Lines Matching +full:auto +full:- +full:trickle +full:- +full:charging
5 Contact: linux-pm@vger.kernel.org
14 Contact: linux-pm@vger.kernel.org
23 Contact: linux-pm@vger.kernel.org
32 Contact: linux-pm@vger.kernel.org
43 Contact: linux-pm@vger.kernel.org
61 used for discharging batteries, positive values for charging
66 Contact: linux-pm@vger.kernel.org
81 Contact: linux-pm@vger.kernel.org
94 read-only reporting, unless the 'online' state of the supply
101 used for discharging batteries, positive values for charging
106 Contact: linux-pm@vger.kernel.org
124 Contact: linux-pm@vger.kernel.org
128 Maximum TBAT temperature trip-wire value where the supply will
129 notify user-space of the event.
133 Maximum supply temperature trip-wire value where the supply
134 will notify user-space of the event.
136 This is normally used for the charging scenario where
137 user-space needs to know if the temperature has crossed an
139 user that the temperature is critically high, and charging has
148 Contact: linux-pm@vger.kernel.org
153 Minimum TBAT temperature trip-wire value where the supply will
154 notify user-space of the event.
158 Minimum supply temperature trip-wire value where the supply
159 will notify user-space of the event.
161 This is normally used for the charging scenario where user-space
164 temperature level is high, and charging current has been
173 Contact: linux-pm@vger.kernel.org
178 charging.
190 Contact: linux-pm@vger.kernel.org
195 charging.
207 Contact: linux-pm@vger.kernel.org
212 battery, during charging.
224 Contact: linux-pm@vger.kernel.org
241 Contact: linux-pm@vger.kernel.org
253 read-only reporting, unless the 'online' state of the supply
265 Contact: linux-pm@vger.kernel.org
271 Valid values: 0 - 100 (percent)
275 Contact: linux-pm@vger.kernel.org
277 Maximum battery capacity trip-wire value where the supply will
278 notify user-space of the event. This is normally used for the
279 battery discharging scenario where user-space needs to know the
286 Valid values: 0 - 100 (percent)
290 Contact: linux-pm@vger.kernel.org
292 Minimum battery capacity trip-wire value where the supply will
293 notify user-space of the event. This is normally used for the
294 battery discharging scenario where user-space needs to know the
301 Valid values: 0 - 100 (percent)
305 Contact: linux-pm@vger.kernel.org
310 Values close to 0% will be returned after (re-)calibration
317 Valid values: 0 - 100 (percent)
321 Contact: linux-pm@vger.kernel.org
333 Contact: linux-pm@vger.kernel.org
335 Maximum allowable charging current. Used for charge rate
344 Contact: linux-pm@vger.kernel.org
354 Contact: linux-pm@vger.kernel.org
356 Represents a battery percentage level, below which charging will
360 Valid values: 0 - 100 (percent)
364 Contact: linux-pm@vger.kernel.org
366 Represents a battery percentage level, above which charging will
374 Valid values: 0 - 100 (percent)
378 Contact: linux-pm@vger.kernel.org
380 Select the charging algorithm to use for a battery.
385 Quickly charge the battery using fast-charge
387 than standard charging and may lower its lifespan.
388 Trickle:
398 when to start and stop charging. Advanced users
401 The charger reduces its charging rate in order to
404 The charger bypasses the charging path around the
411 "Unknown", "N/A", "Trickle", "Fast", "Standard",
416 Contact: linux-pm@vger.kernel.org
418 Reports the charging current value which is used to determine
419 when the battery is considered full and charging should end.
427 Contact: linux-pm@vger.kernel.org
443 Contact: linux-pm@vger.kernel.org
445 Reports the charging current applied during pre-charging phase
454 Contact: linux-pm@vger.kernel.org
470 Contact: linux-pm@vger.kernel.org
472 Represents the charging status of the battery. Normally this
473 is read-only reporting although for some supplies this can be
474 used to enable/disable charging to the battery.
479 "Unknown", "Charging", "Discharging",
480 "Not charging", "Full"
484 Contact: linux-pm@vger.kernel.org
486 Represents the charging behaviour.
492 auto: Charge normally, respect thresholds
493 inhibit-charge: Do not charge while AC is attached
494 force-discharge: Force discharge while AC is attached
499 Contact: linux-pm@vger.kernel.org
506 "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe",
512 Contact: linux-pm@vger.kernel.org
524 Contact: linux-pm@vger.kernel.org
539 Contact: linux-pm@vger.kernel.org
554 Contact: linux-pm@vger.kernel.org
558 system-level knowledge or user input (e.g. This is part of the
572 Contact: linux-pm@vger.kernel.org
576 system-level knowledge or user input. Use preferably this
586 Contact: linux-pm@vger.kernel.org
590 between online states (e.g. Fixed -> Programmable for a PD_PPS
599 1: Online Fixed - Fixed Voltage Supply
600 2: Online Programmable - Programmable Voltage Supply
605 Contact: linux-pm@vger.kernel.org
608 the supply, for example it can show if USB-PD capable source
611 Access: For power-supplies which consume USB power such
613 the connected USB power source and is Read-Only.
615 For power-supplies which act as a USB power-source such as
624 What: /sys/class/power/ds2760-battery.*/charge_now
632 A userspace daemon can monitor the battery charging logic
636 What: /sys/class/power/ds2760-battery.*/charge_full
645 What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer
651 charger operates in fast-charge mode. When the timer expires
652 the device will terminate fast-charge mode (charging current
657 - 5, 6 or 7 (hours),
658 - 0: disabled.
660 What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer
666 charger operates in fast-charge mode. When the timer expires
667 the device will terminate fast-charge mode (charging current
672 - 4 - 16 (hours), step by 2 (rounded down)
673 - 0: disabled.
675 What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current
680 This entry shows and sets the charging current threshold for
681 entering top-off charging mode. When charging current in fast
683 interrupt and start top-off charging mode.
687 - 100000 - 200000 (microamps), step by 25000 (rounded down)
688 - 200000 - 350000 (microamps), step by 50000 (rounded down)
689 - 0: disabled.
691 What: /sys/class/power_supply/max77693-charger/device/top_off_timer
697 charger operates in top-off charge mode. When the timer expires
698 the device will terminate top-off charge mode (charging current
703 - 0 - 70 (minutes), step by 10 (rounded down)
705 What: /sys/class/power_supply/bq24257-charger/ovp_voltage
710 This entry configures the overvoltage protection feature of bq24257-
717 - 6000000, 6500000, 7000000, 8000000, 9000000, 9500000, 10000000,
720 What: /sys/class/power_supply/bq24257-charger/in_dpm_voltage
726 bq24257-type charger devices. Once the supply drops to the configured
733 - 4200000, 4280000, 4360000, 4440000, 4520000, 4600000, 4680000,
736 What: /sys/class/power_supply/bq24257-charger/high_impedance_enable
741 This entry allows enabling the high-impedance mode of bq24257-type
748 - 1: enabled
749 - 0: disabled
751 What: /sys/class/power_supply/bq24257-charger/sysoff_enable
756 This entry allows enabling the sysoff mode of bq24257-type charger
764 - 1: enabled
765 - 0: disabled
769 Contact: linux-pm@vger.kernel.org
780 Contact: linux-pm@vger.kernel.org
786 Valid values: 1-12
790 Contact: linux-pm@vger.kernel.org
795 Valid values: 1-31