Lines Matching +full:precharge +full:- +full:upper +full:- +full:limit +full:- +full:microvolt

1 // SPDX-License-Identifier: GPL-2.0-only
19 #include <linux/extcon-provider.h>
32 #define BQ24190_REG_POC 0x01 /* Power-On Configuration */
63 #define BQ24190_REG_PCTCC 0x03 /* Pre-charge/Termination Current Cntl */
162 * The tables below provide a 2-way mapping for the value that goes in
163 * the register field and the real-world value that it represents.
165 * number at that index in the array is the real-world value that it
272 * 'val'. The index range returned is 0 to 'tbl_size' - 1. Assumes that
284 return i - 1; in bq24190_find_idx()
293 ret = i2c_smbus_read_byte_data(bdi->client, reg); in bq24190_read()
303 return i2c_smbus_write_byte_data(bdi->client, reg, data); in bq24190_write()
351 v = (v >= tbl_size) ? (tbl_size - 1) : v; in bq24190_get_field_val()
405 /* On i386 ptrace-abi.h defines SS that breaks the macro calls below. */
460 int i, limit = ARRAY_SIZE(bq24190_sysfs_field_tbl); in bq24190_sysfs_init_attrs() local
462 for (i = 0; i < limit; i++) in bq24190_sysfs_init_attrs()
465 bq24190_sysfs_attrs[limit] = NULL; /* Has additional entry for this */ in bq24190_sysfs_init_attrs()
471 int i, limit = ARRAY_SIZE(bq24190_sysfs_field_tbl); in bq24190_sysfs_field_lookup() local
473 for (i = 0; i < limit; i++) in bq24190_sysfs_field_lookup()
477 if (i >= limit) in bq24190_sysfs_field_lookup()
493 info = bq24190_sysfs_field_lookup(attr->attr.name); in bq24190_sysfs_show()
495 return -EINVAL; in bq24190_sysfs_show()
497 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_sysfs_show()
501 ret = bq24190_read_mask(bdi, info->reg, info->mask, info->shift, &v); in bq24190_sysfs_show()
507 pm_runtime_put_autosuspend(bdi->dev); in bq24190_sysfs_show()
521 info = bq24190_sysfs_field_lookup(attr->attr.name); in bq24190_sysfs_store()
523 return -EINVAL; in bq24190_sysfs_store()
529 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_sysfs_store()
533 ret = bq24190_write_mask(bdi, info->reg, info->mask, info->shift, v); in bq24190_sysfs_store()
537 pm_runtime_put_autosuspend(bdi->dev); in bq24190_sysfs_store()
545 union power_supply_propval val = { .intval = bdi->charge_type }; in bq24190_set_otg_vbus()
548 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_set_otg_vbus()
550 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", ret); in bq24190_set_otg_vbus()
554 bdi->otg_vbus_enabled = enable; in bq24190_set_otg_vbus()
563 pm_runtime_put_autosuspend(bdi->dev); in bq24190_set_otg_vbus()
570 union power_supply_propval val = { .intval = bdi->charge_type }; in bq24296_set_otg_vbus()
573 ret = pm_runtime_resume_and_get(bdi->dev); in bq24296_set_otg_vbus()
575 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", ret); in bq24296_set_otg_vbus()
579 bdi->otg_vbus_enabled = enable; in bq24296_set_otg_vbus()
605 pm_runtime_put_autosuspend(bdi->dev); in bq24296_set_otg_vbus()
627 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_vbus_is_enabled()
629 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", ret); in bq24190_vbus_is_enabled()
637 pm_runtime_put_autosuspend(bdi->dev); in bq24190_vbus_is_enabled()
642 bdi->otg_vbus_enabled = (val == BQ24190_REG_POC_CHG_CONFIG_OTG || in bq24190_vbus_is_enabled()
644 return bdi->otg_vbus_enabled; in bq24190_vbus_is_enabled()
663 ret = pm_runtime_resume_and_get(bdi->dev); in bq24296_vbus_is_enabled()
665 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", ret); in bq24296_vbus_is_enabled()
673 pm_runtime_put_autosuspend(bdi->dev); in bq24296_vbus_is_enabled()
678 bdi->otg_vbus_enabled = (val == BQ24296_REG_POC_OTG_CONFIG_OTG); in bq24296_vbus_is_enabled()
680 return bdi->otg_vbus_enabled; in bq24296_vbus_is_enabled()
691 .of_match = "usb-otg-vbus",
707 .of_match = "usb-otg-vbus",
723 struct bq24190_platform_data *pdata = bdi->dev->platform_data; in bq24190_register_vbus_regulator()
728 cfg.dev = bdi->dev; in bq24190_register_vbus_regulator()
729 if (pdata && pdata->regulator_init_data) in bq24190_register_vbus_regulator()
730 cfg.init_data = pdata->regulator_init_data; in bq24190_register_vbus_regulator()
734 reg = devm_regulator_register(bdi->dev, bdi->info->vbus_desc, &cfg); in bq24190_register_vbus_regulator()
737 dev_err(bdi->dev, "Can't register regulator: %d\n", ret); in bq24190_register_vbus_regulator()
758 bdi->watchdog = ((v & BQ24190_REG_CTTC_WATCHDOG_MASK) >> in bq24190_set_config()
775 if (bdi->sys_min) { in bq24190_set_config()
776 v = bdi->sys_min / 100 - 30; // manual section 9.5.1.2, table 9 in bq24190_set_config()
785 if (bdi->iprechg) { in bq24190_set_config()
786 v = bdi->iprechg / 128 - 1; // manual section 9.5.1.4, table 11 in bq24190_set_config()
795 if (bdi->iterm) { in bq24190_set_config()
796 v = bdi->iterm / 128 - 1; // manual section 9.5.1.4, table 11 in bq24190_set_config()
805 if (bdi->ichg) { in bq24190_set_config()
810 bdi->info->ichg_array_size, in bq24190_set_config()
811 bdi->ichg); in bq24190_set_config()
816 if (bdi->vreg) { in bq24190_set_config()
822 bdi->vreg); in bq24190_set_config()
832 int ret, limit = 100; in bq24190_register_reset() local
838 * { PROPERTY_ENTRY_BOOL("disable-reset"), ... }; in bq24190_register_reset()
845 if (device_property_read_bool(bdi->dev, "disable-reset")) in bq24190_register_reset()
869 } while (--limit); in bq24190_register_reset()
871 return -EIO; in bq24190_register_reset()
904 val->intval = type; in bq24190_charger_get_charge_type()
943 switch (val->intval) { in bq24190_charger_set_charge_type()
958 return -EINVAL; in bq24190_charger_set_charge_type()
961 bdi->charge_type = val->intval; in bq24190_charger_set_charge_type()
964 * the charge-type until its gets disabled. in bq24190_charger_set_charge_type()
966 if (bdi->otg_vbus_enabled) in bq24190_charger_set_charge_type()
985 return bdi->info->set_chg_config(bdi, chg_config); in bq24190_charger_set_charge_type()
1037 mutex_lock(&bdi->f_reg_lock); in bq24190_charger_get_health()
1038 v = bdi->f_reg; in bq24190_charger_get_health()
1039 mutex_unlock(&bdi->f_reg_lock); in bq24190_charger_get_health()
1041 if (v & bdi->info->ntc_fault_mask) { in bq24190_charger_get_health()
1042 health = bdi->info->get_ntc_status(v); in bq24190_charger_get_health()
1049 * This could be over-voltage or under-voltage in bq24190_charger_get_health()
1052 * when its really under-voltage, just return in bq24190_charger_get_health()
1064 health = -1; in bq24190_charger_get_health()
1068 * This could be over-current or over-voltage but there's in bq24190_charger_get_health()
1071 * even if it was over-current. in bq24190_charger_get_health()
1078 val->intval = health; in bq24190_charger_get_health()
1101 val->intval = pg_stat && !batfet_disable; in bq24190_charger_get_online()
1163 val->intval = curr; in bq24190_charger_get_precharge()
1180 val->intval = ++v * 128 * 1000; in bq24190_charger_get_charge_term()
1193 bdi->info->ichg_array_size, &curr); in bq24190_charger_get_current()
1207 val->intval = curr; in bq24190_charger_get_current()
1215 int ret, curr = val->intval; in bq24190_charger_set_current()
1227 if (curr > bdi->ichg_max) in bq24190_charger_set_current()
1228 return -EINVAL; in bq24190_charger_set_current()
1233 bdi->info->ichg_array_size, curr); in bq24190_charger_set_current()
1237 bdi->ichg = curr; in bq24190_charger_set_current()
1254 val->intval = voltage; in bq24190_charger_get_voltage()
1263 if (val->intval > bdi->vreg_max) in bq24190_charger_set_voltage()
1264 return -EINVAL; in bq24190_charger_set_voltage()
1269 ARRAY_SIZE(bq24190_cvc_vreg_values), val->intval); in bq24190_charger_set_voltage()
1273 bdi->vreg = val->intval; in bq24190_charger_set_voltage()
1291 val->intval = iinlimit; in bq24190_charger_get_iinlimit()
1302 ARRAY_SIZE(bq24190_isc_iinlim_values), val->intval); in bq24190_charger_set_iinlimit()
1311 dev_dbg(bdi->dev, "prop: %d\n", psp); in bq24190_charger_get_property()
1313 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_charger_get_property()
1344 val->intval = bdi->ichg_max; in bq24190_charger_get_property()
1351 val->intval = bdi->vreg_max; in bq24190_charger_get_property()
1358 val->intval = POWER_SUPPLY_SCOPE_SYSTEM; in bq24190_charger_get_property()
1362 val->strval = bdi->model_name; in bq24190_charger_get_property()
1366 val->strval = BQ24190_MANUFACTURER; in bq24190_charger_get_property()
1370 ret = -ENODATA; in bq24190_charger_get_property()
1373 pm_runtime_put_autosuspend(bdi->dev); in bq24190_charger_get_property()
1385 dev_dbg(bdi->dev, "prop: %d\n", psp); in bq24190_charger_set_property()
1387 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_charger_set_property()
1412 ret = -EINVAL; in bq24190_charger_set_property()
1415 pm_runtime_put_autosuspend(bdi->dev); in bq24190_charger_set_property()
1445 ret = power_supply_get_property_from_supplier(bdi->charger, in bq24190_input_current_limit_work()
1451 bq24190_charger_set_property(bdi->charger, in bq24190_input_current_limit_work()
1454 power_supply_changed(bdi->charger); in bq24190_input_current_limit_work()
1457 /* Sync the input-current-limit with our parent supply (if we have one) */
1463 * The Power-Good detection may take up to 220ms, sometimes in bq24190_charger_external_power_changed()
1467 * too low default 500mA iinlim. Delay setting the input-current-limit in bq24190_charger_external_power_changed()
1470 queue_delayed_work(system_wq, &bdi->input_current_limit_work, in bq24190_charger_external_power_changed()
1494 "main-battery",
1498 .name = "bq24190-charger",
1519 mutex_lock(&bdi->f_reg_lock); in bq24190_battery_get_status()
1520 chrg_fault = bdi->f_reg; in bq24190_battery_get_status()
1521 mutex_unlock(&bdi->f_reg_lock); in bq24190_battery_get_status()
1532 * - there is no good power source; in bq24190_battery_get_status()
1533 * - there is a charge fault. in bq24190_battery_get_status()
1547 case 0x1: /* Pre-charge */ in bq24190_battery_get_status()
1555 ret = -EIO; in bq24190_battery_get_status()
1560 val->intval = status; in bq24190_battery_get_status()
1571 mutex_lock(&bdi->f_reg_lock); in bq24190_battery_get_health()
1572 v = bdi->f_reg; in bq24190_battery_get_health()
1573 mutex_unlock(&bdi->f_reg_lock); in bq24190_battery_get_health()
1578 v &= bdi->info->ntc_fault_mask; in bq24190_battery_get_health()
1580 health = v ? bdi->info->get_ntc_status(v) : POWER_SUPPLY_HEALTH_GOOD; in bq24190_battery_get_health()
1583 val->intval = health; in bq24190_battery_get_health()
1599 val->intval = !batfet_disable; in bq24190_battery_get_online()
1608 BQ24190_REG_MOC_BATFET_DISABLE_SHIFT, !val->intval); in bq24190_battery_set_online()
1624 val->intval = temp; in bq24190_battery_get_temp_alert_max()
1635 ARRAY_SIZE(bq24190_ictrc_treg_values), val->intval); in bq24190_battery_set_temp_alert_max()
1644 dev_warn(bdi->dev, "warning: /sys/class/power_supply/bq24190-battery is deprecated\n"); in bq24190_battery_get_property()
1645 dev_dbg(bdi->dev, "prop: %d\n", psp); in bq24190_battery_get_property()
1647 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_battery_get_property()
1662 /* Could be Li-on or Li-polymer but no way to tell which */ in bq24190_battery_get_property()
1663 val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; in bq24190_battery_get_property()
1670 val->intval = POWER_SUPPLY_SCOPE_SYSTEM; in bq24190_battery_get_property()
1674 ret = -ENODATA; in bq24190_battery_get_property()
1677 pm_runtime_put_autosuspend(bdi->dev); in bq24190_battery_get_property()
1689 dev_warn(bdi->dev, "warning: /sys/class/power_supply/bq24190-battery is deprecated\n"); in bq24190_battery_set_property()
1690 dev_dbg(bdi->dev, "prop: %d\n", psp); in bq24190_battery_set_property()
1692 ret = pm_runtime_resume_and_get(bdi->dev); in bq24190_battery_set_property()
1704 ret = -EINVAL; in bq24190_battery_set_property()
1707 pm_runtime_put_autosuspend(bdi->dev); in bq24190_battery_set_property()
1739 .name = "bq24190-battery",
1754 ret = extcon_set_state_sync(bdi->edev, EXTCON_USB, otg_enabled); in bq24190_configure_usb_otg()
1756 dev_err(bdi->dev, "Can't set extcon state to %d: %d\n", in bq24190_configure_usb_otg()
1770 battery_mask_f |= bdi->info->ntc_fault_mask; in bq24190_check_status()
1774 dev_err(bdi->dev, "Can't read SS reg: %d\n", ret); in bq24190_check_status()
1782 dev_err(bdi->dev, "Can't read F reg: %d\n", ret); in bq24190_check_status()
1792 if (f_reg != bdi->f_reg) { in bq24190_check_status()
1793 dev_warn(bdi->dev, in bq24190_check_status()
1798 !!(f_reg & bdi->info->ntc_fault_mask)); in bq24190_check_status()
1800 mutex_lock(&bdi->f_reg_lock); in bq24190_check_status()
1801 if ((bdi->f_reg & battery_mask_f) != (f_reg & battery_mask_f)) in bq24190_check_status()
1803 if ((bdi->f_reg & ~battery_mask_f) != (f_reg & ~battery_mask_f)) in bq24190_check_status()
1805 bdi->f_reg = f_reg; in bq24190_check_status()
1806 mutex_unlock(&bdi->f_reg_lock); in bq24190_check_status()
1809 if (ss_reg != bdi->ss_reg) { in bq24190_check_status()
1811 * The device is in host mode so when PG_STAT goes from 1->0 in bq24190_check_status()
1814 if ((bdi->ss_reg & BQ24190_REG_SS_PG_STAT_MASK) && in bq24190_check_status()
1821 dev_err(bdi->dev, "Can't access ISC reg: %d\n", in bq24190_check_status()
1825 if ((bdi->ss_reg & battery_mask_ss) != (ss_reg & battery_mask_ss)) in bq24190_check_status()
1827 if ((bdi->ss_reg & ~battery_mask_ss) != (ss_reg & ~battery_mask_ss)) in bq24190_check_status()
1829 bdi->ss_reg = ss_reg; in bq24190_check_status()
1833 power_supply_changed(bdi->charger); in bq24190_check_status()
1836 if (alert_battery && bdi->battery) in bq24190_check_status()
1837 power_supply_changed(bdi->battery); in bq24190_check_status()
1839 dev_dbg(bdi->dev, "ss_reg: 0x%02x, f_reg: 0x%02x\n", ss_reg, f_reg); in bq24190_check_status()
1847 bdi->irq_event = true; in bq24190_irq_handler_thread()
1848 error = pm_runtime_resume_and_get(bdi->dev); in bq24190_irq_handler_thread()
1850 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", error); in bq24190_irq_handler_thread()
1854 pm_runtime_put_autosuspend(bdi->dev); in bq24190_irq_handler_thread()
1855 bdi->irq_event = false; in bq24190_irq_handler_thread()
1878 dev_err(bdi->dev, "Error unknown model: 0x%02x\n", v); in bq24190_check_chip()
1879 return -ENODEV; in bq24190_check_chip()
1902 dev_err(bdi->dev, "Error unknown model: 0x%02x\n", v); in bq24296_check_chip()
1903 return -ENODEV; in bq24296_check_chip()
1913 ret = bdi->info->check_chip(bdi); in bq24190_hw_init()
1925 return bq24190_read(bdi, BQ24190_REG_SS, &bdi->ss_reg); in bq24190_hw_init()
1930 const char * const s = "ti,system-minimum-microvolt"; in bq24190_get_config()
1934 idx = bdi->info->ichg_array_size - 1; in bq24190_get_config()
1936 bdi->ichg_max = bq24190_ccc_ichg_values[idx]; in bq24190_get_config()
1938 idx = ARRAY_SIZE(bq24190_cvc_vreg_values) - 1; in bq24190_get_config()
1939 bdi->vreg_max = bq24190_cvc_vreg_values[idx]; in bq24190_get_config()
1941 if (device_property_read_u32(bdi->dev, s, &v) == 0) { in bq24190_get_config()
1945 bdi->sys_min = v; in bq24190_get_config()
1947 dev_warn(bdi->dev, "invalid value for %s: %u\n", s, v); in bq24190_get_config()
1950 if (!power_supply_get_battery_info(bdi->charger, &info)) { in bq24190_get_config()
1951 v = info->precharge_current_ua / 1000; in bq24190_get_config()
1954 bdi->iprechg = v; in bq24190_get_config()
1956 dev_warn(bdi->dev, "invalid value for battery:precharge-current-microamp: %d\n", in bq24190_get_config()
1959 v = info->charge_term_current_ua / 1000; in bq24190_get_config()
1962 bdi->iterm = v; in bq24190_get_config()
1964 dev_warn(bdi->dev, "invalid value for battery:charge-term-current-microamp: %d\n", in bq24190_get_config()
1968 v = info->constant_charge_current_max_ua; in bq24190_get_config()
1969 if (v >= bq24190_ccc_ichg_values[0] && v <= bdi->ichg_max) in bq24190_get_config()
1970 bdi->ichg = bdi->ichg_max = v; in bq24190_get_config()
1972 v = info->constant_charge_voltage_max_uv; in bq24190_get_config()
1973 if (v >= bq24190_cvc_vreg_values[0] && v <= bdi->vreg_max) in bq24190_get_config()
1974 bdi->vreg = bdi->vreg_max = v; in bq24190_get_config()
1976 power_supply_put_battery_info(bdi->charger, info); in bq24190_get_config()
2065 struct i2c_adapter *adapter = client->adapter; in bq24190_probe()
2066 struct device *dev = &client->dev; in bq24190_probe()
2073 return -ENODEV; in bq24190_probe()
2079 return -ENOMEM; in bq24190_probe()
2082 bdi->client = client; in bq24190_probe()
2083 bdi->dev = dev; in bq24190_probe()
2084 strscpy(bdi->model_name, id->name, sizeof(bdi->model_name)); in bq24190_probe()
2085 bdi->info = i2c_get_match_data(client); in bq24190_probe()
2086 mutex_init(&bdi->f_reg_lock); in bq24190_probe()
2087 bdi->charge_type = POWER_SUPPLY_CHARGE_TYPE_FAST; in bq24190_probe()
2088 bdi->f_reg = 0; in bq24190_probe()
2089 bdi->ss_reg = BQ24190_REG_SS_VBUS_STAT_MASK; /* impossible state */ in bq24190_probe()
2090 INIT_DELAYED_WORK(&bdi->input_current_limit_work, in bq24190_probe()
2095 if (client->irq <= 0) { in bq24190_probe()
2097 return -EINVAL; in bq24190_probe()
2100 bdi->edev = devm_extcon_dev_allocate(dev, bq24190_usb_extcon_cable); in bq24190_probe()
2101 if (IS_ERR(bdi->edev)) in bq24190_probe()
2102 return PTR_ERR(bdi->edev); in bq24190_probe()
2104 ret = devm_extcon_dev_register(dev, bdi->edev); in bq24190_probe()
2126 bdi->charger = power_supply_register(dev, &bq24190_charger_desc, in bq24190_probe()
2128 if (IS_ERR(bdi->charger)) { in bq24190_probe()
2130 ret = PTR_ERR(bdi->charger); in bq24190_probe()
2136 if (!device_property_read_bool(dev, "omit-battery-class")) { in bq24190_probe()
2138 bdi->battery = power_supply_register(dev, &bq24190_battery_desc, in bq24190_probe()
2140 if (IS_ERR(bdi->battery)) { in bq24190_probe()
2142 ret = PTR_ERR(bdi->battery); in bq24190_probe()
2159 ret = bq24190_configure_usb_otg(bdi, bdi->ss_reg); in bq24190_probe()
2163 bdi->initialized = true; in bq24190_probe()
2165 ret = devm_request_threaded_irq(dev, client->irq, NULL, in bq24190_probe()
2168 "bq24190-charger", bdi); in bq24190_probe()
2178 enable_irq_wake(client->irq); in bq24190_probe()
2185 if (!IS_ERR_OR_NULL(bdi->battery)) in bq24190_probe()
2186 power_supply_unregister(bdi->battery); in bq24190_probe()
2187 power_supply_unregister(bdi->charger); in bq24190_probe()
2201 cancel_delayed_work_sync(&bdi->input_current_limit_work); in bq24190_remove()
2202 error = pm_runtime_resume_and_get(bdi->dev); in bq24190_remove()
2204 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", error); in bq24190_remove()
2207 if (bdi->battery) in bq24190_remove()
2208 power_supply_unregister(bdi->battery); in bq24190_remove()
2209 power_supply_unregister(bdi->charger); in bq24190_remove()
2211 pm_runtime_put_sync(bdi->dev); in bq24190_remove()
2212 pm_runtime_dont_use_autosuspend(bdi->dev); in bq24190_remove()
2213 pm_runtime_disable(bdi->dev); in bq24190_remove()
2221 bdi->info->set_otg_vbus(bdi, false); in bq24190_shutdown()
2229 if (!bdi->initialized) in bq24190_runtime_suspend()
2232 dev_dbg(bdi->dev, "%s\n", __func__); in bq24190_runtime_suspend()
2242 if (!bdi->initialized) in bq24190_runtime_resume()
2245 if (!bdi->irq_event) { in bq24190_runtime_resume()
2246 dev_dbg(bdi->dev, "checking events on possible wakeirq\n"); in bq24190_runtime_resume()
2259 error = pm_runtime_resume_and_get(bdi->dev); in bq24190_pm_suspend()
2261 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", error); in bq24190_pm_suspend()
2266 pm_runtime_put_autosuspend(bdi->dev); in bq24190_pm_suspend()
2278 bdi->f_reg = 0; in bq24190_pm_resume()
2279 bdi->ss_reg = BQ24190_REG_SS_VBUS_STAT_MASK; /* impossible state */ in bq24190_pm_resume()
2281 error = pm_runtime_resume_and_get(bdi->dev); in bq24190_pm_resume()
2283 dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", error); in bq24190_pm_resume()
2287 bq24190_read(bdi, BQ24190_REG_SS, &bdi->ss_reg); in bq24190_pm_resume()
2290 pm_runtime_put_autosuspend(bdi->dev); in bq24190_pm_resume()
2293 /* Things may have changed while suspended so alert upper layer */ in bq24190_pm_resume()
2294 power_supply_changed(bdi->charger); in bq24190_pm_resume()
2295 if (bdi->battery) in bq24190_pm_resume()
2296 power_supply_changed(bdi->battery); in bq24190_pm_resume()
2337 .name = "bq24190-charger",