Home
last modified time | relevance | path

Searched refs:NS2 (Results 1 – 15 of 15) sorted by relevance

/linux/tools/testing/selftests/bpf/
H A Dtest_lwt_ip_encap.sh
H A Dtest_xdp_vlan.sh
H A Dtest_lwt_seg6local.sh
/linux/tools/testing/selftests/net/
H A Dmsg_zerocopy.sh16 readonly NS2="${NSPREFIX}2"
87 ip netns del "${NS2}"
95 ip netns add "${NS2}"
99 ip netns exec "${NS2}" sysctl -w -q "${path_sysctl_mem}=1000000"
102 peer name "${DEV}" mtu "${DEV_MTU}" netns "${NS2}"
104 ip link add "${DUMMY_DEV}" mtu "${DEV_MTU}" netns "${NS2}" type dummy
108 ip -netns "${NS2}" link set "${DEV}" up
109 ip -netns "${NS2}" link set "${DUMMY_DEV}" up
113 ip -netns "${NS2}" link set dev "${DEV}" address 06:06:06:06:06:06
117 ip -netns "${NS2}" addr add "${DADDR}/${MASK}" dev "${DEV}" ${NODAD}
[all …]
H A Dio_uring_zerocopy_tx.sh16 readonly NS2="${NSPREFIX}2"
81 ip netns del "${NS2}"
89 ip netns add "${NS2}"
93 ip netns exec "${NS2}" sysctl -w -q "${path_sysctl_mem}=1000000"
96 peer name "${DEV}" mtu "${DEV_MTU}" netns "${NS2}"
100 ip -netns "${NS2}" link set "${DEV}" up
104 ip -netns "${NS2}" link set dev "${DEV}" address 06:06:06:06:06:06
108 ip -netns "${NS2}" addr add 192.168.1.2/24 dev "${DEV}"
110 ip -netns "${NS2}" addr add fd::2/64 dev "${DEV}" nodad
119 ip netns exec "${NS2}" "${BIN_RX}" "-${IP}" -t 2 -C 2 -S "${SADDR}" -D "${DADDR}" -r "${RXMODE}" &
H A Dbareudp.sh133 setup_ns NS0 NS1 NS2 NS3 || exit_cleanup
172 ip link add name veth12 netns "${NS1}" type veth peer name veth21 netns "${NS2}"
173 ip link add name veth23 netns "${NS2}" type veth peer name veth32 netns "${NS3}"
177 iface_config "${NS2}" veth21 192.0.2.22 192.0.2.21/32 2001:db8::22 2001:db8::21/128
178 iface_config "${NS2}" veth23 192.0.2.32 192.0.2.33/32 2001:db8::32 2001:db8::33/128
182 tc -netns "${NS2}" qdisc add dev veth23 ingress
210 ip netns exec "${NS2}" sysctl -qw net.ipv4.ip_forward=1
212 ip -netns "${NS2}" route add 192.0.2.103/32 via 192.0.2.33
226 ip netns exec "${NS2}" sysctl -qw net.ipv6.conf.all.forwarding=1
228 ip -netns "${NS2}" route add 2001:db8::103/128 via 2001:db8::33
[all …]
H A Dso_txtime.sh15 readonly NS2="${NSPREFIX}2"
23 ip netns del "${NS2}"
31 ip netns add "${NS2}"
34 peer name "${DEV}" netns "${NS2}"
38 ip -netns "${NS2}" link set "${DEV}" up
42 ip -netns "${NS2}" link set dev "${DEV}" address 06:06:06:06:06:06
46 ip -netns "${NS2}" addr add 192.168.1.2/24 dev "${DEV}"
48 ip -netns "${NS2}" addr add fd::2/64 dev "${DEV}" nodad
69 …ip netns exec "${NS2}" "${BIN}" -"${IP}" -c "${CLOCK}" -t "${START}" -S "${SADDR}" -D "${DADDR}" "…
H A Dicmp.sh35 cleanup_ns $NS1 $NS2
41 setup_ns NS1 NS2
44 ip -netns $NS1 link add veth0 type veth peer name veth0 netns $NS2
46 ip -netns $NS2 link set dev veth0 up
49 ip -netns $NS2 addr add $H2_IP6/64 dev veth0 nodad
51 ip -netns $NS2 route add $RT2 via inet6 $H1_IP6
54 ip netns exec $NS2 sysctl -qw net.ipv4.icmp_ratelimit=0 net.ipv4.ip_forward=1
/linux/tools/testing/selftests/bpf/prog_tests/
H A Dxfrm_info.c56 #define NS2 "xfrm_test_ns2" macro
109 SYS_NOFAIL("test -f /var/run/netns/" NS2 " && ip netns delete " NS2); in cleanup()
116 SYS(fail, "ip netns add " NS2); in config_underlay()
126 SYS(fail, "ip link add veth02 netns " NS0 " type veth peer name veth20 netns " NS2); in config_underlay()
129 SYS(fail, "ip -net " NS2 " addr add " IP4_ADDR_VETH20 "/24 dev veth20"); in config_underlay()
130 SYS(fail, "ip -net " NS2 " link set dev veth20 up"); in config_underlay()
254 if (setup_xfrm_tunnel(NS0, NS2, IP4_ADDR_VETH02, IP4_ADDR_VETH20, in config_overlay()
269 SYS(fail, "ip -net " NS2 " link add ipsec0 type xfrm if_id %d", IF_ID_2); in config_overlay()
270 SYS(fail, "ip -net " NS2 " addr add 192.168.1.200/24 dev ipsec0"); in config_overlay()
271 SYS(fail, "ip -net " NS2 " link set dev ipsec0 up"); in config_overlay()
[all …]
H A Dxdp_do_redirect.c263 #define NS2 "NS2" macro
/linux/samples/bpf/
H A Dtest_lwt_bpf.sh8 NS2=lwt_ns2
49 ip netns delete $NS2 2> /dev/null
370 setup_one_veth $NS2 $VETH2 $VETH3 $IPVETH2 $IPVETH3
/linux/Documentation/devicetree/bindings/usb/
H A Diproc-udc.txt10 For Broadcom NS2 platform, add "brcm,ns2-udc","brcm,iproc-udc".
/linux/drivers/block/drbd/
H A Ddrbd_state.h40 #define NS2(T1, S1, T2, S2) \ macro
H A Ddrbd_nl.c2680 rv = conn_request_state(connection, NS2(conn, C_DISCONNECTING, pdsk, D_OUTDATED), 0); in conn_try_disconnect()
2693 rv = conn_request_state(connection, NS2(conn, C_DISCONNECTING, in conn_try_disconnect()
H A Ddrbd_receiver.c4377 conn_request_state(peer_device->connection, NS2(conn, C_PROTOCOL_ERROR, susp, 0), CS_HARD); in receive_state()