/freebsd/share/man/man4/ |
H A D | ure.4 | 82 .Cm full-duplex 84 .Cm half-duplex 91 .Cm full-duplex 93 .Cm half-duplex 98 .Cm full-duplex 103 .Cm full-duplex 110 .Bl -tag -width "full-duplex" 111 .It Cm full-duplex 112 Force full-duplex operation. 113 .It Cm half-duplex [all …]
|
H A D | nge.4 | 68 full or half duplex. 93 .Cm full-duplex 95 .Cm half-duplex 103 .Cm full-duplex 105 .Cm half-duplex 109 .Cm full-duplex 111 .Cm half-duplex 116 .Cm full-duplex 118 .Cm half-duplex 125 .Bl -tag -width full-duplex [all …]
|
H A D | genet.4 | 53 10/100/1000Mbps operation in full-duplex mode 55 10/100Mbps operation in half-duplex mode 77 .Cm full-duplex 79 .Cm half-duplex 87 .Cm full-duplex 89 .Cm half-duplex 94 .Cm full-duplex 105 .Bl -tag -width ".Cm full-duplex" 106 .It Cm full-duplex 107 Force full duplex operation. [all …]
|
H A D | axge.4 | 86 .Cm full-duplex 88 .Cm half-duplex 96 .Cm full-duplex 98 .Cm half-duplex 106 .Cm full-duplex 108 .Cm half-duplex 115 .Bl -tag -width ".Cm full-duplex" 116 .It Cm full-duplex 117 Force full duplex operation. 118 .It Cm half-duplex [all …]
|
H A D | msk.4 | 83 .Cm full-duplex 85 .Cm half-duplex 93 .Cm full-duplex 95 .Cm half-duplex 103 .Cm full-duplex 105 .Cm half-duplex 110 .Cm full-duplex 112 .Cm half-duplex 119 .Bl -tag -width ".Cm full-duplex" 120 .It Cm full-duplex [all …]
|
H A D | stge.4 | 92 .Cm full-duplex 94 .Cm half-duplex 102 .Cm full-duplex 104 .Cm half-duplex 114 .\" .Cm full-duplex 116 .\" .Cm half-duplex 123 .Bl -tag -width ".Cm full-duplex" 124 .It Cm full-duplex 125 Force full duplex operation. 126 .It Cm half-duplex [all …]
|
H A D | et.4 | 81 .Ar full-duplex 83 .Ar half-duplex 91 .Ar full-duplex 93 .Ar half-duplex 101 .Ar full-duplex 111 .Bl -tag -width full-duplex -compact 112 .It full-duplex 113 Force full-duplex operation. 115 .It half-duplex 116 Force half-duplex operation.
|
H A D | axe.4 | 97 .Cm full-duplex 99 .Cm half-duplex 107 .Cm full-duplex 109 .Cm half-duplex 117 .Cm full-duplex 119 .Cm half-duplex 126 .Bl -tag -width ".Cm full-duplex" 127 .It Cm full-duplex 128 Force full duplex operation. 129 .It Cm half-duplex [all …]
|
H A D | rue.4 | 58 both 10 and 100Mbps speeds in either full or half duplex. 80 .Cm full-duplex 82 .Cm half-duplex 89 .Cm full-duplex 91 .Cm half-duplex 99 .It Cm full-duplex 100 Force full duplex operation. 101 .It Cm half-duplex 102 Force half duplex operation.
|
H A D | aue.4 | 63 will operate at 100Base-TX and full-duplex. 94 .Ar full-duplex 97 .Ar full duplex 99 .Ar half-duplex 106 .Ar full-duplex 109 .Ar full duplex 111 .Ar half-duplex 119 .It full-duplex 120 Force full duplex operation. 122 half duplex mode if this media option is not specified.
|
H A D | bge.4 | 81 full or half duplex. 107 .Cm full-duplex 109 .Cm half-duplex 117 .Cm full-duplex 119 .Cm half-duplex 124 .Cm full-duplex 129 .Cm full-duplex 131 .Cm half-duplex 138 .Bl -tag -width ".Cm full-duplex" 139 .It Cm full-duplex [all …]
|
H A D | vge.4 | 105 .Cm full-duplex 107 .Cm half-duplex 115 .Cm full-duplex 117 .Cm half-duplex 125 .Cm full-duplex 127 .Cm half-duplex 134 .Bl -tag -width ".Cm full-duplex" 135 .It Cm full-duplex 136 Force full duplex operation. 137 .It Cm half-duplex [all …]
|
H A D | re.4 | 102 .Cm full-duplex 104 .Cm half-duplex 112 .Cm full-duplex 114 .Cm half-duplex 119 .Cm full-duplex 124 .\" .Cm full-duplex 126 .\" .Cm half-duplex 133 .Bl -tag -width ".Cm full-duplex" 134 .It Cm full-duplex 135 Force full duplex operation. [all …]
|
H A D | em.4 | 116 Enables auto-negotiation for speed and duplex. 122 .Cm full-duplex 129 .Cm full-duplex 134 .Cm full-duplex 139 .Cm full-duplex 146 .Bl -tag -width ".Cm full-duplex" 147 .It Cm full-duplex 148 Forces full-duplex operation 149 .It Cm half-duplex 150 Forces half-duplex operation. [all …]
|
H A D | ste.4 | 66 It supports both 10 and 100Mbps speeds in either full or half duplex 84 .Ar full-duplex 86 .Ar half-duplex 93 .Ar full-duplex 95 .Ar half-duplex 103 .It full-duplex 104 Force full duplex operation. 105 .It half-duplex 106 Force half duplex operation.
|
H A D | vr.4 | 73 10 and 100Mbps speeds in either full or half duplex. 90 .Ar full-duplex 92 .Ar half-duplex 99 .Ar full-duplex 101 .Ar half-duplex 109 .It full-duplex 110 Force full duplex operation. 111 .It half-duplex 112 Force half duplex operation.
|
H A D | dc.4 | 64 media attachments, 10 and 100Mbps speeds in full or half duplex, 114 .Cm full-duplex 117 .Cm full-duplex 119 .Cm half-duplex 126 .Cm full-duplex 129 .Cm full-duplex 131 .Cm half-duplex 138 .Bl -tag -width ".Cm full-duplex" 139 .It Cm full-duplex 140 Force full duplex operation. [all …]
|
H A D | sis.4 | 93 .Sq full-duplex 95 .Sq half-duplex 103 .Sq full-duplex 105 .Sq half-duplex 112 .Bl -tag -width full-duplex 113 .It full-duplex 114 Force full duplex operation. 115 .It half-duplex 116 Force half duplex operation.
|
H A D | sk.4 | 85 The XaQti XMAC II supports full and half duplex operation with 110 .Ar full-duplex 112 .Ar half-duplex 117 .Ar full-duplex 119 .Ar half-duplex 127 .It full-duplex 128 Force full duplex operation. 129 .It half-duplex 130 Force half duplex operation.
|
H A D | xl.4 | 63 NS 83840A 10/100 PHY for 10/100 Mbps support in full or half-duplex. 68 100Mbps data rates in either full or half duplex and can be manually 92 .Ar full-duplex 94 .Ar half-duplex 101 .Ar full-duplex 103 .Ar half-duplex 115 .It full-duplex 116 Force full duplex operation. 117 .It half-duplex 118 Force half duplex operation.
|
H A D | bce.4 | 72 10/100/1000Mbps operation in full-duplex mode 74 10/100Mbps operation in half-duplex mode 92 .Cm full-duplex 94 .Cm half-duplex 102 .Cm full-duplex 104 .Cm half-duplex 109 .Cm full-duplex 114 .Cm full-duplex 119 .Cm full-duplex 126 .Bl -tag -width ".Cm full-duplex" [all …]
|
H A D | lge.4 | 85 .Cm full-duplex 87 .Cm half-duplex 94 .Bl -tag -width ".Cm full-duplex" 95 .It Cm full-duplex 96 Force full duplex operation. 97 .It Cm half-duplex 98 Force half duplex operation.
|
/freebsd/sys/dev/e1000/ |
H A D | README | 106 Speed and Duplex Configuration 108 In addressing speed and duplex configuration issues, you need to distinguish 118 duplex mode. Your link partner must match the setting you choose. 1 Gbps speeds 122 Caution: Only experienced network administrators should force speed and duplex 130 operate only in full duplex and only at their native speed. 132 By default, the adapter auto-negotiates the speed and duplex of the connection. 134 speed and duplex settings on the adapter. 138 # ifconfig emX <IP_address> media 100baseTX mediaopt full-duplex 140 NOTE: Only use mediaopt to set the driver to full-duplex. If mediaopt is not 142 half-duplex. [all …]
|
/freebsd/sys/dev/mii/ |
H A D | rgephyreg.h | 55 #define RGEPHY_BMCR_FDX 0x0100 /* Duplex mode */ 65 #define RGEPHY_BMSR_100TXFDX 0x4000 /* 100 base Tx full duplex capable */ 66 #define RGEPHY_BMSR_100TXHDX 0x2000 /* 100 base Tx half duplex capable */ 67 #define RGEPHY_BMSR_10TFDX 0x1000 /* 10 base T full duplex capable */ 68 #define RGEPHY_BMSR_10THDX 0x0800 /* 10 base T half duplex capable */ 69 #define RGEPHY_BMSR_100T2FDX 0x0400 /* 100 base T2 full duplex capable */ 70 #define RGEPHY_BMSR_100T2HDX 0x0200 /* 100 base T2 half duplex capable */ 122 #define RGEPHY_1000CTL_AFD 0x0200 /* Advertise full duplex */ 123 #define RGEPHY_1000CTL_AHD 0x0100 /* Advertise half duplex */ 162 #define RGEPHY_SSR_FDX 0x2000 /* full duplex */ [all …]
|
/freebsd/sys/dev/igc/ |
H A D | igc_phy.c | 341 /* Do we want to advertise 10 Mb Half Duplex? */ in igc_phy_setup_autoneg() 343 DEBUGOUT("Advertise 10mb Half duplex\n"); in igc_phy_setup_autoneg() 347 /* Do we want to advertise 10 Mb Full Duplex? */ in igc_phy_setup_autoneg() 349 DEBUGOUT("Advertise 10mb Full duplex\n"); in igc_phy_setup_autoneg() 353 /* Do we want to advertise 100 Mb Half Duplex? */ in igc_phy_setup_autoneg() 355 DEBUGOUT("Advertise 100mb Half duplex\n"); in igc_phy_setup_autoneg() 359 /* Do we want to advertise 100 Mb Full Duplex? */ in igc_phy_setup_autoneg() 361 DEBUGOUT("Advertise 100mb Full duplex\n"); in igc_phy_setup_autoneg() 365 /* We do not allow the Phy to advertise 1000 Mb Half Duplex */ in igc_phy_setup_autoneg() 367 DEBUGOUT("Advertise 1000mb Half duplex request denied!\n"); in igc_phy_setup_autoneg() [all …]
|