7 Charger Manager provides in-kernel battery charger management that
8 requires temperature monitoring during suspend-to-RAM state
12 Charger Manager is a platform_driver with power-supply-class entries.
13 An instance of Charger Manager (a platform-device created with Charger-Manager)
26 own power-supply-class and each power-supply-class can provide
28 aggregates charger-related information from multiple sources and
29 shows combined information as a single power-supply-class.
31 * Support for in suspend-to-RAM polling (with suspend_again callback)
32 While the battery is being charged and the system is in suspend-to-RAM,
50 * Support for premature full-battery event handling
52 "fullbatt_vchkdrop_ms" from the full-battery event, the framework
56 * Support for uevent-notify
57 With the charger-related events, the device sends
60 2. Global Charger-Manager Data related with suspend_again
62 In order to setup Charger Manager with suspend-again feature
63 (in-suspend monitoring), the user should provide charger_global_desc
65 This charger_global_desc data for in-suspend monitoring is global
69 and it will manage in-suspend monitoring for all instances of Charger Manager.
72 properly in order to activate in-suspend monitoring:
78 saves and restores the alarm value and use the previously-defined
80 Charger Manager does not interfere with previously-defined alarms.
84 the wakeup-from-suspend is caused only by the alarm of "rtc" in the
92 assumes that the suspend-duration is same as the alarm length.
107 (in-suspend monitoring) results in "normal".
109 4. Charger-Manager Data (struct charger_desc)
118 The power-supply-class name of the battery. Default is
134 If both have non-zero values, Charger Manager will check the
140 fuel gauges or charger devices/chips.
143 If specified with a non-zero value, Charger Manager assumes
158 get battery presence information from fuel gauge.
163 An array ending with NULL that has power-supply-class names of
164 chargers. Each power-supply-class should provide "PRESENT" (if
175 Power-supply-class name of the fuel gauge.
186 5. Notify Charger-Manager of charger events: cm_notify_event()
192 associated with Charger-Manager. The parameter "type"
199 At the charger/battery-related events such as battery-pulled-out,
200 charger-pulled-out, charger-inserted, DCIN-over/under-voltage, charger-stopped,
203 a) charger-on/off b) external-power-in/out c) battery-in/out (while charging)