Lines Matching full:when

241  *		Field only valid when for the received frame type the corresponding
245 * Field only valid when for the received frame type the corresponding
309 * Field only valid when AST_based_lookup_valid == 1.
319 * When set, all frames (data only ?) shall be encrypted. If
332 * Field only valid when key_type is set to wep_varied_width.
337 * When set, the BSSID of the incoming frame matched one of
340 * Field only valid when bssid_hit is set.
345 * Field only valid when mpdu_qos_control_valid is set
362 * When set, the received frame was an NDP frame, and thus
365 * When set, a PHY error was received before MAC received any
369 * When set, a PHY error was received before MAC received the
373 * Set when RXPCU detected a version error in the Frame control
377 * When set, AST based lookup for this frame has found a valid
381 * When set, a ranging NDPA or a ranging NDP was received.
402 * When set, the field Mpdu_Frame_control_field has valid information
405 * When set, the field Mpdu_duration_field has valid information
408 * When set, the fields mac_addr_adx_..... have valid information
412 * When set, the fields mpdu_sequence_control_field and mpdu_sequence_number
419 * When set, the field mpdu_qos_control_field, mpdu_ht_control has valid
425 * When set, the encryption related info fields, like IV and
431 * Field only valid when Mpdu_sequence_control_valid is set
441 * Field only valid when Mpdu_frame_control_valid is set
446 * Field only valid when Mpdu_frame_control_valid is set
451 * Field only valid when Mpdu_frame_control_valid is set.
455 * Field only valid when Mpdu_frame_control_valid is set.
456 * Retry bit from the frame control. Only valid when first_msdu is set
459 * Field only valid when Mpdu_sequence_control_valid is set.
464 * Field only valid when Frame_encryption_info_valid is set
472 * When RXPCU sets bit 'ast_index_not_found or ast_index_timeout',
507 * Set when no 802.11 to nwifi/ethernet hdr conversion is done
517 * 0. The PPDU start status will only be valid when this bit
521 * Multicast / broadcast indicator. Only set when the MAC
523 * matches one of the 4 BSSID registers. Only set when
527 * Only valid when first_msdu is set. Indicates no AST matching
531 * Only valid when first_msdu is set. Indicates an unsuccessful
536 * when first_msdu is set.
539 * Set if packet is not a non-QoS data frame. Only set when
544 * data format. Only set when first_msdu is set.
547 * Set if packet is a management packet. Only set when
551 * Set if packet is a control packet. Only set when first_msdu
555 * Set if more bit in frame control is set. Only set when
560 * control field is set. Only set when first_msdu is set.
568 * set when first_msdu is set.
587 * Frame control field in header. Only valid when the field is marked valid.
590 * Duration field in header. Only valid when the field is marked valid.
593 * MAC addresses in the received frame. Only valid when corresponding
597 * QoS/HT control fields from header. Valid only when corresponding fields
624 * Multi-link receiver address1,2. Only valid when corresponding
913 * MPDU length before decapsulation. Only valid when first_msdu is
946 * of a dynamic A-MSDU when DA is compressed.
950 * of a dynamic A-MSDU when SA is compressed.
1013 * valid when last_msdu is set.
1051 * When set, this is a Mesh (11s) STA.
1063 * set when either the more_frag bit is set in the frame control
1064 * or the fragment number is not zero. Only set when first_msdu
1119 * The key ID octet from the IV. Only valid when first_msdu is set.
1166 * When set, use STBC transmission rates.
1249 * When set, this MSDU includes the 'Mesh Control' field
1276 * Field only valid when pkt type is HT, VHT or HE. Values are
1291 * Field only valid when
1325 * Timestamp that indicates when the PPDU that contained this MPDU
1350 * 0. The PPDU start status will only be valid when this bit
1354 * Multicast / broadcast indicator. Only set when the MAC
1356 * matches one of the 4 BSSID registers. Only set when
1360 * Only valid when first_msdu is set. Indicates no AST matching
1364 * Only valid when first_msdu is set. Indicates an unsuccessful
1369 * when first_msdu is set.
1372 * Set if packet is not a non-QoS data frame. Only set when
1377 * data format. Only set when first_msdu is set.
1380 * Set if packet is a management packet. Only set when
1384 * Set if packet is a control packet. Only set when first_msdu
1388 * Set if more bit in frame control is set. Only set when
1393 * control field is set. Only set when first_msdu is set.
1402 * set when first_msdu is set.