1e5dcf7beSRobert Johnston# 2e5dcf7beSRobert Johnston# Copyright 2009 Sun Microsystems, Inc. All rights reserved. 3e5dcf7beSRobert Johnston# Use is subject to license terms. 4e5dcf7beSRobert Johnston# 5e5dcf7beSRobert Johnston# CDDL HEADER START 6e5dcf7beSRobert Johnston# 7e5dcf7beSRobert Johnston# The contents of this file are subject to the terms of the 8e5dcf7beSRobert Johnston# Common Development and Distribution License (the "License"). 9e5dcf7beSRobert Johnston# You may not use this file except in compliance with the License. 10e5dcf7beSRobert Johnston# 11e5dcf7beSRobert Johnston# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12e5dcf7beSRobert Johnston# or http://www.opensolaris.org/os/licensing. 13e5dcf7beSRobert Johnston# See the License for the specific language governing permissions 14e5dcf7beSRobert Johnston# and limitations under the License. 15e5dcf7beSRobert Johnston# 16e5dcf7beSRobert Johnston# When distributing Covered Code, include this CDDL HEADER in each 17e5dcf7beSRobert Johnston# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18e5dcf7beSRobert Johnston# If applicable, add the following below this CDDL HEADER, with the 19e5dcf7beSRobert Johnston# fields enclosed by brackets "[]" replaced with your own identifying 20e5dcf7beSRobert Johnston# information: Portions Copyright [yyyy] [name of copyright owner] 21e5dcf7beSRobert Johnston# 22e5dcf7beSRobert Johnston# CDDL HEADER END 23e5dcf7beSRobert Johnston# 24e5dcf7beSRobert Johnston# DO NOT EDIT -- this file is generated by the Event Registry. 25e5dcf7beSRobert Johnston# 26e5dcf7beSRobert Johnston# 27e5dcf7beSRobert Johnston# code: SENSOR-8000-09 28e5dcf7beSRobert Johnston# keys: fault.sensor.fan.failed 29e5dcf7beSRobert Johnston# 30e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.type" 31e5dcf7beSRobert Johnstonmsgstr "Fault" 32e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.severity" 33e5dcf7beSRobert Johnstonmsgstr "Minor" 34e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.description" 35e5dcf7beSRobert Johnstonmsgstr "External sensors indicate that a fan is no longer operating\ncorrectly. Refer to %s for more information." 36e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.response" 37e5dcf7beSRobert Johnstonmsgstr "None." 38e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.impact" 39e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate cooling. If the problem\npersists, the components may overheat and the enclosure may shutdown." 40e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-09.action" 41e5dcf7beSRobert Johnstonmsgstr "Check the fan to see if the fan has lost power or there is a\nphysical obstruction. Replace the fan if the internal mechanism has failed.\n" 42e5dcf7beSRobert Johnston# 43e5dcf7beSRobert Johnston# code: SENSOR-8000-1N 44e5dcf7beSRobert Johnston# keys: fault.sensor.psu.failed 45e5dcf7beSRobert Johnston# 46e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.type" 47e5dcf7beSRobert Johnstonmsgstr "Fault" 48e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.severity" 49e5dcf7beSRobert Johnstonmsgstr "Minor" 50e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.description" 51e5dcf7beSRobert Johnstonmsgstr "External sensors indicate that a power supply is no longer operating correctly. Refer to %s for more information." 52e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.response" 53e5dcf7beSRobert Johnstonmsgstr "None." 54e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.impact" 55e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate power. Subsequent loss of power supplies may force the enclosure to shutdown." 56e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-1N.action" 57e5dcf7beSRobert Johnstonmsgstr "Check to see if the power cord is connected properly. Replace the power supply if the internal mechanism has failed.\n" 58e5dcf7beSRobert Johnston# 59e5dcf7beSRobert Johnston# code: SENSOR-8000-26 60e5dcf7beSRobert Johnston# keys: fault.fan.failed 61e5dcf7beSRobert Johnston# 62e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.type" 63e5dcf7beSRobert Johnstonmsgstr "Fault" 64e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.severity" 65e5dcf7beSRobert Johnstonmsgstr "Minor" 66e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.description" 67e5dcf7beSRobert Johnstonmsgstr "External sensors indicate that a fan is no longer operating correctly. Refer to %s for more information." 68e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.response" 69e5dcf7beSRobert Johnstonmsgstr "None." 70e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.impact" 71e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate cooling. If the problem persists, the components may overheat and the enclosure may shutdown." 72e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-26.action" 73e5dcf7beSRobert Johnstonmsgstr "Check the fan to see if the fan has lost power or there is a physical obstruction. Replace the fan if the internal mechanism has failed.\n" 74e5dcf7beSRobert Johnston# 75e5dcf7beSRobert Johnston# code: SENSOR-8000-3T 76e5dcf7beSRobert Johnston# keys: fault.psu.failed 77e5dcf7beSRobert Johnston# 78e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.type" 79e5dcf7beSRobert Johnstonmsgstr "Fault" 80e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.severity" 81*9983899bSRobert Johnstonmsgstr "Major" 82e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.description" 83e5dcf7beSRobert Johnstonmsgstr "External sensors indicate that a power supply is no longer operating correctly. Refer to %s for more information." 84e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.response" 85e5dcf7beSRobert Johnstonmsgstr "None." 86e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.impact" 87e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate power. Subsequent loss of power supplies may force the enclosure to shutdown." 88e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-3T.action" 89e5dcf7beSRobert Johnstonmsgstr "Check to see if the power cord is connected properly. Replace the power supply if the internal mechanism has failed.\n" 90e5dcf7beSRobert Johnston# 91e5dcf7beSRobert Johnston# code: SENSOR-8000-40 92e5dcf7beSRobert Johnston# keys: fault.fan.failed-pred 93e5dcf7beSRobert Johnston# 94e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.type" 95e5dcf7beSRobert Johnstonmsgstr "Fault" 96e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.severity" 97e5dcf7beSRobert Johnstonmsgstr "Minor" 98e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.description" 99e5dcf7beSRobert Johnstonmsgstr "A preditive failure sensor indicates that this fan has either failed or that a failure is imminent.\n Refer to %s for more information." 100e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.response" 101e5dcf7beSRobert Johnstonmsgstr "None." 102e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.impact" 103e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate cooling. If the problem persists, the components may overheat and the enclosure may shutdown." 104e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-40.action" 105e5dcf7beSRobert Johnstonmsgstr "Check the fan to see if the fan has lost power or there is a physical obstruction. Replace the fan if the internal mechanism has failed.\n" 106e5dcf7beSRobert Johnston# 107e5dcf7beSRobert Johnston# code: SENSOR-8000-5V 108e5dcf7beSRobert Johnston# keys: fault.psu.failed-pred 109e5dcf7beSRobert Johnston# 110e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.type" 111e5dcf7beSRobert Johnstonmsgstr "Fault" 112e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.severity" 113e5dcf7beSRobert Johnstonmsgstr "Minor" 114e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.description" 115e5dcf7beSRobert Johnstonmsgstr "A preditive failure sensor indicates that this power supply has either failed or that a failure is imminent. Refer to %s for more information." 116e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.response" 117e5dcf7beSRobert Johnstonmsgstr "None." 118e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.impact" 119e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate power. Subsequent loss of power supplies may force the enclosure to shutdown." 120e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-5V.action" 121e5dcf7beSRobert Johnstonmsgstr "Check to see if the power cord is connected properly. Replace the power supply if the internal mechanism has failed.\n" 122e5dcf7beSRobert Johnston# 123e5dcf7beSRobert Johnston# code: SENSOR-8000-6G 124e5dcf7beSRobert Johnston# keys: fault.psu.failed-int 125e5dcf7beSRobert Johnston# 126e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.type" 127e5dcf7beSRobert Johnstonmsgstr "Fault" 128e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.severity" 129*9983899bSRobert Johnstonmsgstr "Major" 130e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.description" 131e5dcf7beSRobert Johnstonmsgstr "A sensor indicates that this power supply has failed. Refer to %s for more information." 132e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.response" 133e5dcf7beSRobert Johnstonmsgstr "None." 134e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.impact" 135e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate power. Subsequent loss of power supplies may force the enclosure to shutdown." 136e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-6G.action" 137e5dcf7beSRobert Johnstonmsgstr "Replace the indicated power supply" 138e5dcf7beSRobert Johnston# 139e5dcf7beSRobert Johnston# code: SENSOR-8000-7L 140e5dcf7beSRobert Johnston# keys: fault.psu.failed-ext 141e5dcf7beSRobert Johnston# 142e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.type" 143e5dcf7beSRobert Johnstonmsgstr "Fault" 144e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.severity" 145*9983899bSRobert Johnstonmsgstr "Major" 146e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.description" 147e5dcf7beSRobert Johnstonmsgstr "A sensor indicates that this power supply is not operating properly due to some external condition Refer to %s for more information." 148e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.response" 149e5dcf7beSRobert Johnstonmsgstr "None." 150e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.impact" 151e5dcf7beSRobert Johnstonmsgstr "The enclosure may be getting inadequate power. Subsequent loss of power supplies may force the enclosure to shutdown." 152e5dcf7beSRobert Johnstonmsgid "SENSOR-8000-7L.action" 153e5dcf7beSRobert Johnstonmsgstr "Check to see if the power cord is connected properly or if there are other conditions that may be causing inadequate power to be provided to the indicated power supply.\n" 154