Lines Matching +full:over +full:- +full:volt
14 Olle Sandberg <ollebull@gmail.com>, 2005-05-25
27 Hans de Goede <j.w.r.degoede@hhs.nl>, 28-01-2006
33 As far as known the uGuru is always placed at and using the (ISA) I/O-ports
34 0xE0 and 0xE4, so we don't have to scan any port-range, just check what the two
35 ports are holding for detection. We will refer to 0xE0 as CMD (command-port)
39 present. We have to check for two different values at data-port, because
41 later on attached again data-port will hold 0x08, more about this later.
57 ----------
82 -----------
101 ----------------------------------------------
114 -------
133 -------
152 -------
167 --------------------
172 This byte holds the alarm flags for sensor 0-7 of Sensor Bank1, with bit 0
176 This byte holds the alarm flags for sensor 8-15 of Sensor Bank1, with bit 0
180 This byte holds the alarm flags for sensor 0-5 of Sensor Bank2, with bit 0
185 --------------------------------------------
189 - Sensor 0 CPU temp
190 - Sensor 1 SYS temp
191 - Sensor 3 CPU core volt
192 - Sensor 4 DDR volt
193 - Sensor 10 DDR Vtt volt
194 - Sensor 15 PWM temp
198 volt and temp sensors, this is motherboard specific. The uGuru however does
202 Volt sensors use a linear scale, a reading 0 corresponds with 0 volt and a
205 in use result in ranges of: 0-4361mV, 0-6248mV or 0-14510mV. 3.3 volt sources
206 use the 0-4361mV range, 5 volt the 0-6248mV and 12 volt the 0-14510mV .
213 ---------------------------------------------------------------------------
224 Give an alarm if measured temp is over the warning threshold (RW) [1]_
227 Give an alarm if measured volt is over the max threshold (RW) [2]_
230 Give an alarm if measured volt is under the min threshold (RW) [2]_
236 1 if alarm cause measured temp is over the warning threshold (R)
239 1 if alarm cause measured volt is over the max threshold (R)
242 1 if alarm cause measured volt is under the min threshold (R)
245 - Volt sensor: Shutdown if alarm persist for more than 4 seconds (RW)
246 - Temp sensor: Shutdown if temp is over the shutdown threshold (RW)
250 .. [2] This bit is only honored/used by the uGuru if a volt sensor is connected
256 - Temp sensor: warning threshold (scale as bank 0x21)
257 - Volt sensor: min threshold (scale as bank 0x21)
260 - Temp sensor: shutdown threshold (scale as bank 0x21)
261 - Volt sensor: max threshold (scale as bank 0x21)
265 ---------------------------------------------------------------------------
268 - Sensor 0 usually controls the CPU fan
269 - Sensor 1 usually controls the NB (or chipset for single chip) fan
270 - Sensor 2 usually controls the System fan
277 0-255 = 0-12v (linear), specify voltage at which fan will rotate when under
281 0-255 = 0-12v (linear), specify voltage at which fan will rotate when above
292 ---------------------------------------------
297 - Sensor 0: CPU fan speed
298 - Sensor 1: NB (or chipset for single chip) fan speed
299 - Sensor 2: SYS fan speed
302 This byte holds the reading from the sensor. 0-255 = 0-15300 (linear)
306 -----------------------------------------------------------------------------
331 0-0x30 with the reading code used for the sensor banks (0x20-0x28) and this