Lines Matching +full:timeout +full:- +full:secs

1 // SPDX-License-Identifier: GPL-2.0+
25 * Watchdog selector to timeout in seconds.
27 * others: timeout = 2048 ms * 2^(TWDSCALE-1).
33 #define DA9063_TWDSCALE_MAX (ARRAY_SIZE(wdt_timeout) - 1)
39 static unsigned int da9063_wdt_timeout_to_sel(unsigned int secs) in da9063_wdt_timeout_to_sel() argument
44 if (wdt_timeout[i] >= secs) in da9063_wdt_timeout_to_sel()
52 * Read the currently active timeout.
59 regmap_read(da9063->regmap, DA9063_REG_CONTROL_D, &val); in da9063_wdt_read_timeout()
66 return regmap_update_bits(da9063->regmap, DA9063_REG_CONTROL_D, in da9063_wdt_disable_timer()
72 da9063_wdt_update_timeout(struct da9063 *da9063, unsigned int timeout) in da9063_wdt_update_timeout() argument
78 * The watchdog triggers a reboot if a timeout value is already in da9063_wdt_update_timeout()
79 * programmed because the timeout value combines two functions in da9063_wdt_update_timeout()
81 * The watchdog must be disabled to be able to change the timeout in da9063_wdt_update_timeout()
83 * new timeout value which enables the watchdog again. in da9063_wdt_update_timeout()
90 regval = da9063_wdt_timeout_to_sel(timeout); in da9063_wdt_update_timeout()
92 return regmap_update_bits(da9063->regmap, DA9063_REG_CONTROL_D, in da9063_wdt_update_timeout()
101 ret = da9063_wdt_update_timeout(da9063, wdd->timeout); in da9063_wdt_start()
103 dev_err(da9063->dev, "Watchdog failed to start (err = %d)\n", in da9063_wdt_start()
116 dev_alert(da9063->dev, "Watchdog failed to stop (err = %d)\n", in da9063_wdt_stop()
134 ret = regmap_write(da9063->regmap, DA9063_REG_CONTROL_F, in da9063_wdt_ping()
137 dev_alert(da9063->dev, "Failed to ping the watchdog (err = %d)\n", in da9063_wdt_ping()
144 unsigned int timeout) in da9063_wdt_set_timeout() argument
151 * 1. The watchdog is off and someone wants to set the timeout for the in da9063_wdt_set_timeout()
153 * 2. The watchdog is already running and a new timeout value should be in da9063_wdt_set_timeout()
156 * The watchdog can't store a timeout value not equal zero without in da9063_wdt_set_timeout()
157 * enabling the watchdog, so the timeout must be buffered by the driver. in da9063_wdt_set_timeout()
160 ret = da9063_wdt_update_timeout(da9063, timeout); in da9063_wdt_set_timeout()
163 dev_err(da9063->dev, "Failed to set watchdog timeout (err = %d)\n", in da9063_wdt_set_timeout()
166 wdd->timeout = wdt_timeout[da9063_wdt_timeout_to_sel(timeout)]; in da9063_wdt_set_timeout()
175 struct i2c_client *client = to_i2c_client(da9063->dev); in da9063_wdt_restart()
186 ret = __i2c_smbus_xfer(client->adapter, client->addr, client->flags, in da9063_wdt_restart()
191 dev_alert(da9063->dev, "Failed to shutdown (err = %d)\n", in da9063_wdt_restart()
216 struct device *dev = &pdev->dev; in da9063_wdt_probe()
219 unsigned int timeout; in da9063_wdt_probe() local
221 if (!dev->parent) in da9063_wdt_probe()
222 return -EINVAL; in da9063_wdt_probe()
224 da9063 = dev_get_drvdata(dev->parent); in da9063_wdt_probe()
226 return -EINVAL; in da9063_wdt_probe()
230 return -ENOMEM; in da9063_wdt_probe()
232 da9063->use_sw_pm = device_property_present(dev, "dlg,use-sw-pm"); in da9063_wdt_probe()
234 wdd->info = &da9063_watchdog_info; in da9063_wdt_probe()
235 wdd->ops = &da9063_watchdog_ops; in da9063_wdt_probe()
236 wdd->min_timeout = DA9063_WDT_MIN_TIMEOUT; in da9063_wdt_probe()
237 wdd->max_timeout = DA9063_WDT_MAX_TIMEOUT; in da9063_wdt_probe()
238 wdd->min_hw_heartbeat_ms = DA9063_RESET_PROTECTION_MS; in da9063_wdt_probe()
239 wdd->parent = dev; in da9063_wdt_probe()
240 wdd->status = WATCHDOG_NOWAYOUT_INIT_STATUS; in da9063_wdt_probe()
246 wdd->timeout = DA9063_WDG_TIMEOUT; in da9063_wdt_probe()
248 /* Use pre-configured timeout if watchdog is already running. */ in da9063_wdt_probe()
249 timeout = da9063_wdt_read_timeout(da9063); in da9063_wdt_probe()
250 if (timeout) in da9063_wdt_probe()
251 wdd->timeout = timeout; in da9063_wdt_probe()
253 /* Set timeout, maybe override it with DT value, scale it */ in da9063_wdt_probe()
255 da9063_wdt_set_timeout(wdd, wdd->timeout); in da9063_wdt_probe()
257 /* Update timeout if the watchdog is already running. */ in da9063_wdt_probe()
258 if (timeout) { in da9063_wdt_probe()
259 da9063_wdt_update_timeout(da9063, wdd->timeout); in da9063_wdt_probe()
260 set_bit(WDOG_HW_RUNNING, &wdd->status); in da9063_wdt_probe()
271 if (!da9063->use_sw_pm) in da9063_wdt_suspend()
285 if (!da9063->use_sw_pm) in da9063_wdt_resume()