Lines Matching +full:wire +full:- +full:or
8 Prefix: 'lm85b' or 'lm85c'
79 - Philip Pokorny <ppokorny@penguincomputing.com>,
80 - Frodo Looijaard <frodol@dds.nl>,
81 - Richard Barrington <rich_b_nz@clear.net.nz>,
82 - Margit Schubert-While <margitsw@t-online.de>,
83 - Justin Thiessen <jthiessen@penguincomputing.com>
86 -----------
92 The LM85 uses the 2-wire interface compatible with the SMBUS 2.0
94 temperatures and five (5) voltages. It has four (4) 16-bit counters for
107 423 or socket 478 package. They can also measure temperature using a
127 ----------------
132 speed of a two wire fan, but the input conditioning circuitry is different
133 for 3-wire and 2-wire mode. For this reason, the 2-wire fan modes are not
142 The ADM1027, ADT7463 and ADT7468 have a 10-bit ADC and can therefore
152 The ADT7468 has a high-frequency PWM mode, where all PWM outputs are
153 driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
160 from National (AN-1260) with some additional information about the LM85.
167 fans in a PC or embedded system. The EMC6D101, available in a 24-pin SSOP
168 package, and the EMC6D100, available in a 28-pin SSOP package, are designed
180 25.7 kHz, 27.7 kHz and 30 kHz), which can be configured on a per-PWM basis.
183 -----------------------
194 that can be used to signal the chipset in case a limit is exceeded or the
197 of the other functions (PWM2 or IN0). This functionality is not implemented
206 -------------------
217 - temperature below which fans should be off or spinning very low.
219 - temperature over which fans start to spin.
221 - temperature when fans spin at full speed.
223 - temperature when all fans will run full speed.
234 - this specifies the PWM value for temp#_auto_temp_off
238 - this flags selects for temp#_auto_temp_off temperature
240 pwm#_auto_pwm_min or write 0 to let them off.
253 - controls zone that is associated with PWM
263 23 Controlled by higher temp of Zone 2 or 3
264 123 Controlled by highest temp of Zone 1, 2 or 3
266 -1 PWM always 100% (full on)
267 -2 Manual control (write to 'pwm#' to set)
272 see the LM85 datasheet or Application Note AN-1260. These features
276 The number of pulses-per-rev of the fans can be set, Tach monitoring