Lines Matching +full:temperature +full:- +full:mode

1 .. SPDX-License-Identifier: GPL-2.0
8 ----------
10 ANS T13/1699-D
11 Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS)
14 Information technology - SCSI Primary Commands - 4 (SPC-4)
17 Information technology - SCSI / ATA Translation - 5 (SAT-5)
21 -----------
23 This driver supports reporting the temperature of disk and solid state
24 drives with temperature sensors.
27 the current drive temperature and, if available, temperature limits
30 the drive temperature.
34 ----------
36 Reading the drive temperature may reset the spin down timer on some drives.
40 With the WD120EFAX drive, reading the drive temperature using the drivetemp
41 driver is still possible _after_ it transitioned to standby mode, and
42 reading the drive temperature in this mode will not cause the drive to
43 change its mode (meaning the drive will not spin up). It is unknown if other
46 A known workaround for WD120EFAX drives is to read the drive temperature at
47 intervals larger than twice the spin-down time. Otherwise affected drives
52 -------------
56 milli-degrees Celsius.
59 temp1_input Current drive temperature
60 temp1_lcrit Minimum temperature limit. Operating the device below
61 this temperature may cause physical damage to the
64 temp1_max Maximum recommended continuous operating temperature
65 temp1_crit Maximum temperature limit. Operating the device above
66 this temperature may cause physical damage to the
68 temp1_lowest Minimum temperature seen this power cycle
69 temp1_highest Maximum temperature seen this power cycle