Lines Matching refs:PWM
59 for measuring fan speed. There are three (3) PWM outputs that can be used
62 A sophisticated control system for the PWM outputs is designed into the
64 three temperature sensors. Each PWM output is individually adjustable and
65 programmable. Once configured, the ADT747x will adjust the PWM outputs in
67 This feature can also be disabled for manual control of the PWM's.
122 an optimal configuration for the automatic PWM control.
127 The driver exposes two trip points per PWM channel.
129 - point1: Set the PWM speed at the lower temperature bound
130 - point2: Set the PWM speed at the higher temperature bound
132 The ADT747x will scale the PWM linearly between the lower and higher PWM
135 PWM outputs, and a given PWM output can be controlled by several temperature
136 channels. As a result, the ADT747x may compute more than one PWM value
138 fan speed) is applied. PWM values range from 0 (off) to 255 (full speed).
141 the PWM control exceeds temp#_max.
143 At Tmin - hysteresis the PWM output can either be off (0% duty cycle) or at the