Lines Matching +full:bus +full:- +full:power
1 What: /sys/bus/platform/devices/dfl-fme.0/ports_num
5 Description: Read-only. One DFL FPGA device may have more than 1
9 What: /sys/bus/platform/devices/dfl-fme.0/bitstream_id
13 Description: Read-only. It returns Bitstream (static FPGA region)
17 What: /sys/bus/platform/devices/dfl-fme.0/bitstream_metadata
21 Description: Read-only. It returns Bitstream (static FPGA region) meta
25 What: /sys/bus/platform/devices/dfl-fme.0/cache_size
29 Description: Read-only. It returns cache size of this FPGA device.
31 What: /sys/bus/platform/devices/dfl-fme.0/fabric_version
35 Description: Read-only. It returns fabric version of this FPGA device.
39 What: /sys/bus/platform/devices/dfl-fme.0/socket_id
43 Description: Read-only. It returns socket_id to indicate which socket
48 What: /sys/bus/platform/devices/dfl-fme.0/errors/pcie0_errors
52 Description: Read-Write. Read this file for errors detected on pcie0 link.
54 fails with -EINVAL if input parsing fails or input error code
57 What: /sys/bus/platform/devices/dfl-fme.0/errors/pcie1_errors
61 Description: Read-Write. Read this file for errors detected on pcie1 link.
63 fails with -EINVAL if input parsing fails or input error code
66 What: /sys/bus/platform/devices/dfl-fme.0/errors/nonfatal_errors
70 Description: Read-only. It returns non-fatal errors detected.
72 What: /sys/bus/platform/devices/dfl-fme.0/errors/catfatal_errors
76 Description: Read-only. It returns catastrophic and fatal errors detected.
78 What: /sys/bus/platform/devices/dfl-fme.0/errors/inject_errors
82 Description: Read-Write. Read this file to check errors injected. Write this
84 -EINVAL if input parsing fails or input inject error code isn't
87 What: /sys/bus/platform/devices/dfl-fme.0/errors/fme_errors
91 Description: Read-Write. Read this file to get errors detected on FME.
93 fails with -EINVAL if input parsing fails or input error code
96 What: /sys/bus/platform/devices/dfl-fme.0/errors/first_error
100 Description: Read-only. Read this file to get the first error detected by
103 What: /sys/bus/platform/devices/dfl-fme.0/errors/next_error
107 Description: Read-only. Read this file to get the second error detected by
110 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/name
114 Description: Read-Only. Read this file to get the name of hwmon device, it
119 'dfl_fme_power' power hwmon device name
122 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_input
126 Description: Read-Only. It returns FPGA device temperature in millidegrees
129 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max
133 Description: Read-Only. It returns hardware threshold1 temperature in
138 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit
142 Description: Read-Only. It returns hardware threshold2 temperature in
146 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_emergency
150 Description: Read-Only. It returns hardware trip threshold temperature in
155 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_alarm
159 Description: Read-only. It returns 1 if temperature is currently at or above
162 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit_alarm
166 Description: Read-only. It returns 1 if temperature is currently at or above
169 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_policy
173 Description: Read-Only. Read this file to get the policy of hardware threshold1
181 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_input
185 Description: Read-Only. It returns current FPGA power consumption in uW.
187 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_max
191 Description: Read-Write. Read this file to get current hardware power
192 threshold1 in uW. If power consumption rises at or above
194 Write this file to set current hardware power threshold1 in uW.
198 -EINVAL if input parsing fails.
200 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_crit
204 Description: Read-Write. Read this file to get current hardware power
205 threshold2 in uW. If power consumption rises at or above
207 Write this file to set current hardware power threshold2 in uW.
211 -EINVAL if input parsing fails.
213 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_max_alarm
217 Description: Read-only. It returns 1 if power consumption is currently at or
220 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_crit_alarm
224 Description: Read-only. It returns 1 if power consumption is currently at or
227 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_xeon_limit
231 Description: Read-Only. It returns power limit for XEON in uW.
233 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_fpga_limit
237 Description: Read-Only. It returns power limit for FPGA in uW.
239 What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/power1_ltr
243 Description: Read-only. Read this file to get current Latency Tolerance