xref: /linux/Documentation/ABI/testing/sysfs-bus-iio-chemical-sgp40 (revision 3a39d672e7f48b8d6b91a09afa4b55352773b4b5)
1*1081b9d9SAndreas KlingerWhat:		/sys/bus/iio/devices/iio:deviceX/out_temp_raw
2*1081b9d9SAndreas KlingerDate:		August 2021
3*1081b9d9SAndreas KlingerKernelVersion:	5.15
4*1081b9d9SAndreas KlingerContact:	Andreas Klinger <ak@it-klinger.de>
5*1081b9d9SAndreas KlingerDescription:
6*1081b9d9SAndreas Klinger		Set the temperature. This value is sent to the sensor for
7*1081b9d9SAndreas Klinger		temperature compensation.
8*1081b9d9SAndreas Klinger		Default value: 25000 (25 °C)
9*1081b9d9SAndreas Klinger
10*1081b9d9SAndreas KlingerWhat:		/sys/bus/iio/devices/iio:deviceX/out_humidityrelative_raw
11*1081b9d9SAndreas KlingerDate:		August 2021
12*1081b9d9SAndreas KlingerKernelVersion:	5.15
13*1081b9d9SAndreas KlingerContact:	Andreas Klinger <ak@it-klinger.de>
14*1081b9d9SAndreas KlingerDescription:
15*1081b9d9SAndreas Klinger		Set the relative humidity. This value is sent to the sensor for
16*1081b9d9SAndreas Klinger		humidity compensation.
17*1081b9d9SAndreas Klinger		Default value: 50000 (50 % relative humidity)