Lines Matching +full:dc +full:- +full:dc +full:- +full:phase

11     Addresses scanned: -
15 - http://focus.ti.com/lit/ds/symlink/ucd9220.pdf
16 - http://focus.ti.com/lit/ds/symlink/ucd9222.pdf
17 - http://focus.ti.com/lit/ds/symlink/ucd9224.pdf
18 - http://focus.ti.com/lit/ds/symlink/ucd9240.pdf
19 - http://focus.ti.com/lit/ds/symlink/ucd9244.pdf
20 - http://focus.ti.com/lit/ds/symlink/ucd9246.pdf
21 - http://focus.ti.com/lit/ds/symlink/ucd9248.pdf
23 Author: Guenter Roeck <linux@roeck-us.net>
27 -----------
30 UCD9248 are multi-rail, multi-phase synchronous buck digital PWM controllers
31 designed for non-isolated DC/DC power applications. The devices integrate
32 dedicated circuitry for DC/DC loop management with flash memory and a serial
40 -----------
42 This driver does not auto-detect devices. You will have to instantiate the
43 devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
48 ---------------------
55 -------------
57 The following attributes are supported. Limits are read-write; all other
58 attributes are read-only.
73 in[2-5]_label "vout[1-4]".
74 in[2-5]_input Measured voltage. From READ_VOUT register.
75 in[2-5]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
76 in[2-5]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
77 in[2-5]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
78 in[2-5]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT
80 in[2-5]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
81 in[2-5]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
82 in[2-5]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT
84 in[2-5]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT
90 curr[2-5]_label "iout[1-4]".
91 curr[2-5]_input Measured current. From READ_IOUT register.
92 curr[2-5]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
93 curr[2-5]_lcrit Critical minimum output current. From
95 curr[2-5]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT
97 curr[2-5]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
98 curr[2-5]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
103 power[2-5]_input Measured output power. From READ_POUT register.
104 power[2-5]_label "pout[1-4]"
110 temp[1-5]_input Measured temperatures. From READ_TEMPERATURE_1 and
112 temp1 is the chip internal temperature. temp[2-5] are
113 rail temperatures. temp[2-5] attributes are only
116 temp[1-5]_max Maximum temperature. From OT_WARN_LIMIT register.
117 temp[1-5]_crit Critical high temperature. From OT_FAULT_LIMIT register.
118 temp[1-5]_max_alarm Temperature high alarm.
119 temp[1-5]_crit_alarm Temperature critical high alarm.