xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4V.po (revision 40e5e17b3361b3eea56a9723071c406894a20b78)
1#
2# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: SUN4V-8000-1S
30# keys: fault.cpu.ultraSPARC-T1.ireg
31#
32msgid "SUN4V-8000-1S.type"
33msgstr "Fault"
34msgid "SUN4V-8000-1S.severity"
35msgstr "Minor"
36msgid "SUN4V-8000-1S.description"
37msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
38msgid "SUN4V-8000-1S.response"
39msgstr "The fault manager will attempt to remove the affected CPU from service."
40msgid "SUN4V-8000-1S.impact"
41msgstr "System performance may be affected."
42msgid "SUN4V-8000-1S.action"
43msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
44#
45# code: SUN4V-8000-2A
46# keys: fault.cpu.ultraSPARC-T1.freg
47#
48msgid "SUN4V-8000-2A.type"
49msgstr "Fault"
50msgid "SUN4V-8000-2A.severity"
51msgstr "Major"
52msgid "SUN4V-8000-2A.description"
53msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
54msgid "SUN4V-8000-2A.response"
55msgstr "None"
56msgid "SUN4V-8000-2A.impact"
57msgstr "System performance may be affected."
58msgid "SUN4V-8000-2A.action"
59msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
60#
61# code: SUN4V-8000-3P
62# keys: fault.cpu.ultraSPARC-T1.itlb
63#
64msgid "SUN4V-8000-3P.type"
65msgstr "Fault"
66msgid "SUN4V-8000-3P.severity"
67msgstr "Minor"
68msgid "SUN4V-8000-3P.description"
69msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
70msgid "SUN4V-8000-3P.response"
71msgstr "The fault manager will attempt to remove the affected CPU from service."
72msgid "SUN4V-8000-3P.impact"
73msgstr "System performance may be affected.\n"
74msgid "SUN4V-8000-3P.action"
75msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
76#
77# code: SUN4V-8000-4D
78# keys: fault.cpu.ultraSPARC-T1.dtlb
79#
80msgid "SUN4V-8000-4D.type"
81msgstr "Fault"
82msgid "SUN4V-8000-4D.severity"
83msgstr "Minor"
84msgid "SUN4V-8000-4D.description"
85msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
86msgid "SUN4V-8000-4D.response"
87msgstr "The fault manager will attempt to remove the affected CPU from service."
88msgid "SUN4V-8000-4D.impact"
89msgstr "System performance may be affected.\n"
90msgid "SUN4V-8000-4D.action"
91msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
92#
93# code: SUN4V-8000-5H
94# keys: fault.cpu.ultraSPARC-T1.icache
95#
96msgid "SUN4V-8000-5H.type"
97msgstr "Fault"
98msgid "SUN4V-8000-5H.severity"
99msgstr "Minor"
100msgid "SUN4V-8000-5H.description"
101msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
102msgid "SUN4V-8000-5H.response"
103msgstr "The fault manager will attempt to remove the affected CPU from service."
104msgid "SUN4V-8000-5H.impact"
105msgstr "System performance may be affected.\n"
106msgid "SUN4V-8000-5H.action"
107msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
108#
109# code: SUN4V-8000-63
110# keys: fault.cpu.ultraSPARC-T1.dcache
111#
112msgid "SUN4V-8000-63.type"
113msgstr "Fault"
114msgid "SUN4V-8000-63.severity"
115msgstr "Minor"
116msgid "SUN4V-8000-63.description"
117msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
118msgid "SUN4V-8000-63.response"
119msgstr "The fault manager will attempt to remove the affected CPU from service."
120msgid "SUN4V-8000-63.impact"
121msgstr "System performance may be affected.\n"
122msgid "SUN4V-8000-63.action"
123msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
124#
125# code: SUN4V-8000-7Y
126# keys: fault.cpu.ultraSPARC-T1.mau
127#
128msgid "SUN4V-8000-7Y.type"
129msgstr "Fault"
130msgid "SUN4V-8000-7Y.severity"
131msgstr "Major"
132msgid "SUN4V-8000-7Y.description"
133msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
134msgid "SUN4V-8000-7Y.response"
135msgstr "None"
136msgid "SUN4V-8000-7Y.impact"
137msgstr "System performance may be affected.\n"
138msgid "SUN4V-8000-7Y.action"
139msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
140#
141# code: SUN4V-8000-8Q
142# keys: fault.cpu.ultraSPARC-T1.l2cachedata
143#
144msgid "SUN4V-8000-8Q.type"
145msgstr "Fault"
146msgid "SUN4V-8000-8Q.severity"
147msgstr "Critical"
148msgid "SUN4V-8000-8Q.description"
149msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
150msgid "SUN4V-8000-8Q.response"
151msgstr "None"
152msgid "SUN4V-8000-8Q.impact"
153msgstr "System performance may be affected.\n"
154msgid "SUN4V-8000-8Q.action"
155msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
156#
157# code: SUN4V-8000-9C
158# keys: fault.cpu.ultraSPARC-T1.l2cachetag
159#
160msgid "SUN4V-8000-9C.type"
161msgstr "Fault"
162msgid "SUN4V-8000-9C.severity"
163msgstr "Critical"
164msgid "SUN4V-8000-9C.description"
165msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
166msgid "SUN4V-8000-9C.response"
167msgstr "None"
168msgid "SUN4V-8000-9C.impact"
169msgstr "System performance may be affected.\n"
170msgid "SUN4V-8000-9C.action"
171msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
172#
173# code: SUN4V-8000-AR
174# keys: fault.cpu.ultraSPARC-T1.l2cachectl
175#
176msgid "SUN4V-8000-AR.type"
177msgstr "Fault"
178msgid "SUN4V-8000-AR.severity"
179msgstr "Critical"
180msgid "SUN4V-8000-AR.description"
181msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
182msgid "SUN4V-8000-AR.response"
183msgstr "None"
184msgid "SUN4V-8000-AR.impact"
185msgstr "System performance may be affected.\n"
186msgid "SUN4V-8000-AR.action"
187msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
188#
189# code: SUN4V-8000-C4
190# keys: fault.memory.page
191#
192msgid "SUN4V-8000-C4.type"
193msgstr "Fault"
194msgid "SUN4V-8000-C4.severity"
195msgstr "Minor"
196msgid "SUN4V-8000-C4.description"
197msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
198msgid "SUN4V-8000-C4.response"
199msgstr "An attempt will be made to remove this memory page from service."
200msgid "SUN4V-8000-C4.impact"
201msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
202msgid "SUN4V-8000-C4.action"
203msgstr "No repair action is recommended at this time."
204#
205# code: SUN4V-8000-DX
206# keys: fault.memory.dimm
207#
208msgid "SUN4V-8000-DX.type"
209msgstr "Fault"
210msgid "SUN4V-8000-DX.severity"
211msgstr "Major"
212msgid "SUN4V-8000-DX.description"
213msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
214msgid "SUN4V-8000-DX.response"
215msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
216msgid "SUN4V-8000-DX.impact"
217msgstr "Total system memory capacity will be reduced as pages are retired."
218msgid "SUN4V-8000-DX.action"
219msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
220#
221# code: SUN4V-8000-E2
222# keys: fault.memory.bank
223#
224msgid "SUN4V-8000-E2.type"
225msgstr "Fault"
226msgid "SUN4V-8000-E2.severity"
227msgstr "Critical"
228msgid "SUN4V-8000-E2.description"
229msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
230msgid "SUN4V-8000-E2.response"
231msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
232msgid "SUN4V-8000-E2.impact"
233msgstr "Total system memory capacity will be reduced as pages are retired."
234msgid "SUN4V-8000-E2.action"
235msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
236#
237# code: SUN4V-8000-FJ
238# keys: fault.memory.link-c
239#
240msgid "SUN4V-8000-FJ.type"
241msgstr "Fault"
242msgid "SUN4V-8000-FJ.severity"
243msgstr "Major"
244msgid "SUN4V-8000-FJ.description"
245msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
246msgid "SUN4V-8000-FJ.response"
247msgstr "No automated response.\n"
248msgid "SUN4V-8000-FJ.impact"
249msgstr "System performance may be impacted.\n"
250msgid "SUN4V-8000-FJ.action"
251msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
252#
253# code: SUN4V-8000-GE
254# keys: fault.cpu.ultraSPARC-T2.ireg
255#
256msgid "SUN4V-8000-GE.type"
257msgstr "Fault"
258msgid "SUN4V-8000-GE.severity"
259msgstr "Minor"
260msgid "SUN4V-8000-GE.description"
261msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
262msgid "SUN4V-8000-GE.response"
263msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
264msgid "SUN4V-8000-GE.impact"
265msgstr "System performance may be affected. \n"
266msgid "SUN4V-8000-GE.action"
267msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
268#
269# code: SUN4V-8000-HP
270# keys: fault.cpu.ultraSPARC-T2.freg
271#
272msgid "SUN4V-8000-HP.type"
273msgstr "Fault"
274msgid "SUN4V-8000-HP.severity"
275msgstr "Minor"
276msgid "SUN4V-8000-HP.description"
277msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
278msgid "SUN4V-8000-HP.response"
279msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
280msgid "SUN4V-8000-HP.impact"
281msgstr "System performance may be affected. \n"
282msgid "SUN4V-8000-HP.action"
283msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
284#
285# code: SUN4V-8000-JA
286# keys: fault.cpu.ultraSPARC-T2.misc_reg
287#
288msgid "SUN4V-8000-JA.type"
289msgstr "Fault"
290msgid "SUN4V-8000-JA.severity"
291msgstr "Minor"
292msgid "SUN4V-8000-JA.description"
293msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
294msgid "SUN4V-8000-JA.response"
295msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
296msgid "SUN4V-8000-JA.impact"
297msgstr "System performance may be affected. \n"
298msgid "SUN4V-8000-JA.action"
299msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
300#
301# code: SUN4V-8000-KS
302# keys: fault.cpu.ultraSPARC-T2.itlb
303#
304msgid "SUN4V-8000-KS.type"
305msgstr "Fault"
306msgid "SUN4V-8000-KS.severity"
307msgstr "Major"
308msgid "SUN4V-8000-KS.description"
309msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
310msgid "SUN4V-8000-KS.response"
311msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
312msgid "SUN4V-8000-KS.impact"
313msgstr "System performance is likely to be affected. \n"
314msgid "SUN4V-8000-KS.action"
315msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
316#
317# code: SUN4V-8000-L5
318# keys: fault.cpu.ultraSPARC-T2.dtlb
319#
320msgid "SUN4V-8000-L5.type"
321msgstr "Fault"
322msgid "SUN4V-8000-L5.severity"
323msgstr "Major"
324msgid "SUN4V-8000-L5.description"
325msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
326msgid "SUN4V-8000-L5.response"
327msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
328msgid "SUN4V-8000-L5.impact"
329msgstr "System performance is likely to be affected. \n"
330msgid "SUN4V-8000-L5.action"
331msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
332#
333# code: SUN4V-8000-MY
334# keys: fault.cpu.ultraSPARC-T2.icache
335#
336msgid "SUN4V-8000-MY.type"
337msgstr "Fault"
338msgid "SUN4V-8000-MY.severity"
339msgstr "Major"
340msgid "SUN4V-8000-MY.description"
341msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
342msgid "SUN4V-8000-MY.response"
343msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
344msgid "SUN4V-8000-MY.impact"
345msgstr "System performance is likely to be affected. \n"
346msgid "SUN4V-8000-MY.action"
347msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
348#
349# code: SUN4V-8000-N3
350# keys: fault.cpu.ultraSPARC-T2.dcache
351#
352msgid "SUN4V-8000-N3.type"
353msgstr "Fault"
354msgid "SUN4V-8000-N3.severity"
355msgstr "Major"
356msgid "SUN4V-8000-N3.description"
357msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
358msgid "SUN4V-8000-N3.response"
359msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
360msgid "SUN4V-8000-N3.impact"
361msgstr "System performance is likely to be affected. \n"
362msgid "SUN4V-8000-N3.action"
363msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
364#
365# code: SUN4V-8000-PH
366# keys: fault.cpu.ultraSPARC-T2.mau
367#
368msgid "SUN4V-8000-PH.type"
369msgstr "Fault"
370msgid "SUN4V-8000-PH.severity"
371msgstr "Major"
372msgid "SUN4V-8000-PH.description"
373msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
374msgid "SUN4V-8000-PH.response"
375msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
376msgid "SUN4V-8000-PH.impact"
377msgstr "System performance is likely to be affected. \n"
378msgid "SUN4V-8000-PH.action"
379msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
380#
381# code: SUN4V-8000-QD
382# keys: fault.cpu.ultraSPARC-T2.l2data-c
383#
384msgid "SUN4V-8000-QD.type"
385msgstr "Fault"
386msgid "SUN4V-8000-QD.severity"
387msgstr "Critical"
388msgid "SUN4V-8000-QD.description"
389msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
390msgid "SUN4V-8000-QD.response"
391msgstr "No automated response.\n"
392msgid "SUN4V-8000-QD.impact"
393msgstr "System performance is likely to be affected. \n"
394msgid "SUN4V-8000-QD.action"
395msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
396#
397# code: SUN4V-8000-R4
398# keys: fault.cpu.ultraSPARC-T2.l2cachetag
399#
400msgid "SUN4V-8000-R4.type"
401msgstr "Fault"
402msgid "SUN4V-8000-R4.severity"
403msgstr "Critical"
404msgid "SUN4V-8000-R4.description"
405msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
406msgid "SUN4V-8000-R4.response"
407msgstr "No automated response.\n"
408msgid "SUN4V-8000-R4.impact"
409msgstr "System performance is likely to be affected. \n"
410msgid "SUN4V-8000-R4.action"
411msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
412#
413# code: SUN4V-8000-SR
414# keys: fault.cpu.ultraSPARC-T2.l2cachectl
415#
416msgid "SUN4V-8000-SR.type"
417msgstr "Fault"
418msgid "SUN4V-8000-SR.severity"
419msgstr "Critical"
420msgid "SUN4V-8000-SR.description"
421msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
422msgid "SUN4V-8000-SR.response"
423msgstr "No automated response.\n"
424msgid "SUN4V-8000-SR.impact"
425msgstr "System performance is likely to be affected. System may be unstable.\n"
426msgid "SUN4V-8000-SR.action"
427msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
428#
429# code: SUN4V-8000-TC
430# keys: fault.memory.link-u
431#
432msgid "SUN4V-8000-TC.type"
433msgstr "Fault"
434msgid "SUN4V-8000-TC.severity"
435msgstr "Critical"
436msgid "SUN4V-8000-TC.description"
437msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
438msgid "SUN4V-8000-TC.response"
439msgstr "No automated response.\n"
440msgid "SUN4V-8000-TC.impact"
441msgstr "System performance may be impacted.\n"
442msgid "SUN4V-8000-TC.action"
443msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
444#
445# code: SUN4V-8000-UQ
446# keys: fault.cpu.ultraSPARC-T2.l2data-u
447#
448msgid "SUN4V-8000-UQ.type"
449msgstr "Fault"
450msgid "SUN4V-8000-UQ.severity"
451msgstr "Critical"
452msgid "SUN4V-8000-UQ.description"
453msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
454msgid "SUN4V-8000-UQ.response"
455msgstr "No automated response.\n"
456msgid "SUN4V-8000-UQ.impact"
457msgstr "System performance is likely to be affected. \n"
458msgid "SUN4V-8000-UQ.action"
459msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
460#
461# code: SUN4V-8000-VE
462# keys: fault.cpu.ultraSPARC-T1.l2data-c
463#
464msgid "SUN4V-8000-VE.type"
465msgstr "Fault"
466msgid "SUN4V-8000-VE.severity"
467msgstr "Critical"
468msgid "SUN4V-8000-VE.description"
469msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
470msgid "SUN4V-8000-VE.response"
471msgstr "No automated response.\n"
472msgid "SUN4V-8000-VE.impact"
473msgstr "System performance is likely to be affected. \n"
474msgid "SUN4V-8000-VE.action"
475msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
476#
477# code: SUN4V-8000-WJ
478# keys: fault.cpu.ultraSPARC-T1.l2data-u
479#
480msgid "SUN4V-8000-WJ.type"
481msgstr "Fault"
482msgid "SUN4V-8000-WJ.severity"
483msgstr "Critical"
484msgid "SUN4V-8000-WJ.description"
485msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
486msgid "SUN4V-8000-WJ.response"
487msgstr "No automated response.\n"
488msgid "SUN4V-8000-WJ.impact"
489msgstr "System performance is likely to be affected. \n"
490msgid "SUN4V-8000-WJ.action"
491msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
492#
493# code: SUN4V-8000-X2
494# keys: fault.memory.datapath
495#
496msgid "SUN4V-8000-X2.type"
497msgstr "Fault"
498msgid "SUN4V-8000-X2.severity"
499msgstr "Major"
500msgid "SUN4V-8000-X2.description"
501msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
502msgid "SUN4V-8000-X2.response"
503msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
504msgid "SUN4V-8000-X2.impact"
505msgstr "System performance and stability may be affected. \n"
506msgid "SUN4V-8000-X2.action"
507msgstr "Contact your service provider for further diagnosis.\n"
508#
509# code: SUN4V-8000-YX
510# keys: fault.io.n2.ncu
511#
512msgid "SUN4V-8000-YX.type"
513msgstr "Fault"
514msgid "SUN4V-8000-YX.severity"
515msgstr "Critical"
516msgid "SUN4V-8000-YX.description"
517msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
518msgid "SUN4V-8000-YX.response"
519msgstr "One or more device instances may be disabled\n"
520msgid "SUN4V-8000-YX.impact"
521msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
522msgid "SUN4V-8000-YX.action"
523msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
524#
525# code: SUN4V-8001-02
526# keys: fault.io.n2.dmu
527#
528msgid "SUN4V-8001-02.type"
529msgstr "Fault"
530msgid "SUN4V-8001-02.severity"
531msgstr "Critical"
532msgid "SUN4V-8001-02.description"
533msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
534msgid "SUN4V-8001-02.response"
535msgstr "One or more device instances may be disabled\n"
536msgid "SUN4V-8001-02.impact"
537msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
538msgid "SUN4V-8001-02.action"
539msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
540#
541# code: SUN4V-8001-1X
542# keys: fault.io.n2.niu
543#
544msgid "SUN4V-8001-1X.type"
545msgstr "Fault"
546msgid "SUN4V-8001-1X.severity"
547msgstr "Critical"
548msgid "SUN4V-8001-1X.description"
549msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
550msgid "SUN4V-8001-1X.response"
551msgstr "One or more device instances may be disabled\n"
552msgid "SUN4V-8001-1X.impact"
553msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
554msgid "SUN4V-8001-1X.action"
555msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
556#
557# code: SUN4V-8001-2E
558# keys: fault.io.n2.siu
559#
560msgid "SUN4V-8001-2E.type"
561msgstr "Fault"
562msgid "SUN4V-8001-2E.severity"
563msgstr "Critical"
564msgid "SUN4V-8001-2E.description"
565msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
566msgid "SUN4V-8001-2E.response"
567msgstr "One or more device instances may be disabled\n"
568msgid "SUN4V-8001-2E.impact"
569msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
570msgid "SUN4V-8001-2E.action"
571msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
572#
573# code: SUN4V-8001-3J
574# keys: fault.io.n2.soc
575#
576msgid "SUN4V-8001-3J.type"
577msgstr "Fault"
578msgid "SUN4V-8001-3J.severity"
579msgstr "Critical"
580msgid "SUN4V-8001-3J.description"
581msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
582msgid "SUN4V-8001-3J.response"
583msgstr "One or more device instances may be disabled\n"
584msgid "SUN4V-8001-3J.impact"
585msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
586msgid "SUN4V-8001-3J.action"
587msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
588#
589# code: SUN4V-8001-4C
590# keys: fault.io.n2.crossbar
591#
592msgid "SUN4V-8001-4C.type"
593msgstr "Fault"
594msgid "SUN4V-8001-4C.severity"
595msgstr "Critical"
596msgid "SUN4V-8001-4C.description"
597msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
598msgid "SUN4V-8001-4C.response"
599msgstr "One or more device instances may be disabled\n"
600msgid "SUN4V-8001-4C.impact"
601msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
602msgid "SUN4V-8001-4C.action"
603msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
604