Lines Matching +full:fiber +full:- +full:mode
7 - micrel,led-mode : LED mode value to set for PHYs with configurable LEDs.
9 Configure the LED mode with single value. The list of PHYs and the
21 See the respective PHY datasheet for the mode values.
23 - micrel,rmii-reference-clock-select-25-mhz: RMII Reference Clock Select
24 bit selects 25 MHz mode
27 than 50 MHz clock mode.
30 non-standard, inverted function of this configuration bit.
31 Specifically, a clock reference ("rmii-ref" below) is always needed to
32 actually select a mode.
34 - clocks, clock-names: contains clocks according to the common clock bindings.
37 - KSZ8021, KSZ8031, KSZ8081, KSZ8091: "rmii-ref": The RMII reference
40 - micrel,fiber-mode: If present the PHY is configured to operate in fiber mode
42 Some PHYs, such as the KSZ8041FTL variant, support fiber mode, enabled
44 registers whether the PHY is in fiber mode, so this boolean device tree
47 In fiber mode, auto-negotiation is disabled and the PHY can only work in
48 100base-fx (full and half duplex) modes.
50 - coma-mode-gpios: If present the given gpio will be deasserted when the
53 Some PHYs have a COMA mode input pin which puts the PHY into
54 isolate and power-down mode. On some boards this input is connected