xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4V.po (revision 9dd0f810214fdc8e1af881a9a5c4b6927629ff9e)
1#
2# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: SUN4V-8000-1S
30# keys: fault.cpu.ultraSPARC-T1.ireg
31#
32msgid "SUN4V-8000-1S.type"
33msgstr "Fault"
34msgid "SUN4V-8000-1S.severity"
35msgstr "Minor"
36msgid "SUN4V-8000-1S.description"
37msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
38msgid "SUN4V-8000-1S.response"
39msgstr "The fault manager will attempt to remove the affected CPU from service."
40msgid "SUN4V-8000-1S.impact"
41msgstr "System performance may be affected."
42msgid "SUN4V-8000-1S.action"
43msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
44#
45# code: SUN4V-8000-2A
46# keys: fault.cpu.ultraSPARC-T1.freg
47#
48msgid "SUN4V-8000-2A.type"
49msgstr "Fault"
50msgid "SUN4V-8000-2A.severity"
51msgstr "Major"
52msgid "SUN4V-8000-2A.description"
53msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
54msgid "SUN4V-8000-2A.response"
55msgstr "None"
56msgid "SUN4V-8000-2A.impact"
57msgstr "System performance may be affected."
58msgid "SUN4V-8000-2A.action"
59msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
60#
61# code: SUN4V-8000-3P
62# keys: fault.cpu.ultraSPARC-T1.itlb
63#
64msgid "SUN4V-8000-3P.type"
65msgstr "Fault"
66msgid "SUN4V-8000-3P.severity"
67msgstr "Minor"
68msgid "SUN4V-8000-3P.description"
69msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
70msgid "SUN4V-8000-3P.response"
71msgstr "The fault manager will attempt to remove the affected CPU from service."
72msgid "SUN4V-8000-3P.impact"
73msgstr "System performance may be affected.\n"
74msgid "SUN4V-8000-3P.action"
75msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
76#
77# code: SUN4V-8000-4D
78# keys: fault.cpu.ultraSPARC-T1.dtlb
79#
80msgid "SUN4V-8000-4D.type"
81msgstr "Fault"
82msgid "SUN4V-8000-4D.severity"
83msgstr "Minor"
84msgid "SUN4V-8000-4D.description"
85msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
86msgid "SUN4V-8000-4D.response"
87msgstr "The fault manager will attempt to remove the affected CPU from service."
88msgid "SUN4V-8000-4D.impact"
89msgstr "System performance may be affected.\n"
90msgid "SUN4V-8000-4D.action"
91msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
92#
93# code: SUN4V-8000-5H
94# keys: fault.cpu.ultraSPARC-T1.icache
95#
96msgid "SUN4V-8000-5H.type"
97msgstr "Fault"
98msgid "SUN4V-8000-5H.severity"
99msgstr "Minor"
100msgid "SUN4V-8000-5H.description"
101msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
102msgid "SUN4V-8000-5H.response"
103msgstr "The fault manager will attempt to remove the affected CPU from service."
104msgid "SUN4V-8000-5H.impact"
105msgstr "System performance may be affected.\n"
106msgid "SUN4V-8000-5H.action"
107msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
108#
109# code: SUN4V-8000-63
110# keys: fault.cpu.ultraSPARC-T1.dcache
111#
112msgid "SUN4V-8000-63.type"
113msgstr "Fault"
114msgid "SUN4V-8000-63.severity"
115msgstr "Minor"
116msgid "SUN4V-8000-63.description"
117msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
118msgid "SUN4V-8000-63.response"
119msgstr "The fault manager will attempt to remove the affected CPU from service."
120msgid "SUN4V-8000-63.impact"
121msgstr "System performance may be affected.\n"
122msgid "SUN4V-8000-63.action"
123msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
124#
125# code: SUN4V-8000-7Y
126# keys: fault.cpu.ultraSPARC-T1.mau
127#
128msgid "SUN4V-8000-7Y.type"
129msgstr "Fault"
130msgid "SUN4V-8000-7Y.severity"
131msgstr "Major"
132msgid "SUN4V-8000-7Y.description"
133msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
134msgid "SUN4V-8000-7Y.response"
135msgstr "None"
136msgid "SUN4V-8000-7Y.impact"
137msgstr "System performance may be affected.\n"
138msgid "SUN4V-8000-7Y.action"
139msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
140#
141# code: SUN4V-8000-8Q
142# keys: fault.cpu.ultraSPARC-T1.l2cachedata
143#
144msgid "SUN4V-8000-8Q.type"
145msgstr "Fault"
146msgid "SUN4V-8000-8Q.severity"
147msgstr "Critical"
148msgid "SUN4V-8000-8Q.description"
149msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
150msgid "SUN4V-8000-8Q.response"
151msgstr "None"
152msgid "SUN4V-8000-8Q.impact"
153msgstr "System performance may be affected.\n"
154msgid "SUN4V-8000-8Q.action"
155msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
156#
157# code: SUN4V-8000-9C
158# keys: fault.cpu.ultraSPARC-T1.l2cachetag
159#
160msgid "SUN4V-8000-9C.type"
161msgstr "Fault"
162msgid "SUN4V-8000-9C.severity"
163msgstr "Critical"
164msgid "SUN4V-8000-9C.description"
165msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
166msgid "SUN4V-8000-9C.response"
167msgstr "None"
168msgid "SUN4V-8000-9C.impact"
169msgstr "System performance may be affected.\n"
170msgid "SUN4V-8000-9C.action"
171msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
172#
173# code: SUN4V-8000-AR
174# keys: fault.cpu.ultraSPARC-T1.l2cachectl
175#
176msgid "SUN4V-8000-AR.type"
177msgstr "Fault"
178msgid "SUN4V-8000-AR.severity"
179msgstr "Critical"
180msgid "SUN4V-8000-AR.description"
181msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
182msgid "SUN4V-8000-AR.response"
183msgstr "None"
184msgid "SUN4V-8000-AR.impact"
185msgstr "System performance may be affected.\n"
186msgid "SUN4V-8000-AR.action"
187msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
188#
189# code: SUN4V-8000-C4
190# keys: fault.memory.page
191#
192msgid "SUN4V-8000-C4.type"
193msgstr "Fault"
194msgid "SUN4V-8000-C4.severity"
195msgstr "Minor"
196msgid "SUN4V-8000-C4.description"
197msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
198msgid "SUN4V-8000-C4.response"
199msgstr "An attempt will be made to remove this memory page from service."
200msgid "SUN4V-8000-C4.impact"
201msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
202msgid "SUN4V-8000-C4.action"
203msgstr "No repair action is recommended at this time."
204#
205# code: SUN4V-8000-DX
206# keys: fault.memory.dimm
207#
208msgid "SUN4V-8000-DX.type"
209msgstr "Fault"
210msgid "SUN4V-8000-DX.severity"
211msgstr "Major"
212msgid "SUN4V-8000-DX.description"
213msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
214msgid "SUN4V-8000-DX.response"
215msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
216msgid "SUN4V-8000-DX.impact"
217msgstr "Total system memory capacity will be reduced as pages are retired."
218msgid "SUN4V-8000-DX.action"
219msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
220#
221# code: SUN4V-8000-E2
222# keys: fault.memory.bank
223#
224msgid "SUN4V-8000-E2.type"
225msgstr "Fault"
226msgid "SUN4V-8000-E2.severity"
227msgstr "Critical"
228msgid "SUN4V-8000-E2.description"
229msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
230msgid "SUN4V-8000-E2.response"
231msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
232msgid "SUN4V-8000-E2.impact"
233msgstr "Total system memory capacity will be reduced as pages are retired."
234msgid "SUN4V-8000-E2.action"
235msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."