10890ae4eSvn83148# 2*261a51afSet142600# Copyright 2007 Sun Microsystems, Inc. All rights reserved. 30890ae4eSvn83148# Use is subject to license terms. 40890ae4eSvn83148# 50890ae4eSvn83148# CDDL HEADER START 60890ae4eSvn83148# 70890ae4eSvn83148# The contents of this file are subject to the terms of the 89dd0f810Scindi# Common Development and Distribution License (the "License"). 99dd0f810Scindi# You may not use this file except in compliance with the License. 100890ae4eSvn83148# 110890ae4eSvn83148# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 120890ae4eSvn83148# or http://www.opensolaris.org/os/licensing. 130890ae4eSvn83148# See the License for the specific language governing permissions 140890ae4eSvn83148# and limitations under the License. 150890ae4eSvn83148# 160890ae4eSvn83148# When distributing Covered Code, include this CDDL HEADER in each 170890ae4eSvn83148# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 180890ae4eSvn83148# If applicable, add the following below this CDDL HEADER, with the 190890ae4eSvn83148# fields enclosed by brackets "[]" replaced with your own identifying 200890ae4eSvn83148# information: Portions Copyright [yyyy] [name of copyright owner] 210890ae4eSvn83148# 220890ae4eSvn83148# CDDL HEADER END 230890ae4eSvn83148# 240890ae4eSvn83148#ident "%Z%%M% %I% %E% SMI" 250890ae4eSvn83148# 261645b324Svn83148# DO NOT EDIT -- this file is generated by the Event Registry. 271645b324Svn83148# 280890ae4eSvn83148# 290890ae4eSvn83148# code: SUN4-8000-0Y 300890ae4eSvn83148# keys: fault.io.fire.asic 310890ae4eSvn83148# 320890ae4eSvn83148msgid "SUN4-8000-0Y.type" 330890ae4eSvn83148msgstr "Fault" 340890ae4eSvn83148msgid "SUN4-8000-0Y.severity" 350890ae4eSvn83148msgstr "Critical" 360890ae4eSvn83148msgid "SUN4-8000-0Y.description" 37*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 380890ae4eSvn83148msgid "SUN4-8000-0Y.response" 391645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 400890ae4eSvn83148msgid "SUN4-8000-0Y.impact" 410890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 420890ae4eSvn83148msgid "SUN4-8000-0Y.action" 43*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 440890ae4eSvn83148# 450890ae4eSvn83148# code: SUN4-8000-13 460890ae4eSvn83148# keys: fault.io.ebus 470890ae4eSvn83148# 480890ae4eSvn83148msgid "SUN4-8000-13.type" 490890ae4eSvn83148msgstr "Fault" 500890ae4eSvn83148msgid "SUN4-8000-13.severity" 510890ae4eSvn83148msgstr "Critical" 520890ae4eSvn83148msgid "SUN4-8000-13.description" 531645b324Svn83148msgstr "A problem was detected in the Ebus. Refer to %s for more information." 540890ae4eSvn83148msgid "SUN4-8000-13.response" 551645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 560890ae4eSvn83148msgid "SUN4-8000-13.impact" 570890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 580890ae4eSvn83148msgid "SUN4-8000-13.action" 59*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" 600890ae4eSvn83148# 610890ae4eSvn83148# code: SUN4-8000-2H 620890ae4eSvn83148# keys: fault.io.datapath 630890ae4eSvn83148# 640890ae4eSvn83148msgid "SUN4-8000-2H.type" 650890ae4eSvn83148msgstr "Fault" 660890ae4eSvn83148msgid "SUN4-8000-2H.severity" 670890ae4eSvn83148msgstr "Critical" 680890ae4eSvn83148msgid "SUN4-8000-2H.description" 6919017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 700890ae4eSvn83148msgid "SUN4-8000-2H.response" 7119017637Svn83148msgstr "None" 720890ae4eSvn83148msgid "SUN4-8000-2H.impact" 7319017637Svn83148msgstr "None" 740890ae4eSvn83148msgid "SUN4-8000-2H.action" 7519017637Svn83148msgstr "None" 760890ae4eSvn83148# 770890ae4eSvn83148# code: SUN4-8000-3D 780890ae4eSvn83148# keys: fault.io.hbus 790890ae4eSvn83148# 800890ae4eSvn83148msgid "SUN4-8000-3D.type" 810890ae4eSvn83148msgstr "Fault" 820890ae4eSvn83148msgid "SUN4-8000-3D.severity" 830890ae4eSvn83148msgstr "Critical" 840890ae4eSvn83148msgid "SUN4-8000-3D.description" 85*261a51afSet142600msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 860890ae4eSvn83148msgid "SUN4-8000-3D.response" 871645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 880890ae4eSvn83148msgid "SUN4-8000-3D.impact" 890890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 900890ae4eSvn83148msgid "SUN4-8000-3D.action" 91*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 920890ae4eSvn83148# 930890ae4eSvn83148# code: SUN4-8000-4P 940890ae4eSvn83148# keys: fault.io.fire.pciex.device 950890ae4eSvn83148# 960890ae4eSvn83148msgid "SUN4-8000-4P.type" 970890ae4eSvn83148msgstr "Fault" 980890ae4eSvn83148msgid "SUN4-8000-4P.severity" 990890ae4eSvn83148msgstr "Critical" 1000890ae4eSvn83148msgid "SUN4-8000-4P.description" 101*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 1020890ae4eSvn83148msgid "SUN4-8000-4P.response" 1031645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 1040890ae4eSvn83148msgid "SUN4-8000-4P.impact" 1050890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 1060890ae4eSvn83148msgid "SUN4-8000-4P.action" 107*261a51afSet142600msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." 1080890ae4eSvn83148# 1090890ae4eSvn83148# code: SUN4-8000-5A 1100890ae4eSvn83148# keys: defect.io.fire.pciex.driver 1110890ae4eSvn83148# 1120890ae4eSvn83148msgid "SUN4-8000-5A.type" 1130890ae4eSvn83148msgstr "Defect" 1140890ae4eSvn83148msgid "SUN4-8000-5A.severity" 1150890ae4eSvn83148msgstr "Critical" 1160890ae4eSvn83148msgid "SUN4-8000-5A.description" 117*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." 1180890ae4eSvn83148msgid "SUN4-8000-5A.response" 1191645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 1200890ae4eSvn83148msgid "SUN4-8000-5A.impact" 1210890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with\nthis problem" 1220890ae4eSvn83148msgid "SUN4-8000-5A.action" 1239dd0f810Scindimsgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 1240890ae4eSvn83148# 1250890ae4eSvn83148# code: SUN4-8000-6S 1260890ae4eSvn83148# keys: fault.io.datapath fault.io.fire.asic 1270890ae4eSvn83148# 1280890ae4eSvn83148msgid "SUN4-8000-6S.type" 1290890ae4eSvn83148msgstr "Fault" 1300890ae4eSvn83148msgid "SUN4-8000-6S.severity" 1310890ae4eSvn83148msgstr "Critical" 1320890ae4eSvn83148msgid "SUN4-8000-6S.description" 13319017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 1340890ae4eSvn83148msgid "SUN4-8000-6S.response" 13519017637Svn83148msgstr "None" 1360890ae4eSvn83148msgid "SUN4-8000-6S.impact" 13719017637Svn83148msgstr "None" 1380890ae4eSvn83148msgid "SUN4-8000-6S.action" 13919017637Svn83148msgstr "None" 1400890ae4eSvn83148# 1410890ae4eSvn83148# code: SUN4-8000-75 1420890ae4eSvn83148# keys: fault.io.fire.asic fault.io.fire.pciex.device 1430890ae4eSvn83148# 1440890ae4eSvn83148msgid "SUN4-8000-75.type" 1450890ae4eSvn83148msgstr "Fault" 1460890ae4eSvn83148msgid "SUN4-8000-75.severity" 1470890ae4eSvn83148msgstr "Critical" 1480890ae4eSvn83148msgid "SUN4-8000-75.description" 149*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." 1500890ae4eSvn83148msgid "SUN4-8000-75.response" 1511645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 1520890ae4eSvn83148msgid "SUN4-8000-75.impact" 1530890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 1540890ae4eSvn83148msgid "SUN4-8000-75.action" 155*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 1560890ae4eSvn83148# 1570890ae4eSvn83148# code: SUN4-8000-8E 1580890ae4eSvn83148# keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver 1590890ae4eSvn83148# 1600890ae4eSvn83148msgid "SUN4-8000-8E.type" 1610890ae4eSvn83148msgstr "Defect" 1620890ae4eSvn83148msgid "SUN4-8000-8E.severity" 1630890ae4eSvn83148msgstr "Critical" 1640890ae4eSvn83148msgid "SUN4-8000-8E.description" 165*261a51afSet142600msgstr "A problem was detected in the PCI-Express subsystem software. Refer to %s for more information." 1660890ae4eSvn83148msgid "SUN4-8000-8E.response" 1671645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 1680890ae4eSvn83148msgid "SUN4-8000-8E.impact" 1690890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this problem" 1700890ae4eSvn83148msgid "SUN4-8000-8E.action" 1719dd0f810Scindimsgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." 1720890ae4eSvn83148# 1730890ae4eSvn83148# code: SUN4-8000-9J 1740890ae4eSvn83148# keys: fault.io.fire.pci.device fault.io.fire.pciex.device 1750890ae4eSvn83148# 1760890ae4eSvn83148msgid "SUN4-8000-9J.type" 1770890ae4eSvn83148msgstr "Fault" 1780890ae4eSvn83148msgid "SUN4-8000-9J.severity" 1790890ae4eSvn83148msgstr "Critical" 1800890ae4eSvn83148msgid "SUN4-8000-9J.description" 18119017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 1820890ae4eSvn83148msgid "SUN4-8000-9J.response" 18319017637Svn83148msgstr "None" 1840890ae4eSvn83148msgid "SUN4-8000-9J.impact" 18519017637Svn83148msgstr "None" 1860890ae4eSvn83148msgid "SUN4-8000-9J.action" 18719017637Svn83148msgstr "None" 1880890ae4eSvn83148# 1890890ae4eSvn83148# code: SUN4-8000-A2 1900890ae4eSvn83148# keys: fault.io.fire.pci.device 1910890ae4eSvn83148# 1920890ae4eSvn83148msgid "SUN4-8000-A2.type" 1930890ae4eSvn83148msgstr "Fault" 1940890ae4eSvn83148msgid "SUN4-8000-A2.severity" 1950890ae4eSvn83148msgstr "Critical" 1960890ae4eSvn83148msgid "SUN4-8000-A2.description" 197*261a51afSet142600msgstr "A problem was detected in the PCI subsystem.\n Refer to %s for more information." 1980890ae4eSvn83148msgid "SUN4-8000-A2.response" 1991645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 2000890ae4eSvn83148msgid "SUN4-8000-A2.impact" 2010890ae4eSvn83148msgstr "Loss of services provided by the device instances associated with this fault" 2020890ae4eSvn83148msgid "SUN4-8000-A2.action" 203*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 2040890ae4eSvn83148# 2050890ae4eSvn83148# code: SUN4-8000-CX 2060890ae4eSvn83148# keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic 2070890ae4eSvn83148# 2080890ae4eSvn83148msgid "SUN4-8000-CX.type" 2090890ae4eSvn83148msgstr "Fault" 2100890ae4eSvn83148msgid "SUN4-8000-CX.severity" 2110890ae4eSvn83148msgstr "Critical" 2120890ae4eSvn83148msgid "SUN4-8000-CX.description" 21319017637Svn83148msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." 2140890ae4eSvn83148msgid "SUN4-8000-CX.response" 21519017637Svn83148msgstr "None" 2160890ae4eSvn83148msgid "SUN4-8000-CX.impact" 21719017637Svn83148msgstr "None" 2180890ae4eSvn83148msgid "SUN4-8000-CX.action" 21919017637Svn83148msgstr "None" 22019017637Svn83148# 22119017637Svn83148# code: SUN4-8000-D4 22219017637Svn83148# keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device 22319017637Svn83148# 22419017637Svn83148msgid "SUN4-8000-D4.type" 22519017637Svn83148msgstr "Fault" 22619017637Svn83148msgid "SUN4-8000-D4.severity" 22719017637Svn83148msgstr "Critical" 22819017637Svn83148msgid "SUN4-8000-D4.description" 22919017637Svn83148msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 23019017637Svn83148msgid "SUN4-8000-D4.response" 2311645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 23219017637Svn83148msgid "SUN4-8000-D4.impact" 23319017637Svn83148msgstr "Loss of services provided by the device instances associated with this fault" 23419017637Svn83148msgid "SUN4-8000-D4.action" 235*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 23619017637Svn83148# 23719017637Svn83148# code: SUN4-8000-ER 23819017637Svn83148# keys: fault.io.fire.asic fault.io.fire.pci.device 23919017637Svn83148# 24019017637Svn83148msgid "SUN4-8000-ER.type" 24119017637Svn83148msgstr "Fault" 24219017637Svn83148msgid "SUN4-8000-ER.severity" 24319017637Svn83148msgstr "Critical" 24419017637Svn83148msgid "SUN4-8000-ER.description" 24519017637Svn83148msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." 24619017637Svn83148msgid "SUN4-8000-ER.response" 2471645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 24819017637Svn83148msgid "SUN4-8000-ER.impact" 24919017637Svn83148msgstr "Loss of services provided by the device instances associated with this fault" 25019017637Svn83148msgid "SUN4-8000-ER.action" 251*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" 2521645b324Svn83148# 2531645b324Svn83148# code: SUN4-8000-FC 2541645b324Svn83148# keys: fault.io.fire.hbus 2551645b324Svn83148# 2561645b324Svn83148msgid "SUN4-8000-FC.type" 2571645b324Svn83148msgstr "Fault" 2581645b324Svn83148msgid "SUN4-8000-FC.severity" 2591645b324Svn83148msgstr "Major" 2601645b324Svn83148msgid "SUN4-8000-FC.description" 261*261a51afSet142600msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." 2621645b324Svn83148msgid "SUN4-8000-FC.response" 2631645b324Svn83148msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." 2641645b324Svn83148msgid "SUN4-8000-FC.impact" 2651645b324Svn83148msgstr "Loss of services provided by the device instances associated with this fault" 2661645b324Svn83148msgid "SUN4-8000-FC.action" 267*261a51afSet142600msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" 26814ea4bb7Ssd77468# 26914ea4bb7Ssd77468# code: SUN4-8000-GQ 27014ea4bb7Ssd77468# keys: fault.io.fire.datapath fault.io.fire.hbus 27114ea4bb7Ssd77468# 27214ea4bb7Ssd77468msgid "SUN4-8000-GQ.type" 27314ea4bb7Ssd77468msgstr "Fault" 27414ea4bb7Ssd77468msgid "SUN4-8000-GQ.severity" 27514ea4bb7Ssd77468msgstr "Critical" 27614ea4bb7Ssd77468msgid "SUN4-8000-GQ.description" 27714ea4bb7Ssd77468msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n Refer to %s for more information." 27814ea4bb7Ssd77468msgid "SUN4-8000-GQ.response" 27914ea4bb7Ssd77468msgstr "One or more device instances may be disabled\n" 28014ea4bb7Ssd77468msgid "SUN4-8000-GQ.impact" 28114ea4bb7Ssd77468msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 28214ea4bb7Ssd77468msgid "SUN4-8000-GQ.action" 28314ea4bb7Ssd77468msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 284*261a51afSet142600# 285*261a51afSet142600# code: SUN4-8000-HD 286*261a51afSet142600# keys: fault.io.fire.hb.sw-config 287*261a51afSet142600# 288*261a51afSet142600msgid "SUN4-8000-HD.type" 289*261a51afSet142600msgstr "Fault" 290*261a51afSet142600msgid "SUN4-8000-HD.severity" 291*261a51afSet142600msgstr "Critical" 292*261a51afSet142600msgid "SUN4-8000-HD.description" 293*261a51afSet142600msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 294*261a51afSet142600msgid "SUN4-8000-HD.response" 295*261a51afSet142600msgstr "One or more device instances may be disabled\n" 296*261a51afSet142600msgid "SUN4-8000-HD.impact" 297*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 298*261a51afSet142600msgid "SUN4-8000-HD.action" 299*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 300*261a51afSet142600# 301*261a51afSet142600# code: SUN4-8000-JH 302*261a51afSet142600# keys: fault.io.fire.dmc.sw-algorithm 303*261a51afSet142600# 304*261a51afSet142600msgid "SUN4-8000-JH.type" 305*261a51afSet142600msgstr "Fault" 306*261a51afSet142600msgid "SUN4-8000-JH.severity" 307*261a51afSet142600msgstr "Critical" 308*261a51afSet142600msgid "SUN4-8000-JH.description" 309*261a51afSet142600msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 310*261a51afSet142600msgid "SUN4-8000-JH.response" 311*261a51afSet142600msgstr "One or more device instances may be disabled\n" 312*261a51afSet142600msgid "SUN4-8000-JH.impact" 313*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 314*261a51afSet142600msgid "SUN4-8000-JH.action" 315*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 316*261a51afSet142600# 317*261a51afSet142600# code: SUN4-8000-K3 318*261a51afSet142600# keys: fault.io.fire.dmc.sw-state 319*261a51afSet142600# 320*261a51afSet142600msgid "SUN4-8000-K3.type" 321*261a51afSet142600msgstr "Fault" 322*261a51afSet142600msgid "SUN4-8000-K3.severity" 323*261a51afSet142600msgstr "Critical" 324*261a51afSet142600msgid "SUN4-8000-K3.description" 325*261a51afSet142600msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n Refer to %s for more information." 326*261a51afSet142600msgid "SUN4-8000-K3.response" 327*261a51afSet142600msgstr "One or more device instances may be disabled\n" 328*261a51afSet142600msgid "SUN4-8000-K3.impact" 329*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 330*261a51afSet142600msgid "SUN4-8000-K3.action" 331*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 332*261a51afSet142600# 333*261a51afSet142600# code: SUN4-8000-LY 334*261a51afSet142600# keys: fault.io.fire.pec.sw-algorithm 335*261a51afSet142600# 336*261a51afSet142600msgid "SUN4-8000-LY.type" 337*261a51afSet142600msgstr "Fault" 338*261a51afSet142600msgid "SUN4-8000-LY.severity" 339*261a51afSet142600msgstr "Critical" 340*261a51afSet142600msgid "SUN4-8000-LY.description" 341*261a51afSet142600msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information." 342*261a51afSet142600msgid "SUN4-8000-LY.response" 343*261a51afSet142600msgstr "One or more device instances may be disabled\n" 344*261a51afSet142600msgid "SUN4-8000-LY.impact" 345*261a51afSet142600msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 346*261a51afSet142600msgid "SUN4-8000-LY.action" 347*261a51afSet142600msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 348