Lines Matching refs:reading
10 Winbond (W83L950D). And no, reading the manual for this specific uC or
46 hold 0x09 and will only hold 0x08 after reading CMD first, so CMD must be read
64 that many bytes, reading / writing more will fail, the results when writing
77 when reading you should always use the read address and when writing the
94 After reading CMD, DATA should hold 0x08 which means that the uGuru is ready
197 This byte holds the reading from the sensor. Sensors in Bank1 can be both
202 Volt sensors use a linear scale, a reading 0 corresponds with 0 volt and a
203 reading of 255 with 3494 mV. The sensors for higher voltages however are
208 Temp sensors also use a linear scale, a reading of 0 corresponds with 0 degree
209 Celsius and a reading of 255 with a reading of 255 degrees Celsius.
302 This byte holds the reading from the sensor. 0-255 = 0-15300 (linear)
330 the voltage / clock programming out, I tried reading and only reading banks
331 0-0x30 with the reading code used for the sensor banks (0x20-0x28) and this