History log of /titanic_51/usr/src/uts/sun4v/vnet/Makefile (Results 1 – 4 of 4)
Revision Date Author Comments
# 7014882c 22-Jul-2012 Richard Lowe <richlowe@richlowe.net>

2933 compiler warning gags need better granularity
Reviewed by: Eric Schrock <eric.schrock@delphix.com>
Approved by: Garrett D'Amore <garrett@damore.org>


# bb25c06c 06-Nov-2006 jg <none@none>

6470037 remove global disable of some potentially useful lint warnings from the kernel lint build


# d10e4ef2 10-Jul-2006 narayan <none@none>

6412648 VIO service drivers auto-unload after some time
6413569 Possible memory leaks needs to be investigated.
6423722 vds should use finer-grained locking for better performance
6429738 LDom panics

6412648 VIO service drivers auto-unload after some time
6413569 Possible memory leaks needs to be investigated.
6423722 vds should use finer-grained locking for better performance
6429738 LDom panics using a destroyed ldc
6431111 LDOM manager should use P_FAULTED state for cpu instead of P_OFFLINE/
6431300 can not enter '~' character on a ldom's console
6431458 vDisk drivers need to handle read/write requests asynchronously
6437436 ldc read/write operations are serialized due to a common lock
6437766 vDisk VTOC should handle the timestamp field
6440543 vSwitch/vNet should use aligned IP frame headers
6440553 vNet/vSwitch should reuse previously allocated mblks
6442270 vDisk server should set FREAD and FWRITE mode when calling ldi_ioctl
6442851 Remove VLDC max write_pa limit
6442973 vntsd dumps core with assertion failure message
6443193 vDisk client incorrectly implements DKIOCSGEOM ioctl
6443198 vDisk client incorrectly caches new VTOC on DKIOCSVTOC ioctl
6444392 vswitch/vnet should set end_idx to -1 for increased performance

show more ...


# 1ae08745 17-May-2006 heppo <none@none>

FWARC 2005/633 Project Q Logial Domaining Umbrella
FWARC 2005/739 sun4v channels
FWARC 2006/055 Domain Services
FWARC 2006/072 sun4v virtual devices machine description data
FWARC 2006/074 sun4v inte

FWARC 2005/633 Project Q Logial Domaining Umbrella
FWARC 2005/739 sun4v channels
FWARC 2006/055 Domain Services
FWARC 2006/072 sun4v virtual devices machine description data
FWARC 2006/074 sun4v interrupt cookies
FWARC 2006/075 Channel devices, Virtual Disk client and server bindings
FWARC 2006/076 Virtual Network Client and switch Bindings
FWARC 2006/081 Virtual Logical Domain Channel (vldc) Bindings
FWARC 2006/086 LDOM variables
FWARC 2006/105 LDOM support for NCP
FWARC 2006/110 Domain Services MD node and other misc properties
FWARC 2006/117 Virtual Console Concentrator Bindings
FWARC 2006/135 sun4v channel console packets
FWARC 2006/140 sun4v channels transport protocol
FWARC 2006/141 FMA Domain Services
FWARC 2006/174 NCS HV Update
FWARC 2006/184 sun4v channels shared memory
FWARC 2006/195 Virtual IO Communication Protocol
PSARC 2006/152 Logical Domain Channels Transport API
6272074 Need interface to determine execution unit sharing.
6354556 Add machine description kernel framework support
6391870 LDoms v1.0 Solaris Changes

show more ...