6464148 rename in-band descriptor in vnet to use the right prefix.6496374 vsw: "tunrnstile_block: unowned mutex" panic on a diskless-clients test bed6501505 Assertion panic in vcc on ldom creation.
6464148 rename in-band descriptor in vnet to use the right prefix.6496374 vsw: "tunrnstile_block: unowned mutex" panic on a diskless-clients test bed6501505 Assertion panic in vcc on ldom creation.6501588 Adding a 2nd VDS to domain0 renders the 1st VDS unreachable, plus false failures on VDS1 disk6503173 a couple of minor memory leaks during detach() in vnet6505181 handshake retry counts in vnet and vsw do not match
show more ...
FWARC/2006/473 sun4v guest state API updateFWARC/2006/542 Guest State Supported CIF6383225 Solaris does not send guest state to alom
6491586 Reduce use of va_to_pa
6485604 kssl hangs under SPECweb2005-banking
6418780 vswitch needs to be able to process updates to its MD node6492078 vds does not handle ldc_close failures6492423 vSwitch multi-ring code hangs when queue thread not started6492705 vsw warni
6418780 vswitch needs to be able to process updates to its MD node6492078 vds does not handle ldc_close failures6492423 vSwitch multi-ring code hangs when queue thread not started6492705 vsw warning messages should identify device instance number6492706 changing switching mode in one vsw instance should not affect other instance6493179 Guests fail disk identification on net install if only backup partition exists.
FWARC/2006/175 MD definition for N2 CWQFWARC/2006/201 sun4v error handling updateFWARC/2006/425 NCS HV API Update 2FWARC/2006/429 Niagara2 Perf Regs HV APIFWARC/2006/474 pci io hv iommu attribute
FWARC/2006/175 MD definition for N2 CWQFWARC/2006/201 sun4v error handling updateFWARC/2006/425 NCS HV API Update 2FWARC/2006/429 Niagara2 Perf Regs HV APIFWARC/2006/474 pci io hv iommu attributes updateFWARC/2006/481 Niagara-2 Random Number Generator APIFWARC/2006/524 Niagara2 Network Interface Unit Hypervisor APIFWARC/2006/556 NIU/SIU Device Tree Bindings and Machine Description DefinitionsFWARC/2006/567 Niagara Crypto & RNG compatible property updatePSARC/2006/459 Huron 1u/2u Platform SupportPSARC/2006/520 Niagara 2 Random Number GeneratorPSARC/2006/521 Niagara 2 Cryptographic ProviderPSARC/2006/645 Niagara II NIU 10Gbit Ethernet Driver6477049 ON support for UltraSPARC-T2 processor6375797 Add support for SUN4V IOMMU extensions6480942 Crypto support for UltraSPARC-T2 processor6480959 NIU support for UltraSPARC-T2 processor6483040 ON platform support for Huron (SPARC-Enterprise-T5120 & SPARC-Enterprise-T5220)
6482166 vntsd dumps core and all console connections get killed.6490897 vntsd fails on default control domain6492688 ldc panic under load
6485548 Can not create zpool on guest domain with an entire vdisk6486746 cnex timeouts during intr redistribution when doing cpu DR6488547 Kaio accesses of block size greater than 64K fail on guest
6485548 Can not create zpool on guest domain with an entire vdisk6486746 cnex timeouts during intr redistribution when doing cpu DR6488547 Kaio accesses of block size greater than 64K fail on guest's virtual disks6488812 vdc driver should define internal macro instead of SDUNIT/SDPART
6402328 Add multi-pil and unlimited softint support for SPARC
6464240 back out 6436930
6475901 vnet fails to establish connection with vswitch after service domain reboot6476056 vldc incorrectly marks port in RESET state6476337 call to ldc_close blocks for a very long time
6458676 memory leak with 12 hours all_solaris_tests.6460802 vdc does not handle ldc_write failures appropriately6462669 VDC bind failure messages under stress in an ldom.6463753 panic[cpu0]/thread
6458676 memory leak with 12 hours all_solaris_tests.6460802 vdc does not handle ldc_write failures appropriately6462669 VDC bind failure messages under stress in an ldom.6463753 panic[cpu0]/thread=2a100207cc0: kernel heap corruption detected6469548 Domain Services module should not claim every DS port in the MD6469890 LDC clients fail to handshake reliably following a channel reset6469900 LDOM domain0 runs out of freemem during extended runs.6470870 pcp_init() returns error right after boot6471712 vntsd cannot be disabled via svcadm unless issued twice.
6405380 LDoms vSwitch needs to be modified to support network interfaces with multiple DMA channels6442123 CDDL missing in usr/src/uts/sun4v/sys/mmu.h6444620 Consoles in a group should not logout u
6405380 LDoms vSwitch needs to be modified to support network interfaces with multiple DMA channels6442123 CDDL missing in usr/src/uts/sun4v/sys/mmu.h6444620 Consoles in a group should not logout user when switched to another console.6451435 vntsd should be checked by lint during a nightly build6461268 Ctrl-S hangs ldoms guest console.6461648 vds should handle requests for absolute disk offsets per FWARC/2006/1956464824 vnet panics due to ldc_mem_alloc_handle(0x1f) error allocating table memory6465197 Console connections fail on an active ldom.6467567 panic[cpu0]/thread=2a10045fcc0: recursive mutex_enter6469790 ldc call to vmem_free uses incorrect size
6461649 vldc driver sets incorrect default MTU for streaming mode channel (add missing file)
6430578 PCI Memory map in fails
6419154 libpcp pcp_init routine should accept service names6428416 CPUs greater than NCPU are stopped too early in boot6436930 qcn drv needs to handle EWOULDBLOCK returned by hv_cnputchar6437727 v
6419154 libpcp pcp_init routine should accept service names6428416 CPUs greater than NCPU are stopped too early in boot6436930 qcn drv needs to handle EWOULDBLOCK returned by hv_cnputchar6437727 vDisk should support EFI labels6437738 vDisk should support devid6441930 fillsysinfo should cap max sun4v queue size to kernel limits6441933 The broken MD detection code should be improved6445825 domaining_enabled variable does not tell the whole story6449959 vDisk DKIOCSETWCE/DKIOCGETWCE ioctls are not correctly implemented6451118 Elevate libpcp from a platform lib to a sun4v lib6451490 ldc_chkq incorrectly returns queue empty when data is available on streaming mode channel6456875 VIO drivers should use LDC shared memory for better performance6456880 LDC link layer fails to clear interrupt state properly6456928 drd service is not enabled if installed through an upgrade6457162 vswitch needs to cope with dropped pkts when talking to obp6457166 vswitch calculating bounded range of descriptors incorrectly
FWARC/2006/425 NCS HV API Update 26425909 crypto (mau) interrupt state machine opens window for lost interrupts
6449956 panic[cpu28]/thread=2a101499cc0: mutex_enter: adaptive at high PIL, lp=3004ff682c8 owner=2a101499cc
6432376 vds and vdc don't negotiate max transfer size supported correctly6432416 vds should support raw as well as block devices.6434543 vdc error messages could be more informative6447559 vswitch
6432376 vds and vdc don't negotiate max transfer size supported correctly6432416 vds should support raw as well as block devices.6434543 vdc error messages could be more informative6447559 vswitch should take advantage of multiple unicast address support6448482 Some LDC link layer APIs do not match specification6448730 drctl panics being unloaded by moduninstall daemon
6412648 VIO service drivers auto-unload after some time6413569 Possible memory leaks needs to be investigated.6423722 vds should use finer-grained locking for better performance6429738 LDom panics
6412648 VIO service drivers auto-unload after some time6413569 Possible memory leaks needs to be investigated.6423722 vds should use finer-grained locking for better performance6429738 LDom panics using a destroyed ldc6431111 LDOM manager should use P_FAULTED state for cpu instead of P_OFFLINE/6431300 can not enter '~' character on a ldom's console6431458 vDisk drivers need to handle read/write requests asynchronously6437436 ldc read/write operations are serialized due to a common lock6437766 vDisk VTOC should handle the timestamp field6440543 vSwitch/vNet should use aligned IP frame headers6440553 vNet/vSwitch should reuse previously allocated mblks6442270 vDisk server should set FREAD and FWRITE mode when calling ldi_ioctl6442851 Remove VLDC max write_pa limit6442973 vntsd dumps core with assertion failure message6443193 vDisk client incorrectly implements DKIOCSGEOM ioctl6443198 vDisk client incorrectly caches new VTOC on DKIOCSVTOC ioctl6444392 vswitch/vnet should set end_idx to -1 for increased performance
PSARC/2006/248 Nemo MAC-Type Plugin ArchitecturePSARC/2006/249 Nemo Changes for Binary Compatibility6226635 MAC stats interface could cause problems with binary compatibility6242059 nemo drivers m
PSARC/2006/248 Nemo MAC-Type Plugin ArchitecturePSARC/2006/249 Nemo Changes for Binary Compatibility6226635 MAC stats interface could cause problems with binary compatibility6242059 nemo drivers must not know the size of the mac_t structure6384371 GLDv3 only supports Ethernet6401695 xge uses a receive ring even though it doesn't do blanking6432471 panic in dls_close() if DL_BIND_REQ previously failed
6425012 LDoms CPU DR should be enhanced to interact with RCM
6261101 VAC alias handling code should be compiled out for sun4v
FWARC/2006/323 console read/write hv APIs6405226 qcn driver should use the CONS_READ and CONS_WRITE hypervisor APIs6431976 lock window allows console interrupts to be lost
6373298 Integrate support for MMU context ID domains
123456789