Lines Matching +full:output +full:- +full:only
10 Addresses scanned: -
18 Addresses scanned: -
26 Addresses scanned: -
34 Addresses scanned: -
42 Addresses scanned: -
50 Addresses scanned: -
57 Guenter Roeck <linux@roeck-us.net>
61 -----------
63 Chips in this series are multi-phase step-down converters with one or two
64 output channels and up to 8 phases per channel.
68 -----------
77 # echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
81 ----------------
90 TPS53679, TPS53681, TPS53688 only.
94 TPS53679, TPS53681, TPS53688 only.
100 in[N]_label "vout[1-2]"
102 - TPS53647, TPS53667: N=2
103 - TPS53679, TPS53588: N=2,3
105 in[N]_input Measured output voltage.
109 TPS53679, TPS53681, TPS53688 only.
113 TPS53679, TPS53681, TPS53688 only.
115 in[N]_alarm Output voltage alarm.
117 TPS53647, TPS53667 only.
119 in[N]_crit Critical maximum output voltage.
121 TPS53679, TPS53681, TPS53688 only.
123 in[N]_crit_alarm Output voltage critical high alarm.
125 TPS53679, TPS53681, TPS53688 only.
129 - TPS53647, TPS53667: N=1
130 - TPS53679, TPS53681, TPS53588: N=1,2
144 power[N]_label "pout[1-2]".
146 - TPS53647, TPS53667: N=2
147 - TPS53676, TPS53679, TPS53681, TPS53588: N=2,3
149 power[N]_input Measured output power.
163 curr[N]_label "iout[1-2]" or "iout1.[0-5]".
165 The first digit is the output channel, the second
166 digit is the phase within the channel. Per-phase
167 telemetry supported on TPS53676 and TPS53681 only.
169 - TPS53647, TPS53667: N=2
170 - TPS53679, TPS53588: N=2,3
171 - TPS53676: N=2-8
172 - TPS53681: N=2-9
174 curr[N]_input Measured output current.
176 curr[N]_max Maximum output current.
178 curr[N]_crit Critical high output current.
180 curr[N]_max_alarm Output current high alarm.
182 curr[N]_crit_alarm Output current critical high alarm.
184 Limit and alarm attributes are only available for
185 non-phase telemetry (iout1, iout2).