xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4U.po (revision 3db86aab554edbb4244c8d1a1c90f152eee768af)
1#
2# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#ident	"%Z%%M%	%I%	%E% SMI"
25#
26# DO NOT EDIT -- this file is generated by the Event Registry.
27#
28#
29# code: SUN4U-8000-1A
30# keys: fault.memory.page
31#
32msgid "SUN4U-8000-1A.type"
33msgstr "Fault"
34msgid "SUN4U-8000-1A.severity"
35msgstr "Minor"
36msgid "SUN4U-8000-1A.description"
37msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
38msgid "SUN4U-8000-1A.response"
39msgstr "An attempt will be made to remove this memory page from service."
40msgid "SUN4U-8000-1A.impact"
41msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
42msgid "SUN4U-8000-1A.action"
43msgstr "No repair action is recommended at this time."
44#
45# code: SUN4U-8000-2S
46# keys: fault.memory.dimm
47#
48msgid "SUN4U-8000-2S.type"
49msgstr "Fault"
50msgid "SUN4U-8000-2S.severity"
51msgstr "Major"
52msgid "SUN4U-8000-2S.description"
53msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
54msgid "SUN4U-8000-2S.response"
55msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
56msgid "SUN4U-8000-2S.impact"
57msgstr "Total system memory capacity will be reduced as pages are retired."
58msgid "SUN4U-8000-2S.action"
59msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
60#
61# code: SUN4U-8000-35
62# keys: fault.memory.bank
63#
64msgid "SUN4U-8000-35.type"
65msgstr "Fault"
66msgid "SUN4U-8000-35.severity"
67msgstr "Critical"
68msgid "SUN4U-8000-35.description"
69msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
70msgid "SUN4U-8000-35.response"
71msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
72msgid "SUN4U-8000-35.impact"
73msgstr "Total system memory capacity will be reduced as pages are retired."
74msgid "SUN4U-8000-35.action"
75msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
76#
77# code: SUN4U-8000-4Y
78# keys: fault.cpu.ultraSPARC-III.dcache
79#
80msgid "SUN4U-8000-4Y.type"
81msgstr "Fault"
82msgid "SUN4U-8000-4Y.severity"
83msgstr "Major"
84msgid "SUN4U-8000-4Y.description"
85msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
86msgid "SUN4U-8000-4Y.response"
87msgstr "The fault manager will attempt to remove the affected CPU from service."
88msgid "SUN4U-8000-4Y.impact"
89msgstr "System performance may be affected."
90msgid "SUN4U-8000-4Y.action"
91msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
92#
93# code: SUN4U-8000-53
94# keys: fault.cpu.ultraSPARC-III.icache
95#
96msgid "SUN4U-8000-53.type"
97msgstr "Fault"
98msgid "SUN4U-8000-53.severity"
99msgstr "Major"
100msgid "SUN4U-8000-53.description"
101msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
102msgid "SUN4U-8000-53.response"
103msgstr "The fault manager will attempt to remove the affected CPU from service."
104msgid "SUN4U-8000-53.impact"
105msgstr "System performance may be affected."
106msgid "SUN4U-8000-53.action"
107msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
108#
109# code: SUN4U-8000-6H
110# keys: fault.cpu.ultraSPARC-III.l2cachedata
111#
112msgid "SUN4U-8000-6H.type"
113msgstr "Fault"
114msgid "SUN4U-8000-6H.severity"
115msgstr "Major"
116msgid "SUN4U-8000-6H.description"
117msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
118msgid "SUN4U-8000-6H.response"
119msgstr "The fault manager will attempt to remove the affected CPU from service."
120msgid "SUN4U-8000-6H.impact"
121msgstr "System performance may be affected."
122msgid "SUN4U-8000-6H.action"
123msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
124#
125# code: SUN4U-8000-7D
126# keys: fault.cpu.ultraSPARC-III.l2cachetag
127#
128msgid "SUN4U-8000-7D.type"
129msgstr "Fault"
130msgid "SUN4U-8000-7D.severity"
131msgstr "Major"
132msgid "SUN4U-8000-7D.description"
133msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
134msgid "SUN4U-8000-7D.response"
135msgstr "The fault manager will attempt to remove the affected CPU from service."
136msgid "SUN4U-8000-7D.impact"
137msgstr "System performance may be affected."
138msgid "SUN4U-8000-7D.action"
139msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
140#
141# code: SUN4U-8000-84
142# keys: fault.cpu.ultraSPARC-IIIi.dcache
143#
144msgid "SUN4U-8000-84.type"
145msgstr "Fault"
146msgid "SUN4U-8000-84.severity"
147msgstr "Major"
148msgid "SUN4U-8000-84.description"
149msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
150msgid "SUN4U-8000-84.response"
151msgstr "The fault manager will attempt to remove the affected CPU from service."
152msgid "SUN4U-8000-84.impact"
153msgstr "System performance system may be affected."
154msgid "SUN4U-8000-84.action"
155msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
156#
157# code: SUN4U-8000-9R
158# keys: fault.cpu.ultraSPARC-IIIi.icache
159#
160msgid "SUN4U-8000-9R.type"
161msgstr "Fault"
162msgid "SUN4U-8000-9R.severity"
163msgstr "Major"
164msgid "SUN4U-8000-9R.description"
165msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
166msgid "SUN4U-8000-9R.response"
167msgstr "The fault manager will attempt to remove the affected CPU from service."
168msgid "SUN4U-8000-9R.impact"
169msgstr "System performance may be affected."
170msgid "SUN4U-8000-9R.action"
171msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
172#
173# code: SUN4U-8000-AC
174# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
175#
176msgid "SUN4U-8000-AC.type"
177msgstr "Fault"
178msgid "SUN4U-8000-AC.severity"
179msgstr "Major"
180msgid "SUN4U-8000-AC.description"
181msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
182msgid "SUN4U-8000-AC.response"
183msgstr "The fault manager will attempt to remove the affected CPU from service."
184msgid "SUN4U-8000-AC.impact"
185msgstr "System performance may be affected."
186msgid "SUN4U-8000-AC.action"
187msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
188#
189# code: SUN4U-8000-CQ
190# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
191#
192msgid "SUN4U-8000-CQ.type"
193msgstr "Fault"
194msgid "SUN4U-8000-CQ.severity"
195msgstr "Major"
196msgid "SUN4U-8000-CQ.description"
197msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
198msgid "SUN4U-8000-CQ.response"
199msgstr "The fault manager will attempt to remove the affected CPU from service."
200msgid "SUN4U-8000-CQ.impact"
201msgstr "System performance may be affected."
202msgid "SUN4U-8000-CQ.action"
203msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
204#
205# code: SUN4U-8000-DE
206# keys: fault.cpu.ultraSPARC-IIIplus.dcache
207#
208msgid "SUN4U-8000-DE.type"
209msgstr "Fault"
210msgid "SUN4U-8000-DE.severity"
211msgstr "Major"
212msgid "SUN4U-8000-DE.description"
213msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
214msgid "SUN4U-8000-DE.response"
215msgstr "The fault manager will attempt to remove the affected CPU from service."
216msgid "SUN4U-8000-DE.impact"
217msgstr "System performance may be affected."
218msgid "SUN4U-8000-DE.action"
219msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
220#
221# code: SUN4U-8000-EJ
222# keys: fault.cpu.ultraSPARC-IIIplus.icache
223#
224msgid "SUN4U-8000-EJ.type"
225msgstr "Fault"
226msgid "SUN4U-8000-EJ.severity"
227msgstr "Major"
228msgid "SUN4U-8000-EJ.description"
229msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
230msgid "SUN4U-8000-EJ.response"
231msgstr "The fault manager will attempt to remove the affected CPU from service."
232msgid "SUN4U-8000-EJ.impact"
233msgstr "System performance may be affected."
234msgid "SUN4U-8000-EJ.action"
235msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
236#
237# code: SUN4U-8000-F2
238# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
239#
240msgid "SUN4U-8000-F2.type"
241msgstr "Fault"
242msgid "SUN4U-8000-F2.severity"
243msgstr "Major"
244msgid "SUN4U-8000-F2.description"
245msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
246msgid "SUN4U-8000-F2.response"
247msgstr "The fault manager will attempt to remove the affected CPU from service."
248msgid "SUN4U-8000-F2.impact"
249msgstr "System performance may be affected."
250msgid "SUN4U-8000-F2.action"
251msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
252#
253# code: SUN4U-8000-GX
254# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
255#
256msgid "SUN4U-8000-GX.type"
257msgstr "Fault"
258msgid "SUN4U-8000-GX.severity"
259msgstr "Major"
260msgid "SUN4U-8000-GX.description"
261msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
262msgid "SUN4U-8000-GX.response"
263msgstr "An attempt will be made to remove the affected CPU from service."
264msgid "SUN4U-8000-GX.impact"
265msgstr "System performance may be affected."
266msgid "SUN4U-8000-GX.action"
267msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU."
268#
269# code: SUN4U-8000-H5
270# keys: fault.cpu.ultraSPARC-IV.dcache
271#
272msgid "SUN4U-8000-H5.type"
273msgstr "Fault"
274msgid "SUN4U-8000-H5.severity"
275msgstr "Major"
276msgid "SUN4U-8000-H5.description"
277msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
278msgid "SUN4U-8000-H5.response"
279msgstr "The fault manager will attempt to remove the affected CPU from service."
280msgid "SUN4U-8000-H5.impact"
281msgstr "System performance may be affected."
282msgid "SUN4U-8000-H5.action"
283msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
284#
285# code: SUN4U-8000-JS
286# keys: fault.cpu.ultraSPARC-IV.icache
287#
288msgid "SUN4U-8000-JS.type"
289msgstr "Fault"
290msgid "SUN4U-8000-JS.severity"
291msgstr "Major"
292msgid "SUN4U-8000-JS.description"
293msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
294msgid "SUN4U-8000-JS.response"
295msgstr "The fault manager will attempt to remove the affected CPU from service."
296msgid "SUN4U-8000-JS.impact"
297msgstr "System performance may be affected."
298msgid "SUN4U-8000-JS.action"
299msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
300#
301# code: SUN4U-8000-KA
302# keys: fault.cpu.ultraSPARC-IV.l2cachedata
303#
304msgid "SUN4U-8000-KA.type"
305msgstr "Fault"
306msgid "SUN4U-8000-KA.severity"
307msgstr "Major"
308msgid "SUN4U-8000-KA.description"
309msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
310msgid "SUN4U-8000-KA.response"
311msgstr "The fault manager will attempt to remove the affected CPU from service."
312msgid "SUN4U-8000-KA.impact"
313msgstr "System performance may be affected."
314msgid "SUN4U-8000-KA.action"
315msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
316#
317# code: SUN4U-8000-LP
318# keys: fault.cpu.ultraSPARC-IV.l2cachetag
319#
320msgid "SUN4U-8000-LP.type"
321msgstr "Fault"
322msgid "SUN4U-8000-LP.severity"
323msgstr "Major"
324msgid "SUN4U-8000-LP.description"
325msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
326msgid "SUN4U-8000-LP.response"
327msgstr "The fault manager will attempt to remove the affected CPU from service."
328msgid "SUN4U-8000-LP.impact"
329msgstr "System performance may be affected."
330msgid "SUN4U-8000-LP.action"
331msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
332#
333# code: SUN4U-8000-MD
334# keys: fault.cpu.ultraSPARC-III.fpu
335#
336msgid "SUN4U-8000-MD.type"
337msgstr "Fault"
338msgid "SUN4U-8000-MD.severity"
339msgstr "Major"
340msgid "SUN4U-8000-MD.description"
341msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
342msgid "SUN4U-8000-MD.response"
343msgstr "The fault manager will attempt to remove the affected CPU from service."
344msgid "SUN4U-8000-MD.impact"
345msgstr "System performance may be affected."
346msgid "SUN4U-8000-MD.action"
347msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
348#
349# code: SUN4U-8000-NH
350# keys: fault.cpu.ultraSPARC-IIIi.fpu
351#
352msgid "SUN4U-8000-NH.type"
353msgstr "Fault"
354msgid "SUN4U-8000-NH.severity"
355msgstr "Major"
356msgid "SUN4U-8000-NH.description"
357msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
358msgid "SUN4U-8000-NH.response"
359msgstr "The fault manager will attempt to remove the affected CPU from service."
360msgid "SUN4U-8000-NH.impact"
361msgstr "System performance may be affected."
362msgid "SUN4U-8000-NH.action"
363msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
364#
365# code: SUN4U-8000-P3
366# keys: fault.cpu.ultraSPARC-IIIplus.fpu
367#
368msgid "SUN4U-8000-P3.type"
369msgstr "Fault"
370msgid "SUN4U-8000-P3.severity"
371msgstr "Major"
372msgid "SUN4U-8000-P3.description"
373msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
374msgid "SUN4U-8000-P3.response"
375msgstr "The fault manager will attempt to remove the affected CPU from service."
376msgid "SUN4U-8000-P3.impact"
377msgstr "System performance may be affected."
378msgid "SUN4U-8000-P3.action"
379msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
380#
381# code: SUN4U-8000-QY
382# keys: fault.cpu.ultraSPARC-IV.fpu
383#
384msgid "SUN4U-8000-QY.type"
385msgstr "Fault"
386msgid "SUN4U-8000-QY.severity"
387msgstr "Major"
388msgid "SUN4U-8000-QY.description"
389msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
390msgid "SUN4U-8000-QY.response"
391msgstr "The fault manager will attempt to remove the affected CPU from service."
392msgid "SUN4U-8000-QY.impact"
393msgstr "System performance may be affected."
394msgid "SUN4U-8000-QY.action"
395msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
396#
397# code: SUN4U-8000-RQ
398# keys: fault.cpu.ultraSPARC-IVplus.fpu
399#
400msgid "SUN4U-8000-RQ.type"
401msgstr "Fault"
402msgid "SUN4U-8000-RQ.severity"
403msgstr "Major"
404msgid "SUN4U-8000-RQ.description"
405msgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
406msgid "SUN4U-8000-RQ.response"
407msgstr "The fault manager will attempt to remove the affected CPU from service."
408msgid "SUN4U-8000-RQ.impact"
409msgstr "System performance may be affected."
410msgid "SUN4U-8000-RQ.action"
411msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
412#
413# code: SUN4U-8000-SC
414# keys: fault.cpu.ultraSPARC-IVplus.dcache
415#
416msgid "SUN4U-8000-SC.type"
417msgstr "Fault"
418msgid "SUN4U-8000-SC.severity"
419msgstr "Major"
420msgid "SUN4U-8000-SC.description"
421msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
422msgid "SUN4U-8000-SC.response"
423msgstr "The fault manager will attempt to remove the affected CPU from service."
424msgid "SUN4U-8000-SC.impact"
425msgstr "System performance may be affected."
426msgid "SUN4U-8000-SC.action"
427msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
428#
429# code: SUN4U-8000-TR
430# keys: fault.cpu.ultraSPARC-IVplus.icache
431#
432msgid "SUN4U-8000-TR.type"
433msgstr "Fault"
434msgid "SUN4U-8000-TR.severity"
435msgstr "Major"
436msgid "SUN4U-8000-TR.description"
437msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
438msgid "SUN4U-8000-TR.response"
439msgstr "The fault manager will attempt to remove the affected CPU from service."
440msgid "SUN4U-8000-TR.impact"
441msgstr "System performance may be affected."
442msgid "SUN4U-8000-TR.action"
443msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
444#
445# code: SUN4U-8000-U4
446# keys: fault.cpu.ultraSPARC-IVplus.pcache
447#
448msgid "SUN4U-8000-U4.type"
449msgstr "Fault"
450msgid "SUN4U-8000-U4.severity"
451msgstr "Major"
452msgid "SUN4U-8000-U4.description"
453msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
454msgid "SUN4U-8000-U4.response"
455msgstr "The fault manager will attempt to remove the affected CPU from service."
456msgid "SUN4U-8000-U4.impact"
457msgstr "System performance may be affected."
458msgid "SUN4U-8000-U4.action"
459msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
460#
461# code: SUN4U-8000-VX
462# keys: fault.cpu.ultraSPARC-IVplus.dtlb
463#
464msgid "SUN4U-8000-VX.type"
465msgstr "Fault"
466msgid "SUN4U-8000-VX.severity"
467msgstr "Major"
468msgid "SUN4U-8000-VX.description"
469msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
470msgid "SUN4U-8000-VX.response"
471msgstr "The fault manager will attempt to remove the affected CPU from service."
472msgid "SUN4U-8000-VX.impact"
473msgstr "System performance may be affected."
474msgid "SUN4U-8000-VX.action"
475msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
476#
477# code: SUN4U-8000-W2
478# keys: fault.cpu.ultraSPARC-IVplus.itlb
479#
480msgid "SUN4U-8000-W2.type"
481msgstr "Fault"
482msgid "SUN4U-8000-W2.severity"
483msgstr "Major"
484msgid "SUN4U-8000-W2.description"
485msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
486msgid "SUN4U-8000-W2.response"
487msgstr "The fault manager will attempt to remove the affected CPU from service."
488msgid "SUN4U-8000-W2.impact"
489msgstr "System performance may be affected."
490msgid "SUN4U-8000-W2.action"
491msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
492#
493# code: SUN4U-8000-XJ
494# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
495#
496msgid "SUN4U-8000-XJ.type"
497msgstr "Fault"
498msgid "SUN4U-8000-XJ.severity"
499msgstr "Major"
500msgid "SUN4U-8000-XJ.description"
501msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
502msgid "SUN4U-8000-XJ.response"
503msgstr "The fault manager will attempt to remove the affected CPU from service."
504msgid "SUN4U-8000-XJ.impact"
505msgstr "System performance may be affected."
506msgid "SUN4U-8000-XJ.action"
507msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
508#
509# code: SUN4U-8000-YE
510# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
511#
512msgid "SUN4U-8000-YE.type"
513msgstr "Fault"
514msgid "SUN4U-8000-YE.severity"
515msgstr "Major"
516msgid "SUN4U-8000-YE.description"
517msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
518msgid "SUN4U-8000-YE.response"
519msgstr "The fault manager will attempt to remove the affected CPU from service."
520msgid "SUN4U-8000-YE.impact"
521msgstr "System performance may be affected."
522msgid "SUN4U-8000-YE.action"
523msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
524#
525# code: SUN4U-8001-0J
526# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
527#
528msgid "SUN4U-8001-0J.type"
529msgstr "Fault"
530msgid "SUN4U-8001-0J.severity"
531msgstr "Major"
532msgid "SUN4U-8001-0J.description"
533msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
534msgid "SUN4U-8001-0J.response"
535msgstr "The fault manager will attempt to remove the affected CPU from service."
536msgid "SUN4U-8001-0J.impact"
537msgstr "System performance may be affected."
538msgid "SUN4U-8001-0J.action"
539msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
540#
541# code: SUN4U-8001-1E
542# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
543#
544msgid "SUN4U-8001-1E.type"
545msgstr "Fault"
546msgid "SUN4U-8001-1E.severity"
547msgstr "Major"
548msgid "SUN4U-8001-1E.description"
549msgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
550msgid "SUN4U-8001-1E.response"
551msgstr "The fault manager will attempt to remove the affected CPU from service."
552msgid "SUN4U-8001-1E.impact"
553msgstr "System performance may be affected."
554msgid "SUN4U-8001-1E.action"
555msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
556#
557# code: SUN4U-8001-2X
558# keys: defect.ultraSPARC-II.memory.nodiag
559#
560msgid "SUN4U-8001-2X.type"
561msgstr "Defect"
562msgid "SUN4U-8001-2X.severity"
563msgstr "Minor"
564msgid "SUN4U-8001-2X.description"
565msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable.  Refer to %s for more information."
566msgid "SUN4U-8001-2X.response"
567msgstr "The error information has been saved for examination by Sun."
568msgid "SUN4U-8001-2X.impact"
569msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
570msgid "SUN4U-8001-2X.action"
571msgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
572#
573# code: SUN4U-8001-32
574# keys: fault.memory.datapath
575#
576msgid "SUN4U-8001-32.type"
577msgstr "Fault"
578msgid "SUN4U-8001-32.severity"
579msgstr "Major"
580msgid "SUN4U-8001-32.description"
581msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.  Refer to %s for more information."
582msgid "SUN4U-8001-32.response"
583msgstr "Error reports from the affected components will be logged for examination by Sun."
584msgid "SUN4U-8001-32.impact"
585msgstr "System performance and stability may be affected."
586msgid "SUN4U-8001-32.action"
587msgstr "Contact your service provider for further diagnosis."
588#
589# code: SUN4U-8001-4R
590# keys: fault.io.datapath
591#
592msgid "SUN4U-8001-4R.type"
593msgstr "Fault"
594msgid "SUN4U-8001-4R.severity"
595msgstr "Critical"
596msgid "SUN4U-8001-4R.description"
597msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
598msgid "SUN4U-8001-4R.response"
599msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
600msgid "SUN4U-8001-4R.impact"
601msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
602msgid "SUN4U-8001-4R.action"
603msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
604#
605# code: SUN4U-8001-54
606# keys: defect.io.pci.driver fault.io.datapath
607#
608msgid "SUN4U-8001-54.type"
609msgstr "Fault"
610msgid "SUN4U-8001-54.severity"
611msgstr "Critical"
612msgid "SUN4U-8001-54.description"
613msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
614msgid "SUN4U-8001-54.response"
615msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
616msgid "SUN4U-8001-54.impact"
617msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
618msgid "SUN4U-8001-54.action"
619msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
620#
621# code: SUN4U-8001-6Q
622# keys: fault.io.datapath fault.io.pci.bus
623#
624msgid "SUN4U-8001-6Q.type"
625msgstr "Fault"
626msgid "SUN4U-8001-6Q.severity"
627msgstr "Critical"
628msgid "SUN4U-8001-6Q.description"
629msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
630msgid "SUN4U-8001-6Q.response"
631msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
632msgid "SUN4U-8001-6Q.impact"
633msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
634msgid "SUN4U-8001-6Q.action"
635msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
636#
637# code: SUN4U-8001-7C
638# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
639#
640msgid "SUN4U-8001-7C.type"
641msgstr "Fault"
642msgid "SUN4U-8001-7C.severity"
643msgstr "Critical"
644msgid "SUN4U-8001-7C.description"
645msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
646msgid "SUN4U-8001-7C.response"
647msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
648msgid "SUN4U-8001-7C.impact"
649msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
650msgid "SUN4U-8001-7C.action"
651msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
652#
653# code: SUN4U-8001-83
654# keys: fault.io.datapath fault.io.pci.device
655#
656msgid "SUN4U-8001-83.type"
657msgstr "Fault"
658msgid "SUN4U-8001-83.severity"
659msgstr "Critical"
660msgid "SUN4U-8001-83.description"
661msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
662msgid "SUN4U-8001-83.response"
663msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
664msgid "SUN4U-8001-83.impact"
665msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
666msgid "SUN4U-8001-83.action"
667msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
668#
669# code: SUN4U-8001-9Y
670# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
671#
672msgid "SUN4U-8001-9Y.type"
673msgstr "Fault"
674msgid "SUN4U-8001-9Y.severity"
675msgstr "Critical"
676msgid "SUN4U-8001-9Y.description"
677msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
678msgid "SUN4U-8001-9Y.response"
679msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
680msgid "SUN4U-8001-9Y.impact"
681msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
682msgid "SUN4U-8001-9Y.action"
683msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
684#
685# code: SUN4U-8001-AD
686# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
687#
688msgid "SUN4U-8001-AD.type"
689msgstr "Fault"
690msgid "SUN4U-8001-AD.severity"
691msgstr "Critical"
692msgid "SUN4U-8001-AD.description"
693msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
694msgid "SUN4U-8001-AD.response"
695msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
696msgid "SUN4U-8001-AD.impact"
697msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
698msgid "SUN4U-8001-AD.action"
699msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
700#
701# code: SUN4U-8001-CH
702# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
703#
704msgid "SUN4U-8001-CH.type"
705msgstr "Fault"
706msgid "SUN4U-8001-CH.severity"
707msgstr "Critical"
708msgid "SUN4U-8001-CH.description"
709msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
710msgid "SUN4U-8001-CH.response"
711msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
712msgid "SUN4U-8001-CH.impact"
713msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
714msgid "SUN4U-8001-CH.action"
715msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
716#
717# code: SUN4U-8001-DA
718# keys: fault.io.hbus
719#
720msgid "SUN4U-8001-DA.type"
721msgstr "Fault"
722msgid "SUN4U-8001-DA.severity"
723msgstr "Critical"
724msgid "SUN4U-8001-DA.description"
725msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
726msgid "SUN4U-8001-DA.response"
727msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
728msgid "SUN4U-8001-DA.impact"
729msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
730msgid "SUN4U-8001-DA.action"
731msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
732#
733# code: SUN4U-8001-EP
734# keys: defect.io.pci.driver fault.io.hbus
735#
736msgid "SUN4U-8001-EP.type"
737msgstr "Fault"
738msgid "SUN4U-8001-EP.severity"
739msgstr "Critical"
740msgid "SUN4U-8001-EP.description"
741msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
742msgid "SUN4U-8001-EP.response"
743msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
744msgid "SUN4U-8001-EP.impact"
745msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
746msgid "SUN4U-8001-EP.action"
747msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
748#
749# code: SUN4U-8001-F5
750# keys: fault.io.hbus fault.io.pci.bus
751#
752msgid "SUN4U-8001-F5.type"
753msgstr "Fault"
754msgid "SUN4U-8001-F5.severity"
755msgstr "Critical"
756msgid "SUN4U-8001-F5.description"
757msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
758msgid "SUN4U-8001-F5.response"
759msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
760msgid "SUN4U-8001-F5.impact"
761msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
762msgid "SUN4U-8001-F5.action"
763msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
764#
765# code: SUN4U-8001-GS
766# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
767#
768msgid "SUN4U-8001-GS.type"
769msgstr "Fault"
770msgid "SUN4U-8001-GS.severity"
771msgstr "Critical"
772msgid "SUN4U-8001-GS.description"
773msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
774msgid "SUN4U-8001-GS.response"
775msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
776msgid "SUN4U-8001-GS.impact"
777msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
778msgid "SUN4U-8001-GS.action"
779msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
780#
781# code: SUN4U-8001-H2
782# keys: fault.io.hbus fault.io.pci.device
783#
784msgid "SUN4U-8001-H2.type"
785msgstr "Fault"
786msgid "SUN4U-8001-H2.severity"
787msgstr "Critical"
788msgid "SUN4U-8001-H2.description"
789msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
790msgid "SUN4U-8001-H2.response"
791msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
792msgid "SUN4U-8001-H2.impact"
793msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
794msgid "SUN4U-8001-H2.action"
795msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
796#
797# code: SUN4U-8001-JX
798# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
799#
800msgid "SUN4U-8001-JX.type"
801msgstr "Fault"
802msgid "SUN4U-8001-JX.severity"
803msgstr "Critical"
804msgid "SUN4U-8001-JX.description"
805msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
806msgid "SUN4U-8001-JX.response"
807msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
808msgid "SUN4U-8001-JX.impact"
809msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
810msgid "SUN4U-8001-JX.action"
811msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
812#
813# code: SUN4U-8001-KE
814# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
815#
816msgid "SUN4U-8001-KE.type"
817msgstr "Fault"
818msgid "SUN4U-8001-KE.severity"
819msgstr "Critical"
820msgid "SUN4U-8001-KE.description"
821msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
822msgid "SUN4U-8001-KE.response"
823msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
824msgid "SUN4U-8001-KE.impact"
825msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
826msgid "SUN4U-8001-KE.action"
827msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
828#
829# code: SUN4U-8001-LJ
830# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
831#
832msgid "SUN4U-8001-LJ.type"
833msgstr "Fault"
834msgid "SUN4U-8001-LJ.severity"
835msgstr "Critical"
836msgid "SUN4U-8001-LJ.description"
837msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
838msgid "SUN4U-8001-LJ.response"
839msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
840msgid "SUN4U-8001-LJ.impact"
841msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
842msgid "SUN4U-8001-LJ.action"
843msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
844#
845# code: SUN4U-8001-MC
846# keys: fault.io.datapath fault.io.hbus
847#
848msgid "SUN4U-8001-MC.type"
849msgstr "Fault"
850msgid "SUN4U-8001-MC.severity"
851msgstr "Critical"
852msgid "SUN4U-8001-MC.description"
853msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
854msgid "SUN4U-8001-MC.response"
855msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
856msgid "SUN4U-8001-MC.impact"
857msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
858msgid "SUN4U-8001-MC.action"
859msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
860#
861# code: SUN4U-8001-NQ
862# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
863#
864msgid "SUN4U-8001-NQ.type"
865msgstr "Fault"
866msgid "SUN4U-8001-NQ.severity"
867msgstr "Critical"
868msgid "SUN4U-8001-NQ.description"
869msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
870msgid "SUN4U-8001-NQ.response"
871msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
872msgid "SUN4U-8001-NQ.impact"
873msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
874msgid "SUN4U-8001-NQ.action"
875msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
876#
877# code: SUN4U-8001-P4
878# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
879#
880msgid "SUN4U-8001-P4.type"
881msgstr "Fault"
882msgid "SUN4U-8001-P4.severity"
883msgstr "Critical"
884msgid "SUN4U-8001-P4.description"
885msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
886msgid "SUN4U-8001-P4.response"
887msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
888msgid "SUN4U-8001-P4.impact"
889msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
890msgid "SUN4U-8001-P4.action"
891msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
892#
893# code: SUN4U-8001-QR
894# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
895#
896msgid "SUN4U-8001-QR.type"
897msgstr "Fault"
898msgid "SUN4U-8001-QR.severity"
899msgstr "Critical"
900msgid "SUN4U-8001-QR.description"
901msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
902msgid "SUN4U-8001-QR.response"
903msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
904msgid "SUN4U-8001-QR.impact"
905msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
906msgid "SUN4U-8001-QR.action"
907msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
908#
909# code: SUN4U-8001-RH
910# keys: fault.io.datapath fault.io.hbus fault.io.pci.device
911#
912msgid "SUN4U-8001-RH.type"
913msgstr "Fault"
914msgid "SUN4U-8001-RH.severity"
915msgstr "Critical"
916msgid "SUN4U-8001-RH.description"
917msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
918msgid "SUN4U-8001-RH.response"
919msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
920msgid "SUN4U-8001-RH.impact"
921msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
922msgid "SUN4U-8001-RH.action"
923msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
924#
925# code: SUN4U-8001-SD
926# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
927#
928msgid "SUN4U-8001-SD.type"
929msgstr "Fault"
930msgid "SUN4U-8001-SD.severity"
931msgstr "Critical"
932msgid "SUN4U-8001-SD.description"
933msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
934msgid "SUN4U-8001-SD.response"
935msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
936msgid "SUN4U-8001-SD.impact"
937msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
938msgid "SUN4U-8001-SD.action"
939msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
940#
941# code: SUN4U-8001-TY
942# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
943#
944msgid "SUN4U-8001-TY.type"
945msgstr "Fault"
946msgid "SUN4U-8001-TY.severity"
947msgstr "Critical"
948msgid "SUN4U-8001-TY.description"
949msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
950msgid "SUN4U-8001-TY.response"
951msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
952msgid "SUN4U-8001-TY.impact"
953msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
954msgid "SUN4U-8001-TY.action"
955msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
956#
957# code: SUN4U-8001-U3
958# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
959#
960msgid "SUN4U-8001-U3.type"
961msgstr "Fault"
962msgid "SUN4U-8001-U3.severity"
963msgstr "Critical"
964msgid "SUN4U-8001-U3.description"
965msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
966msgid "SUN4U-8001-U3.response"
967msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
968msgid "SUN4U-8001-U3.impact"
969msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
970msgid "SUN4U-8001-U3.action"
971msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
972#
973# code: SUN4U-8001-VS
974# keys: fault.io.schizo
975#
976msgid "SUN4U-8001-VS.type"
977msgstr "Fault"
978msgid "SUN4U-8001-VS.severity"
979msgstr "Critical"
980msgid "SUN4U-8001-VS.description"
981msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
982msgid "SUN4U-8001-VS.response"
983msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
984msgid "SUN4U-8001-VS.impact"
985msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
986msgid "SUN4U-8001-VS.action"
987msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
988#
989# code: SUN4U-8001-W5
990# keys: defect.io.pci.driver fault.io.schizo
991#
992msgid "SUN4U-8001-W5.type"
993msgstr "Fault"
994msgid "SUN4U-8001-W5.severity"
995msgstr "Critical"
996msgid "SUN4U-8001-W5.description"
997msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
998msgid "SUN4U-8001-W5.response"
999msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1000msgid "SUN4U-8001-W5.impact"
1001msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1002msgid "SUN4U-8001-W5.action"
1003msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1004#
1005# code: SUN4U-8001-XP
1006# keys: fault.io.pci.bus fault.io.schizo
1007#
1008msgid "SUN4U-8001-XP.type"
1009msgstr "Fault"
1010msgid "SUN4U-8001-XP.severity"
1011msgstr "Critical"
1012msgid "SUN4U-8001-XP.description"
1013msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1014msgid "SUN4U-8001-XP.response"
1015msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1016msgid "SUN4U-8001-XP.impact"
1017msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1018msgid "SUN4U-8001-XP.action"
1019msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1020#
1021# code: SUN4U-8001-YA
1022# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
1023#
1024msgid "SUN4U-8001-YA.type"
1025msgstr "Fault"
1026msgid "SUN4U-8001-YA.severity"
1027msgstr "Critical"
1028msgid "SUN4U-8001-YA.description"
1029msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1030msgid "SUN4U-8001-YA.response"
1031msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1032msgid "SUN4U-8001-YA.impact"
1033msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1034msgid "SUN4U-8001-YA.action"
1035msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1036#
1037# code: SUN4U-8002-0R
1038# keys: fault.io.pci.device fault.io.schizo
1039#
1040msgid "SUN4U-8002-0R.type"
1041msgstr "Fault"
1042msgid "SUN4U-8002-0R.severity"
1043msgstr "Critical"
1044msgid "SUN4U-8002-0R.description"
1045msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1046msgid "SUN4U-8002-0R.response"
1047msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1048msgid "SUN4U-8002-0R.impact"
1049msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1050msgid "SUN4U-8002-0R.action"
1051msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1052#
1053# code: SUN4U-8002-14
1054# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
1055#
1056msgid "SUN4U-8002-14.type"
1057msgstr "Fault"
1058msgid "SUN4U-8002-14.severity"
1059msgstr "Critical"
1060msgid "SUN4U-8002-14.description"
1061msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1062msgid "SUN4U-8002-14.response"
1063msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1064msgid "SUN4U-8002-14.impact"
1065msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1066msgid "SUN4U-8002-14.action"
1067msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1068#
1069# code: SUN4U-8002-2Q
1070# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
1071#
1072msgid "SUN4U-8002-2Q.type"
1073msgstr "Fault"
1074msgid "SUN4U-8002-2Q.severity"
1075msgstr "Critical"
1076msgid "SUN4U-8002-2Q.description"
1077msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1078msgid "SUN4U-8002-2Q.response"
1079msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1080msgid "SUN4U-8002-2Q.impact"
1081msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1082msgid "SUN4U-8002-2Q.action"
1083msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1084#
1085# code: SUN4U-8002-3C
1086# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
1087#
1088msgid "SUN4U-8002-3C.type"
1089msgstr "Fault"
1090msgid "SUN4U-8002-3C.severity"
1091msgstr "Critical"
1092msgid "SUN4U-8002-3C.description"
1093msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1094msgid "SUN4U-8002-3C.response"
1095msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1096msgid "SUN4U-8002-3C.impact"
1097msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1098msgid "SUN4U-8002-3C.action"
1099msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1100#
1101# code: SUN4U-8002-4J
1102# keys: fault.io.datapath fault.io.schizo
1103#
1104msgid "SUN4U-8002-4J.type"
1105msgstr "Fault"
1106msgid "SUN4U-8002-4J.severity"
1107msgstr "Critical"
1108msgid "SUN4U-8002-4J.description"
1109msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1110msgid "SUN4U-8002-4J.response"
1111msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1112msgid "SUN4U-8002-4J.impact"
1113msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1114msgid "SUN4U-8002-4J.action"
1115msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1116#
1117# code: SUN4U-8002-5E
1118# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
1119#
1120msgid "SUN4U-8002-5E.type"
1121msgstr "Fault"
1122msgid "SUN4U-8002-5E.severity"
1123msgstr "Critical"
1124msgid "SUN4U-8002-5E.description"
1125msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1126msgid "SUN4U-8002-5E.response"
1127msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1128msgid "SUN4U-8002-5E.impact"
1129msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1130msgid "SUN4U-8002-5E.action"
1131msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1132#
1133# code: SUN4U-8002-6X
1134# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
1135#
1136msgid "SUN4U-8002-6X.type"
1137msgstr "Fault"
1138msgid "SUN4U-8002-6X.severity"
1139msgstr "Critical"
1140msgid "SUN4U-8002-6X.description"
1141msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1142msgid "SUN4U-8002-6X.response"
1143msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1144msgid "SUN4U-8002-6X.impact"
1145msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1146msgid "SUN4U-8002-6X.action"
1147msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1148#
1149# code: SUN4U-8002-72
1150# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
1151#
1152msgid "SUN4U-8002-72.type"
1153msgstr "Fault"
1154msgid "SUN4U-8002-72.severity"
1155msgstr "Critical"
1156msgid "SUN4U-8002-72.description"
1157msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1158msgid "SUN4U-8002-72.response"
1159msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1160msgid "SUN4U-8002-72.impact"
1161msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1162msgid "SUN4U-8002-72.action"
1163msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1164#
1165# code: SUN4U-8002-8A
1166# keys: fault.io.datapath fault.io.pci.device fault.io.schizo
1167#
1168msgid "SUN4U-8002-8A.type"
1169msgstr "Fault"
1170msgid "SUN4U-8002-8A.severity"
1171msgstr "Critical"
1172msgid "SUN4U-8002-8A.description"
1173msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1174msgid "SUN4U-8002-8A.response"
1175msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1176msgid "SUN4U-8002-8A.impact"
1177msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1178msgid "SUN4U-8002-8A.action"
1179msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1180#
1181# code: SUN4U-8002-9P
1182# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
1183#
1184msgid "SUN4U-8002-9P.type"
1185msgstr "Fault"
1186msgid "SUN4U-8002-9P.severity"
1187msgstr "Critical"
1188msgid "SUN4U-8002-9P.description"
1189msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1190msgid "SUN4U-8002-9P.response"
1191msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1192msgid "SUN4U-8002-9P.impact"
1193msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1194msgid "SUN4U-8002-9P.action"
1195msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1196#
1197# code: SUN4U-8002-A5
1198# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1199#
1200msgid "SUN4U-8002-A5.type"
1201msgstr "Fault"
1202msgid "SUN4U-8002-A5.severity"
1203msgstr "Critical"
1204msgid "SUN4U-8002-A5.description"
1205msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1206msgid "SUN4U-8002-A5.response"
1207msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1208msgid "SUN4U-8002-A5.impact"
1209msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1210msgid "SUN4U-8002-A5.action"
1211msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1212#
1213# code: SUN4U-8002-CS
1214# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1215#
1216msgid "SUN4U-8002-CS.type"
1217msgstr "Fault"
1218msgid "SUN4U-8002-CS.severity"
1219msgstr "Critical"
1220msgid "SUN4U-8002-CS.description"
1221msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1222msgid "SUN4U-8002-CS.response"
1223msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1224msgid "SUN4U-8002-CS.impact"
1225msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1226msgid "SUN4U-8002-CS.action"
1227msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1228#
1229# code: SUN4U-8002-D3
1230# keys: fault.io.hbus fault.io.schizo
1231#
1232msgid "SUN4U-8002-D3.type"
1233msgstr "Fault"
1234msgid "SUN4U-8002-D3.severity"
1235msgstr "Critical"
1236msgid "SUN4U-8002-D3.description"
1237msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1238msgid "SUN4U-8002-D3.response"
1239msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1240msgid "SUN4U-8002-D3.impact"
1241msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1242msgid "SUN4U-8002-D3.action"
1243msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1244#
1245# code: SUN4U-8002-EY
1246# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
1247#
1248msgid "SUN4U-8002-EY.type"
1249msgstr "Fault"
1250msgid "SUN4U-8002-EY.severity"
1251msgstr "Critical"
1252msgid "SUN4U-8002-EY.description"
1253msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1254msgid "SUN4U-8002-EY.response"
1255msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1256msgid "SUN4U-8002-EY.impact"
1257msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1258msgid "SUN4U-8002-EY.action"
1259msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1260#
1261# code: SUN4U-8002-FD
1262# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
1263#
1264msgid "SUN4U-8002-FD.type"
1265msgstr "Fault"
1266msgid "SUN4U-8002-FD.severity"
1267msgstr "Critical"
1268msgid "SUN4U-8002-FD.description"
1269msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1270msgid "SUN4U-8002-FD.response"
1271msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1272msgid "SUN4U-8002-FD.impact"
1273msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1274msgid "SUN4U-8002-FD.action"
1275msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1276#
1277# code: SUN4U-8002-GH
1278# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
1279#
1280msgid "SUN4U-8002-GH.type"
1281msgstr "Fault"
1282msgid "SUN4U-8002-GH.severity"
1283msgstr "Critical"
1284msgid "SUN4U-8002-GH.description"
1285msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1286msgid "SUN4U-8002-GH.response"
1287msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1288msgid "SUN4U-8002-GH.impact"
1289msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1290msgid "SUN4U-8002-GH.action"
1291msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1292#
1293# code: SUN4U-8002-HC
1294# keys: fault.io.hbus fault.io.pci.device fault.io.schizo
1295#
1296msgid "SUN4U-8002-HC.type"
1297msgstr "Fault"
1298msgid "SUN4U-8002-HC.severity"
1299msgstr "Critical"
1300msgid "SUN4U-8002-HC.description"
1301msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1302msgid "SUN4U-8002-HC.response"
1303msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1304msgid "SUN4U-8002-HC.impact"
1305msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1306msgid "SUN4U-8002-HC.action"
1307msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1308#
1309# code: SUN4U-8002-JQ
1310# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
1311#
1312msgid "SUN4U-8002-JQ.type"
1313msgstr "Fault"
1314msgid "SUN4U-8002-JQ.severity"
1315msgstr "Critical"
1316msgid "SUN4U-8002-JQ.description"
1317msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1318msgid "SUN4U-8002-JQ.response"
1319msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1320msgid "SUN4U-8002-JQ.impact"
1321msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1322msgid "SUN4U-8002-JQ.action"
1323msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1324#
1325# code: SUN4U-8002-K4
1326# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1327#
1328msgid "SUN4U-8002-K4.type"
1329msgstr "Fault"
1330msgid "SUN4U-8002-K4.severity"
1331msgstr "Critical"
1332msgid "SUN4U-8002-K4.description"
1333msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1334msgid "SUN4U-8002-K4.response"
1335msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1336msgid "SUN4U-8002-K4.impact"
1337msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1338msgid "SUN4U-8002-K4.action"
1339msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1340#
1341# code: SUN4U-8002-LR
1342# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1343#
1344msgid "SUN4U-8002-LR.type"
1345msgstr "Fault"
1346msgid "SUN4U-8002-LR.severity"
1347msgstr "Critical"
1348msgid "SUN4U-8002-LR.description"
1349msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1350msgid "SUN4U-8002-LR.response"
1351msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1352msgid "SUN4U-8002-LR.impact"
1353msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1354msgid "SUN4U-8002-LR.action"
1355msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1356#
1357# code: SUN4U-8002-M2
1358# keys: fault.io.datapath fault.io.hbus fault.io.schizo
1359#
1360msgid "SUN4U-8002-M2.type"
1361msgstr "Fault"
1362msgid "SUN4U-8002-M2.severity"
1363msgstr "Critical"
1364msgid "SUN4U-8002-M2.description"
1365msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1366msgid "SUN4U-8002-M2.response"
1367msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1368msgid "SUN4U-8002-M2.impact"
1369msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1370msgid "SUN4U-8002-M2.action"
1371msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1372#
1373# code: SUN4U-8002-NX
1374# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
1375#
1376msgid "SUN4U-8002-NX.type"
1377msgstr "Fault"
1378msgid "SUN4U-8002-NX.severity"
1379msgstr "Critical"
1380msgid "SUN4U-8002-NX.description"
1381msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1382msgid "SUN4U-8002-NX.response"
1383msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1384msgid "SUN4U-8002-NX.impact"
1385msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1386msgid "SUN4U-8002-NX.action"
1387msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1388#
1389# code: SUN4U-8002-PE
1390# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1391#
1392msgid "SUN4U-8002-PE.type"
1393msgstr "Fault"
1394msgid "SUN4U-8002-PE.severity"
1395msgstr "Critical"
1396msgid "SUN4U-8002-PE.description"
1397msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1398msgid "SUN4U-8002-PE.response"
1399msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1400msgid "SUN4U-8002-PE.impact"
1401msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1402msgid "SUN4U-8002-PE.action"
1403msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1404#
1405# code: SUN4U-8002-QJ
1406# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1407#
1408msgid "SUN4U-8002-QJ.type"
1409msgstr "Fault"
1410msgid "SUN4U-8002-QJ.severity"
1411msgstr "Critical"
1412msgid "SUN4U-8002-QJ.description"
1413msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1414msgid "SUN4U-8002-QJ.response"
1415msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1416msgid "SUN4U-8002-QJ.impact"
1417msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1418msgid "SUN4U-8002-QJ.action"
1419msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1420#
1421# code: SUN4U-8002-RS
1422# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1423#
1424msgid "SUN4U-8002-RS.type"
1425msgstr "Fault"
1426msgid "SUN4U-8002-RS.severity"
1427msgstr "Critical"
1428msgid "SUN4U-8002-RS.description"
1429msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1430msgid "SUN4U-8002-RS.response"
1431msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1432msgid "SUN4U-8002-RS.impact"
1433msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1434msgid "SUN4U-8002-RS.action"
1435msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1436#
1437# code: SUN4U-8002-S5
1438# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1439#
1440msgid "SUN4U-8002-S5.type"
1441msgstr "Fault"
1442msgid "SUN4U-8002-S5.severity"
1443msgstr "Critical"
1444msgid "SUN4U-8002-S5.description"
1445msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1446msgid "SUN4U-8002-S5.response"
1447msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1448msgid "SUN4U-8002-S5.impact"
1449msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1450msgid "SUN4U-8002-S5.action"
1451msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1452#
1453# code: SUN4U-8002-TP
1454# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1455#
1456msgid "SUN4U-8002-TP.type"
1457msgstr "Fault"
1458msgid "SUN4U-8002-TP.severity"
1459msgstr "Critical"
1460msgid "SUN4U-8002-TP.description"
1461msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1462msgid "SUN4U-8002-TP.response"
1463msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1464msgid "SUN4U-8002-TP.impact"
1465msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1466msgid "SUN4U-8002-TP.action"
1467msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1468#
1469# code: SUN4U-8002-UA
1470# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1471#
1472msgid "SUN4U-8002-UA.type"
1473msgstr "Fault"
1474msgid "SUN4U-8002-UA.severity"
1475msgstr "Critical"
1476msgid "SUN4U-8002-UA.description"
1477msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1478msgid "SUN4U-8002-UA.response"
1479msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1480msgid "SUN4U-8002-UA.impact"
1481msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1482msgid "SUN4U-8002-UA.action"
1483msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1484#
1485# code: SUN4U-8002-VH
1486# keys: fault.io.xmits
1487#
1488msgid "SUN4U-8002-VH.type"
1489msgstr "Fault"
1490msgid "SUN4U-8002-VH.severity"
1491msgstr "Critical"
1492msgid "SUN4U-8002-VH.description"
1493msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1494msgid "SUN4U-8002-VH.response"
1495msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1496msgid "SUN4U-8002-VH.impact"
1497msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1498msgid "SUN4U-8002-VH.action"
1499msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1500#
1501# code: SUN4U-8002-WD
1502# keys: defect.io.pci.driver fault.io.xmits
1503#
1504msgid "SUN4U-8002-WD.type"
1505msgstr "Fault"
1506msgid "SUN4U-8002-WD.severity"
1507msgstr "Critical"
1508msgid "SUN4U-8002-WD.description"
1509msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1510msgid "SUN4U-8002-WD.response"
1511msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1512msgid "SUN4U-8002-WD.impact"
1513msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1514msgid "SUN4U-8002-WD.action"
1515msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1516#
1517# code: SUN4U-8002-XY
1518# keys: fault.io.pci.bus fault.io.xmits
1519#
1520msgid "SUN4U-8002-XY.type"
1521msgstr "Fault"
1522msgid "SUN4U-8002-XY.severity"
1523msgstr "Critical"
1524msgid "SUN4U-8002-XY.description"
1525msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1526msgid "SUN4U-8002-XY.response"
1527msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1528msgid "SUN4U-8002-XY.impact"
1529msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1530msgid "SUN4U-8002-XY.action"
1531msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1532#
1533# code: SUN4U-8002-Y3
1534# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
1535#
1536msgid "SUN4U-8002-Y3.type"
1537msgstr "Fault"
1538msgid "SUN4U-8002-Y3.severity"
1539msgstr "Critical"
1540msgid "SUN4U-8002-Y3.description"
1541msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1542msgid "SUN4U-8002-Y3.response"
1543msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1544msgid "SUN4U-8002-Y3.impact"
1545msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1546msgid "SUN4U-8002-Y3.action"
1547msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1548#
1549# code: SUN4U-8003-0Y
1550# keys: fault.io.pci.device fault.io.xmits
1551#
1552msgid "SUN4U-8003-0Y.type"
1553msgstr "Fault"
1554msgid "SUN4U-8003-0Y.severity"
1555msgstr "Critical"
1556msgid "SUN4U-8003-0Y.description"
1557msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1558msgid "SUN4U-8003-0Y.response"
1559msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1560msgid "SUN4U-8003-0Y.impact"
1561msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1562msgid "SUN4U-8003-0Y.action"
1563msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1564#
1565# code: SUN4U-8003-13
1566# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
1567#
1568msgid "SUN4U-8003-13.type"
1569msgstr "Fault"
1570msgid "SUN4U-8003-13.severity"
1571msgstr "Critical"
1572msgid "SUN4U-8003-13.description"
1573msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1574msgid "SUN4U-8003-13.response"
1575msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1576msgid "SUN4U-8003-13.impact"
1577msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1578msgid "SUN4U-8003-13.action"
1579msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1580#
1581# code: SUN4U-8003-2H
1582# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
1583#
1584msgid "SUN4U-8003-2H.type"
1585msgstr "Fault"
1586msgid "SUN4U-8003-2H.severity"
1587msgstr "Critical"
1588msgid "SUN4U-8003-2H.description"
1589msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1590msgid "SUN4U-8003-2H.response"
1591msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1592msgid "SUN4U-8003-2H.impact"
1593msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1594msgid "SUN4U-8003-2H.action"
1595msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1596#
1597# code: SUN4U-8003-3D
1598# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
1599#
1600msgid "SUN4U-8003-3D.type"
1601msgstr "Fault"
1602msgid "SUN4U-8003-3D.severity"
1603msgstr "Critical"
1604msgid "SUN4U-8003-3D.description"
1605msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1606msgid "SUN4U-8003-3D.response"
1607msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1608msgid "SUN4U-8003-3D.impact"
1609msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1610msgid "SUN4U-8003-3D.action"
1611msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1612#
1613# code: SUN4U-8003-4P
1614# keys: fault.io.datapath fault.io.xmits
1615#
1616msgid "SUN4U-8003-4P.type"
1617msgstr "Fault"
1618msgid "SUN4U-8003-4P.severity"
1619msgstr "Critical"
1620msgid "SUN4U-8003-4P.description"
1621msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1622msgid "SUN4U-8003-4P.response"
1623msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1624msgid "SUN4U-8003-4P.impact"
1625msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1626msgid "SUN4U-8003-4P.action"
1627msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1628#
1629# code: SUN4U-8003-5A
1630# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
1631#
1632msgid "SUN4U-8003-5A.type"
1633msgstr "Fault"
1634msgid "SUN4U-8003-5A.severity"
1635msgstr "Critical"
1636msgid "SUN4U-8003-5A.description"
1637msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1638msgid "SUN4U-8003-5A.response"
1639msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1640msgid "SUN4U-8003-5A.impact"
1641msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1642msgid "SUN4U-8003-5A.action"
1643msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1644#
1645# code: SUN4U-8003-6S
1646# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
1647#
1648msgid "SUN4U-8003-6S.type"
1649msgstr "Fault"
1650msgid "SUN4U-8003-6S.severity"
1651msgstr "Critical"
1652msgid "SUN4U-8003-6S.description"
1653msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1654msgid "SUN4U-8003-6S.response"
1655msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1656msgid "SUN4U-8003-6S.impact"
1657msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1658msgid "SUN4U-8003-6S.action"
1659msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1660#
1661# code: SUN4U-8003-75
1662# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
1663#
1664msgid "SUN4U-8003-75.type"
1665msgstr "Fault"
1666msgid "SUN4U-8003-75.severity"
1667msgstr "Critical"
1668msgid "SUN4U-8003-75.description"
1669msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1670msgid "SUN4U-8003-75.response"
1671msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1672msgid "SUN4U-8003-75.impact"
1673msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1674msgid "SUN4U-8003-75.action"
1675msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1676#
1677# code: SUN4U-8003-8E
1678# keys: fault.io.datapath fault.io.pci.device fault.io.xmits
1679#
1680msgid "SUN4U-8003-8E.type"
1681msgstr "Fault"
1682msgid "SUN4U-8003-8E.severity"
1683msgstr "Critical"
1684msgid "SUN4U-8003-8E.description"
1685msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1686msgid "SUN4U-8003-8E.response"
1687msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1688msgid "SUN4U-8003-8E.impact"
1689msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1690msgid "SUN4U-8003-8E.action"
1691msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1692#
1693# code: SUN4U-8003-9J
1694# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
1695#
1696msgid "SUN4U-8003-9J.type"
1697msgstr "Fault"
1698msgid "SUN4U-8003-9J.severity"
1699msgstr "Critical"
1700msgid "SUN4U-8003-9J.description"
1701msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1702msgid "SUN4U-8003-9J.response"
1703msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1704msgid "SUN4U-8003-9J.impact"
1705msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1706msgid "SUN4U-8003-9J.action"
1707msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1708#
1709# code: SUN4U-8003-A2
1710# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1711#
1712msgid "SUN4U-8003-A2.type"
1713msgstr "Fault"
1714msgid "SUN4U-8003-A2.severity"
1715msgstr "Critical"
1716msgid "SUN4U-8003-A2.description"
1717msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1718msgid "SUN4U-8003-A2.response"
1719msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1720msgid "SUN4U-8003-A2.impact"
1721msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1722msgid "SUN4U-8003-A2.action"
1723msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1724#
1725# code: SUN4U-8003-CX
1726# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1727#
1728msgid "SUN4U-8003-CX.type"
1729msgstr "Fault"
1730msgid "SUN4U-8003-CX.severity"
1731msgstr "Critical"
1732msgid "SUN4U-8003-CX.description"
1733msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1734msgid "SUN4U-8003-CX.response"
1735msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1736msgid "SUN4U-8003-CX.impact"
1737msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1738msgid "SUN4U-8003-CX.action"
1739msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1740#
1741# code: SUN4U-8003-D4
1742# keys: fault.io.hbus fault.io.xmits
1743#
1744msgid "SUN4U-8003-D4.type"
1745msgstr "Fault"
1746msgid "SUN4U-8003-D4.severity"
1747msgstr "Critical"
1748msgid "SUN4U-8003-D4.description"
1749msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1750msgid "SUN4U-8003-D4.response"
1751msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1752msgid "SUN4U-8003-D4.impact"
1753msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1754msgid "SUN4U-8003-D4.action"
1755msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1756#
1757# code: SUN4U-8003-ER
1758# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
1759#
1760msgid "SUN4U-8003-ER.type"
1761msgstr "Fault"
1762msgid "SUN4U-8003-ER.severity"
1763msgstr "Critical"
1764msgid "SUN4U-8003-ER.description"
1765msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1766msgid "SUN4U-8003-ER.response"
1767msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1768msgid "SUN4U-8003-ER.impact"
1769msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1770msgid "SUN4U-8003-ER.action"
1771msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1772#
1773# code: SUN4U-8003-FC
1774# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
1775#
1776msgid "SUN4U-8003-FC.type"
1777msgstr "Fault"
1778msgid "SUN4U-8003-FC.severity"
1779msgstr "Critical"
1780msgid "SUN4U-8003-FC.description"
1781msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1782msgid "SUN4U-8003-FC.response"
1783msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1784msgid "SUN4U-8003-FC.impact"
1785msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1786msgid "SUN4U-8003-FC.action"
1787msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1788#
1789# code: SUN4U-8003-GQ
1790# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
1791#
1792msgid "SUN4U-8003-GQ.type"
1793msgstr "Fault"
1794msgid "SUN4U-8003-GQ.severity"
1795msgstr "Critical"
1796msgid "SUN4U-8003-GQ.description"
1797msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1798msgid "SUN4U-8003-GQ.response"
1799msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1800msgid "SUN4U-8003-GQ.impact"
1801msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1802msgid "SUN4U-8003-GQ.action"
1803msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1804#
1805# code: SUN4U-8003-HD
1806# keys: fault.io.hbus fault.io.pci.device fault.io.xmits
1807#
1808msgid "SUN4U-8003-HD.type"
1809msgstr "Fault"
1810msgid "SUN4U-8003-HD.severity"
1811msgstr "Critical"
1812msgid "SUN4U-8003-HD.description"
1813msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1814msgid "SUN4U-8003-HD.response"
1815msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1816msgid "SUN4U-8003-HD.impact"
1817msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1818msgid "SUN4U-8003-HD.action"
1819msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1820#
1821# code: SUN4U-8003-JH
1822# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
1823#
1824msgid "SUN4U-8003-JH.type"
1825msgstr "Fault"
1826msgid "SUN4U-8003-JH.severity"
1827msgstr "Critical"
1828msgid "SUN4U-8003-JH.description"
1829msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1830msgid "SUN4U-8003-JH.response"
1831msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1832msgid "SUN4U-8003-JH.impact"
1833msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1834msgid "SUN4U-8003-JH.action"
1835msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1836#
1837# code: SUN4U-8003-K3
1838# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1839#
1840msgid "SUN4U-8003-K3.type"
1841msgstr "Fault"
1842msgid "SUN4U-8003-K3.severity"
1843msgstr "Critical"
1844msgid "SUN4U-8003-K3.description"
1845msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1846msgid "SUN4U-8003-K3.response"
1847msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1848msgid "SUN4U-8003-K3.impact"
1849msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1850msgid "SUN4U-8003-K3.action"
1851msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1852#
1853# code: SUN4U-8003-LY
1854# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1855#
1856msgid "SUN4U-8003-LY.type"
1857msgstr "Fault"
1858msgid "SUN4U-8003-LY.severity"
1859msgstr "Critical"
1860msgid "SUN4U-8003-LY.description"
1861msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1862msgid "SUN4U-8003-LY.response"
1863msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1864msgid "SUN4U-8003-LY.impact"
1865msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1866msgid "SUN4U-8003-LY.action"
1867msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1868#
1869# code: SUN4U-8003-M5
1870# keys: fault.io.datapath fault.io.hbus fault.io.xmits
1871#
1872msgid "SUN4U-8003-M5.type"
1873msgstr "Fault"
1874msgid "SUN4U-8003-M5.severity"
1875msgstr "Critical"
1876msgid "SUN4U-8003-M5.description"
1877msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1878msgid "SUN4U-8003-M5.response"
1879msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1880msgid "SUN4U-8003-M5.impact"
1881msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1882msgid "SUN4U-8003-M5.action"
1883msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1884#
1885# code: SUN4U-8003-NS
1886# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
1887#
1888msgid "SUN4U-8003-NS.type"
1889msgstr "Fault"
1890msgid "SUN4U-8003-NS.severity"
1891msgstr "Critical"
1892msgid "SUN4U-8003-NS.description"
1893msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1894msgid "SUN4U-8003-NS.response"
1895msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1896msgid "SUN4U-8003-NS.impact"
1897msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1898msgid "SUN4U-8003-NS.action"
1899msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1900#
1901# code: SUN4U-8003-PA
1902# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1903#
1904msgid "SUN4U-8003-PA.type"
1905msgstr "Fault"
1906msgid "SUN4U-8003-PA.severity"
1907msgstr "Critical"
1908msgid "SUN4U-8003-PA.description"
1909msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1910msgid "SUN4U-8003-PA.response"
1911msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1912msgid "SUN4U-8003-PA.impact"
1913msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1914msgid "SUN4U-8003-PA.action"
1915msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1916#
1917# code: SUN4U-8003-QP
1918# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1919#
1920msgid "SUN4U-8003-QP.type"
1921msgstr "Fault"
1922msgid "SUN4U-8003-QP.severity"
1923msgstr "Critical"
1924msgid "SUN4U-8003-QP.description"
1925msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1926msgid "SUN4U-8003-QP.response"
1927msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1928msgid "SUN4U-8003-QP.impact"
1929msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1930msgid "SUN4U-8003-QP.action"
1931msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1932#
1933# code: SUN4U-8003-RX
1934# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1935#
1936msgid "SUN4U-8003-RX.type"
1937msgstr "Fault"
1938msgid "SUN4U-8003-RX.severity"
1939msgstr "Critical"
1940msgid "SUN4U-8003-RX.description"
1941msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1942msgid "SUN4U-8003-RX.response"
1943msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1944msgid "SUN4U-8003-RX.impact"
1945msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1946msgid "SUN4U-8003-RX.action"
1947msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1948#
1949# code: SUN4U-8003-S2
1950# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1951#
1952msgid "SUN4U-8003-S2.type"
1953msgstr "Fault"
1954msgid "SUN4U-8003-S2.severity"
1955msgstr "Critical"
1956msgid "SUN4U-8003-S2.description"
1957msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1958msgid "SUN4U-8003-S2.response"
1959msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1960msgid "SUN4U-8003-S2.impact"
1961msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1962msgid "SUN4U-8003-S2.action"
1963msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1964#
1965# code: SUN4U-8003-TJ
1966# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1967#
1968msgid "SUN4U-8003-TJ.type"
1969msgstr "Fault"
1970msgid "SUN4U-8003-TJ.severity"
1971msgstr "Critical"
1972msgid "SUN4U-8003-TJ.description"
1973msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
1974msgid "SUN4U-8003-TJ.response"
1975msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1976msgid "SUN4U-8003-TJ.impact"
1977msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1978msgid "SUN4U-8003-TJ.action"
1979msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
1980#
1981# code: SUN4U-8003-UE
1982# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1983#
1984msgid "SUN4U-8003-UE.type"
1985msgstr "Fault"
1986msgid "SUN4U-8003-UE.severity"
1987msgstr "Critical"
1988msgid "SUN4U-8003-UE.description"
1989msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
1990msgid "SUN4U-8003-UE.response"
1991msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1992msgid "SUN4U-8003-UE.impact"
1993msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1994msgid "SUN4U-8003-UE.action"
1995msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
1996#
1997# code: SUN4U-8003-VQ
1998# keys: fault.io.schizo fault.io.xmits
1999#
2000msgid "SUN4U-8003-VQ.type"
2001msgstr "Fault"
2002msgid "SUN4U-8003-VQ.severity"
2003msgstr "Critical"
2004msgid "SUN4U-8003-VQ.description"
2005msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2006msgid "SUN4U-8003-VQ.response"
2007msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2008msgid "SUN4U-8003-VQ.impact"
2009msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2010msgid "SUN4U-8003-VQ.action"
2011msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2012#
2013# code: SUN4U-8003-WC
2014# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
2015#
2016msgid "SUN4U-8003-WC.type"
2017msgstr "Fault"
2018msgid "SUN4U-8003-WC.severity"
2019msgstr "Critical"
2020msgid "SUN4U-8003-WC.description"
2021msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2022msgid "SUN4U-8003-WC.response"
2023msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2024msgid "SUN4U-8003-WC.impact"
2025msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2026msgid "SUN4U-8003-WC.action"
2027msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2028#
2029# code: SUN4U-8003-XR
2030# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
2031#
2032msgid "SUN4U-8003-XR.type"
2033msgstr "Fault"
2034msgid "SUN4U-8003-XR.severity"
2035msgstr "Critical"
2036msgid "SUN4U-8003-XR.description"
2037msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2038msgid "SUN4U-8003-XR.response"
2039msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2040msgid "SUN4U-8003-XR.impact"
2041msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2042msgid "SUN4U-8003-XR.action"
2043msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2044#
2045# code: SUN4U-8003-Y4
2046# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
2047#
2048msgid "SUN4U-8003-Y4.type"
2049msgstr "Fault"
2050msgid "SUN4U-8003-Y4.severity"
2051msgstr "Critical"
2052msgid "SUN4U-8003-Y4.description"
2053msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2054msgid "SUN4U-8003-Y4.response"
2055msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2056msgid "SUN4U-8003-Y4.impact"
2057msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2058msgid "SUN4U-8003-Y4.action"
2059msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2060#
2061# code: SUN4U-8004-0A
2062# keys: fault.io.pci.device fault.io.schizo fault.io.xmits
2063#
2064msgid "SUN4U-8004-0A.type"
2065msgstr "Fault"
2066msgid "SUN4U-8004-0A.severity"
2067msgstr "Critical"
2068msgid "SUN4U-8004-0A.description"
2069msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2070msgid "SUN4U-8004-0A.response"
2071msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2072msgid "SUN4U-8004-0A.impact"
2073msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2074msgid "SUN4U-8004-0A.action"
2075msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2076#
2077# code: SUN4U-8004-1P
2078# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
2079#
2080msgid "SUN4U-8004-1P.type"
2081msgstr "Fault"
2082msgid "SUN4U-8004-1P.severity"
2083msgstr "Critical"
2084msgid "SUN4U-8004-1P.description"
2085msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2086msgid "SUN4U-8004-1P.response"
2087msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2088msgid "SUN4U-8004-1P.impact"
2089msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2090msgid "SUN4U-8004-1P.action"
2091msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2092#
2093# code: SUN4U-8004-25
2094# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2095#
2096msgid "SUN4U-8004-25.type"
2097msgstr "Fault"
2098msgid "SUN4U-8004-25.severity"
2099msgstr "Critical"
2100msgid "SUN4U-8004-25.description"
2101msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2102msgid "SUN4U-8004-25.response"
2103msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2104msgid "SUN4U-8004-25.impact"
2105msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2106msgid "SUN4U-8004-25.action"
2107msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2108#
2109# code: SUN4U-8004-3S
2110# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2111#
2112msgid "SUN4U-8004-3S.type"
2113msgstr "Fault"
2114msgid "SUN4U-8004-3S.severity"
2115msgstr "Critical"
2116msgid "SUN4U-8004-3S.description"
2117msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2118msgid "SUN4U-8004-3S.response"
2119msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2120msgid "SUN4U-8004-3S.impact"
2121msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2122msgid "SUN4U-8004-3S.action"
2123msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2124#
2125# code: SUN4U-8004-43
2126# keys: fault.io.datapath fault.io.schizo fault.io.xmits
2127#
2128msgid "SUN4U-8004-43.type"
2129msgstr "Fault"
2130msgid "SUN4U-8004-43.severity"
2131msgstr "Critical"
2132msgid "SUN4U-8004-43.description"
2133msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2134msgid "SUN4U-8004-43.response"
2135msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2136msgid "SUN4U-8004-43.impact"
2137msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2138msgid "SUN4U-8004-43.action"
2139msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2140#
2141# code: SUN4U-8004-5Y
2142# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
2143#
2144msgid "SUN4U-8004-5Y.type"
2145msgstr "Fault"
2146msgid "SUN4U-8004-5Y.severity"
2147msgstr "Critical"
2148msgid "SUN4U-8004-5Y.description"
2149msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2150msgid "SUN4U-8004-5Y.response"
2151msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2152msgid "SUN4U-8004-5Y.impact"
2153msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2154msgid "SUN4U-8004-5Y.action"
2155msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2156#
2157# code: SUN4U-8004-6D
2158# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2159#
2160msgid "SUN4U-8004-6D.type"
2161msgstr "Fault"
2162msgid "SUN4U-8004-6D.severity"
2163msgstr "Critical"
2164msgid "SUN4U-8004-6D.description"
2165msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2166msgid "SUN4U-8004-6D.response"
2167msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2168msgid "SUN4U-8004-6D.impact"
2169msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2170msgid "SUN4U-8004-6D.action"
2171msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2172#
2173# code: SUN4U-8004-7H
2174# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2175#
2176msgid "SUN4U-8004-7H.type"
2177msgstr "Fault"
2178msgid "SUN4U-8004-7H.severity"
2179msgstr "Critical"
2180msgid "SUN4U-8004-7H.description"
2181msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2182msgid "SUN4U-8004-7H.response"
2183msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2184msgid "SUN4U-8004-7H.impact"
2185msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2186msgid "SUN4U-8004-7H.action"
2187msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2188#
2189# code: SUN4U-8004-8R
2190# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2191#
2192msgid "SUN4U-8004-8R.type"
2193msgstr "Fault"
2194msgid "SUN4U-8004-8R.severity"
2195msgstr "Critical"
2196msgid "SUN4U-8004-8R.description"
2197msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2198msgid "SUN4U-8004-8R.response"
2199msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2200msgid "SUN4U-8004-8R.impact"
2201msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2202msgid "SUN4U-8004-8R.action"
2203msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2204#
2205# code: SUN4U-8004-94
2206# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2207#
2208msgid "SUN4U-8004-94.type"
2209msgstr "Fault"
2210msgid "SUN4U-8004-94.severity"
2211msgstr "Critical"
2212msgid "SUN4U-8004-94.description"
2213msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2214msgid "SUN4U-8004-94.response"
2215msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2216msgid "SUN4U-8004-94.impact"
2217msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2218msgid "SUN4U-8004-94.action"
2219msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2220#
2221# code: SUN4U-8004-AQ
2222# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2223#
2224msgid "SUN4U-8004-AQ.type"
2225msgstr "Fault"
2226msgid "SUN4U-8004-AQ.severity"
2227msgstr "Critical"
2228msgid "SUN4U-8004-AQ.description"
2229msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2230msgid "SUN4U-8004-AQ.response"
2231msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2232msgid "SUN4U-8004-AQ.impact"
2233msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2234msgid "SUN4U-8004-AQ.action"
2235msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2236#
2237# code: SUN4U-8004-CC
2238# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2239#
2240msgid "SUN4U-8004-CC.type"
2241msgstr "Fault"
2242msgid "SUN4U-8004-CC.severity"
2243msgstr "Critical"
2244msgid "SUN4U-8004-CC.description"
2245msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2246msgid "SUN4U-8004-CC.response"
2247msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2248msgid "SUN4U-8004-CC.impact"
2249msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2250msgid "SUN4U-8004-CC.action"
2251msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2252#
2253# code: SUN4U-8004-DJ
2254# keys: fault.io.hbus fault.io.schizo fault.io.xmits
2255#
2256msgid "SUN4U-8004-DJ.type"
2257msgstr "Fault"
2258msgid "SUN4U-8004-DJ.severity"
2259msgstr "Critical"
2260msgid "SUN4U-8004-DJ.description"
2261msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2262msgid "SUN4U-8004-DJ.response"
2263msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2264msgid "SUN4U-8004-DJ.impact"
2265msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2266msgid "SUN4U-8004-DJ.action"
2267msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2268#
2269# code: SUN4U-8004-EE
2270# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
2271#
2272msgid "SUN4U-8004-EE.type"
2273msgstr "Fault"
2274msgid "SUN4U-8004-EE.severity"
2275msgstr "Critical"
2276msgid "SUN4U-8004-EE.description"
2277msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2278msgid "SUN4U-8004-EE.response"
2279msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2280msgid "SUN4U-8004-EE.impact"
2281msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2282msgid "SUN4U-8004-EE.action"
2283msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2284#
2285# code: SUN4U-8004-FX
2286# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2287#
2288msgid "SUN4U-8004-FX.type"
2289msgstr "Fault"
2290msgid "SUN4U-8004-FX.severity"
2291msgstr "Critical"
2292msgid "SUN4U-8004-FX.description"
2293msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2294msgid "SUN4U-8004-FX.response"
2295msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2296msgid "SUN4U-8004-FX.impact"
2297msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2298msgid "SUN4U-8004-FX.action"
2299msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2300#
2301# code: SUN4U-8004-G2
2302# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2303#
2304msgid "SUN4U-8004-G2.type"
2305msgstr "Fault"
2306msgid "SUN4U-8004-G2.severity"
2307msgstr "Critical"
2308msgid "SUN4U-8004-G2.description"
2309msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2310msgid "SUN4U-8004-G2.response"
2311msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2312msgid "SUN4U-8004-G2.impact"
2313msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2314msgid "SUN4U-8004-G2.action"
2315msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2316#
2317# code: SUN4U-8004-HS
2318# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2319#
2320msgid "SUN4U-8004-HS.type"
2321msgstr "Fault"
2322msgid "SUN4U-8004-HS.severity"
2323msgstr "Critical"
2324msgid "SUN4U-8004-HS.description"
2325msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2326msgid "SUN4U-8004-HS.response"
2327msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2328msgid "SUN4U-8004-HS.impact"
2329msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2330msgid "SUN4U-8004-HS.action"
2331msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2332#
2333# code: SUN4U-8004-J5
2334# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2335#
2336msgid "SUN4U-8004-J5.type"
2337msgstr "Fault"
2338msgid "SUN4U-8004-J5.severity"
2339msgstr "Critical"
2340msgid "SUN4U-8004-J5.description"
2341msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2342msgid "SUN4U-8004-J5.response"
2343msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2344msgid "SUN4U-8004-J5.impact"
2345msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2346msgid "SUN4U-8004-J5.action"
2347msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2348#
2349# code: SUN4U-8004-KP
2350# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2351#
2352msgid "SUN4U-8004-KP.type"
2353msgstr "Fault"
2354msgid "SUN4U-8004-KP.severity"
2355msgstr "Critical"
2356msgid "SUN4U-8004-KP.description"
2357msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2358msgid "SUN4U-8004-KP.response"
2359msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2360msgid "SUN4U-8004-KP.impact"
2361msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2362msgid "SUN4U-8004-KP.action"
2363msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2364#
2365# code: SUN4U-8004-LA
2366# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2367#
2368msgid "SUN4U-8004-LA.type"
2369msgstr "Fault"
2370msgid "SUN4U-8004-LA.severity"
2371msgstr "Critical"
2372msgid "SUN4U-8004-LA.description"
2373msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2374msgid "SUN4U-8004-LA.response"
2375msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2376msgid "SUN4U-8004-LA.impact"
2377msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2378msgid "SUN4U-8004-LA.action"
2379msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2380#
2381# code: SUN4U-8004-MH
2382# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2383#
2384msgid "SUN4U-8004-MH.type"
2385msgstr "Fault"
2386msgid "SUN4U-8004-MH.severity"
2387msgstr "Critical"
2388msgid "SUN4U-8004-MH.description"
2389msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2390msgid "SUN4U-8004-MH.response"
2391msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2392msgid "SUN4U-8004-MH.impact"
2393msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2394msgid "SUN4U-8004-MH.action"
2395msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2396#
2397# code: SUN4U-8004-ND
2398# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2399#
2400msgid "SUN4U-8004-ND.type"
2401msgstr "Fault"
2402msgid "SUN4U-8004-ND.severity"
2403msgstr "Critical"
2404msgid "SUN4U-8004-ND.description"
2405msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2406msgid "SUN4U-8004-ND.response"
2407msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2408msgid "SUN4U-8004-ND.impact"
2409msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2410msgid "SUN4U-8004-ND.action"
2411msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2412#
2413# code: SUN4U-8004-PY
2414# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2415#
2416msgid "SUN4U-8004-PY.type"
2417msgstr "Fault"
2418msgid "SUN4U-8004-PY.severity"
2419msgstr "Critical"
2420msgid "SUN4U-8004-PY.description"
2421msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2422msgid "SUN4U-8004-PY.response"
2423msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2424msgid "SUN4U-8004-PY.impact"
2425msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2426msgid "SUN4U-8004-PY.action"
2427msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2428#
2429# code: SUN4U-8004-Q3
2430# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2431#
2432msgid "SUN4U-8004-Q3.type"
2433msgstr "Fault"
2434msgid "SUN4U-8004-Q3.severity"
2435msgstr "Critical"
2436msgid "SUN4U-8004-Q3.description"
2437msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2438msgid "SUN4U-8004-Q3.response"
2439msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2440msgid "SUN4U-8004-Q3.impact"
2441msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2442msgid "SUN4U-8004-Q3.action"
2443msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2444#
2445# code: SUN4U-8004-RC
2446# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2447#
2448msgid "SUN4U-8004-RC.type"
2449msgstr "Fault"
2450msgid "SUN4U-8004-RC.severity"
2451msgstr "Critical"
2452msgid "SUN4U-8004-RC.description"
2453msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2454msgid "SUN4U-8004-RC.response"
2455msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2456msgid "SUN4U-8004-RC.impact"
2457msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2458msgid "SUN4U-8004-RC.action"
2459msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2460#
2461# code: SUN4U-8004-SQ
2462# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2463#
2464msgid "SUN4U-8004-SQ.type"
2465msgstr "Fault"
2466msgid "SUN4U-8004-SQ.severity"
2467msgstr "Critical"
2468msgid "SUN4U-8004-SQ.description"
2469msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2470msgid "SUN4U-8004-SQ.response"
2471msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2472msgid "SUN4U-8004-SQ.impact"
2473msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2474msgid "SUN4U-8004-SQ.action"
2475msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2476#
2477# code: SUN4U-8004-T4
2478# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2479#
2480msgid "SUN4U-8004-T4.type"
2481msgstr "Fault"
2482msgid "SUN4U-8004-T4.severity"
2483msgstr "Critical"
2484msgid "SUN4U-8004-T4.description"
2485msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2486msgid "SUN4U-8004-T4.response"
2487msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2488msgid "SUN4U-8004-T4.impact"
2489msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2490msgid "SUN4U-8004-T4.action"
2491msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2492#
2493# code: SUN4U-8004-UR
2494# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2495#
2496msgid "SUN4U-8004-UR.type"
2497msgstr "Fault"
2498msgid "SUN4U-8004-UR.severity"
2499msgstr "Critical"
2500msgid "SUN4U-8004-UR.description"
2501msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2502msgid "SUN4U-8004-UR.response"
2503msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2504msgid "SUN4U-8004-UR.impact"
2505msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2506msgid "SUN4U-8004-UR.action"
2507msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2508#
2509# code: SUN4U-8004-V2
2510# keys: fault.io.psycho
2511#
2512msgid "SUN4U-8004-V2.type"
2513msgstr "Fault"
2514msgid "SUN4U-8004-V2.severity"
2515msgstr "Critical"
2516msgid "SUN4U-8004-V2.description"
2517msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2518msgid "SUN4U-8004-V2.response"
2519msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2520msgid "SUN4U-8004-V2.impact"
2521msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2522msgid "SUN4U-8004-V2.action"
2523msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2524#
2525# code: SUN4U-8004-WX
2526# keys: defect.io.pci.driver fault.io.psycho
2527#
2528msgid "SUN4U-8004-WX.type"
2529msgstr "Fault"
2530msgid "SUN4U-8004-WX.severity"
2531msgstr "Critical"
2532msgid "SUN4U-8004-WX.description"
2533msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2534msgid "SUN4U-8004-WX.response"
2535msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2536msgid "SUN4U-8004-WX.impact"
2537msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2538msgid "SUN4U-8004-WX.action"
2539msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2540#
2541# code: SUN4U-8004-XE
2542# keys: fault.io.datapath fault.io.psycho
2543#
2544msgid "SUN4U-8004-XE.type"
2545msgstr "Fault"
2546msgid "SUN4U-8004-XE.severity"
2547msgstr "Critical"
2548msgid "SUN4U-8004-XE.description"
2549msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2550msgid "SUN4U-8004-XE.response"
2551msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2552msgid "SUN4U-8004-XE.impact"
2553msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2554msgid "SUN4U-8004-XE.action"
2555msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2556#
2557# code: SUN4U-8004-YJ
2558# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
2559#
2560msgid "SUN4U-8004-YJ.type"
2561msgstr "Fault"
2562msgid "SUN4U-8004-YJ.severity"
2563msgstr "Critical"
2564msgid "SUN4U-8004-YJ.description"
2565msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2566msgid "SUN4U-8004-YJ.response"
2567msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2568msgid "SUN4U-8004-YJ.impact"
2569msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2570msgid "SUN4U-8004-YJ.action"
2571msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2572#
2573# code: SUN4U-8005-0E
2574# keys: fault.io.hbus fault.io.psycho
2575#
2576msgid "SUN4U-8005-0E.type"
2577msgstr "Fault"
2578msgid "SUN4U-8005-0E.severity"
2579msgstr "Critical"
2580msgid "SUN4U-8005-0E.description"
2581msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2582msgid "SUN4U-8005-0E.response"
2583msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2584msgid "SUN4U-8005-0E.impact"
2585msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2586msgid "SUN4U-8005-0E.action"
2587msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2588#
2589# code: SUN4U-8005-1J
2590# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
2591#
2592msgid "SUN4U-8005-1J.type"
2593msgstr "Fault"
2594msgid "SUN4U-8005-1J.severity"
2595msgstr "Critical"
2596msgid "SUN4U-8005-1J.description"
2597msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2598msgid "SUN4U-8005-1J.response"
2599msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2600msgid "SUN4U-8005-1J.impact"
2601msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2602msgid "SUN4U-8005-1J.action"
2603msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2604#
2605# code: SUN4U-8005-22
2606# keys: fault.io.datapath fault.io.hbus fault.io.psycho
2607#
2608msgid "SUN4U-8005-22.type"
2609msgstr "Fault"
2610msgid "SUN4U-8005-22.severity"
2611msgstr "Critical"
2612msgid "SUN4U-8005-22.description"
2613msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2614msgid "SUN4U-8005-22.response"
2615msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2616msgid "SUN4U-8005-22.impact"
2617msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2618msgid "SUN4U-8005-22.action"
2619msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2620#
2621# code: SUN4U-8005-3X
2622# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
2623#
2624msgid "SUN4U-8005-3X.type"
2625msgstr "Fault"
2626msgid "SUN4U-8005-3X.severity"
2627msgstr "Critical"
2628msgid "SUN4U-8005-3X.description"
2629msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2630msgid "SUN4U-8005-3X.response"
2631msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2632msgid "SUN4U-8005-3X.impact"
2633msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2634msgid "SUN4U-8005-3X.action"
2635msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2636#
2637# code: SUN4U-8005-44
2638# keys: fault.io.pci.bus fault.io.psycho
2639#
2640msgid "SUN4U-8005-44.type"
2641msgstr "Fault"
2642msgid "SUN4U-8005-44.severity"
2643msgstr "Critical"
2644msgid "SUN4U-8005-44.description"
2645msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2646msgid "SUN4U-8005-44.response"
2647msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2648msgid "SUN4U-8005-44.impact"
2649msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2650msgid "SUN4U-8005-44.action"
2651msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2652#
2653# code: SUN4U-8005-5R
2654# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
2655#
2656msgid "SUN4U-8005-5R.type"
2657msgstr "Fault"
2658msgid "SUN4U-8005-5R.severity"
2659msgstr "Critical"
2660msgid "SUN4U-8005-5R.description"
2661msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2662msgid "SUN4U-8005-5R.response"
2663msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2664msgid "SUN4U-8005-5R.impact"
2665msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2666msgid "SUN4U-8005-5R.action"
2667msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2668#
2669# code: SUN4U-8005-6C
2670# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
2671#
2672msgid "SUN4U-8005-6C.type"
2673msgstr "Fault"
2674msgid "SUN4U-8005-6C.severity"
2675msgstr "Critical"
2676msgid "SUN4U-8005-6C.description"
2677msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2678msgid "SUN4U-8005-6C.response"
2679msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2680msgid "SUN4U-8005-6C.impact"
2681msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2682msgid "SUN4U-8005-6C.action"
2683msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2684#
2685# code: SUN4U-8005-7Q
2686# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
2687#
2688msgid "SUN4U-8005-7Q.type"
2689msgstr "Fault"
2690msgid "SUN4U-8005-7Q.severity"
2691msgstr "Critical"
2692msgid "SUN4U-8005-7Q.description"
2693msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2694msgid "SUN4U-8005-7Q.response"
2695msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2696msgid "SUN4U-8005-7Q.impact"
2697msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2698msgid "SUN4U-8005-7Q.action"
2699msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2700#
2701# code: SUN4U-8005-8Y
2702# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
2703#
2704msgid "SUN4U-8005-8Y.type"
2705msgstr "Fault"
2706msgid "SUN4U-8005-8Y.severity"
2707msgstr "Critical"
2708msgid "SUN4U-8005-8Y.description"
2709msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2710msgid "SUN4U-8005-8Y.response"
2711msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2712msgid "SUN4U-8005-8Y.impact"
2713msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2714msgid "SUN4U-8005-8Y.action"
2715msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2716#
2717# code: SUN4U-8005-93
2718# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
2719#
2720msgid "SUN4U-8005-93.type"
2721msgstr "Fault"
2722msgid "SUN4U-8005-93.severity"
2723msgstr "Critical"
2724msgid "SUN4U-8005-93.description"
2725msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2726msgid "SUN4U-8005-93.response"
2727msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2728msgid "SUN4U-8005-93.impact"
2729msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2730msgid "SUN4U-8005-93.action"
2731msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2732#
2733# code: SUN4U-8005-AH
2734# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2735#
2736msgid "SUN4U-8005-AH.type"
2737msgstr "Fault"
2738msgid "SUN4U-8005-AH.severity"
2739msgstr "Critical"
2740msgid "SUN4U-8005-AH.description"
2741msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2742msgid "SUN4U-8005-AH.response"
2743msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2744msgid "SUN4U-8005-AH.impact"
2745msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2746msgid "SUN4U-8005-AH.action"
2747msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2748#
2749# code: SUN4U-8005-CD
2750# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2751#
2752msgid "SUN4U-8005-CD.type"
2753msgstr "Fault"
2754msgid "SUN4U-8005-CD.severity"
2755msgstr "Critical"
2756msgid "SUN4U-8005-CD.description"
2757msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2758msgid "SUN4U-8005-CD.response"
2759msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2760msgid "SUN4U-8005-CD.impact"
2761msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2762msgid "SUN4U-8005-CD.action"
2763msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2764#
2765# code: SUN4U-8005-DP
2766# keys: fault.io.pci.device fault.io.psycho
2767#
2768msgid "SUN4U-8005-DP.type"
2769msgstr "Fault"
2770msgid "SUN4U-8005-DP.severity"
2771msgstr "Critical"
2772msgid "SUN4U-8005-DP.description"
2773msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2774msgid "SUN4U-8005-DP.response"
2775msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2776msgid "SUN4U-8005-DP.impact"
2777msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2778msgid "SUN4U-8005-DP.action"
2779msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2780#
2781# code: SUN4U-8005-EA
2782# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
2783#
2784msgid "SUN4U-8005-EA.type"
2785msgstr "Fault"
2786msgid "SUN4U-8005-EA.severity"
2787msgstr "Critical"
2788msgid "SUN4U-8005-EA.description"
2789msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2790msgid "SUN4U-8005-EA.response"
2791msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2792msgid "SUN4U-8005-EA.impact"
2793msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2794msgid "SUN4U-8005-EA.action"
2795msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2796#
2797# code: SUN4U-8005-FS
2798# keys: fault.io.datapath fault.io.pci.device fault.io.psycho
2799#
2800msgid "SUN4U-8005-FS.type"
2801msgstr "Fault"
2802msgid "SUN4U-8005-FS.severity"
2803msgstr "Critical"
2804msgid "SUN4U-8005-FS.description"
2805msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2806msgid "SUN4U-8005-FS.response"
2807msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2808msgid "SUN4U-8005-FS.impact"
2809msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2810msgid "SUN4U-8005-FS.action"
2811msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2812#
2813# code: SUN4U-8005-G5
2814# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
2815#
2816msgid "SUN4U-8005-G5.type"
2817msgstr "Fault"
2818msgid "SUN4U-8005-G5.severity"
2819msgstr "Critical"
2820msgid "SUN4U-8005-G5.description"
2821msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2822msgid "SUN4U-8005-G5.response"
2823msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2824msgid "SUN4U-8005-G5.impact"
2825msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2826msgid "SUN4U-8005-G5.action"
2827msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2828#
2829# code: SUN4U-8005-HX
2830# keys: fault.io.hbus fault.io.pci.device fault.io.psycho
2831#
2832msgid "SUN4U-8005-HX.type"
2833msgstr "Fault"
2834msgid "SUN4U-8005-HX.severity"
2835msgstr "Critical"
2836msgid "SUN4U-8005-HX.description"
2837msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2838msgid "SUN4U-8005-HX.response"
2839msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2840msgid "SUN4U-8005-HX.impact"
2841msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2842msgid "SUN4U-8005-HX.action"
2843msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2844#
2845# code: SUN4U-8005-J2
2846# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
2847#
2848msgid "SUN4U-8005-J2.type"
2849msgstr "Fault"
2850msgid "SUN4U-8005-J2.severity"
2851msgstr "Critical"
2852msgid "SUN4U-8005-J2.description"
2853msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2854msgid "SUN4U-8005-J2.response"
2855msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2856msgid "SUN4U-8005-J2.impact"
2857msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2858msgid "SUN4U-8005-J2.action"
2859msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2860#
2861# code: SUN4U-8005-KJ
2862# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2863#
2864msgid "SUN4U-8005-KJ.type"
2865msgstr "Fault"
2866msgid "SUN4U-8005-KJ.severity"
2867msgstr "Critical"
2868msgid "SUN4U-8005-KJ.description"
2869msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2870msgid "SUN4U-8005-KJ.response"
2871msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2872msgid "SUN4U-8005-KJ.impact"
2873msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2874msgid "SUN4U-8005-KJ.action"
2875msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2876#
2877# code: SUN4U-8005-LE
2878# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2879#
2880msgid "SUN4U-8005-LE.type"
2881msgstr "Fault"
2882msgid "SUN4U-8005-LE.severity"
2883msgstr "Critical"
2884msgid "SUN4U-8005-LE.description"
2885msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2886msgid "SUN4U-8005-LE.response"
2887msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2888msgid "SUN4U-8005-LE.impact"
2889msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2890msgid "SUN4U-8005-LE.action"
2891msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2892#
2893# code: SUN4U-8005-MQ
2894# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
2895#
2896msgid "SUN4U-8005-MQ.type"
2897msgstr "Fault"
2898msgid "SUN4U-8005-MQ.severity"
2899msgstr "Critical"
2900msgid "SUN4U-8005-MQ.description"
2901msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2902msgid "SUN4U-8005-MQ.response"
2903msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2904msgid "SUN4U-8005-MQ.impact"
2905msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2906msgid "SUN4U-8005-MQ.action"
2907msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2908#
2909# code: SUN4U-8005-NC
2910# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
2911#
2912msgid "SUN4U-8005-NC.type"
2913msgstr "Fault"
2914msgid "SUN4U-8005-NC.severity"
2915msgstr "Critical"
2916msgid "SUN4U-8005-NC.description"
2917msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2918msgid "SUN4U-8005-NC.response"
2919msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2920msgid "SUN4U-8005-NC.impact"
2921msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2922msgid "SUN4U-8005-NC.action"
2923msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2924#
2925# code: SUN4U-8005-PR
2926# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2927#
2928msgid "SUN4U-8005-PR.type"
2929msgstr "Fault"
2930msgid "SUN4U-8005-PR.severity"
2931msgstr "Critical"
2932msgid "SUN4U-8005-PR.description"
2933msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2934msgid "SUN4U-8005-PR.response"
2935msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2936msgid "SUN4U-8005-PR.impact"
2937msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2938msgid "SUN4U-8005-PR.action"
2939msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2940#
2941# code: SUN4U-8005-Q4
2942# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2943#
2944msgid "SUN4U-8005-Q4.type"
2945msgstr "Fault"
2946msgid "SUN4U-8005-Q4.severity"
2947msgstr "Critical"
2948msgid "SUN4U-8005-Q4.description"
2949msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2950msgid "SUN4U-8005-Q4.response"
2951msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2952msgid "SUN4U-8005-Q4.impact"
2953msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2954msgid "SUN4U-8005-Q4.action"
2955msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2956#
2957# code: SUN4U-8005-RD
2958# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2959#
2960msgid "SUN4U-8005-RD.type"
2961msgstr "Fault"
2962msgid "SUN4U-8005-RD.severity"
2963msgstr "Critical"
2964msgid "SUN4U-8005-RD.description"
2965msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2966msgid "SUN4U-8005-RD.response"
2967msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2968msgid "SUN4U-8005-RD.impact"
2969msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2970msgid "SUN4U-8005-RD.action"
2971msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2972#
2973# code: SUN4U-8005-SH
2974# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2975#
2976msgid "SUN4U-8005-SH.type"
2977msgstr "Fault"
2978msgid "SUN4U-8005-SH.severity"
2979msgstr "Critical"
2980msgid "SUN4U-8005-SH.description"
2981msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
2982msgid "SUN4U-8005-SH.response"
2983msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
2984msgid "SUN4U-8005-SH.impact"
2985msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
2986msgid "SUN4U-8005-SH.action"
2987msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
2988#
2989# code: SUN4U-8005-T3
2990# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2991#
2992msgid "SUN4U-8005-T3.type"
2993msgstr "Fault"
2994msgid "SUN4U-8005-T3.severity"
2995msgstr "Critical"
2996msgid "SUN4U-8005-T3.description"
2997msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
2998msgid "SUN4U-8005-T3.response"
2999msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3000msgid "SUN4U-8005-T3.impact"
3001msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3002msgid "SUN4U-8005-T3.action"
3003msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3004#
3005# code: SUN4U-8005-UY
3006# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
3007#
3008msgid "SUN4U-8005-UY.type"
3009msgstr "Fault"
3010msgid "SUN4U-8005-UY.severity"
3011msgstr "Critical"
3012msgid "SUN4U-8005-UY.description"
3013msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3014msgid "SUN4U-8005-UY.response"
3015msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3016msgid "SUN4U-8005-UY.impact"
3017msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3018msgid "SUN4U-8005-UY.action"
3019msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3020#
3021# code: SUN4U-8005-V5
3022# keys: fault.io.tomatillo
3023#
3024msgid "SUN4U-8005-V5.type"
3025msgstr "Fault"
3026msgid "SUN4U-8005-V5.severity"
3027msgstr "Critical"
3028msgid "SUN4U-8005-V5.description"
3029msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3030msgid "SUN4U-8005-V5.response"
3031msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3032msgid "SUN4U-8005-V5.impact"
3033msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3034msgid "SUN4U-8005-V5.action"
3035msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3036#
3037# code: SUN4U-8005-WS
3038# keys: defect.io.pci.driver fault.io.tomatillo
3039#
3040msgid "SUN4U-8005-WS.type"
3041msgstr "Fault"
3042msgid "SUN4U-8005-WS.severity"
3043msgstr "Critical"
3044msgid "SUN4U-8005-WS.description"
3045msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3046msgid "SUN4U-8005-WS.response"
3047msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3048msgid "SUN4U-8005-WS.impact"
3049msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3050msgid "SUN4U-8005-WS.action"
3051msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3052#
3053# code: SUN4U-8005-XA
3054# keys: fault.io.datapath fault.io.tomatillo
3055#
3056msgid "SUN4U-8005-XA.type"
3057msgstr "Fault"
3058msgid "SUN4U-8005-XA.severity"
3059msgstr "Critical"
3060msgid "SUN4U-8005-XA.description"
3061msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3062msgid "SUN4U-8005-XA.response"
3063msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3064msgid "SUN4U-8005-XA.impact"
3065msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3066msgid "SUN4U-8005-XA.action"
3067msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3068#
3069# code: SUN4U-8005-YP
3070# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
3071#
3072msgid "SUN4U-8005-YP.type"
3073msgstr "Fault"
3074msgid "SUN4U-8005-YP.severity"
3075msgstr "Critical"
3076msgid "SUN4U-8005-YP.description"
3077msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3078msgid "SUN4U-8005-YP.response"
3079msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3080msgid "SUN4U-8005-YP.impact"
3081msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3082msgid "SUN4U-8005-YP.action"
3083msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3084#
3085# code: SUN4U-8006-04
3086# keys: fault.io.hbus fault.io.tomatillo
3087#
3088msgid "SUN4U-8006-04.type"
3089msgstr "Fault"
3090msgid "SUN4U-8006-04.severity"
3091msgstr "Critical"
3092msgid "SUN4U-8006-04.description"
3093msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3094msgid "SUN4U-8006-04.response"
3095msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3096msgid "SUN4U-8006-04.impact"
3097msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3098msgid "SUN4U-8006-04.action"
3099msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3100#
3101# code: SUN4U-8006-1R
3102# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
3103#
3104msgid "SUN4U-8006-1R.type"
3105msgstr "Fault"
3106msgid "SUN4U-8006-1R.severity"
3107msgstr "Critical"
3108msgid "SUN4U-8006-1R.description"
3109msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3110msgid "SUN4U-8006-1R.response"
3111msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3112msgid "SUN4U-8006-1R.impact"
3113msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3114msgid "SUN4U-8006-1R.action"
3115msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3116#
3117# code: SUN4U-8006-2C
3118# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
3119#
3120msgid "SUN4U-8006-2C.type"
3121msgstr "Fault"
3122msgid "SUN4U-8006-2C.severity"
3123msgstr "Critical"
3124msgid "SUN4U-8006-2C.description"
3125msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3126msgid "SUN4U-8006-2C.response"
3127msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3128msgid "SUN4U-8006-2C.impact"
3129msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3130msgid "SUN4U-8006-2C.action"
3131msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3132#
3133# code: SUN4U-8006-3Q
3134# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
3135#
3136msgid "SUN4U-8006-3Q.type"
3137msgstr "Fault"
3138msgid "SUN4U-8006-3Q.severity"
3139msgstr "Critical"
3140msgid "SUN4U-8006-3Q.description"
3141msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3142msgid "SUN4U-8006-3Q.response"
3143msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3144msgid "SUN4U-8006-3Q.impact"
3145msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3146msgid "SUN4U-8006-3Q.action"
3147msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3148#
3149# code: SUN4U-8006-4E
3150# keys: fault.io.pci.bus fault.io.tomatillo
3151#
3152msgid "SUN4U-8006-4E.type"
3153msgstr "Fault"
3154msgid "SUN4U-8006-4E.severity"
3155msgstr "Critical"
3156msgid "SUN4U-8006-4E.description"
3157msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3158msgid "SUN4U-8006-4E.response"
3159msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3160msgid "SUN4U-8006-4E.impact"
3161msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3162msgid "SUN4U-8006-4E.action"
3163msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3164#
3165# code: SUN4U-8006-5J
3166# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
3167#
3168msgid "SUN4U-8006-5J.type"
3169msgstr "Fault"
3170msgid "SUN4U-8006-5J.severity"
3171msgstr "Critical"
3172msgid "SUN4U-8006-5J.description"
3173msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3174msgid "SUN4U-8006-5J.response"
3175msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3176msgid "SUN4U-8006-5J.impact"
3177msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3178msgid "SUN4U-8006-5J.action"
3179msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3180#
3181# code: SUN4U-8006-62
3182# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3183#
3184msgid "SUN4U-8006-62.type"
3185msgstr "Fault"
3186msgid "SUN4U-8006-62.severity"
3187msgstr "Critical"
3188msgid "SUN4U-8006-62.description"
3189msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3190msgid "SUN4U-8006-62.response"
3191msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3192msgid "SUN4U-8006-62.impact"
3193msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3194msgid "SUN4U-8006-62.action"
3195msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3196#
3197# code: SUN4U-8006-7X
3198# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3199#
3200msgid "SUN4U-8006-7X.type"
3201msgstr "Fault"
3202msgid "SUN4U-8006-7X.severity"
3203msgstr "Critical"
3204msgid "SUN4U-8006-7X.description"
3205msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3206msgid "SUN4U-8006-7X.response"
3207msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3208msgid "SUN4U-8006-7X.impact"
3209msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3210msgid "SUN4U-8006-7X.action"
3211msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3212#
3213# code: SUN4U-8006-8P
3214# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3215#
3216msgid "SUN4U-8006-8P.type"
3217msgstr "Fault"
3218msgid "SUN4U-8006-8P.severity"
3219msgstr "Critical"
3220msgid "SUN4U-8006-8P.description"
3221msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3222msgid "SUN4U-8006-8P.response"
3223msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3224msgid "SUN4U-8006-8P.impact"
3225msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3226msgid "SUN4U-8006-8P.action"
3227msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3228#
3229# code: SUN4U-8006-9A
3230# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3231#
3232msgid "SUN4U-8006-9A.type"
3233msgstr "Fault"
3234msgid "SUN4U-8006-9A.severity"
3235msgstr "Critical"
3236msgid "SUN4U-8006-9A.description"
3237msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3238msgid "SUN4U-8006-9A.response"
3239msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3240msgid "SUN4U-8006-9A.impact"
3241msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3242msgid "SUN4U-8006-9A.action"
3243msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3244#
3245# code: SUN4U-8006-AS
3246# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3247#
3248msgid "SUN4U-8006-AS.type"
3249msgstr "Fault"
3250msgid "SUN4U-8006-AS.severity"
3251msgstr "Critical"
3252msgid "SUN4U-8006-AS.description"
3253msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3254msgid "SUN4U-8006-AS.response"
3255msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3256msgid "SUN4U-8006-AS.impact"
3257msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3258msgid "SUN4U-8006-AS.action"
3259msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3260#
3261# code: SUN4U-8006-C5
3262# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3263#
3264msgid "SUN4U-8006-C5.type"
3265msgstr "Fault"
3266msgid "SUN4U-8006-C5.severity"
3267msgstr "Critical"
3268msgid "SUN4U-8006-C5.description"
3269msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3270msgid "SUN4U-8006-C5.response"
3271msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3272msgid "SUN4U-8006-C5.impact"
3273msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3274msgid "SUN4U-8006-C5.action"
3275msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3276#
3277# code: SUN4U-8006-DY
3278# keys: fault.io.pci.device fault.io.tomatillo
3279#
3280msgid "SUN4U-8006-DY.type"
3281msgstr "Fault"
3282msgid "SUN4U-8006-DY.severity"
3283msgstr "Critical"
3284msgid "SUN4U-8006-DY.description"
3285msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3286msgid "SUN4U-8006-DY.response"
3287msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3288msgid "SUN4U-8006-DY.impact"
3289msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3290msgid "SUN4U-8006-DY.action"
3291msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3292#
3293# code: SUN4U-8006-E3
3294# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
3295#
3296msgid "SUN4U-8006-E3.type"
3297msgstr "Fault"
3298msgid "SUN4U-8006-E3.severity"
3299msgstr "Critical"
3300msgid "SUN4U-8006-E3.description"
3301msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3302msgid "SUN4U-8006-E3.response"
3303msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3304msgid "SUN4U-8006-E3.impact"
3305msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3306msgid "SUN4U-8006-E3.action"
3307msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3308#
3309# code: SUN4U-8006-FH
3310# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
3311#
3312msgid "SUN4U-8006-FH.type"
3313msgstr "Fault"
3314msgid "SUN4U-8006-FH.severity"
3315msgstr "Critical"
3316msgid "SUN4U-8006-FH.description"
3317msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3318msgid "SUN4U-8006-FH.response"
3319msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3320msgid "SUN4U-8006-FH.impact"
3321msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3322msgid "SUN4U-8006-FH.action"
3323msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3324#
3325# code: SUN4U-8006-GD
3326# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
3327#
3328msgid "SUN4U-8006-GD.type"
3329msgstr "Fault"
3330msgid "SUN4U-8006-GD.severity"
3331msgstr "Critical"
3332msgid "SUN4U-8006-GD.description"
3333msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3334msgid "SUN4U-8006-GD.response"
3335msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3336msgid "SUN4U-8006-GD.impact"
3337msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3338msgid "SUN4U-8006-GD.action"
3339msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3340#
3341# code: SUN4U-8006-HQ
3342# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
3343#
3344msgid "SUN4U-8006-HQ.type"
3345msgstr "Fault"
3346msgid "SUN4U-8006-HQ.severity"
3347msgstr "Critical"
3348msgid "SUN4U-8006-HQ.description"
3349msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3350msgid "SUN4U-8006-HQ.response"
3351msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3352msgid "SUN4U-8006-HQ.impact"
3353msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3354msgid "SUN4U-8006-HQ.action"
3355msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3356#
3357# code: SUN4U-8006-JC
3358# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
3359#
3360msgid "SUN4U-8006-JC.type"
3361msgstr "Fault"
3362msgid "SUN4U-8006-JC.severity"
3363msgstr "Critical"
3364msgid "SUN4U-8006-JC.description"
3365msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3366msgid "SUN4U-8006-JC.response"
3367msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3368msgid "SUN4U-8006-JC.impact"
3369msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3370msgid "SUN4U-8006-JC.action"
3371msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3372#
3373# code: SUN4U-8006-KR
3374# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3375#
3376msgid "SUN4U-8006-KR.type"
3377msgstr "Fault"
3378msgid "SUN4U-8006-KR.severity"
3379msgstr "Critical"
3380msgid "SUN4U-8006-KR.description"
3381msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3382msgid "SUN4U-8006-KR.response"
3383msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3384msgid "SUN4U-8006-KR.impact"
3385msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3386msgid "SUN4U-8006-KR.action"
3387msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3388#
3389# code: SUN4U-8006-L4
3390# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3391#
3392msgid "SUN4U-8006-L4.type"
3393msgstr "Fault"
3394msgid "SUN4U-8006-L4.severity"
3395msgstr "Critical"
3396msgid "SUN4U-8006-L4.description"
3397msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3398msgid "SUN4U-8006-L4.response"
3399msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3400msgid "SUN4U-8006-L4.impact"
3401msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3402msgid "SUN4U-8006-L4.action"
3403msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3404#
3405# code: SUN4U-8006-MX
3406# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3407#
3408msgid "SUN4U-8006-MX.type"
3409msgstr "Fault"
3410msgid "SUN4U-8006-MX.severity"
3411msgstr "Critical"
3412msgid "SUN4U-8006-MX.description"
3413msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3414msgid "SUN4U-8006-MX.response"
3415msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3416msgid "SUN4U-8006-MX.impact"
3417msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3418msgid "SUN4U-8006-MX.action"
3419msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3420#
3421# code: SUN4U-8006-N2
3422# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3423#
3424msgid "SUN4U-8006-N2.type"
3425msgstr "Fault"
3426msgid "SUN4U-8006-N2.severity"
3427msgstr "Critical"
3428msgid "SUN4U-8006-N2.description"
3429msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3430msgid "SUN4U-8006-N2.response"
3431msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3432msgid "SUN4U-8006-N2.impact"
3433msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3434msgid "SUN4U-8006-N2.action"
3435msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3436#
3437# code: SUN4U-8006-PJ
3438# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3439#
3440msgid "SUN4U-8006-PJ.type"
3441msgstr "Fault"
3442msgid "SUN4U-8006-PJ.severity"
3443msgstr "Critical"
3444msgid "SUN4U-8006-PJ.description"
3445msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3446msgid "SUN4U-8006-PJ.response"
3447msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3448msgid "SUN4U-8006-PJ.impact"
3449msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3450msgid "SUN4U-8006-PJ.action"
3451msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3452#
3453# code: SUN4U-8006-QE
3454# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3455#
3456msgid "SUN4U-8006-QE.type"
3457msgstr "Fault"
3458msgid "SUN4U-8006-QE.severity"
3459msgstr "Critical"
3460msgid "SUN4U-8006-QE.description"
3461msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3462msgid "SUN4U-8006-QE.response"
3463msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3464msgid "SUN4U-8006-QE.impact"
3465msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3466msgid "SUN4U-8006-QE.action"
3467msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3468#
3469# code: SUN4U-8006-R5
3470# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3471#
3472msgid "SUN4U-8006-R5.type"
3473msgstr "Fault"
3474msgid "SUN4U-8006-R5.severity"
3475msgstr "Critical"
3476msgid "SUN4U-8006-R5.description"
3477msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3478msgid "SUN4U-8006-R5.response"
3479msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3480msgid "SUN4U-8006-R5.impact"
3481msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3482msgid "SUN4U-8006-R5.action"
3483msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3484#
3485# code: SUN4U-8006-SS
3486# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3487#
3488msgid "SUN4U-8006-SS.type"
3489msgstr "Fault"
3490msgid "SUN4U-8006-SS.severity"
3491msgstr "Critical"
3492msgid "SUN4U-8006-SS.description"
3493msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3494msgid "SUN4U-8006-SS.response"
3495msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3496msgid "SUN4U-8006-SS.impact"
3497msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3498msgid "SUN4U-8006-SS.action"
3499msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3500#
3501# code: SUN4U-8006-TA
3502# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3503#
3504msgid "SUN4U-8006-TA.type"
3505msgstr "Fault"
3506msgid "SUN4U-8006-TA.severity"
3507msgstr "Critical"
3508msgid "SUN4U-8006-TA.description"
3509msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
3510msgid "SUN4U-8006-TA.response"
3511msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3512msgid "SUN4U-8006-TA.impact"
3513msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3514msgid "SUN4U-8006-TA.action"
3515msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
3516#
3517# code: SUN4U-8006-UP
3518# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3519#
3520msgid "SUN4U-8006-UP.type"
3521msgstr "Fault"
3522msgid "SUN4U-8006-UP.severity"
3523msgstr "Critical"
3524msgid "SUN4U-8006-UP.description"
3525msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
3526msgid "SUN4U-8006-UP.response"
3527msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3528msgid "SUN4U-8006-UP.impact"
3529msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3530msgid "SUN4U-8006-UP.action"
3531msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
3532#
3533# code: SUN4U-8006-VD
3534# keys: fault.cpu.ultraSPARC-IIIiplus.dcache
3535#
3536msgid "SUN4U-8006-VD.type"
3537msgstr "Fault"
3538msgid "SUN4U-8006-VD.severity"
3539msgstr "Major"
3540msgid "SUN4U-8006-VD.description"
3541msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3542msgid "SUN4U-8006-VD.response"
3543msgstr "The fault manager will attempt to remove the affected CPU from service."
3544msgid "SUN4U-8006-VD.impact"
3545msgstr "System performance may be affected."
3546msgid "SUN4U-8006-VD.action"
3547msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3548#
3549# code: SUN4U-8006-WH
3550# keys: fault.cpu.ultraSPARC-IIIiplus.icache
3551#
3552msgid "SUN4U-8006-WH.type"
3553msgstr "Fault"
3554msgid "SUN4U-8006-WH.severity"
3555msgstr "Major"
3556msgid "SUN4U-8006-WH.description"
3557msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3558msgid "SUN4U-8006-WH.response"
3559msgstr "The fault manager will attempt to remove the affected CPU from service."
3560msgid "SUN4U-8006-WH.impact"
3561msgstr "System performance may be affected."
3562msgid "SUN4U-8006-WH.action"
3563msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3564#
3565# code: SUN4U-8006-X3
3566# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
3567#
3568msgid "SUN4U-8006-X3.type"
3569msgstr "Fault"
3570msgid "SUN4U-8006-X3.severity"
3571msgstr "Major"
3572msgid "SUN4U-8006-X3.description"
3573msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3574msgid "SUN4U-8006-X3.response"
3575msgstr "The fault manager will attempt to remove the affected CPU from service."
3576msgid "SUN4U-8006-X3.impact"
3577msgstr "System performance may be affected."
3578msgid "SUN4U-8006-X3.action"
3579msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3580#
3581# code: SUN4U-8006-YY
3582# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
3583#
3584msgid "SUN4U-8006-YY.type"
3585msgstr "Fault"
3586msgid "SUN4U-8006-YY.severity"
3587msgstr "Major"
3588msgid "SUN4U-8006-YY.description"
3589msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3590msgid "SUN4U-8006-YY.response"
3591msgstr "The fault manager will attempt to remove the affected CPU from service."
3592msgid "SUN4U-8006-YY.impact"
3593msgstr "System performance may be affected."
3594msgid "SUN4U-8006-YY.action"
3595msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3596#
3597# code: SUN4U-8007-03
3598# keys: fault.cpu.ultraSPARC-IIIiplus.fpu
3599#
3600msgid "SUN4U-8007-03.type"
3601msgstr "Fault"
3602msgid "SUN4U-8007-03.severity"
3603msgstr "Major"
3604msgid "SUN4U-8007-03.description"
3605msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
3606msgid "SUN4U-8007-03.response"
3607msgstr "The fault manager will attempt to remove the affected CPU from service."
3608msgid "SUN4U-8007-03.impact"
3609msgstr "System performance may be affected."
3610msgid "SUN4U-8007-03.action"
3611msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3612#
3613# code: SUN4U-8007-1Y
3614# keys: fault.asic.cds.dp
3615#
3616msgid "SUN4U-8007-1Y.type"
3617msgstr "Fault"
3618msgid "SUN4U-8007-1Y.severity"
3619msgstr "Critical"
3620msgid "SUN4U-8007-1Y.description"
3621msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3622msgid "SUN4U-8007-1Y.response"
3623msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3624msgid "SUN4U-8007-1Y.impact"
3625msgstr "System performace may be affected.\n"
3626msgid "SUN4U-8007-1Y.action"
3627msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3628#
3629# code: SUN4U-8007-2D
3630# keys: fault.asic.dx.dp
3631#
3632msgid "SUN4U-8007-2D.type"
3633msgstr "Fault"
3634msgid "SUN4U-8007-2D.severity"
3635msgstr "Critical"
3636msgid "SUN4U-8007-2D.description"
3637msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3638msgid "SUN4U-8007-2D.response"
3639msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3640msgid "SUN4U-8007-2D.impact"
3641msgstr "System performace may be affected.\n"
3642msgid "SUN4U-8007-2D.action"
3643msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3644#
3645# code: SUN4U-8007-3H
3646# keys: fault.asic.sdi.dp
3647#
3648msgid "SUN4U-8007-3H.type"
3649msgstr "Fault"
3650msgid "SUN4U-8007-3H.severity"
3651msgstr "Critical"
3652msgid "SUN4U-8007-3H.description"
3653msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3654msgid "SUN4U-8007-3H.response"
3655msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3656msgid "SUN4U-8007-3H.impact"
3657msgstr "System performace may be affected.\n"
3658msgid "SUN4U-8007-3H.action"
3659msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3660#
3661# code: SUN4U-8007-4A
3662# keys: fault.asic.cp.dp
3663#
3664msgid "SUN4U-8007-4A.type"
3665msgstr "Fault"
3666msgid "SUN4U-8007-4A.severity"
3667msgstr "Critical"
3668msgid "SUN4U-8007-4A.description"
3669msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3670msgid "SUN4U-8007-4A.response"
3671msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3672msgid "SUN4U-8007-4A.impact"
3673msgstr "System performace may be affected.\n"
3674msgid "SUN4U-8007-4A.action"
3675msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3676#
3677# code: SUN4U-8007-5P
3678# keys: fault.asic.rp.dp
3679#
3680msgid "SUN4U-8007-5P.type"
3681msgstr "Fault"
3682msgid "SUN4U-8007-5P.severity"
3683msgstr "Critical"
3684msgid "SUN4U-8007-5P.description"
3685msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3686msgid "SUN4U-8007-5P.response"
3687msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3688msgid "SUN4U-8007-5P.impact"
3689msgstr "System performace may be affected.\n"
3690msgid "SUN4U-8007-5P.action"
3691msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3692#
3693# code: SUN4U-8007-65
3694# keys: fault.io.oberon
3695#
3696msgid "SUN4U-8007-65.type"
3697msgstr "Fault"
3698msgid "SUN4U-8007-65.severity"
3699msgstr "Critical"
3700msgid "SUN4U-8007-65.description"
3701msgstr "Oberon PCI-Express hostbridge fault\n  Refer to %s for more information."
3702msgid "SUN4U-8007-65.response"
3703msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
3704msgid "SUN4U-8007-65.impact"
3705msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
3706msgid "SUN4U-8007-65.action"
3707msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3708#
3709# code: SUN4U-8007-7S
3710# keys: fault.cpu.SPARC64-VI.chip
3711#
3712msgid "SUN4U-8007-7S.type"
3713msgstr "Fault"
3714msgid "SUN4U-8007-7S.severity"
3715msgstr "Critical"
3716msgid "SUN4U-8007-7S.description"
3717msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n  Refer to %s for more information."
3718msgid "SUN4U-8007-7S.response"
3719msgstr "An attempt will be made to remove the affected CHIP from service.\n"
3720msgid "SUN4U-8007-7S.impact"
3721msgstr "The system will not be functioning at the same performance level with the CHIP removal.\n"
3722msgid "SUN4U-8007-7S.action"
3723msgstr "Schedule a repair procedure to replace the affected CHIP.  Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP.\n"
3724#
3725# code: SUN4U-8007-8J
3726# keys: fault.cpu.SPARC64-VI.core
3727#
3728msgid "SUN4U-8007-8J.type"
3729msgstr "Fault"
3730msgid "SUN4U-8007-8J.severity"
3731msgstr "Critical"
3732msgid "SUN4U-8007-8J.description"
3733msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n  Refer to %s for more information."
3734msgid "SUN4U-8007-8J.response"
3735msgstr "An attempt will be made to remove the affected CORE from service.\n"
3736msgid "SUN4U-8007-8J.impact"
3737msgstr "The system will not be functioning at the same performance level with the CORE removal.\n"
3738msgid "SUN4U-8007-8J.action"
3739msgstr "Schedule a repair procedure to replace the affected CORE.  Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
3740#
3741# code: SUN4U-8007-9E
3742# keys: fault.cpu.SPARC64-VI.strand
3743#
3744msgid "SUN4U-8007-9E.type"
3745msgstr "Fault"
3746msgid "SUN4U-8007-9E.severity"
3747msgstr "Critical"
3748msgid "SUN4U-8007-9E.description"
3749msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information.\n  Refer to %s for more information."
3750msgid "SUN4U-8007-9E.response"
3751msgstr "An attempt will be made to remove the affected STRAND from service.\n"
3752msgid "SUN4U-8007-9E.impact"
3753msgstr "The system will not be functioning at the same performance level with the STRAND removal.\n"
3754msgid "SUN4U-8007-9E.action"
3755msgstr "Schedule a repair procedure to replace the affected STRAND.  Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
3756#
3757# code: SUN4U-8007-AX
3758# keys: fault.io.pci.device-invreq fault.io.tomatillo
3759#
3760msgid "SUN4U-8007-AX.type"
3761msgstr "Fault"
3762msgid "SUN4U-8007-AX.severity"
3763msgstr "Critical"
3764msgid "SUN4U-8007-AX.description"
3765msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
3766msgid "SUN4U-8007-AX.response"
3767msgstr "One or more device instances may be disabled\n"
3768msgid "SUN4U-8007-AX.impact"
3769msgstr "Loss of services provided by the device instances associated with this fault\n"
3770msgid "SUN4U-8007-AX.action"
3771msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmdump -v -u  to identify the devices or contact Sun for support.\n"
3772