Lines Matching +full:over +full:- +full:volt
21 - Frodo Looijaard <frodol@dds.nl>,
22 - Kyösti Mälkki <kmalkki@cc.hut.fi>
23 - Hong-Gunn Chew <hglinux@gunnet.org>
24 - Jean Delvare <jdelvare@suse.de>
27 -----------
44 temperature is above the over temperature limit, and has not yet dropped
46 situation. Measurements are guaranteed between -10 degrees and +110
47 degrees, with a accuracy of +/-3 degrees.
62 measures voltages between 0.000 and 5.865 volt, with a resolution of 0.023
63 volt. The other inputs measure voltages between 0.000 and 4.845 volt, with
64 a resolution of 0.019 volt. Note that revision 0x00 chips do not support
77 you can easily miss once-only alarms.