xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4U.po (revision 7c478bd95313f5f23a4c958a745db2134aa03244)
1*7c478bd9Sstevel@tonic-gate#
2*7c478bd9Sstevel@tonic-gate# Copyright 2005 Sun Microsystems, Inc.  All rights reserved.
3*7c478bd9Sstevel@tonic-gate# Use is subject to license terms.
4*7c478bd9Sstevel@tonic-gate#
5*7c478bd9Sstevel@tonic-gate# CDDL HEADER START
6*7c478bd9Sstevel@tonic-gate#
7*7c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
8*7c478bd9Sstevel@tonic-gate# Common Development and Distribution License, Version 1.0 only
9*7c478bd9Sstevel@tonic-gate# (the "License").  You may not use this file except in compliance
10*7c478bd9Sstevel@tonic-gate# with the License.
11*7c478bd9Sstevel@tonic-gate#
12*7c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
13*7c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
14*7c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
15*7c478bd9Sstevel@tonic-gate# and limitations under the License.
16*7c478bd9Sstevel@tonic-gate#
17*7c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
18*7c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
19*7c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
20*7c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
21*7c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
22*7c478bd9Sstevel@tonic-gate#
23*7c478bd9Sstevel@tonic-gate# CDDL HEADER END
24*7c478bd9Sstevel@tonic-gate#
25*7c478bd9Sstevel@tonic-gate#ident	"%Z%%M%	%I%	%E% SMI"
26*7c478bd9Sstevel@tonic-gate
27*7c478bd9Sstevel@tonic-gate#
28*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-1A
29*7c478bd9Sstevel@tonic-gate# keys: fault.memory.page
30*7c478bd9Sstevel@tonic-gate#
31*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.type"
32*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
33*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.severity"
34*7c478bd9Sstevel@tonic-gatemsgstr "Minor"
35*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.description"
36*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
37*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.response"
38*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove this memory page from service."
39*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.impact"
40*7c478bd9Sstevel@tonic-gatemsgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
41*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.action"
42*7c478bd9Sstevel@tonic-gatemsgstr "No repair action is recommended at this time."
43*7c478bd9Sstevel@tonic-gate#
44*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-2S
45*7c478bd9Sstevel@tonic-gate# keys: fault.memory.dimm
46*7c478bd9Sstevel@tonic-gate#
47*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.type"
48*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
49*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.severity"
50*7c478bd9Sstevel@tonic-gatemsgstr "Minor"
51*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.description"
52*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
53*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.response"
54*7c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
55*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.impact"
56*7c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired."
57*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.action"
58*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module.  Use fmdump -v -u <EVENT_ID> to identify the module."
59*7c478bd9Sstevel@tonic-gate#
60*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-35
61*7c478bd9Sstevel@tonic-gate# keys: fault.memory.bank
62*7c478bd9Sstevel@tonic-gate#
63*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.type"
64*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
65*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.severity"
66*7c478bd9Sstevel@tonic-gatemsgstr "Minor"
67*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.description"
68*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
69*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.response"
70*7c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
71*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.impact"
72*7c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired."
73*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.action"
74*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module.  Use fmdump -v -u <EVENT_ID> to identify the module."
75*7c478bd9Sstevel@tonic-gate#
76*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-4Y
77*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.dcache
78*7c478bd9Sstevel@tonic-gate#
79*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.type"
80*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
81*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.severity"
82*7c478bd9Sstevel@tonic-gatemsgstr "Major"
83*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.description"
84*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
85*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.response"
86*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
87*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.impact"
88*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
89*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.action"
90*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
91*7c478bd9Sstevel@tonic-gate#
92*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-53
93*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.icache
94*7c478bd9Sstevel@tonic-gate#
95*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.type"
96*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
97*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.severity"
98*7c478bd9Sstevel@tonic-gatemsgstr "Major"
99*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.description"
100*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
101*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.response"
102*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
103*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.impact"
104*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
105*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.action"
106*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
107*7c478bd9Sstevel@tonic-gate#
108*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-6H
109*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachedata
110*7c478bd9Sstevel@tonic-gate#
111*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.type"
112*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
113*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.severity"
114*7c478bd9Sstevel@tonic-gatemsgstr "Major"
115*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.description"
116*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
117*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.response"
118*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
119*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.impact"
120*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
121*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.action"
122*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
123*7c478bd9Sstevel@tonic-gate#
124*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-7D
125*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachetag
126*7c478bd9Sstevel@tonic-gate#
127*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.type"
128*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
129*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.severity"
130*7c478bd9Sstevel@tonic-gatemsgstr "Major"
131*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.description"
132*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
133*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.response"
134*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
135*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.impact"
136*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
137*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.action"
138*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
139*7c478bd9Sstevel@tonic-gate#
140*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-84
141*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.dcache
142*7c478bd9Sstevel@tonic-gate#
143*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.type"
144*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
145*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.severity"
146*7c478bd9Sstevel@tonic-gatemsgstr "Major"
147*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.description"
148*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
149*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.response"
150*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
151*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.impact"
152*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
153*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.action"
154*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
155*7c478bd9Sstevel@tonic-gate#
156*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-9R
157*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.icache
158*7c478bd9Sstevel@tonic-gate#
159*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.type"
160*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
161*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.severity"
162*7c478bd9Sstevel@tonic-gatemsgstr "Major"
163*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.description"
164*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
165*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.response"
166*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
167*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.impact"
168*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
169*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.action"
170*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
171*7c478bd9Sstevel@tonic-gate#
172*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-AC
173*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
174*7c478bd9Sstevel@tonic-gate#
175*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.type"
176*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
177*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.severity"
178*7c478bd9Sstevel@tonic-gatemsgstr "Major"
179*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.description"
180*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
181*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.response"
182*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
183*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.impact"
184*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
185*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.action"
186*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
187*7c478bd9Sstevel@tonic-gate#
188*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-CQ
189*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
190*7c478bd9Sstevel@tonic-gate#
191*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.type"
192*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
193*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.severity"
194*7c478bd9Sstevel@tonic-gatemsgstr "Major"
195*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.description"
196*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
197*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.response"
198*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
199*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.impact"
200*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
201*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.action"
202*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
203*7c478bd9Sstevel@tonic-gate#
204*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-DE
205*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.dcache
206*7c478bd9Sstevel@tonic-gate#
207*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.type"
208*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
209*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.severity"
210*7c478bd9Sstevel@tonic-gatemsgstr "Major"
211*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.description"
212*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
213*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.response"
214*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
215*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.impact"
216*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
217*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.action"
218*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
219*7c478bd9Sstevel@tonic-gate#
220*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-EJ
221*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.icache
222*7c478bd9Sstevel@tonic-gate#
223*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.type"
224*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
225*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.severity"
226*7c478bd9Sstevel@tonic-gatemsgstr "Major"
227*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.description"
228*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
229*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.response"
230*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
231*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.impact"
232*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
233*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.action"
234*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
235*7c478bd9Sstevel@tonic-gate#
236*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-F2
237*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
238*7c478bd9Sstevel@tonic-gate#
239*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.type"
240*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
241*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.severity"
242*7c478bd9Sstevel@tonic-gatemsgstr "Major"
243*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.description"
244*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
245*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.response"
246*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
247*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.impact"
248*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
249*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.action"
250*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
251*7c478bd9Sstevel@tonic-gate#
252*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-GX
253*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
254*7c478bd9Sstevel@tonic-gate#
255*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.type"
256*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
257*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.severity"
258*7c478bd9Sstevel@tonic-gatemsgstr "Major"
259*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.description"
260*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
261*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.response"
262*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
263*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.impact"
264*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
265*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.action"
266*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
267*7c478bd9Sstevel@tonic-gate#
268*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-H5
269*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.dcache
270*7c478bd9Sstevel@tonic-gate#
271*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.type"
272*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
273*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.severity"
274*7c478bd9Sstevel@tonic-gatemsgstr "Major"
275*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.description"
276*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
277*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.response"
278*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
279*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.impact"
280*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
281*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.action"
282*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
283*7c478bd9Sstevel@tonic-gate#
284*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-JS
285*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.icache
286*7c478bd9Sstevel@tonic-gate#
287*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.type"
288*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
289*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.severity"
290*7c478bd9Sstevel@tonic-gatemsgstr "Major"
291*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.description"
292*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
293*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.response"
294*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
295*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.impact"
296*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
297*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.action"
298*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
299*7c478bd9Sstevel@tonic-gate#
300*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-KA
301*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachedata
302*7c478bd9Sstevel@tonic-gate#
303*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.type"
304*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
305*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.severity"
306*7c478bd9Sstevel@tonic-gatemsgstr "Major"
307*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.description"
308*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
309*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.response"
310*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
311*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.impact"
312*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
313*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.action"
314*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
315*7c478bd9Sstevel@tonic-gate#
316*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-LP
317*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachetag
318*7c478bd9Sstevel@tonic-gate#
319*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.type"
320*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
321*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.severity"
322*7c478bd9Sstevel@tonic-gatemsgstr "Major"
323*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.description"
324*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
325*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.response"
326*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
327*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.impact"
328*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
329*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.action"
330*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
331*7c478bd9Sstevel@tonic-gate#
332*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-MD
333*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.fpu
334*7c478bd9Sstevel@tonic-gate#
335*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.type"
336*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
337*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.severity"
338*7c478bd9Sstevel@tonic-gatemsgstr "Major"
339*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.description"
340*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
341*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.response"
342*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
343*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.impact"
344*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
345*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.action"
346*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
347*7c478bd9Sstevel@tonic-gate#
348*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-NH
349*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.fpu
350*7c478bd9Sstevel@tonic-gate#
351*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.type"
352*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
353*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.severity"
354*7c478bd9Sstevel@tonic-gatemsgstr "Major"
355*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.description"
356*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
357*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.response"
358*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
359*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.impact"
360*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
361*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.action"
362*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
363*7c478bd9Sstevel@tonic-gate#
364*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-P3
365*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.fpu
366*7c478bd9Sstevel@tonic-gate#
367*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.type"
368*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
369*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.severity"
370*7c478bd9Sstevel@tonic-gatemsgstr "Major"
371*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.description"
372*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
373*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.response"
374*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
375*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.impact"
376*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
377*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.action"
378*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
379*7c478bd9Sstevel@tonic-gate#
380*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-QY
381*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.fpu
382*7c478bd9Sstevel@tonic-gate#
383*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.type"
384*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
385*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.severity"
386*7c478bd9Sstevel@tonic-gatemsgstr "Major"
387*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.description"
388*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
389*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.response"
390*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
391*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.impact"
392*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
393*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.action"
394*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
395*7c478bd9Sstevel@tonic-gate#
396*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-RQ
397*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.fpu
398*7c478bd9Sstevel@tonic-gate#
399*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.type"
400*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
401*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.severity"
402*7c478bd9Sstevel@tonic-gatemsgstr "Major"
403*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.description"
404*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
405*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.response"
406*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
407*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.impact"
408*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
409*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.action"
410*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
411*7c478bd9Sstevel@tonic-gate#
412*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-SC
413*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dcache
414*7c478bd9Sstevel@tonic-gate#
415*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.type"
416*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
417*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.severity"
418*7c478bd9Sstevel@tonic-gatemsgstr "Major"
419*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.description"
420*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
421*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.response"
422*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
423*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.impact"
424*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
425*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.action"
426*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
427*7c478bd9Sstevel@tonic-gate#
428*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-TR
429*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.icache
430*7c478bd9Sstevel@tonic-gate#
431*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.type"
432*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
433*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.severity"
434*7c478bd9Sstevel@tonic-gatemsgstr "Major"
435*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.description"
436*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
437*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.response"
438*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
439*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.impact"
440*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
441*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.action"
442*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
443*7c478bd9Sstevel@tonic-gate#
444*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-U4
445*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.pcache
446*7c478bd9Sstevel@tonic-gate#
447*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.type"
448*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
449*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.severity"
450*7c478bd9Sstevel@tonic-gatemsgstr "Major"
451*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.description"
452*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
453*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.response"
454*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
455*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.impact"
456*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
457*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.action"
458*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
459*7c478bd9Sstevel@tonic-gate#
460*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-VX
461*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dtlb
462*7c478bd9Sstevel@tonic-gate#
463*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.type"
464*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
465*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.severity"
466*7c478bd9Sstevel@tonic-gatemsgstr "Major"
467*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.description"
468*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
469*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.response"
470*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
471*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.impact"
472*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
473*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.action"
474*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
475*7c478bd9Sstevel@tonic-gate#
476*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-W2
477*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.itlb
478*7c478bd9Sstevel@tonic-gate#
479*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.type"
480*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
481*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.severity"
482*7c478bd9Sstevel@tonic-gatemsgstr "Major"
483*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.description"
484*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
485*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.response"
486*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
487*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.impact"
488*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
489*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.action"
490*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
491*7c478bd9Sstevel@tonic-gate#
492*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-XJ
493*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
494*7c478bd9Sstevel@tonic-gate#
495*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.type"
496*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
497*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.severity"
498*7c478bd9Sstevel@tonic-gatemsgstr "Major"
499*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.description"
500*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
501*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.response"
502*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
503*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.impact"
504*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
505*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.action"
506*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
507*7c478bd9Sstevel@tonic-gate#
508*7c478bd9Sstevel@tonic-gate# code: SUN4U-8000-YE
509*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
510*7c478bd9Sstevel@tonic-gate#
511*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.type"
512*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
513*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.severity"
514*7c478bd9Sstevel@tonic-gatemsgstr "Major"
515*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.description"
516*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
517*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.response"
518*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
519*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.impact"
520*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
521*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.action"
522*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
523*7c478bd9Sstevel@tonic-gate#
524*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-0J
525*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
526*7c478bd9Sstevel@tonic-gate#
527*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.type"
528*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
529*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.severity"
530*7c478bd9Sstevel@tonic-gatemsgstr "Major"
531*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.description"
532*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
533*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.response"
534*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
535*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.impact"
536*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
537*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.action"
538*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
539*7c478bd9Sstevel@tonic-gate#
540*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-1E
541*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
542*7c478bd9Sstevel@tonic-gate#
543*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.type"
544*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
545*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.severity"
546*7c478bd9Sstevel@tonic-gatemsgstr "Major"
547*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.description"
548*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
549*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.response"
550*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
551*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.impact"
552*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
553*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.action"
554*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
555*7c478bd9Sstevel@tonic-gate#
556*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-2X
557*7c478bd9Sstevel@tonic-gate# keys: defect.ultraSPARC-II.memory.nodiag
558*7c478bd9Sstevel@tonic-gate#
559*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.type"
560*7c478bd9Sstevel@tonic-gatemsgstr "Defect"
561*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.severity"
562*7c478bd9Sstevel@tonic-gatemsgstr "Minor"
563*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.description"
564*7c478bd9Sstevel@tonic-gatemsgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information"
565*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.response"
566*7c478bd9Sstevel@tonic-gatemsgstr "The error information has been saved for examination by Sun."
567*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.impact"
568*7c478bd9Sstevel@tonic-gatemsgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
569*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.action"
570*7c478bd9Sstevel@tonic-gatemsgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
571*7c478bd9Sstevel@tonic-gate#
572*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-32
573*7c478bd9Sstevel@tonic-gate# keys: fault.memory.datapath
574*7c478bd9Sstevel@tonic-gate#
575*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.type"
576*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
577*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.severity"
578*7c478bd9Sstevel@tonic-gatemsgstr "Major"
579*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.description"
580*7c478bd9Sstevel@tonic-gatemsgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.  Refer to %s for more information."
581*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.response"
582*7c478bd9Sstevel@tonic-gatemsgstr "Error reports from the affected components will be logged for examination by Sun."
583*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.impact"
584*7c478bd9Sstevel@tonic-gatemsgstr "System performance and stability may be affected."
585*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.action"
586*7c478bd9Sstevel@tonic-gatemsgstr "Contact your service provider for further diagnosis."
587*7c478bd9Sstevel@tonic-gate#
588*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-4R
589*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath
590*7c478bd9Sstevel@tonic-gate#
591*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.type"
592*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
593*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.severity"
594*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
595*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.description"
596*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
597*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.response"
598*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
599*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.impact"
600*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
601*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.action"
602*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
603*7c478bd9Sstevel@tonic-gate#
604*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-54
605*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath
606*7c478bd9Sstevel@tonic-gate#
607*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.type"
608*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
609*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.severity"
610*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
611*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.description"
612*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
613*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.response"
614*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
615*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.impact"
616*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
617*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.action"
618*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
619*7c478bd9Sstevel@tonic-gate#
620*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-6Q
621*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus
622*7c478bd9Sstevel@tonic-gate#
623*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.type"
624*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
625*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.severity"
626*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
627*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.description"
628*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
629*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.response"
630*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
631*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.impact"
632*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
633*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.action"
634*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
635*7c478bd9Sstevel@tonic-gate#
636*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-7C
637*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
638*7c478bd9Sstevel@tonic-gate#
639*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.type"
640*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
641*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.severity"
642*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
643*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.description"
644*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
645*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.response"
646*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
647*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.impact"
648*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
649*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.action"
650*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
651*7c478bd9Sstevel@tonic-gate#
652*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-83
653*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device
654*7c478bd9Sstevel@tonic-gate#
655*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.type"
656*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
657*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.severity"
658*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
659*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.description"
660*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
661*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.response"
662*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
663*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.impact"
664*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
665*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.action"
666*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
667*7c478bd9Sstevel@tonic-gate#
668*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-9Y
669*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
670*7c478bd9Sstevel@tonic-gate#
671*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.type"
672*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
673*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.severity"
674*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
675*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.description"
676*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
677*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.response"
678*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
679*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.impact"
680*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
681*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.action"
682*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
683*7c478bd9Sstevel@tonic-gate#
684*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-AD
685*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
686*7c478bd9Sstevel@tonic-gate#
687*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.type"
688*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
689*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.severity"
690*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
691*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.description"
692*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
693*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.response"
694*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
695*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.impact"
696*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
697*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.action"
698*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
699*7c478bd9Sstevel@tonic-gate#
700*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-CH
701*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
702*7c478bd9Sstevel@tonic-gate#
703*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.type"
704*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
705*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.severity"
706*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
707*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.description"
708*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
709*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.response"
710*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
711*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.impact"
712*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
713*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.action"
714*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
715*7c478bd9Sstevel@tonic-gate#
716*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-DA
717*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus
718*7c478bd9Sstevel@tonic-gate#
719*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.type"
720*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
721*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.severity"
722*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
723*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.description"
724*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
725*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.response"
726*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
727*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.impact"
728*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
729*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.action"
730*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
731*7c478bd9Sstevel@tonic-gate#
732*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-EP
733*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus
734*7c478bd9Sstevel@tonic-gate#
735*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.type"
736*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
737*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.severity"
738*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
739*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.description"
740*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
741*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.response"
742*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
743*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.impact"
744*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
745*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.action"
746*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
747*7c478bd9Sstevel@tonic-gate#
748*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-F5
749*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus
750*7c478bd9Sstevel@tonic-gate#
751*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.type"
752*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
753*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.severity"
754*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
755*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.description"
756*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
757*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.response"
758*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
759*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.impact"
760*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
761*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.action"
762*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
763*7c478bd9Sstevel@tonic-gate#
764*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-GS
765*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
766*7c478bd9Sstevel@tonic-gate#
767*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.type"
768*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
769*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.severity"
770*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
771*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.description"
772*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
773*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.response"
774*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
775*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.impact"
776*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
777*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.action"
778*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
779*7c478bd9Sstevel@tonic-gate#
780*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-H2
781*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device
782*7c478bd9Sstevel@tonic-gate#
783*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.type"
784*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
785*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.severity"
786*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
787*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.description"
788*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
789*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.response"
790*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
791*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.impact"
792*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
793*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.action"
794*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
795*7c478bd9Sstevel@tonic-gate#
796*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-JX
797*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
798*7c478bd9Sstevel@tonic-gate#
799*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.type"
800*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
801*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.severity"
802*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
803*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.description"
804*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
805*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.response"
806*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
807*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.impact"
808*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
809*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.action"
810*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
811*7c478bd9Sstevel@tonic-gate#
812*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-KE
813*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
814*7c478bd9Sstevel@tonic-gate#
815*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.type"
816*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
817*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.severity"
818*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
819*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.description"
820*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
821*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.response"
822*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
823*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.impact"
824*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
825*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.action"
826*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
827*7c478bd9Sstevel@tonic-gate#
828*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-LJ
829*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
830*7c478bd9Sstevel@tonic-gate#
831*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.type"
832*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
833*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.severity"
834*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
835*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.description"
836*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
837*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.response"
838*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
839*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.impact"
840*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
841*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.action"
842*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
843*7c478bd9Sstevel@tonic-gate#
844*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-MC
845*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus
846*7c478bd9Sstevel@tonic-gate#
847*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.type"
848*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
849*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.severity"
850*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
851*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.description"
852*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
853*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.response"
854*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
855*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.impact"
856*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
857*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.action"
858*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
859*7c478bd9Sstevel@tonic-gate#
860*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-NQ
861*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
862*7c478bd9Sstevel@tonic-gate#
863*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.type"
864*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
865*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.severity"
866*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
867*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.description"
868*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
869*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.response"
870*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
871*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.impact"
872*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
873*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.action"
874*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
875*7c478bd9Sstevel@tonic-gate#
876*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-P4
877*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
878*7c478bd9Sstevel@tonic-gate#
879*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.type"
880*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
881*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.severity"
882*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
883*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.description"
884*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
885*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.response"
886*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
887*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.impact"
888*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
889*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.action"
890*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
891*7c478bd9Sstevel@tonic-gate#
892*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-QR
893*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
894*7c478bd9Sstevel@tonic-gate#
895*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.type"
896*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
897*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.severity"
898*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
899*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.description"
900*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
901*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.response"
902*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
903*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.impact"
904*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
905*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.action"
906*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
907*7c478bd9Sstevel@tonic-gate#
908*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-RH
909*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device
910*7c478bd9Sstevel@tonic-gate#
911*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.type"
912*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
913*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.severity"
914*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
915*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.description"
916*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
917*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.response"
918*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
919*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.impact"
920*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
921*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.action"
922*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
923*7c478bd9Sstevel@tonic-gate#
924*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-SD
925*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
926*7c478bd9Sstevel@tonic-gate#
927*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.type"
928*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
929*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.severity"
930*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
931*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.description"
932*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
933*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.response"
934*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
935*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.impact"
936*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
937*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.action"
938*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
939*7c478bd9Sstevel@tonic-gate#
940*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-TY
941*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
942*7c478bd9Sstevel@tonic-gate#
943*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.type"
944*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
945*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.severity"
946*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
947*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.description"
948*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
949*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.response"
950*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
951*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.impact"
952*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
953*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.action"
954*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
955*7c478bd9Sstevel@tonic-gate#
956*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-U3
957*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
958*7c478bd9Sstevel@tonic-gate#
959*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.type"
960*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
961*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.severity"
962*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
963*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.description"
964*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
965*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.response"
966*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
967*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.impact"
968*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
969*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.action"
970*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
971*7c478bd9Sstevel@tonic-gate#
972*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-VS
973*7c478bd9Sstevel@tonic-gate# keys: fault.io.schizo
974*7c478bd9Sstevel@tonic-gate#
975*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.type"
976*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
977*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.severity"
978*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
979*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.description"
980*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
981*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.response"
982*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
983*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.impact"
984*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
985*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.action"
986*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
987*7c478bd9Sstevel@tonic-gate#
988*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-W5
989*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo
990*7c478bd9Sstevel@tonic-gate#
991*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.type"
992*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
993*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.severity"
994*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
995*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.description"
996*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
997*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.response"
998*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
999*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.impact"
1000*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1001*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.action"
1002*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1003*7c478bd9Sstevel@tonic-gate#
1004*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-XP
1005*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo
1006*7c478bd9Sstevel@tonic-gate#
1007*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.type"
1008*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1009*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.severity"
1010*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1011*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.description"
1012*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1013*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.response"
1014*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1015*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.impact"
1016*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1017*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.action"
1018*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1019*7c478bd9Sstevel@tonic-gate#
1020*7c478bd9Sstevel@tonic-gate# code: SUN4U-8001-YA
1021*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
1022*7c478bd9Sstevel@tonic-gate#
1023*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.type"
1024*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1025*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.severity"
1026*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1027*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.description"
1028*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1029*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.response"
1030*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1031*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.impact"
1032*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1033*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.action"
1034*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1035*7c478bd9Sstevel@tonic-gate#
1036*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-0R
1037*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo
1038*7c478bd9Sstevel@tonic-gate#
1039*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.type"
1040*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1041*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.severity"
1042*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1043*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.description"
1044*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1045*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.response"
1046*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1047*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.impact"
1048*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1049*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.action"
1050*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1051*7c478bd9Sstevel@tonic-gate#
1052*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-14
1053*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
1054*7c478bd9Sstevel@tonic-gate#
1055*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.type"
1056*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1057*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.severity"
1058*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1059*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.description"
1060*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1061*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.response"
1062*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1063*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.impact"
1064*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1065*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.action"
1066*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1067*7c478bd9Sstevel@tonic-gate#
1068*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-2Q
1069*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
1070*7c478bd9Sstevel@tonic-gate#
1071*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.type"
1072*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1073*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.severity"
1074*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1075*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.description"
1076*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1077*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.response"
1078*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1079*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.impact"
1080*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1081*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.action"
1082*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1083*7c478bd9Sstevel@tonic-gate#
1084*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-3C
1085*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
1086*7c478bd9Sstevel@tonic-gate#
1087*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.type"
1088*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1089*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.severity"
1090*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1091*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.description"
1092*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1093*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.response"
1094*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1095*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.impact"
1096*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1097*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.action"
1098*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1099*7c478bd9Sstevel@tonic-gate#
1100*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-4J
1101*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo
1102*7c478bd9Sstevel@tonic-gate#
1103*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.type"
1104*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1105*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.severity"
1106*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1107*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.description"
1108*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1109*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.response"
1110*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1111*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.impact"
1112*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1113*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.action"
1114*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1115*7c478bd9Sstevel@tonic-gate#
1116*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-5E
1117*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
1118*7c478bd9Sstevel@tonic-gate#
1119*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.type"
1120*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1121*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.severity"
1122*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1123*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.description"
1124*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1125*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.response"
1126*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1127*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.impact"
1128*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1129*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.action"
1130*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1131*7c478bd9Sstevel@tonic-gate#
1132*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-6X
1133*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
1134*7c478bd9Sstevel@tonic-gate#
1135*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.type"
1136*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1137*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.severity"
1138*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1139*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.description"
1140*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1141*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.response"
1142*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1143*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.impact"
1144*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1145*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.action"
1146*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1147*7c478bd9Sstevel@tonic-gate#
1148*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-72
1149*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
1150*7c478bd9Sstevel@tonic-gate#
1151*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.type"
1152*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1153*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.severity"
1154*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1155*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.description"
1156*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1157*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.response"
1158*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1159*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.impact"
1160*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1161*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.action"
1162*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1163*7c478bd9Sstevel@tonic-gate#
1164*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-8A
1165*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo
1166*7c478bd9Sstevel@tonic-gate#
1167*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.type"
1168*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1169*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.severity"
1170*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1171*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.description"
1172*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1173*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.response"
1174*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1175*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.impact"
1176*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1177*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.action"
1178*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1179*7c478bd9Sstevel@tonic-gate#
1180*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-9P
1181*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
1182*7c478bd9Sstevel@tonic-gate#
1183*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.type"
1184*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1185*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.severity"
1186*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1187*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.description"
1188*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1189*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.response"
1190*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1191*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.impact"
1192*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1193*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.action"
1194*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1195*7c478bd9Sstevel@tonic-gate#
1196*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-A5
1197*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1198*7c478bd9Sstevel@tonic-gate#
1199*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.type"
1200*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1201*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.severity"
1202*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1203*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.description"
1204*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1205*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.response"
1206*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1207*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.impact"
1208*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1209*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.action"
1210*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1211*7c478bd9Sstevel@tonic-gate#
1212*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-CS
1213*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
1214*7c478bd9Sstevel@tonic-gate#
1215*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.type"
1216*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1217*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.severity"
1218*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1219*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.description"
1220*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1221*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.response"
1222*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1223*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.impact"
1224*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1225*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.action"
1226*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1227*7c478bd9Sstevel@tonic-gate#
1228*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-D3
1229*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo
1230*7c478bd9Sstevel@tonic-gate#
1231*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.type"
1232*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1233*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.severity"
1234*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1235*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.description"
1236*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1237*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.response"
1238*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1239*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.impact"
1240*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1241*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.action"
1242*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1243*7c478bd9Sstevel@tonic-gate#
1244*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-EY
1245*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
1246*7c478bd9Sstevel@tonic-gate#
1247*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.type"
1248*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1249*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.severity"
1250*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1251*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.description"
1252*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1253*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.response"
1254*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1255*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.impact"
1256*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1257*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.action"
1258*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1259*7c478bd9Sstevel@tonic-gate#
1260*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-FD
1261*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
1262*7c478bd9Sstevel@tonic-gate#
1263*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.type"
1264*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1265*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.severity"
1266*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1267*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.description"
1268*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1269*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.response"
1270*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1271*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.impact"
1272*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1273*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.action"
1274*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1275*7c478bd9Sstevel@tonic-gate#
1276*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-GH
1277*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
1278*7c478bd9Sstevel@tonic-gate#
1279*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.type"
1280*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1281*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.severity"
1282*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1283*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.description"
1284*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1285*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.response"
1286*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1287*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.impact"
1288*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1289*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.action"
1290*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1291*7c478bd9Sstevel@tonic-gate#
1292*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-HC
1293*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo
1294*7c478bd9Sstevel@tonic-gate#
1295*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.type"
1296*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1297*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.severity"
1298*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1299*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.description"
1300*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1301*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.response"
1302*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1303*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.impact"
1304*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1305*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.action"
1306*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1307*7c478bd9Sstevel@tonic-gate#
1308*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-JQ
1309*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
1310*7c478bd9Sstevel@tonic-gate#
1311*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.type"
1312*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1313*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.severity"
1314*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1315*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.description"
1316*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1317*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.response"
1318*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1319*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.impact"
1320*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1321*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.action"
1322*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1323*7c478bd9Sstevel@tonic-gate#
1324*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-K4
1325*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1326*7c478bd9Sstevel@tonic-gate#
1327*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.type"
1328*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1329*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.severity"
1330*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1331*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.description"
1332*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1333*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.response"
1334*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1335*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.impact"
1336*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1337*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.action"
1338*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1339*7c478bd9Sstevel@tonic-gate#
1340*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-LR
1341*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1342*7c478bd9Sstevel@tonic-gate#
1343*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.type"
1344*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1345*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.severity"
1346*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1347*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.description"
1348*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1349*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.response"
1350*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1351*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.impact"
1352*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1353*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.action"
1354*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1355*7c478bd9Sstevel@tonic-gate#
1356*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-M2
1357*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo
1358*7c478bd9Sstevel@tonic-gate#
1359*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.type"
1360*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1361*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.severity"
1362*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1363*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.description"
1364*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1365*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.response"
1366*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1367*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.impact"
1368*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1369*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.action"
1370*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1371*7c478bd9Sstevel@tonic-gate#
1372*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-NX
1373*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
1374*7c478bd9Sstevel@tonic-gate#
1375*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.type"
1376*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1377*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.severity"
1378*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1379*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.description"
1380*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1381*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.response"
1382*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1383*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.impact"
1384*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1385*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.action"
1386*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1387*7c478bd9Sstevel@tonic-gate#
1388*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-PE
1389*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1390*7c478bd9Sstevel@tonic-gate#
1391*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.type"
1392*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1393*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.severity"
1394*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1395*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.description"
1396*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1397*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.response"
1398*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1399*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.impact"
1400*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1401*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.action"
1402*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1403*7c478bd9Sstevel@tonic-gate#
1404*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-QJ
1405*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
1406*7c478bd9Sstevel@tonic-gate#
1407*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.type"
1408*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1409*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.severity"
1410*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1411*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.description"
1412*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1413*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.response"
1414*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1415*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.impact"
1416*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1417*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.action"
1418*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1419*7c478bd9Sstevel@tonic-gate#
1420*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-RS
1421*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1422*7c478bd9Sstevel@tonic-gate#
1423*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.type"
1424*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1425*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.severity"
1426*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1427*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.description"
1428*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1429*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.response"
1430*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1431*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.impact"
1432*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1433*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.action"
1434*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1435*7c478bd9Sstevel@tonic-gate#
1436*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-S5
1437*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
1438*7c478bd9Sstevel@tonic-gate#
1439*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.type"
1440*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1441*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.severity"
1442*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1443*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.description"
1444*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1445*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.response"
1446*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1447*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.impact"
1448*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1449*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.action"
1450*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1451*7c478bd9Sstevel@tonic-gate#
1452*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-TP
1453*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1454*7c478bd9Sstevel@tonic-gate#
1455*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.type"
1456*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1457*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.severity"
1458*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1459*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.description"
1460*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1461*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.response"
1462*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1463*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.impact"
1464*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1465*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.action"
1466*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1467*7c478bd9Sstevel@tonic-gate#
1468*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-UA
1469*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
1470*7c478bd9Sstevel@tonic-gate#
1471*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.type"
1472*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1473*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.severity"
1474*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1475*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.description"
1476*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1477*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.response"
1478*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1479*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.impact"
1480*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1481*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.action"
1482*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1483*7c478bd9Sstevel@tonic-gate#
1484*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-VH
1485*7c478bd9Sstevel@tonic-gate# keys: fault.io.xmits
1486*7c478bd9Sstevel@tonic-gate#
1487*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.type"
1488*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1489*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.severity"
1490*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1491*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.description"
1492*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1493*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.response"
1494*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1495*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.impact"
1496*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1497*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.action"
1498*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1499*7c478bd9Sstevel@tonic-gate#
1500*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-WD
1501*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.xmits
1502*7c478bd9Sstevel@tonic-gate#
1503*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.type"
1504*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1505*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.severity"
1506*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1507*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.description"
1508*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1509*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.response"
1510*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1511*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.impact"
1512*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1513*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.action"
1514*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1515*7c478bd9Sstevel@tonic-gate#
1516*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-XY
1517*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.xmits
1518*7c478bd9Sstevel@tonic-gate#
1519*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.type"
1520*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1521*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.severity"
1522*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1523*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.description"
1524*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1525*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.response"
1526*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1527*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.impact"
1528*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1529*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.action"
1530*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1531*7c478bd9Sstevel@tonic-gate#
1532*7c478bd9Sstevel@tonic-gate# code: SUN4U-8002-Y3
1533*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
1534*7c478bd9Sstevel@tonic-gate#
1535*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.type"
1536*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1537*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.severity"
1538*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1539*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.description"
1540*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1541*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.response"
1542*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1543*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.impact"
1544*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1545*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.action"
1546*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1547*7c478bd9Sstevel@tonic-gate#
1548*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-0Y
1549*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.xmits
1550*7c478bd9Sstevel@tonic-gate#
1551*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.type"
1552*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1553*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.severity"
1554*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1555*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.description"
1556*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1557*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.response"
1558*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1559*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.impact"
1560*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1561*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.action"
1562*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1563*7c478bd9Sstevel@tonic-gate#
1564*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-13
1565*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
1566*7c478bd9Sstevel@tonic-gate#
1567*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.type"
1568*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1569*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.severity"
1570*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1571*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.description"
1572*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1573*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.response"
1574*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1575*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.impact"
1576*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1577*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.action"
1578*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1579*7c478bd9Sstevel@tonic-gate#
1580*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-2H
1581*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
1582*7c478bd9Sstevel@tonic-gate#
1583*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.type"
1584*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1585*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.severity"
1586*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1587*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.description"
1588*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1589*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.response"
1590*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1591*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.impact"
1592*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1593*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.action"
1594*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1595*7c478bd9Sstevel@tonic-gate#
1596*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-3D
1597*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
1598*7c478bd9Sstevel@tonic-gate#
1599*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.type"
1600*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1601*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.severity"
1602*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1603*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.description"
1604*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1605*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.response"
1606*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1607*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.impact"
1608*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1609*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.action"
1610*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1611*7c478bd9Sstevel@tonic-gate#
1612*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-4P
1613*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.xmits
1614*7c478bd9Sstevel@tonic-gate#
1615*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.type"
1616*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1617*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.severity"
1618*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1619*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.description"
1620*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1621*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.response"
1622*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1623*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.impact"
1624*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1625*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.action"
1626*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1627*7c478bd9Sstevel@tonic-gate#
1628*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-5A
1629*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
1630*7c478bd9Sstevel@tonic-gate#
1631*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.type"
1632*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1633*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.severity"
1634*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1635*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.description"
1636*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1637*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.response"
1638*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1639*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.impact"
1640*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1641*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.action"
1642*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1643*7c478bd9Sstevel@tonic-gate#
1644*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-6S
1645*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
1646*7c478bd9Sstevel@tonic-gate#
1647*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.type"
1648*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1649*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.severity"
1650*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1651*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.description"
1652*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1653*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.response"
1654*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1655*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.impact"
1656*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1657*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.action"
1658*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1659*7c478bd9Sstevel@tonic-gate#
1660*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-75
1661*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
1662*7c478bd9Sstevel@tonic-gate#
1663*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.type"
1664*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1665*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.severity"
1666*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1667*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.description"
1668*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1669*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.response"
1670*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1671*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.impact"
1672*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1673*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.action"
1674*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1675*7c478bd9Sstevel@tonic-gate#
1676*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-8E
1677*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.xmits
1678*7c478bd9Sstevel@tonic-gate#
1679*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.type"
1680*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1681*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.severity"
1682*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1683*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.description"
1684*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1685*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.response"
1686*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1687*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.impact"
1688*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1689*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.action"
1690*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1691*7c478bd9Sstevel@tonic-gate#
1692*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-9J
1693*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
1694*7c478bd9Sstevel@tonic-gate#
1695*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.type"
1696*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1697*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.severity"
1698*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1699*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.description"
1700*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1701*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.response"
1702*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1703*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.impact"
1704*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1705*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.action"
1706*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1707*7c478bd9Sstevel@tonic-gate#
1708*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-A2
1709*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1710*7c478bd9Sstevel@tonic-gate#
1711*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.type"
1712*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1713*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.severity"
1714*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1715*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.description"
1716*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1717*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.response"
1718*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1719*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.impact"
1720*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1721*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.action"
1722*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1723*7c478bd9Sstevel@tonic-gate#
1724*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-CX
1725*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
1726*7c478bd9Sstevel@tonic-gate#
1727*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.type"
1728*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1729*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.severity"
1730*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1731*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.description"
1732*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1733*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.response"
1734*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1735*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.impact"
1736*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1737*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.action"
1738*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1739*7c478bd9Sstevel@tonic-gate#
1740*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-D4
1741*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.xmits
1742*7c478bd9Sstevel@tonic-gate#
1743*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.type"
1744*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1745*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.severity"
1746*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1747*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.description"
1748*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1749*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.response"
1750*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1751*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.impact"
1752*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1753*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.action"
1754*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1755*7c478bd9Sstevel@tonic-gate#
1756*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-ER
1757*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
1758*7c478bd9Sstevel@tonic-gate#
1759*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.type"
1760*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1761*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.severity"
1762*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1763*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.description"
1764*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1765*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.response"
1766*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1767*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.impact"
1768*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1769*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.action"
1770*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1771*7c478bd9Sstevel@tonic-gate#
1772*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-FC
1773*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
1774*7c478bd9Sstevel@tonic-gate#
1775*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.type"
1776*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1777*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.severity"
1778*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1779*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.description"
1780*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1781*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.response"
1782*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1783*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.impact"
1784*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1785*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.action"
1786*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1787*7c478bd9Sstevel@tonic-gate#
1788*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-GQ
1789*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
1790*7c478bd9Sstevel@tonic-gate#
1791*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.type"
1792*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1793*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.severity"
1794*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1795*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.description"
1796*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1797*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.response"
1798*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1799*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.impact"
1800*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1801*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.action"
1802*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1803*7c478bd9Sstevel@tonic-gate#
1804*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-HD
1805*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.xmits
1806*7c478bd9Sstevel@tonic-gate#
1807*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.type"
1808*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1809*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.severity"
1810*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1811*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.description"
1812*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1813*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.response"
1814*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1815*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.impact"
1816*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1817*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.action"
1818*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1819*7c478bd9Sstevel@tonic-gate#
1820*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-JH
1821*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
1822*7c478bd9Sstevel@tonic-gate#
1823*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.type"
1824*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1825*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.severity"
1826*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1827*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.description"
1828*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1829*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.response"
1830*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1831*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.impact"
1832*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1833*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.action"
1834*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1835*7c478bd9Sstevel@tonic-gate#
1836*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-K3
1837*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1838*7c478bd9Sstevel@tonic-gate#
1839*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.type"
1840*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1841*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.severity"
1842*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1843*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.description"
1844*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1845*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.response"
1846*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1847*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.impact"
1848*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1849*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.action"
1850*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1851*7c478bd9Sstevel@tonic-gate#
1852*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-LY
1853*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1854*7c478bd9Sstevel@tonic-gate#
1855*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.type"
1856*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1857*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.severity"
1858*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1859*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.description"
1860*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1861*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.response"
1862*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1863*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.impact"
1864*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1865*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.action"
1866*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1867*7c478bd9Sstevel@tonic-gate#
1868*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-M5
1869*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.xmits
1870*7c478bd9Sstevel@tonic-gate#
1871*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.type"
1872*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1873*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.severity"
1874*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1875*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.description"
1876*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1877*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.response"
1878*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1879*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.impact"
1880*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1881*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.action"
1882*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1883*7c478bd9Sstevel@tonic-gate#
1884*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-NS
1885*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
1886*7c478bd9Sstevel@tonic-gate#
1887*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.type"
1888*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1889*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.severity"
1890*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1891*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.description"
1892*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1893*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.response"
1894*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1895*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.impact"
1896*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1897*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.action"
1898*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1899*7c478bd9Sstevel@tonic-gate#
1900*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-PA
1901*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1902*7c478bd9Sstevel@tonic-gate#
1903*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.type"
1904*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1905*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.severity"
1906*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1907*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.description"
1908*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1909*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.response"
1910*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1911*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.impact"
1912*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1913*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.action"
1914*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1915*7c478bd9Sstevel@tonic-gate#
1916*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-QP
1917*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
1918*7c478bd9Sstevel@tonic-gate#
1919*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.type"
1920*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1921*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.severity"
1922*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1923*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.description"
1924*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1925*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.response"
1926*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1927*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.impact"
1928*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1929*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.action"
1930*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1931*7c478bd9Sstevel@tonic-gate#
1932*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-RX
1933*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1934*7c478bd9Sstevel@tonic-gate#
1935*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.type"
1936*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1937*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.severity"
1938*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1939*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.description"
1940*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1941*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.response"
1942*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1943*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.impact"
1944*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1945*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.action"
1946*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1947*7c478bd9Sstevel@tonic-gate#
1948*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-S2
1949*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
1950*7c478bd9Sstevel@tonic-gate#
1951*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.type"
1952*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1953*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.severity"
1954*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1955*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.description"
1956*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1957*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.response"
1958*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1959*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.impact"
1960*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1961*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.action"
1962*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1963*7c478bd9Sstevel@tonic-gate#
1964*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-TJ
1965*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1966*7c478bd9Sstevel@tonic-gate#
1967*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.type"
1968*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1969*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.severity"
1970*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1971*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.description"
1972*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1973*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.response"
1974*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1975*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.impact"
1976*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1977*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.action"
1978*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1979*7c478bd9Sstevel@tonic-gate#
1980*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-UE
1981*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
1982*7c478bd9Sstevel@tonic-gate#
1983*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.type"
1984*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
1985*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.severity"
1986*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
1987*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.description"
1988*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
1989*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.response"
1990*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
1991*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.impact"
1992*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1993*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.action"
1994*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
1995*7c478bd9Sstevel@tonic-gate#
1996*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-VQ
1997*7c478bd9Sstevel@tonic-gate# keys: fault.io.schizo fault.io.xmits
1998*7c478bd9Sstevel@tonic-gate#
1999*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.type"
2000*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2001*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.severity"
2002*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2003*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.description"
2004*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2005*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.response"
2006*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2007*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.impact"
2008*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2009*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.action"
2010*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2011*7c478bd9Sstevel@tonic-gate#
2012*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-WC
2013*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
2014*7c478bd9Sstevel@tonic-gate#
2015*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.type"
2016*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2017*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.severity"
2018*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2019*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.description"
2020*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2021*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.response"
2022*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2023*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.impact"
2024*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2025*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.action"
2026*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2027*7c478bd9Sstevel@tonic-gate#
2028*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-XR
2029*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
2030*7c478bd9Sstevel@tonic-gate#
2031*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.type"
2032*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2033*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.severity"
2034*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2035*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.description"
2036*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2037*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.response"
2038*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2039*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.impact"
2040*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2041*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.action"
2042*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2043*7c478bd9Sstevel@tonic-gate#
2044*7c478bd9Sstevel@tonic-gate# code: SUN4U-8003-Y4
2045*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
2046*7c478bd9Sstevel@tonic-gate#
2047*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.type"
2048*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2049*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.severity"
2050*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2051*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.description"
2052*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2053*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.response"
2054*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2055*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.impact"
2056*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2057*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.action"
2058*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2059*7c478bd9Sstevel@tonic-gate#
2060*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-0A
2061*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo fault.io.xmits
2062*7c478bd9Sstevel@tonic-gate#
2063*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.type"
2064*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2065*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.severity"
2066*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2067*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.description"
2068*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2069*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.response"
2070*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2071*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.impact"
2072*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2073*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.action"
2074*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2075*7c478bd9Sstevel@tonic-gate#
2076*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-1P
2077*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
2078*7c478bd9Sstevel@tonic-gate#
2079*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.type"
2080*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2081*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.severity"
2082*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2083*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.description"
2084*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2085*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.response"
2086*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2087*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.impact"
2088*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2089*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.action"
2090*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2091*7c478bd9Sstevel@tonic-gate#
2092*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-25
2093*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2094*7c478bd9Sstevel@tonic-gate#
2095*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.type"
2096*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2097*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.severity"
2098*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2099*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.description"
2100*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2101*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.response"
2102*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2103*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.impact"
2104*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2105*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.action"
2106*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2107*7c478bd9Sstevel@tonic-gate#
2108*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-3S
2109*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2110*7c478bd9Sstevel@tonic-gate#
2111*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.type"
2112*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2113*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.severity"
2114*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2115*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.description"
2116*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2117*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.response"
2118*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2119*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.impact"
2120*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2121*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.action"
2122*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2123*7c478bd9Sstevel@tonic-gate#
2124*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-43
2125*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo fault.io.xmits
2126*7c478bd9Sstevel@tonic-gate#
2127*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.type"
2128*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2129*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.severity"
2130*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2131*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.description"
2132*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2133*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.response"
2134*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2135*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.impact"
2136*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2137*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.action"
2138*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2139*7c478bd9Sstevel@tonic-gate#
2140*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-5Y
2141*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
2142*7c478bd9Sstevel@tonic-gate#
2143*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.type"
2144*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2145*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.severity"
2146*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2147*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.description"
2148*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2149*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.response"
2150*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2151*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.impact"
2152*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2153*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.action"
2154*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2155*7c478bd9Sstevel@tonic-gate#
2156*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-6D
2157*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2158*7c478bd9Sstevel@tonic-gate#
2159*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.type"
2160*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2161*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.severity"
2162*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2163*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.description"
2164*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2165*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.response"
2166*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2167*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.impact"
2168*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2169*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.action"
2170*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2171*7c478bd9Sstevel@tonic-gate#
2172*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-7H
2173*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
2174*7c478bd9Sstevel@tonic-gate#
2175*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.type"
2176*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2177*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.severity"
2178*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2179*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.description"
2180*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2181*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.response"
2182*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2183*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.impact"
2184*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2185*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.action"
2186*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2187*7c478bd9Sstevel@tonic-gate#
2188*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-8R
2189*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2190*7c478bd9Sstevel@tonic-gate#
2191*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.type"
2192*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2193*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.severity"
2194*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2195*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.description"
2196*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2197*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.response"
2198*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2199*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.impact"
2200*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2201*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.action"
2202*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2203*7c478bd9Sstevel@tonic-gate#
2204*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-94
2205*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
2206*7c478bd9Sstevel@tonic-gate#
2207*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.type"
2208*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2209*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.severity"
2210*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2211*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.description"
2212*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2213*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.response"
2214*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2215*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.impact"
2216*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2217*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.action"
2218*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2219*7c478bd9Sstevel@tonic-gate#
2220*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-AQ
2221*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2222*7c478bd9Sstevel@tonic-gate#
2223*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.type"
2224*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2225*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.severity"
2226*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2227*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.description"
2228*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2229*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.response"
2230*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2231*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.impact"
2232*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2233*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.action"
2234*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2235*7c478bd9Sstevel@tonic-gate#
2236*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-CC
2237*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2238*7c478bd9Sstevel@tonic-gate#
2239*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.type"
2240*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2241*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.severity"
2242*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2243*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.description"
2244*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2245*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.response"
2246*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2247*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.impact"
2248*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2249*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.action"
2250*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2251*7c478bd9Sstevel@tonic-gate#
2252*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-DJ
2253*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo fault.io.xmits
2254*7c478bd9Sstevel@tonic-gate#
2255*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.type"
2256*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2257*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.severity"
2258*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2259*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.description"
2260*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2261*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.response"
2262*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2263*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.impact"
2264*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2265*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.action"
2266*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2267*7c478bd9Sstevel@tonic-gate#
2268*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-EE
2269*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
2270*7c478bd9Sstevel@tonic-gate#
2271*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.type"
2272*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2273*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.severity"
2274*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2275*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.description"
2276*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2277*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.response"
2278*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2279*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.impact"
2280*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2281*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.action"
2282*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2283*7c478bd9Sstevel@tonic-gate#
2284*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-FX
2285*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2286*7c478bd9Sstevel@tonic-gate#
2287*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.type"
2288*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2289*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.severity"
2290*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2291*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.description"
2292*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2293*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.response"
2294*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2295*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.impact"
2296*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2297*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.action"
2298*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2299*7c478bd9Sstevel@tonic-gate#
2300*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-G2
2301*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2302*7c478bd9Sstevel@tonic-gate#
2303*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.type"
2304*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2305*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.severity"
2306*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2307*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.description"
2308*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2309*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.response"
2310*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2311*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.impact"
2312*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2313*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.action"
2314*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2315*7c478bd9Sstevel@tonic-gate#
2316*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-HS
2317*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2318*7c478bd9Sstevel@tonic-gate#
2319*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.type"
2320*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2321*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.severity"
2322*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2323*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.description"
2324*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2325*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.response"
2326*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2327*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.impact"
2328*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2329*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.action"
2330*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2331*7c478bd9Sstevel@tonic-gate#
2332*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-J5
2333*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2334*7c478bd9Sstevel@tonic-gate#
2335*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.type"
2336*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2337*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.severity"
2338*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2339*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.description"
2340*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2341*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.response"
2342*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2343*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.impact"
2344*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2345*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.action"
2346*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2347*7c478bd9Sstevel@tonic-gate#
2348*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-KP
2349*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2350*7c478bd9Sstevel@tonic-gate#
2351*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.type"
2352*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2353*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.severity"
2354*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2355*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.description"
2356*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2357*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.response"
2358*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2359*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.impact"
2360*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2361*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.action"
2362*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2363*7c478bd9Sstevel@tonic-gate#
2364*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-LA
2365*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2366*7c478bd9Sstevel@tonic-gate#
2367*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.type"
2368*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2369*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.severity"
2370*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2371*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.description"
2372*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2373*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.response"
2374*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2375*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.impact"
2376*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2377*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.action"
2378*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2379*7c478bd9Sstevel@tonic-gate#
2380*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-MH
2381*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2382*7c478bd9Sstevel@tonic-gate#
2383*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.type"
2384*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2385*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.severity"
2386*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2387*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.description"
2388*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2389*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.response"
2390*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2391*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.impact"
2392*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2393*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.action"
2394*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2395*7c478bd9Sstevel@tonic-gate#
2396*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-ND
2397*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
2398*7c478bd9Sstevel@tonic-gate#
2399*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.type"
2400*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2401*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.severity"
2402*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2403*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.description"
2404*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2405*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.response"
2406*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2407*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.impact"
2408*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2409*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.action"
2410*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2411*7c478bd9Sstevel@tonic-gate#
2412*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-PY
2413*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2414*7c478bd9Sstevel@tonic-gate#
2415*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.type"
2416*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2417*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.severity"
2418*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2419*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.description"
2420*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2421*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.response"
2422*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2423*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.impact"
2424*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2425*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.action"
2426*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2427*7c478bd9Sstevel@tonic-gate#
2428*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-Q3
2429*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
2430*7c478bd9Sstevel@tonic-gate#
2431*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.type"
2432*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2433*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.severity"
2434*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2435*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.description"
2436*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2437*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.response"
2438*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2439*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.impact"
2440*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2441*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.action"
2442*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2443*7c478bd9Sstevel@tonic-gate#
2444*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-RC
2445*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2446*7c478bd9Sstevel@tonic-gate#
2447*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.type"
2448*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2449*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.severity"
2450*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2451*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.description"
2452*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2453*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.response"
2454*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2455*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.impact"
2456*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2457*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.action"
2458*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2459*7c478bd9Sstevel@tonic-gate#
2460*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-SQ
2461*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
2462*7c478bd9Sstevel@tonic-gate#
2463*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.type"
2464*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2465*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.severity"
2466*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2467*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.description"
2468*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2469*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.response"
2470*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2471*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.impact"
2472*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2473*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.action"
2474*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2475*7c478bd9Sstevel@tonic-gate#
2476*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-T4
2477*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2478*7c478bd9Sstevel@tonic-gate#
2479*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.type"
2480*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2481*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.severity"
2482*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2483*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.description"
2484*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2485*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.response"
2486*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2487*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.impact"
2488*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2489*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.action"
2490*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2491*7c478bd9Sstevel@tonic-gate#
2492*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-UR
2493*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
2494*7c478bd9Sstevel@tonic-gate#
2495*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.type"
2496*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2497*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.severity"
2498*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2499*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.description"
2500*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2501*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.response"
2502*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2503*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.impact"
2504*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2505*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.action"
2506*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2507*7c478bd9Sstevel@tonic-gate#
2508*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-V2
2509*7c478bd9Sstevel@tonic-gate# keys: fault.io.psycho
2510*7c478bd9Sstevel@tonic-gate#
2511*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.type"
2512*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2513*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.severity"
2514*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2515*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.description"
2516*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2517*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.response"
2518*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2519*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.impact"
2520*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2521*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.action"
2522*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2523*7c478bd9Sstevel@tonic-gate#
2524*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-WX
2525*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.psycho
2526*7c478bd9Sstevel@tonic-gate#
2527*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.type"
2528*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2529*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.severity"
2530*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2531*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.description"
2532*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2533*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.response"
2534*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2535*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.impact"
2536*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2537*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.action"
2538*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2539*7c478bd9Sstevel@tonic-gate#
2540*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-XE
2541*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.psycho
2542*7c478bd9Sstevel@tonic-gate#
2543*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.type"
2544*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2545*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.severity"
2546*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2547*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.description"
2548*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2549*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.response"
2550*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2551*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.impact"
2552*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2553*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.action"
2554*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2555*7c478bd9Sstevel@tonic-gate#
2556*7c478bd9Sstevel@tonic-gate# code: SUN4U-8004-YJ
2557*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
2558*7c478bd9Sstevel@tonic-gate#
2559*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.type"
2560*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2561*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.severity"
2562*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2563*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.description"
2564*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2565*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.response"
2566*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2567*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.impact"
2568*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2569*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.action"
2570*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2571*7c478bd9Sstevel@tonic-gate#
2572*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-0E
2573*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.psycho
2574*7c478bd9Sstevel@tonic-gate#
2575*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.type"
2576*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2577*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.severity"
2578*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2579*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.description"
2580*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2581*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.response"
2582*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2583*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.impact"
2584*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2585*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.action"
2586*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2587*7c478bd9Sstevel@tonic-gate#
2588*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-1J
2589*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
2590*7c478bd9Sstevel@tonic-gate#
2591*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.type"
2592*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2593*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.severity"
2594*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2595*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.description"
2596*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2597*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.response"
2598*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2599*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.impact"
2600*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2601*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.action"
2602*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2603*7c478bd9Sstevel@tonic-gate#
2604*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-22
2605*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.psycho
2606*7c478bd9Sstevel@tonic-gate#
2607*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.type"
2608*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2609*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.severity"
2610*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2611*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.description"
2612*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2613*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.response"
2614*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2615*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.impact"
2616*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2617*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.action"
2618*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2619*7c478bd9Sstevel@tonic-gate#
2620*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-3X
2621*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
2622*7c478bd9Sstevel@tonic-gate#
2623*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.type"
2624*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2625*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.severity"
2626*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2627*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.description"
2628*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2629*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.response"
2630*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2631*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.impact"
2632*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2633*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.action"
2634*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2635*7c478bd9Sstevel@tonic-gate#
2636*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-44
2637*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.psycho
2638*7c478bd9Sstevel@tonic-gate#
2639*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.type"
2640*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2641*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.severity"
2642*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2643*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.description"
2644*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2645*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.response"
2646*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2647*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.impact"
2648*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2649*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.action"
2650*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2651*7c478bd9Sstevel@tonic-gate#
2652*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-5R
2653*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
2654*7c478bd9Sstevel@tonic-gate#
2655*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.type"
2656*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2657*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.severity"
2658*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2659*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.description"
2660*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2661*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.response"
2662*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2663*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.impact"
2664*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2665*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.action"
2666*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2667*7c478bd9Sstevel@tonic-gate#
2668*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-6C
2669*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
2670*7c478bd9Sstevel@tonic-gate#
2671*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.type"
2672*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2673*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.severity"
2674*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2675*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.description"
2676*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2677*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.response"
2678*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2679*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.impact"
2680*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2681*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.action"
2682*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2683*7c478bd9Sstevel@tonic-gate#
2684*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-7Q
2685*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
2686*7c478bd9Sstevel@tonic-gate#
2687*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.type"
2688*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2689*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.severity"
2690*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2691*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.description"
2692*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2693*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.response"
2694*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2695*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.impact"
2696*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2697*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.action"
2698*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2699*7c478bd9Sstevel@tonic-gate#
2700*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-8Y
2701*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
2702*7c478bd9Sstevel@tonic-gate#
2703*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.type"
2704*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2705*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.severity"
2706*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2707*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.description"
2708*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2709*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.response"
2710*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2711*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.impact"
2712*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2713*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.action"
2714*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2715*7c478bd9Sstevel@tonic-gate#
2716*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-93
2717*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
2718*7c478bd9Sstevel@tonic-gate#
2719*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.type"
2720*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2721*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.severity"
2722*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2723*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.description"
2724*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2725*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.response"
2726*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2727*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.impact"
2728*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2729*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.action"
2730*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2731*7c478bd9Sstevel@tonic-gate#
2732*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-AH
2733*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2734*7c478bd9Sstevel@tonic-gate#
2735*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.type"
2736*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2737*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.severity"
2738*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2739*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.description"
2740*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2741*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.response"
2742*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2743*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.impact"
2744*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2745*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.action"
2746*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2747*7c478bd9Sstevel@tonic-gate#
2748*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-CD
2749*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
2750*7c478bd9Sstevel@tonic-gate#
2751*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.type"
2752*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2753*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.severity"
2754*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2755*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.description"
2756*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2757*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.response"
2758*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2759*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.impact"
2760*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2761*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.action"
2762*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2763*7c478bd9Sstevel@tonic-gate#
2764*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-DP
2765*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.psycho
2766*7c478bd9Sstevel@tonic-gate#
2767*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.type"
2768*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2769*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.severity"
2770*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2771*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.description"
2772*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2773*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.response"
2774*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2775*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.impact"
2776*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2777*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.action"
2778*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2779*7c478bd9Sstevel@tonic-gate#
2780*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-EA
2781*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
2782*7c478bd9Sstevel@tonic-gate#
2783*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.type"
2784*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2785*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.severity"
2786*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2787*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.description"
2788*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2789*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.response"
2790*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2791*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.impact"
2792*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2793*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.action"
2794*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2795*7c478bd9Sstevel@tonic-gate#
2796*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-FS
2797*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.psycho
2798*7c478bd9Sstevel@tonic-gate#
2799*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.type"
2800*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2801*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.severity"
2802*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2803*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.description"
2804*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2805*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.response"
2806*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2807*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.impact"
2808*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2809*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.action"
2810*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2811*7c478bd9Sstevel@tonic-gate#
2812*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-G5
2813*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
2814*7c478bd9Sstevel@tonic-gate#
2815*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.type"
2816*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2817*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.severity"
2818*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2819*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.description"
2820*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2821*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.response"
2822*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2823*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.impact"
2824*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2825*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.action"
2826*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2827*7c478bd9Sstevel@tonic-gate#
2828*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-HX
2829*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.psycho
2830*7c478bd9Sstevel@tonic-gate#
2831*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.type"
2832*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2833*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.severity"
2834*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2835*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.description"
2836*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2837*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.response"
2838*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2839*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.impact"
2840*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2841*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.action"
2842*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2843*7c478bd9Sstevel@tonic-gate#
2844*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-J2
2845*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
2846*7c478bd9Sstevel@tonic-gate#
2847*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.type"
2848*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2849*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.severity"
2850*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2851*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.description"
2852*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2853*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.response"
2854*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2855*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.impact"
2856*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2857*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.action"
2858*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2859*7c478bd9Sstevel@tonic-gate#
2860*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-KJ
2861*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2862*7c478bd9Sstevel@tonic-gate#
2863*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.type"
2864*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2865*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.severity"
2866*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2867*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.description"
2868*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2869*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.response"
2870*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2871*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.impact"
2872*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2873*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.action"
2874*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2875*7c478bd9Sstevel@tonic-gate#
2876*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-LE
2877*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
2878*7c478bd9Sstevel@tonic-gate#
2879*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.type"
2880*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2881*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.severity"
2882*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2883*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.description"
2884*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2885*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.response"
2886*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2887*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.impact"
2888*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2889*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.action"
2890*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2891*7c478bd9Sstevel@tonic-gate#
2892*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-MQ
2893*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
2894*7c478bd9Sstevel@tonic-gate#
2895*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.type"
2896*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2897*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.severity"
2898*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2899*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.description"
2900*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2901*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.response"
2902*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2903*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.impact"
2904*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2905*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.action"
2906*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2907*7c478bd9Sstevel@tonic-gate#
2908*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-NC
2909*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
2910*7c478bd9Sstevel@tonic-gate#
2911*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.type"
2912*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2913*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.severity"
2914*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2915*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.description"
2916*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2917*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.response"
2918*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2919*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.impact"
2920*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2921*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.action"
2922*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2923*7c478bd9Sstevel@tonic-gate#
2924*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-PR
2925*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2926*7c478bd9Sstevel@tonic-gate#
2927*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.type"
2928*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2929*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.severity"
2930*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2931*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.description"
2932*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2933*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.response"
2934*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2935*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.impact"
2936*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2937*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.action"
2938*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2939*7c478bd9Sstevel@tonic-gate#
2940*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-Q4
2941*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
2942*7c478bd9Sstevel@tonic-gate#
2943*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.type"
2944*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2945*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.severity"
2946*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2947*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.description"
2948*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2949*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.response"
2950*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2951*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.impact"
2952*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2953*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.action"
2954*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2955*7c478bd9Sstevel@tonic-gate#
2956*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-RD
2957*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2958*7c478bd9Sstevel@tonic-gate#
2959*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.type"
2960*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2961*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.severity"
2962*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2963*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.description"
2964*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2965*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.response"
2966*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2967*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.impact"
2968*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2969*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.action"
2970*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2971*7c478bd9Sstevel@tonic-gate#
2972*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-SH
2973*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2974*7c478bd9Sstevel@tonic-gate#
2975*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.type"
2976*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2977*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.severity"
2978*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2979*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.description"
2980*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2981*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.response"
2982*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2983*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.impact"
2984*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
2985*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.action"
2986*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
2987*7c478bd9Sstevel@tonic-gate#
2988*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-T3
2989*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
2990*7c478bd9Sstevel@tonic-gate#
2991*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.type"
2992*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
2993*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.severity"
2994*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
2995*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.description"
2996*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
2997*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.response"
2998*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
2999*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.impact"
3000*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3001*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.action"
3002*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3003*7c478bd9Sstevel@tonic-gate#
3004*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-UY
3005*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
3006*7c478bd9Sstevel@tonic-gate#
3007*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.type"
3008*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3009*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.severity"
3010*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3011*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.description"
3012*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3013*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.response"
3014*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3015*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.impact"
3016*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3017*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.action"
3018*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3019*7c478bd9Sstevel@tonic-gate#
3020*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-V5
3021*7c478bd9Sstevel@tonic-gate# keys: fault.io.tomatillo
3022*7c478bd9Sstevel@tonic-gate#
3023*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.type"
3024*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3025*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.severity"
3026*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3027*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.description"
3028*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3029*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.response"
3030*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3031*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.impact"
3032*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3033*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.action"
3034*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3035*7c478bd9Sstevel@tonic-gate#
3036*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-WS
3037*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.tomatillo
3038*7c478bd9Sstevel@tonic-gate#
3039*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.type"
3040*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3041*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.severity"
3042*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3043*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.description"
3044*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3045*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.response"
3046*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3047*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.impact"
3048*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3049*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.action"
3050*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3051*7c478bd9Sstevel@tonic-gate#
3052*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-XA
3053*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.tomatillo
3054*7c478bd9Sstevel@tonic-gate#
3055*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.type"
3056*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3057*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.severity"
3058*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3059*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.description"
3060*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3061*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.response"
3062*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3063*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.impact"
3064*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3065*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.action"
3066*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3067*7c478bd9Sstevel@tonic-gate#
3068*7c478bd9Sstevel@tonic-gate# code: SUN4U-8005-YP
3069*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
3070*7c478bd9Sstevel@tonic-gate#
3071*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.type"
3072*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3073*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.severity"
3074*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3075*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.description"
3076*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3077*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.response"
3078*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3079*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.impact"
3080*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3081*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.action"
3082*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3083*7c478bd9Sstevel@tonic-gate#
3084*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-04
3085*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.tomatillo
3086*7c478bd9Sstevel@tonic-gate#
3087*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.type"
3088*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3089*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.severity"
3090*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3091*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.description"
3092*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3093*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.response"
3094*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3095*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.impact"
3096*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3097*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.action"
3098*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3099*7c478bd9Sstevel@tonic-gate#
3100*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-1R
3101*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
3102*7c478bd9Sstevel@tonic-gate#
3103*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.type"
3104*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3105*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.severity"
3106*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3107*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.description"
3108*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3109*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.response"
3110*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3111*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.impact"
3112*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3113*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.action"
3114*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3115*7c478bd9Sstevel@tonic-gate#
3116*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-2C
3117*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
3118*7c478bd9Sstevel@tonic-gate#
3119*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.type"
3120*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3121*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.severity"
3122*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3123*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.description"
3124*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3125*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.response"
3126*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3127*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.impact"
3128*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3129*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.action"
3130*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3131*7c478bd9Sstevel@tonic-gate#
3132*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-3Q
3133*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
3134*7c478bd9Sstevel@tonic-gate#
3135*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.type"
3136*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3137*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.severity"
3138*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3139*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.description"
3140*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3141*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.response"
3142*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3143*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.impact"
3144*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3145*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.action"
3146*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3147*7c478bd9Sstevel@tonic-gate#
3148*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-4E
3149*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.tomatillo
3150*7c478bd9Sstevel@tonic-gate#
3151*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.type"
3152*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3153*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.severity"
3154*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3155*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.description"
3156*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3157*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.response"
3158*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3159*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.impact"
3160*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3161*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.action"
3162*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3163*7c478bd9Sstevel@tonic-gate#
3164*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-5J
3165*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
3166*7c478bd9Sstevel@tonic-gate#
3167*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.type"
3168*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3169*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.severity"
3170*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3171*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.description"
3172*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3173*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.response"
3174*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3175*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.impact"
3176*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3177*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.action"
3178*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3179*7c478bd9Sstevel@tonic-gate#
3180*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-62
3181*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3182*7c478bd9Sstevel@tonic-gate#
3183*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.type"
3184*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3185*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.severity"
3186*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3187*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.description"
3188*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3189*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.response"
3190*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3191*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.impact"
3192*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3193*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.action"
3194*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3195*7c478bd9Sstevel@tonic-gate#
3196*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-7X
3197*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
3198*7c478bd9Sstevel@tonic-gate#
3199*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.type"
3200*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3201*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.severity"
3202*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3203*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.description"
3204*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3205*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.response"
3206*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3207*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.impact"
3208*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3209*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.action"
3210*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3211*7c478bd9Sstevel@tonic-gate#
3212*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-8P
3213*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3214*7c478bd9Sstevel@tonic-gate#
3215*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.type"
3216*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3217*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.severity"
3218*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3219*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.description"
3220*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3221*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.response"
3222*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3223*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.impact"
3224*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3225*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.action"
3226*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3227*7c478bd9Sstevel@tonic-gate#
3228*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-9A
3229*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3230*7c478bd9Sstevel@tonic-gate#
3231*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.type"
3232*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3233*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.severity"
3234*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3235*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.description"
3236*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3237*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.response"
3238*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3239*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.impact"
3240*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3241*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.action"
3242*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3243*7c478bd9Sstevel@tonic-gate#
3244*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-AS
3245*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3246*7c478bd9Sstevel@tonic-gate#
3247*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.type"
3248*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3249*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.severity"
3250*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3251*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.description"
3252*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3253*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.response"
3254*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3255*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.impact"
3256*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3257*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.action"
3258*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3259*7c478bd9Sstevel@tonic-gate#
3260*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-C5
3261*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
3262*7c478bd9Sstevel@tonic-gate#
3263*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.type"
3264*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3265*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.severity"
3266*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3267*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.description"
3268*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3269*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.response"
3270*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3271*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.impact"
3272*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3273*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.action"
3274*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3275*7c478bd9Sstevel@tonic-gate#
3276*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-DY
3277*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.tomatillo
3278*7c478bd9Sstevel@tonic-gate#
3279*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.type"
3280*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3281*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.severity"
3282*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3283*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.description"
3284*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3285*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.response"
3286*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3287*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.impact"
3288*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3289*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.action"
3290*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3291*7c478bd9Sstevel@tonic-gate#
3292*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-E3
3293*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
3294*7c478bd9Sstevel@tonic-gate#
3295*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.type"
3296*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3297*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.severity"
3298*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3299*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.description"
3300*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3301*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.response"
3302*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3303*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.impact"
3304*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3305*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.action"
3306*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3307*7c478bd9Sstevel@tonic-gate#
3308*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-FH
3309*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
3310*7c478bd9Sstevel@tonic-gate#
3311*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.type"
3312*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3313*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.severity"
3314*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3315*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.description"
3316*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3317*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.response"
3318*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3319*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.impact"
3320*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3321*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.action"
3322*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3323*7c478bd9Sstevel@tonic-gate#
3324*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-GD
3325*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
3326*7c478bd9Sstevel@tonic-gate#
3327*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.type"
3328*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3329*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.severity"
3330*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3331*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.description"
3332*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3333*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.response"
3334*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3335*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.impact"
3336*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3337*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.action"
3338*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3339*7c478bd9Sstevel@tonic-gate#
3340*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-HQ
3341*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
3342*7c478bd9Sstevel@tonic-gate#
3343*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.type"
3344*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3345*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.severity"
3346*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3347*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.description"
3348*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3349*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.response"
3350*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3351*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.impact"
3352*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3353*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.action"
3354*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3355*7c478bd9Sstevel@tonic-gate#
3356*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-JC
3357*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
3358*7c478bd9Sstevel@tonic-gate#
3359*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.type"
3360*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3361*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.severity"
3362*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3363*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.description"
3364*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3365*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.response"
3366*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3367*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.impact"
3368*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3369*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.action"
3370*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3371*7c478bd9Sstevel@tonic-gate#
3372*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-KR
3373*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3374*7c478bd9Sstevel@tonic-gate#
3375*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.type"
3376*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3377*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.severity"
3378*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3379*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.description"
3380*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3381*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.response"
3382*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3383*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.impact"
3384*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3385*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.action"
3386*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3387*7c478bd9Sstevel@tonic-gate#
3388*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-L4
3389*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
3390*7c478bd9Sstevel@tonic-gate#
3391*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.type"
3392*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3393*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.severity"
3394*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3395*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.description"
3396*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3397*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.response"
3398*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3399*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.impact"
3400*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3401*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.action"
3402*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3403*7c478bd9Sstevel@tonic-gate#
3404*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-MX
3405*7c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3406*7c478bd9Sstevel@tonic-gate#
3407*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.type"
3408*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3409*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.severity"
3410*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3411*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.description"
3412*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3413*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.response"
3414*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3415*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.impact"
3416*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3417*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.action"
3418*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3419*7c478bd9Sstevel@tonic-gate#
3420*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-N2
3421*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3422*7c478bd9Sstevel@tonic-gate#
3423*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.type"
3424*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3425*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.severity"
3426*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3427*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.description"
3428*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3429*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.response"
3430*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3431*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.impact"
3432*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3433*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.action"
3434*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3435*7c478bd9Sstevel@tonic-gate#
3436*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-PJ
3437*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3438*7c478bd9Sstevel@tonic-gate#
3439*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.type"
3440*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3441*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.severity"
3442*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3443*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.description"
3444*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3445*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.response"
3446*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3447*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.impact"
3448*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3449*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.action"
3450*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3451*7c478bd9Sstevel@tonic-gate#
3452*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-QE
3453*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3454*7c478bd9Sstevel@tonic-gate#
3455*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.type"
3456*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3457*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.severity"
3458*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3459*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.description"
3460*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3461*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.response"
3462*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3463*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.impact"
3464*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3465*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.action"
3466*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3467*7c478bd9Sstevel@tonic-gate#
3468*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-R5
3469*7c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3470*7c478bd9Sstevel@tonic-gate#
3471*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.type"
3472*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3473*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.severity"
3474*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3475*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.description"
3476*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3477*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.response"
3478*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3479*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.impact"
3480*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3481*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.action"
3482*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3483*7c478bd9Sstevel@tonic-gate#
3484*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-SS
3485*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3486*7c478bd9Sstevel@tonic-gate#
3487*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.type"
3488*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3489*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.severity"
3490*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3491*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.description"
3492*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3493*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.response"
3494*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3495*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.impact"
3496*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3497*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.action"
3498*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3499*7c478bd9Sstevel@tonic-gate#
3500*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-TA
3501*7c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3502*7c478bd9Sstevel@tonic-gate#
3503*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.type"
3504*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3505*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.severity"
3506*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3507*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.description"
3508*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3509*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.response"
3510*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3511*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.impact"
3512*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3513*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.action"
3514*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3515*7c478bd9Sstevel@tonic-gate#
3516*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-UP
3517*7c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
3518*7c478bd9Sstevel@tonic-gate#
3519*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.type"
3520*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3521*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.severity"
3522*7c478bd9Sstevel@tonic-gatemsgstr "Critical"
3523*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.description"
3524*7c478bd9Sstevel@tonic-gatemsgstr "A problem has been detected in the PCI subsystem.  Refer to %s for more information."
3525*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.response"
3526*7c478bd9Sstevel@tonic-gatemsgstr "One or more device instances may be disabled"
3527*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.impact"
3528*7c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
3529*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.action"
3530*7c478bd9Sstevel@tonic-gatemsgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
3531*7c478bd9Sstevel@tonic-gate#
3532*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-VD
3533*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.dcache
3534*7c478bd9Sstevel@tonic-gate#
3535*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.type"
3536*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3537*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.severity"
3538*7c478bd9Sstevel@tonic-gatemsgstr "Major"
3539*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.description"
3540*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3541*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.response"
3542*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
3543*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.impact"
3544*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
3545*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.action"
3546*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3547*7c478bd9Sstevel@tonic-gate#
3548*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-WH
3549*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.icache
3550*7c478bd9Sstevel@tonic-gate#
3551*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.type"
3552*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3553*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.severity"
3554*7c478bd9Sstevel@tonic-gatemsgstr "Major"
3555*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.description"
3556*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3557*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.response"
3558*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
3559*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.impact"
3560*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
3561*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.action"
3562*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3563*7c478bd9Sstevel@tonic-gate#
3564*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-X3
3565*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
3566*7c478bd9Sstevel@tonic-gate#
3567*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.type"
3568*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3569*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.severity"
3570*7c478bd9Sstevel@tonic-gatemsgstr "Major"
3571*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.description"
3572*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3573*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.response"
3574*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
3575*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.impact"
3576*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
3577*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.action"
3578*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3579*7c478bd9Sstevel@tonic-gate#
3580*7c478bd9Sstevel@tonic-gate# code: SUN4U-8006-YY
3581*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
3582*7c478bd9Sstevel@tonic-gate#
3583*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.type"
3584*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3585*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.severity"
3586*7c478bd9Sstevel@tonic-gatemsgstr "Major"
3587*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.description"
3588*7c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3589*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.response"
3590*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
3591*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.impact"
3592*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
3593*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.action"
3594*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3595*7c478bd9Sstevel@tonic-gate#
3596*7c478bd9Sstevel@tonic-gate# code: SUN4U-8007-03
3597*7c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.fpu
3598*7c478bd9Sstevel@tonic-gate#
3599*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.type"
3600*7c478bd9Sstevel@tonic-gatemsgstr "Fault"
3601*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.severity"
3602*7c478bd9Sstevel@tonic-gatemsgstr "Major"
3603*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.description"
3604*7c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3605*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.response"
3606*7c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
3607*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.impact"
3608*7c478bd9Sstevel@tonic-gatemsgstr "Performance of this system may be affected."
3609*7c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.action"
3610*7c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU.  Use fmdump -v -u <EVENT_ID> to identify the CPU."
3611