Lines Matching +full:temperature +full:- +full:mode

79        - Philip Pokorny <ppokorny@penguincomputing.com>,
80 - Frodo Looijaard <frodol@dds.nl>,
81 - Richard Barrington <rich_b_nz@clear.net.nz>,
82 - Margit Schubert-While <margitsw@t-online.de>,
83 - Justin Thiessen <jthiessen@penguincomputing.com>
86 -----------
92 The LM85 uses the 2-wire interface compatible with the SMBUS 2.0
94 temperatures and five (5) voltages. It has four (4) 16-bit counters for
105 Remote 1 is generally the CPU temperature. These inputs are designed to
107 423 or socket 478 package. They can also measure temperature using a
112 three temperature sensors. Each PWM output is individually adjustable and
117 Each of the measured inputs (voltage, temperature, fan speed) has
127 ----------------
133 for 3-wire and 2-wire mode. For this reason, the 2-wire fan modes are not
135 mode. If you've designed your own ADM1027, you'll have to modify the
138 To smooth the response of fans to changes in temperature, the LM85 has an
142 The ADM1027, ADT7463 and ADT7468 have a 10-bit ADC and can therefore
144 to the temperature readings that is automatically applied during
152 The ADT7468 has a high-frequency PWM mode, where all PWM outputs are
153 driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
160 from National (AN-1260) with some additional information about the LM85.
167 fans in a PC or embedded system. The EMC6D101, available in a 24-pin SSOP
168 package, and the EMC6D100, available in a 28-pin SSOP package, are designed
174 of voltage and temperature channels.
180 25.7 kHz, 27.7 kHz and 30 kHz), which can be configured on a per-PWM basis.
183 -----------------------
195 temperature sensors fail. Individual sensor interrupts can be masked so
202 control dynamic Tmin feature can be enabled to keep the system temperature
206 -------------------
212 Each temperature sensor is associated with a Zone. There are three
214 temperature configuration points:
217 - temperature below which fans should be off or spinning very low.
219 - temperature over which fans start to spin.
221 - temperature when fans spin at full speed.
223 - temperature when all fans will run full speed.
234 - this specifies the PWM value for temp#_auto_temp_off
235 temperature. (PWM value from 0 to 255)
238 - this flags selects for temp#_auto_temp_off temperature
253 - controls zone that is associated with PWM
266 -1 PWM always 100% (full on)
267 -2 Manual control (write to 'pwm#' to set)
271 features. Tach. mode and Spinup Control. For more details on these,
272 see the LM85 datasheet or Application Note AN-1260. These features
276 The number of pulses-per-rev of the fans can be set, Tach monitoring
284 adjust the Tmin value to maintain the measured temperature sensor at a
285 specified temperature. There isn't much documentation on this feature in