Lines Matching +full:temperature +full:- +full:mode
19 -----------
22 The chip has one on-chip and one remote temperature sensor and one pwm fan
29 temp1_input ro on-chip temperature
37 temp2_input ro remote temperature
52 mode 4.
55 pwm1_enable rw regulator mode, 1=open loop, 2=fan controlled
56 by remote temperature, 3=fan controlled by
57 combination of the on-chip temperature and
58 remote-sensor temperature,
61 pwm1_mode rw Fan duty control mode (0=DC, 1=PWM)
64 temperature channels.
65 pwm1_auto_point2_pwm rw This value is shared for both temperature
68 temperature channels.
71 which is rw. Below this temperature fan stops.
72 temp1_auto_point2_temp rw The low-temperature limit of the proportional
73 range. Below this temperature
78 temp1_auto_point3_temp rw Above this temperature fan runs at maximum
86 it defines the passive cooling temperature.
87 Below this temperature the fan stops in
88 the closed loop mode.
89 temp2_auto_point2_temp rw The low-temperature limit of the proportional
90 range. Below this temperature
95 temp2_auto_point3_temp rw Above this temperature fan runs at maximum
104 -----------------
112 - init=1,
113 - pwminv: 0 default pwm output, 1 inverts pwm output.