xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4.po (revision 261a51afbf7133d9f7c89f1388050677f56b7d1a)
10890ae4eSvn83148#
2*261a51afSet142600# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
30890ae4eSvn83148# Use is subject to license terms.
40890ae4eSvn83148#
50890ae4eSvn83148# CDDL HEADER START
60890ae4eSvn83148#
70890ae4eSvn83148# The contents of this file are subject to the terms of the
89dd0f810Scindi# Common Development and Distribution License (the "License").
99dd0f810Scindi# You may not use this file except in compliance with the License.
100890ae4eSvn83148#
110890ae4eSvn83148# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
120890ae4eSvn83148# or http://www.opensolaris.org/os/licensing.
130890ae4eSvn83148# See the License for the specific language governing permissions
140890ae4eSvn83148# and limitations under the License.
150890ae4eSvn83148#
160890ae4eSvn83148# When distributing Covered Code, include this CDDL HEADER in each
170890ae4eSvn83148# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
180890ae4eSvn83148# If applicable, add the following below this CDDL HEADER, with the
190890ae4eSvn83148# fields enclosed by brackets "[]" replaced with your own identifying
200890ae4eSvn83148# information: Portions Copyright [yyyy] [name of copyright owner]
210890ae4eSvn83148#
220890ae4eSvn83148# CDDL HEADER END
230890ae4eSvn83148#
240890ae4eSvn83148#ident	"%Z%%M%	%I%	%E% SMI"
250890ae4eSvn83148#
261645b324Svn83148# DO NOT EDIT -- this file is generated by the Event Registry.
271645b324Svn83148#
280890ae4eSvn83148#
290890ae4eSvn83148# code: SUN4-8000-0Y
300890ae4eSvn83148# keys: fault.io.fire.asic
310890ae4eSvn83148#
320890ae4eSvn83148msgid "SUN4-8000-0Y.type"
330890ae4eSvn83148msgstr "Fault"
340890ae4eSvn83148msgid "SUN4-8000-0Y.severity"
350890ae4eSvn83148msgstr "Critical"
360890ae4eSvn83148msgid "SUN4-8000-0Y.description"
37*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
380890ae4eSvn83148msgid "SUN4-8000-0Y.response"
391645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
400890ae4eSvn83148msgid "SUN4-8000-0Y.impact"
410890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
420890ae4eSvn83148msgid "SUN4-8000-0Y.action"
43*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
440890ae4eSvn83148#
450890ae4eSvn83148# code: SUN4-8000-13
460890ae4eSvn83148# keys: fault.io.ebus
470890ae4eSvn83148#
480890ae4eSvn83148msgid "SUN4-8000-13.type"
490890ae4eSvn83148msgstr "Fault"
500890ae4eSvn83148msgid "SUN4-8000-13.severity"
510890ae4eSvn83148msgstr "Critical"
520890ae4eSvn83148msgid "SUN4-8000-13.description"
531645b324Svn83148msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
540890ae4eSvn83148msgid "SUN4-8000-13.response"
551645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
560890ae4eSvn83148msgid "SUN4-8000-13.impact"
570890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
580890ae4eSvn83148msgid "SUN4-8000-13.action"
59*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
600890ae4eSvn83148#
610890ae4eSvn83148# code: SUN4-8000-2H
620890ae4eSvn83148# keys: fault.io.datapath
630890ae4eSvn83148#
640890ae4eSvn83148msgid "SUN4-8000-2H.type"
650890ae4eSvn83148msgstr "Fault"
660890ae4eSvn83148msgid "SUN4-8000-2H.severity"
670890ae4eSvn83148msgstr "Critical"
680890ae4eSvn83148msgid "SUN4-8000-2H.description"
6919017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
700890ae4eSvn83148msgid "SUN4-8000-2H.response"
7119017637Svn83148msgstr "None"
720890ae4eSvn83148msgid "SUN4-8000-2H.impact"
7319017637Svn83148msgstr "None"
740890ae4eSvn83148msgid "SUN4-8000-2H.action"
7519017637Svn83148msgstr "None"
760890ae4eSvn83148#
770890ae4eSvn83148# code: SUN4-8000-3D
780890ae4eSvn83148# keys: fault.io.hbus
790890ae4eSvn83148#
800890ae4eSvn83148msgid "SUN4-8000-3D.type"
810890ae4eSvn83148msgstr "Fault"
820890ae4eSvn83148msgid "SUN4-8000-3D.severity"
830890ae4eSvn83148msgstr "Critical"
840890ae4eSvn83148msgid "SUN4-8000-3D.description"
85*261a51afSet142600msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
860890ae4eSvn83148msgid "SUN4-8000-3D.response"
871645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
880890ae4eSvn83148msgid "SUN4-8000-3D.impact"
890890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
900890ae4eSvn83148msgid "SUN4-8000-3D.action"
91*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
920890ae4eSvn83148#
930890ae4eSvn83148# code: SUN4-8000-4P
940890ae4eSvn83148# keys: fault.io.fire.pciex.device
950890ae4eSvn83148#
960890ae4eSvn83148msgid "SUN4-8000-4P.type"
970890ae4eSvn83148msgstr "Fault"
980890ae4eSvn83148msgid "SUN4-8000-4P.severity"
990890ae4eSvn83148msgstr "Critical"
1000890ae4eSvn83148msgid "SUN4-8000-4P.description"
101*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
1020890ae4eSvn83148msgid "SUN4-8000-4P.response"
1031645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
1040890ae4eSvn83148msgid "SUN4-8000-4P.impact"
1050890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
1060890ae4eSvn83148msgid "SUN4-8000-4P.action"
107*261a51afSet142600msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
1080890ae4eSvn83148#
1090890ae4eSvn83148# code: SUN4-8000-5A
1100890ae4eSvn83148# keys: defect.io.fire.pciex.driver
1110890ae4eSvn83148#
1120890ae4eSvn83148msgid "SUN4-8000-5A.type"
1130890ae4eSvn83148msgstr "Defect"
1140890ae4eSvn83148msgid "SUN4-8000-5A.severity"
1150890ae4eSvn83148msgstr "Critical"
1160890ae4eSvn83148msgid "SUN4-8000-5A.description"
117*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
1180890ae4eSvn83148msgid "SUN4-8000-5A.response"
1191645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
1200890ae4eSvn83148msgid "SUN4-8000-5A.impact"
1210890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with\nthis problem"
1220890ae4eSvn83148msgid "SUN4-8000-5A.action"
1239dd0f810Scindimsgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
1240890ae4eSvn83148#
1250890ae4eSvn83148# code: SUN4-8000-6S
1260890ae4eSvn83148# keys: fault.io.datapath fault.io.fire.asic
1270890ae4eSvn83148#
1280890ae4eSvn83148msgid "SUN4-8000-6S.type"
1290890ae4eSvn83148msgstr "Fault"
1300890ae4eSvn83148msgid "SUN4-8000-6S.severity"
1310890ae4eSvn83148msgstr "Critical"
1320890ae4eSvn83148msgid "SUN4-8000-6S.description"
13319017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
1340890ae4eSvn83148msgid "SUN4-8000-6S.response"
13519017637Svn83148msgstr "None"
1360890ae4eSvn83148msgid "SUN4-8000-6S.impact"
13719017637Svn83148msgstr "None"
1380890ae4eSvn83148msgid "SUN4-8000-6S.action"
13919017637Svn83148msgstr "None"
1400890ae4eSvn83148#
1410890ae4eSvn83148# code: SUN4-8000-75
1420890ae4eSvn83148# keys: fault.io.fire.asic fault.io.fire.pciex.device
1430890ae4eSvn83148#
1440890ae4eSvn83148msgid "SUN4-8000-75.type"
1450890ae4eSvn83148msgstr "Fault"
1460890ae4eSvn83148msgid "SUN4-8000-75.severity"
1470890ae4eSvn83148msgstr "Critical"
1480890ae4eSvn83148msgid "SUN4-8000-75.description"
149*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
1500890ae4eSvn83148msgid "SUN4-8000-75.response"
1511645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
1520890ae4eSvn83148msgid "SUN4-8000-75.impact"
1530890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
1540890ae4eSvn83148msgid "SUN4-8000-75.action"
155*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
1560890ae4eSvn83148#
1570890ae4eSvn83148# code: SUN4-8000-8E
1580890ae4eSvn83148# keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
1590890ae4eSvn83148#
1600890ae4eSvn83148msgid "SUN4-8000-8E.type"
1610890ae4eSvn83148msgstr "Defect"
1620890ae4eSvn83148msgid "SUN4-8000-8E.severity"
1630890ae4eSvn83148msgstr "Critical"
1640890ae4eSvn83148msgid "SUN4-8000-8E.description"
165*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
1660890ae4eSvn83148msgid "SUN4-8000-8E.response"
1671645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
1680890ae4eSvn83148msgid "SUN4-8000-8E.impact"
1690890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this problem"
1700890ae4eSvn83148msgid "SUN4-8000-8E.action"
1719dd0f810Scindimsgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
1720890ae4eSvn83148#
1730890ae4eSvn83148# code: SUN4-8000-9J
1740890ae4eSvn83148# keys: fault.io.fire.pci.device fault.io.fire.pciex.device
1750890ae4eSvn83148#
1760890ae4eSvn83148msgid "SUN4-8000-9J.type"
1770890ae4eSvn83148msgstr "Fault"
1780890ae4eSvn83148msgid "SUN4-8000-9J.severity"
1790890ae4eSvn83148msgstr "Critical"
1800890ae4eSvn83148msgid "SUN4-8000-9J.description"
18119017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
1820890ae4eSvn83148msgid "SUN4-8000-9J.response"
18319017637Svn83148msgstr "None"
1840890ae4eSvn83148msgid "SUN4-8000-9J.impact"
18519017637Svn83148msgstr "None"
1860890ae4eSvn83148msgid "SUN4-8000-9J.action"
18719017637Svn83148msgstr "None"
1880890ae4eSvn83148#
1890890ae4eSvn83148# code: SUN4-8000-A2
1900890ae4eSvn83148# keys: fault.io.fire.pci.device
1910890ae4eSvn83148#
1920890ae4eSvn83148msgid "SUN4-8000-A2.type"
1930890ae4eSvn83148msgstr "Fault"
1940890ae4eSvn83148msgid "SUN4-8000-A2.severity"
1950890ae4eSvn83148msgstr "Critical"
1960890ae4eSvn83148msgid "SUN4-8000-A2.description"
197*261a51afSet142600msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
1980890ae4eSvn83148msgid "SUN4-8000-A2.response"
1991645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
2000890ae4eSvn83148msgid "SUN4-8000-A2.impact"
2010890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault"
2020890ae4eSvn83148msgid "SUN4-8000-A2.action"
203*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
2040890ae4eSvn83148#
2050890ae4eSvn83148# code: SUN4-8000-CX
2060890ae4eSvn83148# keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
2070890ae4eSvn83148#
2080890ae4eSvn83148msgid "SUN4-8000-CX.type"
2090890ae4eSvn83148msgstr "Fault"
2100890ae4eSvn83148msgid "SUN4-8000-CX.severity"
2110890ae4eSvn83148msgstr "Critical"
2120890ae4eSvn83148msgid "SUN4-8000-CX.description"
21319017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
2140890ae4eSvn83148msgid "SUN4-8000-CX.response"
21519017637Svn83148msgstr "None"
2160890ae4eSvn83148msgid "SUN4-8000-CX.impact"
21719017637Svn83148msgstr "None"
2180890ae4eSvn83148msgid "SUN4-8000-CX.action"
21919017637Svn83148msgstr "None"
22019017637Svn83148#
22119017637Svn83148# code: SUN4-8000-D4
22219017637Svn83148# keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
22319017637Svn83148#
22419017637Svn83148msgid "SUN4-8000-D4.type"
22519017637Svn83148msgstr "Fault"
22619017637Svn83148msgid "SUN4-8000-D4.severity"
22719017637Svn83148msgstr "Critical"
22819017637Svn83148msgid "SUN4-8000-D4.description"
22919017637Svn83148msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
23019017637Svn83148msgid "SUN4-8000-D4.response"
2311645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
23219017637Svn83148msgid "SUN4-8000-D4.impact"
23319017637Svn83148msgstr "Loss of services provided by the device instances associated with this fault"
23419017637Svn83148msgid "SUN4-8000-D4.action"
235*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
23619017637Svn83148#
23719017637Svn83148# code: SUN4-8000-ER
23819017637Svn83148# keys: fault.io.fire.asic fault.io.fire.pci.device
23919017637Svn83148#
24019017637Svn83148msgid "SUN4-8000-ER.type"
24119017637Svn83148msgstr "Fault"
24219017637Svn83148msgid "SUN4-8000-ER.severity"
24319017637Svn83148msgstr "Critical"
24419017637Svn83148msgid "SUN4-8000-ER.description"
24519017637Svn83148msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
24619017637Svn83148msgid "SUN4-8000-ER.response"
2471645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
24819017637Svn83148msgid "SUN4-8000-ER.impact"
24919017637Svn83148msgstr "Loss of services provided by the device instances associated with this fault"
25019017637Svn83148msgid "SUN4-8000-ER.action"
251*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
2521645b324Svn83148#
2531645b324Svn83148# code: SUN4-8000-FC
2541645b324Svn83148# keys: fault.io.fire.hbus
2551645b324Svn83148#
2561645b324Svn83148msgid "SUN4-8000-FC.type"
2571645b324Svn83148msgstr "Fault"
2581645b324Svn83148msgid "SUN4-8000-FC.severity"
2591645b324Svn83148msgstr "Major"
2601645b324Svn83148msgid "SUN4-8000-FC.description"
261*261a51afSet142600msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
2621645b324Svn83148msgid "SUN4-8000-FC.response"
2631645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
2641645b324Svn83148msgid "SUN4-8000-FC.impact"
2651645b324Svn83148msgstr "Loss of services provided by the device instances associated with this fault"
2661645b324Svn83148msgid "SUN4-8000-FC.action"
267*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
26814ea4bb7Ssd77468#
26914ea4bb7Ssd77468# code: SUN4-8000-GQ
27014ea4bb7Ssd77468# keys: fault.io.fire.datapath fault.io.fire.hbus
27114ea4bb7Ssd77468#
27214ea4bb7Ssd77468msgid "SUN4-8000-GQ.type"
27314ea4bb7Ssd77468msgstr "Fault"
27414ea4bb7Ssd77468msgid "SUN4-8000-GQ.severity"
27514ea4bb7Ssd77468msgstr "Critical"
27614ea4bb7Ssd77468msgid "SUN4-8000-GQ.description"
27714ea4bb7Ssd77468msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
27814ea4bb7Ssd77468msgid "SUN4-8000-GQ.response"
27914ea4bb7Ssd77468msgstr "One or more device instances may be disabled\n"
28014ea4bb7Ssd77468msgid "SUN4-8000-GQ.impact"
28114ea4bb7Ssd77468msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
28214ea4bb7Ssd77468msgid "SUN4-8000-GQ.action"
28314ea4bb7Ssd77468msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
284*261a51afSet142600#
285*261a51afSet142600# code: SUN4-8000-HD
286*261a51afSet142600# keys: fault.io.fire.hb.sw-config
287*261a51afSet142600#
288*261a51afSet142600msgid "SUN4-8000-HD.type"
289*261a51afSet142600msgstr "Fault"
290*261a51afSet142600msgid "SUN4-8000-HD.severity"
291*261a51afSet142600msgstr "Critical"
292*261a51afSet142600msgid "SUN4-8000-HD.description"
293*261a51afSet142600msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
294*261a51afSet142600msgid "SUN4-8000-HD.response"
295*261a51afSet142600msgstr "One or more device instances may be disabled\n"
296*261a51afSet142600msgid "SUN4-8000-HD.impact"
297*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
298*261a51afSet142600msgid "SUN4-8000-HD.action"
299*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
300*261a51afSet142600#
301*261a51afSet142600# code: SUN4-8000-JH
302*261a51afSet142600# keys: fault.io.fire.dmc.sw-algorithm
303*261a51afSet142600#
304*261a51afSet142600msgid "SUN4-8000-JH.type"
305*261a51afSet142600msgstr "Fault"
306*261a51afSet142600msgid "SUN4-8000-JH.severity"
307*261a51afSet142600msgstr "Critical"
308*261a51afSet142600msgid "SUN4-8000-JH.description"
309*261a51afSet142600msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
310*261a51afSet142600msgid "SUN4-8000-JH.response"
311*261a51afSet142600msgstr "One or more device instances may be disabled\n"
312*261a51afSet142600msgid "SUN4-8000-JH.impact"
313*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
314*261a51afSet142600msgid "SUN4-8000-JH.action"
315*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
316*261a51afSet142600#
317*261a51afSet142600# code: SUN4-8000-K3
318*261a51afSet142600# keys: fault.io.fire.dmc.sw-state
319*261a51afSet142600#
320*261a51afSet142600msgid "SUN4-8000-K3.type"
321*261a51afSet142600msgstr "Fault"
322*261a51afSet142600msgid "SUN4-8000-K3.severity"
323*261a51afSet142600msgstr "Critical"
324*261a51afSet142600msgid "SUN4-8000-K3.description"
325*261a51afSet142600msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
326*261a51afSet142600msgid "SUN4-8000-K3.response"
327*261a51afSet142600msgstr "One or more device instances may be disabled\n"
328*261a51afSet142600msgid "SUN4-8000-K3.impact"
329*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
330*261a51afSet142600msgid "SUN4-8000-K3.action"
331*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
332*261a51afSet142600#
333*261a51afSet142600# code: SUN4-8000-LY
334*261a51afSet142600# keys: fault.io.fire.pec.sw-algorithm
335*261a51afSet142600#
336*261a51afSet142600msgid "SUN4-8000-LY.type"
337*261a51afSet142600msgstr "Fault"
338*261a51afSet142600msgid "SUN4-8000-LY.severity"
339*261a51afSet142600msgstr "Critical"
340*261a51afSet142600msgid "SUN4-8000-LY.description"
341*261a51afSet142600msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
342*261a51afSet142600msgid "SUN4-8000-LY.response"
343*261a51afSet142600msgstr "One or more device instances may be disabled\n"
344*261a51afSet142600msgid "SUN4-8000-LY.impact"
345*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
346*261a51afSet142600msgid "SUN4-8000-LY.action"
347*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
348