Januari 2021
41KernelVersion:	5.11
42Description:
43		Battery voltage, averaged over time, as measured by the charger.
44
45		Access: Read
46
47		Valid values: In microvolts
48
49What:		/sys/class/power_supply/ltc4162-l/force_telemetry
50Date:		Januari 2021
51KernelVersion:	5.11
52Description:
53		To save battery current, the measurement system is disabled if
54		the battery is the only source of power. This affects all
55		voltage, current and temperature measurements.
56		Write a "1" to this to keep performing telemetry once every few
57		seconds, even when running on battery (as reported by the online
58		property, which is "1" when external power is available and "0"
59		when the system runs on battery).
60
61		Access: Read, Write
62
63		Valid values: 0 (disabled) or 1 (enabled)
64
65What:		/sys/class/power_supply/ltc4162-l/arm_ship_mode
66Date:		Januari 2021
67KernelVersion:	5.11
68Description:
69		The charger will normally drain the battery while inactive,
70		typically drawing about 54 microamps. Write a "1" to this
71		property to arm a special "ship" mode that extends shelf life
72		by reducing the leakage to about 2.8 microamps. The chip will
73		remain in this mode (and no longer respond to I2C commands)
74		until some external power-supply is attached raising the input
75		voltage above 1V. It will then automatically revert to "0".
76		Writing a "0" to the property cancels the "ship" mode request.
77		The ship mode, when armed, activates once the input voltage
78		drops below 1V.
79
80		Access: Read, Write
81
82		Valid values: 0 (disable) or 1 (enable)
83