Searched refs:draining (Results 1 – 15 of 15) sorted by relevance
| /linux/drivers/md/dm-vdo/ |
| H A D | admin-state.c | 79 .draining = true, 85 .draining = true, 91 .draining = true, 103 .draining = true, 110 .draining = true, 116 .draining = true, 128 .draining = true, 319 return check_code(operation->draining, operation, "drain operation", waiter); in assert_vdo_drain_operation()
|
| H A D | admin-state.h | 17 bool draining; member 109 return vdo_get_admin_state_code(state)->draining; in vdo_is_state_draining()
|
| /linux/tools/perf/util/ |
| H A D | sideband_evlist.c | 38 bool draining = false; in perf_evlist__poll_thread() local 53 draining = true; in perf_evlist__poll_thread() 55 if (!draining) in perf_evlist__poll_thread() 78 if (draining && !got_data) in perf_evlist__poll_thread()
|
| /linux/drivers/staging/vc04_services/bcm2835-audio/ |
| H A D | bcm2835-pcm.c | 64 alsa_stream->draining ? in bcm2835_playback_fifo() 228 alsa_stream->draining = false; in snd_bcm2835_pcm_prepare() 264 alsa_stream->draining = true; in snd_bcm2835_pcm_trigger()
|
| H A D | vc_vchi_audioserv_defs.h | 58 u32 draining; member
|
| H A D | bcm2835.h | 74 int draining; member
|
| H A D | bcm2835-vchiq.c | 311 .stop.draining = 1, in bcm2835_audio_drain()
|
| /linux/drivers/net/ethernet/qlogic/qed/ |
| H A D | qed_roce.c | 832 out_params->draining = false; in qed_roce_query_qp() 885 out_params->draining = false; in qed_roce_query_qp() 931 out_params->draining = false; in qed_roce_query_qp() 936 out_params->draining = true; in qed_roce_query_qp()
|
| /linux/include/linux/qed/ |
| H A D | qed_rdma_if.h | 394 bool draining; member
|
| /linux/Documentation/process/ |
| H A D | researcher-guidelines.rst | 78 to. Such communication can be damaging to the developer (e.g. draining
|
| /linux/tools/perf/ |
| H A D | builtin-record.c | 2436 bool disabled = false, draining = false; in __cmd_record() local 2739 if (trigger_is_hit(&switch_output_trigger) || done || draining) in __cmd_record() 2799 if (done || draining) in __cmd_record() 2812 draining = true; in __cmd_record()
|
| H A D | builtin-trace.c | 4382 bool draining = false; in trace__run() local 4588 if (done && !draining) { in trace__run() 4590 draining = true; in trace__run() 4599 if (!draining && evlist__poll(evlist, timeout) > 0) { in trace__run() 4601 draining = true; in trace__run()
|
| /linux/Documentation/scheduler/ |
| H A D | sched-util-clamp.rst | 586 limit it from draining system power at the cost of reduced performance for
|
| /linux/drivers/scsi/aic7xxx/ |
| H A D | aic79xx.seq | 150 * still be data in our FIFOs draining to the host. Complete 174 * 1) Configured and draining to the host, with a FIFO handler.
|
| /linux/arch/arm/ |
| H A D | Kconfig | 706 r2p0) erratum. The Store Buffer does not have any automatic draining
|